You are on page 1of 9

Auxiliary reinforcement around column without joints

PLAN

LEGEND

Mesh 150 x 150 x 8 x 8


Dim.: 1.6 x 2 m

Compressible material
thickness 20 mm
Auxiliary reinforcement
5 x ¤ 12 mm – Length: 1.5 m.

Dramix reinforced concrete

Mesh supports: Height dependent on floor


thickness. Allow for 50 mm concrete cover
above mesh

CROSS SECTION

Dramix Steel Fibers


Auxiliary reinforcement around column with 2 construction joints

PLAN

LEGEND

Mesh 150 x 150 x 8 x 8


Dim.: 1 x 1 m

Construction joint
Type omega

Compressible material
thickness 20 mm

Auxiliary reinforcement
5 x ¤ 12 mm – Length: 1.5 m.

Dramix reinforced concrete

Anchorage every 500 mm

Mesh supports: Height dependent on


floor thickness. Allow for 50 mm
concrete cover above mesh.

CROSS SECTION

Dramix Steel Fibers


Auxiliary reinforcement around column with one construction joint
PLAN

LEGEND

Mesh 150 x 150 x 8 x 8


Dim.: 1.6 x 2 m

Construction joint
Type omega

Compressible material
thickness 20 mm

Auxiliary reinforcement
5 x ¤ 12 mm – Length: 1.5 m.

Dramix reinforced concrete

Anchorage every 500 mm

Mesh supports: Height dependent


on floor thickness. Allow for 50 mm
concrete cover above mesh.

CROSS SECTION

Dramix Steel Fibers


Auxiliary reinforcement around column at the edge

PLAN

LEGEND

Mesh 150 x 150 x 8 x 8


Dim.: 1.6 x 2 m

Compressible material
Thick: 20 mm (column) - 10 mm (wall)

Auxiliary reinforcement
5 x ¤ 12 mm – Length: 1.5 m.

Dramix reinforced concrete

Mesh supports: Height dependent


on floor thickness. Allow for 50 mm
concrete cover above mesh.

CROSS SECTION

Dramix Steel Fibers


Auxiliary reinforcement around column at the edge
PLAN

LEGEND

Mesh 150 x 150 x 8 x 8


Dim.: 1.6 x 2 m.

Compressible material
Thick: 20 mm (column) - 10 mm (wall)

Auxiliary reinforcement
5 x ¤ mm – Length: 1.5 m.

Dramix reinforced concrete

Mesh supports: Height dependent


on floor thickness. Allow for 50 mm
concrete cover above mesh.

CROSS SECTION

Dramix Steel Fibers


Auxiliary reinforcement around column at the edge
with 1 construction joint

PLAN

LEGEND

Mesh 150 x 150 x 8 x 8


Dim.: 1 x 1 m

Construction joint with dowels

Compressible material
Thick: 20 mm (column) - 10 mm (wall)

Auxiliary reinforcement
5 x ¤ 12 mm – Length: 1.5 m.

Dramix reinforced concrete

Mesh supports: Height dependent


on floor thickness. Allow for 50 mm
concrete cover above mesh.

CROSS SECTION

Dramix Steel Fibers


Auxiliary reinforcement around an inspection shaft

PLAN

LEGEND

Mesh 150 x 150 x 8 x 8


Dim.: 1.6 x 2 m.

Compressible material
thickness 20 mm

Auxiliary reinforcement
3 x ¤ 12 mm – Length: 1.5 m.

Dramix reinforced concrete

Mesh supports: Height dependent


on floor thickness. Allow for 50 mm
concrete cover above mesh.

Concrete

Anchorage every 500 mm

CROSS SECTION

Dramix Steel Fibers


Auxiliary reinforcement at corners

CROSS SECTION LEGEND

1.5 m Mesh 150 x 150 x 8 x 8


Dim.: 2.0 x 2.5 m.
L/2 L/2
Compressible material
thickness 10 mm

Auxiliary reinforcement
10 x ¤ 12 mm – Length: 1.5 m.
concrete coverage = 5 cm

Dramix reinforced concrete

Wall

Expansion joint
Type omega

Dramix Steel Fibers


Auxiliary reinforcement at docking boards

PLAN

LEGEND

Mesh 150 x 150 x 8 x 8

Dramix reinforced concrete

Wall

Distancers: Height in function of the


floorthickness by a 50 mm concrete
coverage of the re-bars.

CROSS SECTION

Dramix Steel Fibers

You might also like