You are on page 1of 2

Description

Which of following the bridge is used for the measurement of meadium resistance
which of following the bridge is used for the measurement of very low resistance
Loss of charge method used for the measurement of __________ range of resistances.
For the measurement of insulation reistance of machines and cables, the following method is used
wheastone bridge can not be used for precision measurements because errors are intoduced into on account of
The inductnce of high quality factor inductor can be measured by a
The AC bridge used for measurement of dielectric loss of capacitor is
In Maxwell's inducatnce-capacitance bridge a resistance is in _________ with standard capacitor and in Hay's bridge a resistan
________ with a standard capacitor.
Head phones are widely used as detectors in AC bridges for the _____ range of frequencies is more sensitive.
For measurment unknown quantities at low frequencies _______ may act as the source of supply used in AC bridges.

Which of the following AC bridge is more useful for the measurement of inductance at power and audio frequencies.
Frequency can be measured by using
Maxwell's inductance-capacitance bridge is used for measurement of inductance of
The bridge network employed for the measurement of mutual inductance is _____________
The four arms of bridge network has Zab =Zbc = 100 L-30 Ω ; Zcd = 50 L-60 Ω and an unknown impedance is connect between
rms .Then unknown impedance is Zda is _________
The Wien’s bridges is suitable for the measurement of frequency of the range of
The commonly used detectors in ac bridges is/are
The Q meter works on the principle of
In a Wheatstone bridge, if P = 10 ± 1%, Q = 100 ± 1%, S= 20 ± 1% and ' R 'is unknown then the unknown resistance will be
A wheatstone bridge has ratio arms of 1000 Ω and 100 Ω resistance , the standard resistance arm consists of 4 decade resistan
1000,100,10,1 Ω steps. The maximum and minimum value of unknown resistance that can be determined with this setup are:

Instrument transformers find wide applications in ______________ circuits of power system


Ratio of the magnitude of the primary winding current to secondary winding current is
The ratio error and phase angle error in a potential transformer can be reduced by
The burden of current transformers is expressed in terms of
Ratio error of a CT is expressed as
In potential transformer, with increase in frequency the phase angle
Causes of error in CT may due to
Choose the wrong one from the following statements
If the power is measured by two wattmeter method of a circuit whose power factor is 0.5 then one of the wattmeter will read

Electro-dynamometer wattmeter is not suitable for low power factor power measurement because of
For the measurement of energy and power it is essential to know 
Measurement of power in circuits having low power factor is not done by using ordinary electrodynamometer wattmeter, bec

Power factor can be measured by


Power factor meter is perfectly balanced at equilibrium by two opposing forces, so it doesn’t need
In the two wattmeter method of three-phase power measurement, if the reading of one of the wattmeter is negative then po
the circuit is
While measuring the power by two wattmeter method the reading of one of the wattmeter is observed to be zero This indicat
power factor of load is
Electro-dynamometer type wattmeter have
In power measurement of balance three-phase system the readings of the two wattmeter’s are W 1=200 W, W2=40 W, if the la
is obtained after reversing the connections to the current coil of W2, then the power factor of the load is
The secoundry of a CT is never left open circuited because otherwise
A current transformer has a phase error of 3 degrees. The phase angle between the primary and secoundry current is
The stator of phase shifting transformer for use in conjunction with an A.C. potentiometer usually has a ………….
In order to achieve high accuracy, the slide wire of a potentiometer should be …………
In an A.C. co-ordinate potentiometer, the currents in the phase and quadrature potentiometer are adjusted to be …………..
The best device to measure the true open circuit e.m.f. of a battery is ………….
A phase shifting transformer is used in conjunction with ………..
Basically a potentiometer is a device for ………………
The input impedance of C.R.O. is ………………
Phosphor coating for cathode ray tubes is provided on ……….
Oscilloscope is __________
Typically oscilloscope represents __________
By making use of a CRO _________
In radio applications, CRO is used for measuring __________
In medical applications CRO can be used for __________
In time base generator Sweep rate is controlled by a ________
What determines light intensity in a CRT?
What is the role of intensity section in a CRO?
What is the role of the focus section in a CRO?
Digital voltmeters converts ________
In a DVM, a transducer converts ________
A successive approximation type DVM makes use _______

You might also like