Professional Documents
Culture Documents
C3 (m) Nominal value =0.003 m Range = 0.005 for resilient soild to 0 for hardpan
Hiley's Formula (fill in the cells in light green)
Type of pile = 400 mm Square Pile
Weight of pile per meter = 384 kg/m
Driven Pile length, L = 30 meter
Driving Hammer = Hydraulic Hammer 150mm Sq Pile =
Weight of ram, W = 7 tonnes 175mm Sq Pile =
Weight of pile, P = 11.52 tonnes 200mm Sq Pile =
Ram drop height, H = 800 mm = 31.50 inches 225mm Sq Pile =
Hammer efficiency, ef = 0.75 250mm Sq Pile =
Coeff. Restitution, N = 0.25 275mm Sq Pile =
Temp. compression, C = 18 mm = 0.709 inches 300mm Sq Pile =
Set / 10 blow , S = 20 mm = 0.79 inches 325mm Sq Pile =
Efficiency Factor, f = W + (P x N x N) 350mm Sq Pile =
W+P 375mm Sq Pile =
= 0.4168 400mm Sq Pile =
Ultimate Resistance, R = ef x W x H x f 450mm Sq Pile =
S + C/2
= 159.16 tonnes