INPUT SPECIFICATIONS
I.D (Di) : 2000mm
Height (h) : 3000mm
Design Pressure : Static Head of Liquid
Design temperature : 80C
Service Medium : 10% AQUEOUS SODIUM SULFITE
Density of medium : 1100 Kg/m3
Bottom : Flat
Top : Flat
DESIGN CALCULATION
1
3. CALCULATION OF DESIGN UNIT LOAD OF LAMINATE
UL(WR) = UTUS(WR) / K
= 250/ 10
= 25 N/mm per kg/m2 of glass
UTUS = Ultimate tensile unit strength in N/mm width per kg/m2 glass
(UTUS for CSM & WR is taken from Table 5 page 10)
US(WR) = X(WR) x ed
=16000 x 0.002
=32 N/mm per kg/m2 of glass
2
3.4 Calculation of Strain for minimum unit load (e)
e(CSM) = 20 / 14000
= 0.00143
e(WR) = 25 / 16000
= 0.00156
Uz(WR) = X(WR) x el
=16000 x 0.00143
= 22.9 N/mm per Kg/m2 of glass
For design validation, Sum (uzmznz) > Q [Refer Eq (6) Page No :16]
Abbreviation used