You are on page 1of 10

LGS Home Elevator

rJ@
I PLANNING GUIDE I Home Elevator Function List
No Function description
In automatic running or attendant state, this function enables the elevator to respond both car
HW 01 Full collective selective calls and hall calls. Passengers at any service floor can call the elevator by pressing the up call
HW button and down call button.
The system automatically determines different door open time for door open for call, command,
02 Door open time setting
protection, or delay according to the set door open holding time.

0>LU
In automatic running state, passengers can press the door open button in the car to delay door

H�/1
03 Doo『 open delay
open to facilitate goods to be moved in or out.

LU
0
Floor number The system supports display of floor numbers in combinations of numbers and letters, which

OH
QH

04
display settinq meets the requirements of special conditions.
Independent control
When there are two doors for a car, automatic control on the two doors depends on your
05 of the front door and
requirements.
back door
If the door lock is not applied after the elevator performs door close for a certain time, the
06 Repeat door close
elevator automatically opens the door and then closes the door again.

느士)
The systems implements automatic accurate leveling based on the floor pulse counting and
1 Car-1 Ent 1 Car-2Ent 07 Auto-leveling
up/down leveling feedback signals.

13H l>MOL
(2P-CO) (2P-CO) - - ----= = = Idle elevator returning In automatic running state, the elevator automatically returns to the set parking floor and waits
--== -- ---== 08
to base floor for passengers if there is no car call or hall call within the set time.
二::
When the elevator is in non-inspection state and stops at non-leveling area, the elevator
HW 09 Low-speed self-rescue automatically runs to the leveling area at low speed if the safety requirements are met, and
then opens the door.
10 Car arrival gong After the elevator arrives at the destination floor, the CTB gives a prompt tone.

TUJ
i\VlU
Automatic door open If the system detects that the door lock circuit is abnormal during door open/close, the elevator
11 upon door lock automatically opens and closes the door again, and reports a fault after the set door open/close
abnormality times is reached.
+
OH

lH"
+ 12 Overload protection When the car load exceeds the rated elevator load, the elevator alarms and stops running.
lNW

� The system automatically records detailed information of faults, which helps improve the
13 Fault data recording
efficiency of maintenance and repair.
Returning to base floor After receiving a fire emergency signal, the elevator does not respond to any call but directly
14
at fire emergency runs to the fire emergency floor and waits.
The system detects the running state of the elevator in real time. If the elevator speed exceeds
15 Elevator lock
1 Car-1 Ent 1 Car-2Ent the limit, the system immediately stops running of the elevator.
For the synchronous motor, when the power supply is interrupted, the system can perform
(2P-25) (2P-2S) Automatic running automatic switchover between shorting stator braking mode and controller drive mode,
16 mode switchover at implementing quick and stable self-rescue. Shorting stator braking mode: Upon power failure,
power failure UPS is used, the motor stator is shorted, and the brake is automatically released, making the car
move slowly under the effect of the weighing difference between the car and the counterweight.
[unit: mm] Product Specification If there is no running command within the set time, the system automatically cuts off the power

I
17 Car energy-saving
Traction Method with Belt Traction Roped Traction supply to the lamp and fan in the ca『.
Load Speed no. of OP CAR SIZE HOISTWAY coated steel belt with steel wire rope
Opening Energy-saving running When the normal powe『 supply is interrupted and the emergency powe『 supply is used, the
kg m/s type OP*EH CW HW HD Traction machine PMSM Gearless
CD
Rated Load 250kg / 320kg / 400kg / 450kg 18 with standby power system reduces the running speed of the elevato『 in the prerequisite of guaranteeing the
1 Car 1Ent
co 700*2000 900 1100 1600 1450 No of passengers 3-5persons supply smooth running curve.
2S 800*2000 900 1100 1480 1500 Speed 04m/s Arrival gong disabled
250kg 0.4 19 Within the set time period, the arrival gong is disabled
1Car-2Ent
co 700*2000 900 1100 1600 1600 Travel Max25meler at night
Overhead 2900mm(Min.)/3100mm(Std.) I 3200mm(Min.)/3400mm(Std.)
2S 800*2000 900 1100 1480 1730
Min PIT �400mm
co 700*2000 900 1200 1600 1550 Main Power AC220V 50Hz- 1 phase /AC380V 50Hz- 3 phase
1Car 1Ent
2S 800*2000 900 1200 1480 1600 Door Opening Automatic sliding door (2P-CO, 2P-2S)
320kg 0.4
1Car-2Ent
co
2S
700*2000
800*2000
900
900
1200
1200
1600
1480
1700
1830
Hoistway Concrete I Steel frame
I Home Elevato『 Power Plan
co 700*2000 1000 1200 1650 1550 Load Speed Motor Capa. Motor Current Input Rated N.F.B Tran sformer Lead-in Wire Earth Wire
co 700*2000 1100 1300 1700 1650
(kg) Voltage [m뻐
2
1Car 1Ent [m/s] [kW] [220V] [ A] [kVA] [mm ]
2S 800*2000 1000 1200 1580 1600
400kg 2S 900*2000 1100 1300 1680 1700 250 0.96 5.6A 16 3.9 4 4
0.4
(450kg) co 700*2000 1000 1200 1650 1700
co 700*2000 1100 1300 1700 1800 320 0.96 5.6A CD1-AC220 16 3.9 4 4
1Car 2Ent 0.4
2S 800*2000 1000 1200 1580 1830 400 1.1 6.5A /50Hz 16 3.9 4 4
2S 900*2000 1100 1300 1680 1930
Note 450 1.3 7.4A 16 3.9 4 4
1) Standard Car & Landing door Height should be 2000mm
2) Cab Height (CH) should be 2100mm

Note Note
The printed image might be different from actual product. The printed image might be different from actual product

15 16
ELEVATOR CONFIRMATION SHEET MEMO
CAR DESIGN SELECTION

Q'ty:
Date: +MQTQVO
Confirmed by Customer:

Elevator type : Home Elevator +78

Rated Speed: 0.4 m/s (24m/min)


+IZ?ITT[QLM
Rated Load: [kg]
No. of Building Floor;
+IZLWWZ
No. of Stop:
Total Height [ ]
= Travel + OH + PIT =[ ]+[ ]+[ ]
CAR DESIGN type
.TWWZ
Ceiling Type
Car Wall
Car Door .ZWV\>QM_
Car

Hand Rail
Etching No.
Interior Film no.
Flooring
COP button type +IZ?ITTZMIZ

Ground FL TYP.FLs
Landing Material
0IVL:IQT
Landing

Door Etching No.


Type narrow narrow
JAMB
Material
LOP type

Reamrk & Options


:MIZ>QM_

LANDING SELECTION

2)5*VIZZW_

4IVLQVO,WWZ

0ITT1VLQKI\WZ
*]\\WV
LOP

 

You might also like