Hydraulics

SV 1-10/210 aluminium servo valve


View
Function: 4/3 way proportional valve, single-stage
Drive: electromagnetic rotary drive with return springs
(patented)
Hydraulic connection: ISO 4401 NG10 / Cetop 5
Size/weight: H x W x L 127 x 74 x 263 mm / 3.5 kg

Intended purpose and design:


The servo valve SV 1-10/120 or SV 1-10/210 controls a hydraulic output value (volume
flow) proportional to an electrical input value, at a constant pressure drop over the
internal control edges.
In comparison to the steel servo valve, the aluminium version, in combination with its
optimised design, produces the same performance but exhibits a lower weight and
improved flow conditions.

Dimension sheet

Electrical characteristics SV 1-10/… 4 8 16

Connection 1 - 2:
Rated current mA ±300 ±300 ±300
Rated dither signal 50 Hz mA 10 10 20
150 HZ mA 20 20 40

Document No.: DB_SV1-10_210_00_en


Data sheet Document-ID: EMGDES-00008133 1
EMG Automation GmbH / Industriestraße 1 / 57482 Wenden (Ger) Tel. + 49 (0) 27 62 / 612 - 0
Fax. + 49 (0) 27 62 / 612 - 384
info@emg-automation.com
Hydraulics

Electrical characteristics SV 1-10/… 4 8 16


Resistance W 40 40 40
Inductance H 0.16 0.16 0.16

Connection 1 - 3:
Rated current mA ±300 ±300 ±300
Rated dither signal 50 Hz mA ±600 ±600 ±600
150 HZ mA
Resistance W 20 20 40
40 40 80
Inductance H 20 20 20
Plug device Three-pole appliance outlet A with earth contact, DIN 43650
Protection class IP 65 (with the plug device being screwed together)

Hydraulic characteristics SV 1-10/… 4 8 16


Operating pressure range pS 20 … 210 bar
5 … 120 bar
2 … 60 bar
max. permissible return pressure pT 30 bar
Caution: Do not use any additio-
nal shut-off valves in the return
line apart from the conventional
back-pressure valve.
Nominal flow rate QN at D pN = 20 bar l/min 4 8 16
at D pN = 70 bar l/min 7 13 24
External leakage volume flow 0
Operating temperature range: -10 … +70 °C
Storage temperature range: -20 … +80 °C
The following data applies with rated dither signal.
typ. internal leakage volume flow QO2 at pS = 100 bar;
I = 0 mA; t = 50 °C; QA = 0 l/min; QB = 0 l/min
SV 1-10 / .. / 210 / 6
SV 1-10 / .. / 210 / 1 l/min 0.2 0.3 0.5
SV 1-10 / .. / 120 / 6 l/min 0.3 0.5 0.8
SV 1-10 / .. / 120 / 1 l/min 0.3 0.5 0.8
SV 1-10 / .. / 60 / 6 l/min 0.5 0.8 1.2
SV 1-10 / .. / 60 / 1 l/min 0.5 0.8 1.3
l/min 0.8 1.3 1.2
Hysteresis 1) % <2 <2 <2.5
hysteresis error % <0.1 <0.1 <0.2
response sensitivity % <0.1 <0.1 <0.2
volume flow non-linearity % <2 <3 <4
volume flow asymmetry % <5 <5 <5
typ. relative pressure intensifier
SV 1-10 / .. / 210 / 6 14
SV 1-10 / .. / 210 / 1 25
SV 1-10 / .. / 120 / 6 12
SV 1-10 / .. / 120 / 1 20
SV 1-10 / .. / 60 / 6 12
SV 1-10 / .. / 60 / 1 20
Overlap SV 1-10 / .. / … /1 0.5 … 2.5 %
SV 1-10 / .. / … /6 4…8 %
Temperature drift of the zero point Not measurable, theoretically zero
Recommended pressurising medium 2) Hydraulic oil H-L 46
Recommended filtration Pressure filter without bypass, with contamination warning β 10 ≥ 75 under all
operating conditions
1
) largest part due to the magnet 2) other pressurising media after consultation: HFC

Document No.: DB_SV1-10_210_00_en


Data sheet Document-ID: EMGDES-00008133 2
EMG Automation GmbH / Industriestraße 1 / 57482 Wenden (Ger) Tel. + 49 (0) 27 62 / 612 - 0
Fax. + 49 (0) 27 62 / 612 - 384
info@emg-automation.com
Hydraulics

Type code SV 1 - 10 / 16 / 120 / 1 / C


SV = servo valve
1 = single-stage
10 = nominal size 10 (DIN 24340)
4 = nominal flow rate in l/min at DPN = 20 bar
8
16
2 - 60 = supply pressure in bar
5 - 120
20 - 210
1 % = overlap
6%
C = HFC
Hydraulic oil - no reference

Document No.: DB_SV1-10_210_00_en