You are on page 1of 3

DESIGN CALCULATION FOR PILECAP 3RC250 1 of 3

Project : T0516-ECO SANCTUARY Designed by : CPL Date : 23-Feb-16


Title : Pilecap Design for 3RC250 Checked by : LYJ Page :

Pile Type = RC (SP for Spun Pile and RC for RC Square Pile)
Number of Piles = 3
Pile Size = 250 mm
Pile Working Load = 850 kN
Column Load = 2300 kN
Column Load + Pilecap Weight = 2323 kN
Reaction per Pile = 774 kN, < Pile Working Load, OK.
Column Type = SC (SC for Square Column and CC for Circular Column)
Column Length, B = 450 mm
y
Column Width, D = 450 mm
Column Perimeter = 1800 mm My-y
Concrete Grade, fcu = 35 N/mm2
Steel Strength, fy = 460 N/mm2 x
Concrete Cover, c = 75 mm Mx-x
Distance from Pile Center to Pilecap Edge = 327 mm
Pile Spacing = 2.5 x Pile Size = 625 mm
Factor of Safety, FoS = 1.50

Pilecap Effective Width, beff = 1196 mm


Pilecap Width, b1 = 542 mm
Pilecap Effective Length, leff = 1279 mm
Pilecap Length, l1 = 312.5 mm
Pilecap Thickness, h = 700 mm
Lever arm, Lx = 163 mm (Including 75mm deviation)
Lever arm, Ly = 211 mm (Including 75mm deviation)

Steel Reinforcement Bars Design


(A) My-y (Bars Lay Parallel with X-axis)
Effective Depth, d = 619 mm
Design Moment = 207 kNm
K = 0.013 =====> z = 588 mm
As required, As req = 806 mm 2

As minimum = 1088 mm2 > As required


As maximum = 33488 mm2 > As required
Design As = 1088 mm2
To Provide Bottom Reinforcement 10 T 12 mm diameter, Bar c/c spacing = 116 mm

(B) Mx-x (Bars Lay Parallel with Y-axis)


Effective Depth, d = 607 mm
Design Moment = 269 kNm
K = 0.016 =====> z = 577 mm
As required, As req = 1067 mm 2

As minimum = 1164 mm2 > As required


As maximum = 35812 mm2 > As required
Design As = 1164 mm2
To Provide Bottom Reinforcement 11 T 12 mm diameter, Bar c/c spacing = 113 mm

541629835.xls
DESIGN CALCULATION FOR PILECAP 3RC250 2 of 3

Project : T0516-ECO SANCTUARY Designed by : CPL Date : 23-Feb-16


Title : Pilecap Design for 3RC250 Checked by : LYJ Page :

541629835.xls
DESIGN CALCULATION FOR PILECAP 3RC250 3 of 3

Project : T0516-ECO SANCTUARY Designed by : CPL Date : 23-Feb-16


Title : Pilecap Design for 3RC250 Checked by : LYJ Page :

Shear Check

Shear at column face = 3.13 N/mm2 < 4.73 N/mm2

(A) X-axis
Shear force = 1275 kN
Shear stress = 1.72 N/mm2
100 x As, prov / bd = 0.15 < 3, = 0.15
400 / d = 0.65 < 1, = 1
fcu / 25 = 1.40
av = 88 mm
vc = 0.38 N/mm2
Shear resistance = 4.73 N/mm2 > 1.72 N/mm2 OK

(B) Y-axis
Shear force = 1275 kN
Shear stress = 1.64 N/mm2
100 x As, prov / bd = 0.16 < 3, = 0.16
400 / d = 0.66 < 1, = 1
fcu / 25 = 1.40
av = 136 mm
vc = 0.38 N/mm2
Shear resistance = 3.43 N/mm2 > 1.64 N/mm2 OK

Provide T16 - 200mm c/c as binder;


Provide Binder 2 T 16

center line

y
center line

Legend:

- Pile Point

541629835.xls

You might also like