You are on page 1of 3

MAKING MODERN LIVING POSSIBLE

The AKS 4100 - Liquid Level Sensor

A whole new level of


flexibility and accuracy
Experience the AKS 4100 Liquid Level Sensor with All sensors in the new AKS 4100 family are easy to
TDR Guided Radar technology (Time Domain install and fully flexible. No on-site calibration is
Reflectometry) fully adapted to the Industrial needed, and the probe length can easily be adjusted
Refrigeration segment – reliable and with high on site.
accuracy.

7:1
Inventory reduction
One AKS 4100 covers
seven different applica-
tion areas and several
lengths.

75%
Time savings
Due to the very easy on-site
adjustment procedure, with
AKS 4100 you will experience
significant time savings during
installation.

www.danfoss.com/AKS4100
Technical details of the AKS 4100
Measuring range of AKS 4100 - CABLE version
Bottom deadzone values based on the factory setting of
dielectric constant Reference point
Refrigerant Probe length range Bottom dead zone
[mm] [mm]
Top dead zones 20 mA
800 115 120 mm (4.7 in.) (100 %)*
801 - 999 120
Ammonia, 1000 - 1999 150
HFC, HCFC 2000 - 2999 180
3000 - 3999 210
4000 - 5000 240

Inner length of the standpipe


Improved Bottom dead zone values after the adjustment of
dielectric constant

diameter: 2-4 in.

4 mA (0 %)*
Measuring range

Probe length*
The benefits of

Distance
Refrigerant Probe length range Bottom dead zone

Standpipe
[mm] [mm]
Ammonia,

the AKS 4100


800 - 5000 90
HFC, HCFC

Code number with HMI Code no.


AKS 4100 with 5 m (197 in.) Ø2 mm (Ø0.08
084H4501
in.) stainless cable and counterweight Surface level
 Easy on-site probe length adjustment, * Values to be entered into HMI Quick Setup menu and recorded on
easy commissioning regardless of liquid the setting label. Stick the setting label onto the Signal Converter
either inside or outside.
level or refrigerant type - including
ammonia and CO2
Bottom dead zone (see tables)
Counterweight: 33 mm (1.3 in.)
 The cable version is very compact and Min: 20 mm (0.8 in.)

easy to handle, ship, install and use with Steel wire


different lengths and refrigerants Danfoss
insertion length:
M84H0017_1 12 mm (0.5 in.)

 The AKS 4100 sensors are available with


cable or Coaxial (sleeve) tube Measuring range of AKS 4100 - COAXIAL version
 The AKS 4100/4100U can be used with all Dielectric Constant εr always set during Quick Setup
Refrigerant Probe Length Bottom Dead Zone
non-flammable refrigerants - including [mm] [mm] Reference point
500
ammonia and CO2 800 Top dead zone
1000 120 mm (4.7 in.) 20 mA
CO2 1200 170 (100 %)*
 Oil proof. Oil layer at the bottom of the 1500
stand pipe (ammonia) does not affect the 1700
2200
liquid refrigerant level.
Code number Probe Length Code no.
with HMI [mm]
AKS 4100 - Coaxial 500 084H4510

Inner length of the stand pipe


AKS 4100 - Coaxial 800 084H4511

diameter: 2-4 in.

4 mA (0 %)*
HMI Service/Display unit Technical overview of AKS 4100

Measuring range

Probe length*
AKS 4100 - Coaxial 1000 084H4512

Distance
Standpipe
AKS 4100 - Coaxial 1200 084H4513
The optional HMI Service/Display unit is  Available lengths:
AKS 4100 - Coaxial 1500 084H4514
used for commissioning and quick on-site Cable: 800-5000 mm
setup. and is easily connected to the AKS Coaxial: 500-2200 mm AKS 4100 - Coaxial 1700 084H4515

4100. (other lengths upon request) AKS 4100 - Coaxial 2200 084H4516

* Values to be entered into HMI Quick Setup menu and recorded on Surface level
 Mechanical process connection:
The service unit supports multiple the setting label. Stick the setting label onto the Signal Converter
G1” or ¾” NPT either inside or outside.
languages and both SI and Imperial units.
 Temperature range: Please note: It is mandatory to input dielectric constant for CO2
The LCD display has a resolution of 128 x –60°C/100°C (–76°F/212°F) applications.
64 pixels.  Pressure range: Bottom dead zone
–1 barg / 100 barg (see tables)
Min: 30 mm (1.2 in.)
(–14.5 psig / 1450 psig)
 Standard signal: 4 - 20 mA Ø2 mm (0.08 in.)
stainless wire
 2-wire loop powered; no Danfoss
M84H0026_1

separate transformer needed


For further details, please see the technical literature.
Danfoss FlexlineTM
Simple. Efficient. Flexible.
Designed to offer clever simplicity, timesaving efficiency and advanced flexibility the FlexlineTM series
includes three popular product categories:

ICV Flexline™ ICF Flexline™ SVL Flexline™


– Control valves – Complete valve stations – Line components

All products are based on a modular design with no functionality in the housing. This set-up reduces
complexity right from the design phase to the installation, commissioning and service. All key to
lower total life cycle costs – and major savings.

Go to www.danfoss.com/flexline for more information on the FlexlineTM platform.

Global knowhow
Local support
Backed by more than 60 years of experience producing valves and controllers for industrial refrigeration
applications Danfoss is a solid partner to turn to when you are looking for quality components.

Our global knowhow combined with local support offers you the best possible products and service.

www.danfoss.com/IR

DKRCI.PB.SC0.B1.02 / 520H6568 Produced by Danfoss AC-MCI/BHU. 2012-08