Professional Documents
Culture Documents
Pipe
Phase Fluid Sand presence Condition
NB
Gas &
Two phase No/NA Pressurized service NA
Liquid
Output data:
Max. allowed
ΔP
Vmax Vmin Mach no. criteria back Referred standard Remarks
criteria
pressure
0.6 m/s
Single Reciprocating pump (≤ 2 ft/s (typical (typical flow API 14E, 5th
3 phase Liquid No/NA 250 rpm) suction flow velocities) velocities) NA NA NA NA NA Edition NA
0.5 m/s
Single Reciprocating pump (251 1.5 ft/s (typical (typical flow API 14E, 5th
4 phase Liquid No/NA - 330 rpm) suction flow velocities) velocities) NA NA NA NA NA Edition NA
0.3 m/s
Single Reciprocating pump (> 1 ft/s (typical (typical flow API 14E, 5th
5 phase Liquid No/NA 330 rpm) suction flow velocities) velocities) NA NA NA NA NA Edition NA
0.9 m/s
Single 3 ft/s (typical (typical flow API 14E, 5th
6 phase Liquid No/NA Centrifugal pump suction flow velocities) velocities) NA NA NA NA NA Edition NA
1.8 m/s
Single Reciprocating pump (≤ 6 ft/s (typical (typical flow API 14E, 5th
7 phase Liquid No/NA 250 rpm) discharge flow velocities) velocities) NA NA NA NA NA Edition NA
1.4 m/s
Single Reciprocating pump (251 4.5 ft/s (typical (typical flow API 14E, 5th
8 phase Liquid No/NA - 330 rpm) discharge flow velocities) velocities) NA NA NA NA NA Edition NA
0.9 m/s
Single Reciprocating pump (> 3 ft/s (typical (typical flow API 14E, 5th
9 phase Liquid No/NA 330 rpm) discharge flow velocities) velocities) NA NA NA NA NA Edition NA
2.7 m/s
Single Centrifugal pump 9 ft/s (typical (typical flow API 14E, 5th
10 phase Liquid No/NA discharge flow velocities) velocities) NA NA NA NA NA Edition NA
12
Deoxygena
Single ted sea Norsok standard
21 phase water No/NA Pressurized service 19.7 ft/s 6 m/s NA NA NA NA NA P-001, 5th Edition NA
Deoxygena
Single ted sea Norsok standard
26 phase water No/NA Pressurized service 23 ft/s 7 m/s NA NA NA NA NA P-001, 5th Edition NA
Deoxygena
Single ted sea Norsok standard
31 phase water No/NA Pressurized service 9.8 ft/s 3 m/s 1 m/s NA NA NA NA P-001, 5th Edition NA
Deoxygena
Single ted sea Norsok standard
36 phase water No/NA Pressurized service 19.7 ft/s 6 m/s NA NA NA NA NA P-001, 5th Edition NA
<
Single 200000 Norsok standard Both conditions to be
46 phase Gas No/NA Flare line NA NA NA NA kg/ms2 < 0.6 P-001, 5th Edition satisfied
Total standard
Single GS-EP-SAF-228A,
48 phase Liquid Yes Drain line NA NA 0.8 m/s NA NA NA NA Revision 02 NA
Total standard
Single Drain line with heavy GS-EP-SAF-228A,
49 phase Liquid Yes amount of sand NA NA 1.2 m/s NA NA NA NA Revision 02 NA
Total standard
Single GS-EP-SAF-228A,
50 phase Liquid Yes Drain line (oil free) 9.8 ft/s 3 m/s 0.8 m/s NA NA NA NA Revision 02 NA
Total standard
Single Drain line (oil GS-EP-SAF-228A,
51 phase Liquid Yes contaminated) 4.9 ft/s 1.5 m/s 0.8 m/s NA NA NA NA Revision 02 NA
Total standard
Single Drain line (domestic GS-EP-SAF-228A,
52 phase Liquid Yes sewage) 4.9 ft/s 1.5 m/s 0.8 m/s NA NA NA NA Revision 02 NA
Total standard
Single Pump suction (non- < 3.5 GS-EP-ECP-103,
57 phase Liquid No/NA boiling liquid) 3 ft/s 0.9 m/s NA bar/km NA NA NA Revision 02 NA
Total standard
Single Pump suction (non- < 3.5 GS-EP-ECP-103,
58 phase Liquid No/NA boiling liquid) 3.9 ft/s 1.2 m/s NA bar/km NA NA NA Revision 02 NA
Total standard
Single Pump suction (non- < 3.5 GS-EP-ECP-103,
59 phase Liquid No/NA boiling liquid) 4.9 ft/s 1.5 m/s NA bar/km NA NA NA Revision 02 NA
Total standard
Single Pump suction (non- < 3.5 GS-EP-ECP-103,
60 phase Liquid No/NA boiling liquid) 5.9 ft/s 1.8 m/s NA bar/km NA NA NA Revision 02 NA
Total standard
Single Pump discharge < 4.5 GS-EP-ECP-103,
61 phase Liquid No/NA (pressure < 50 barg) 14.8 ft/s 4.5 m/s NA bar/km NA NA NA Revision 02 NA
Total standard
Single Pump discharge < 4.5 GS-EP-ECP-103,
62 phase Liquid No/NA (pressure < 50 barg) 14.8 ft/s 4.5 m/s NA bar/km NA NA NA Revision 02 NA
Total standard
Single Pump discharge < 4.5 GS-EP-ECP-103,
63 phase Liquid No/NA (pressure < 50 barg) 14.8 ft/s 4.5 m/s NA bar/km NA NA NA Revision 02 NA
Total standard
Single Pump discharge < 4.5 GS-EP-ECP-103,
64 phase Liquid No/NA (pressure < 50 barg) 19.7 ft/s 6 m/s NA bar/km NA NA NA Revision 02 NA
Total standard
Single Pump discharge <9 GS-EP-ECP-103,
65 phase Liquid No/NA (pressure > 50 barg) 14.8 ft/s 4.5 m/s NA bar/km NA NA NA Revision 02 NA
Total standard
Single Pump discharge <9 GS-EP-ECP-103,
66 phase Liquid No/NA (pressure > 50 barg) 14.8 ft/s 4.5 m/s NA bar/km NA NA NA Revision 02 NA
Total standard
Single Pump discharge <9 GS-EP-ECP-103,
67 phase Liquid No/NA (pressure > 50 barg) 14.8 ft/s 4.5 m/s NA bar/km NA NA NA Revision 02 NA
Total standard
Single Pump discharge <9 GS-EP-ECP-103,
68 phase Liquid No/NA (pressure > 50 barg) 19.7 ft/s 6 m/s NA bar/km NA NA NA Revision 02 NA
Pump discharge
(pressure < 50 barg and Total standard
Single Storage tank inlet or in < 4.5 GS-EP-ECP-103,
69 phase Liquid No/NA loading) 9.8 ft/s 3 m/s NA bar/km NA NA NA Revision 02 NA
Pump discharge
(pressure < 50 barg and Total standard
Single Storage tank inlet or in < 4.5 GS-EP-ECP-103,
70 phase Liquid No/NA loading) 9.8 ft/s 3 m/s NA bar/km NA NA NA Revision 02 NA
Pump discharge
(pressure < 50 barg and Total standard
Single Storage tank inlet or in < 4.5 GS-EP-ECP-103,
71 phase Liquid No/NA loading) 9.8 ft/s 3 m/s NA bar/km NA NA NA Revision 02 NA
Pump discharge
(pressure < 50 barg and Total standard
Single Storage tank inlet or in < 4.5 GS-EP-ECP-103,
72 phase Liquid No/NA loading) 9.8 ft/s 3 m/s NA bar/km NA NA NA Revision 02 NA
Pump discharge
(pressure > 50 barg and Total standard
Single Storage tank inlet or in <9 GS-EP-ECP-103,
73 phase Liquid No/NA loading) 9.8 ft/s 3 m/s NA bar/km NA NA NA Revision 02 NA
Pump discharge
(pressure > 50 barg and Total standard
Single Storage tank inlet or in <9 GS-EP-ECP-103,
74 phase Liquid No/NA loading) 9.8 ft/s 3 m/s NA bar/km NA NA NA Revision 02 NA
Pump discharge
(pressure > 50 barg and Total standard
Single Storage tank inlet or in <9 GS-EP-ECP-103,
75 phase Liquid No/NA loading) 9.8 ft/s 3 m/s NA bar/km NA NA NA Revision 02 NA
Pump discharge
(pressure > 50 barg and Total standard
Single Storage tank inlet or in <9 GS-EP-ECP-103,
76 phase Liquid No/NA loading) 9.8 ft/s 3 m/s NA bar/km NA NA NA Revision 02 NA
Total standard
Single 2 ft/s normal 0.6 m/s normal < 0.45 GS-EP-ECP-103,
77 phase Liquid No/NA Drain line velocity velocity NA bar/km NA NA NA Revision 02 NA
Total standard
Single GS-EP-ECP-103,
78 phase Liquid No/NA Sea water lines 11.5 ft/s 3.5 m/s 2 m/s NA NA NA NA Revision 02 NA
Total standard
Single GS-EP-ECP-103,
79 phase Liquid No/NA Steam condensate return 4.9 ft/s 1.5 m/s NA NA NA NA NA Revision 02 NA
Total standard
Single <1 GS-EP-ECP-103,
94 phase Steam No/NA P ≤ 10 barg, L ≤ 200 m NA NA NA bar/km NA NA NA Revision 02 NA
Total standard
Single < 0.25 GS-EP-ECP-103,
95 phase Steam No/NA P ≤ 10 barg, L > 200 m NA NA NA bar/km NA NA NA Revision 02 NA
Total standard
Single 10 < P ≤ 30 barg, L ≤ 200 < 2.3 GS-EP-ECP-103,
96 phase Steam No/NA m 138 ft/s 42 m/s NA bar/km NA NA NA Revision 02 NA
Total standard
Single 10 < P ≤ 30 barg, L > 200 <1 GS-EP-ECP-103,
97 phase Steam No/NA m 138 ft/s 42 m/s NA bar/km NA NA NA Revision 02 NA
Total standard
Single < 2.3 GS-EP-ECP-103,
98 phase Steam No/NA P > 30 barg, L ≤ 200 m 98 ft/s 30 m/s NA bar/km NA NA NA Revision 02 NA
Total standard
Single <1 GS-EP-ECP-103,
99 phase Steam No/NA P > 30 barg, L > 200 m 98 ft/s 30 m/s NA bar/km NA NA NA Revision 02 NA
ρm is apparent density,
Total standard Vm is apparent fluid
Two Gas & Continuous operating (P < 6000 GS-EP-ECP-103, velocity and to be used
100 phase Liquid No/NA ≤ 20 barg) NA NA NA NA kg/ms2 NA NA Revision 02 for is
ρ ρmapparent
*Vm2 calculations
density,
m
ρm is apparent density,
Dis-continuous operating Total standard Vm is apparent fluid
Two Gas & - compressor anti-surge < 10000 GS-EP-ECP-103, velocity and to be used
105 phase Liquid No/NA (P ≤ 50 barg) NA NA NA NA kg/ms2 NA NA Revision 02 for is
ρ ρmapparent
*Vm2 calculations
density,
m
ρm is apparent density,
Dis-continuous operating Total standard Vm is apparent fluid
Two Gas & - compressor suction (P < 10000 GS-EP-ECP-103, velocity and to be used
108 phase Liquid No/NA ≤ 50 barg) NA NA NA NA kg/ms2 NA NA Revision 02 for
ρ isρmapparent
*Vm2 calculations
density,
m
ρm is apparent density,
Dis-continuous operating Total standard Vm is apparent fluid
Two Gas & - compressor discharge < 10000 GS-EP-ECP-103, velocity and to be used
111 phase Liquid No/NA (P ≤ 50 barg) NA NA NA NA kg/ms2 NA NA Revision 02 for
ρ isρmapparent
*Vm2 calculations
density,
m
Total standard
Single Upstream of relieving ≤ 25000 GS-EP-ECP-103,
114 phase Flare gas No/NA device, Line size ≤ 2" NA NA NA NA kg/ms2 NA NA Revision 02 NA
Total standard
Single Upstream of downstream ≤ 50000 GS-EP-ECP-103,
118 phase Flare gas No/NA device, Continuous flow NA NA NA NA kg/ms2 < 0.35 NA Revision 02 NA
Compiled by:
Ajay S. Satpute
M. Tech. (Chemical)
IIT, Madras