DEMAN
CAPACITY
INPUT
No EQUIPMENT Normal Sea Going
Normal Rate Total
(kW) (set) KW set %
Machinery Part
1 Air Compressor 6.00 1 7.50
2 Bilga/Ballast Pump 4.00 1 4.40
3 Fire And G.S Pump 4.00 1 4.60
4 Sea Water Hydrophore Pump 1.00 1 1.10 1 30%
5 Fresh Water Hydrophore 1.00 1 1.30 1 30%
6 F.O. Transfer Pump 0.50 1 0.60 1 70%
7 Oily Water Sparator (marpol 1m3/jam) 0.40 1 0.50 1 80%
8 Sewage Pump 0.40 1 0.50 1 60%
9 Engine Room Supply Fan 2.00 1 2.30 1 80%
10 Engine Room Exhaust Fan 2.00 1 2.50 1 80%
11 A.C Seawater Cooling (1 st-by) 1.50 2 1.90 1 80%
12 M.E Sea Water Cooling Pump (1 st-by) 4.00 2 5.00 1 80%
SUB TOTAL
Hull Part
1 Steering Gear 5.00 1 5.60 1 50%
2 Steering Gear Room Supply Fan 0.50 1 0.60 1 80%
3 Supply Fan For Whellhouse (backhouse) 1.50 2 1.70 1 80%
4 AC Package (Central Unit) @ 50000 BTU (1 st-by) 8.00 2 8.40 1 80%
5 Galley & Laundry Equipment 5.00 1 5.90 1 50%
6 Electrical Hydraulic Anchor Windlass 7.50 1 8.30 1 50%
7 Exhaust Fan (2 toilet + Galley + Laundry + AHU) 1.50 5 1.70 5 30%
SUB TOTAL
Electric Part
1 E/R Light 1.00 1 1.00 - 80%
2 Accomodation Lights 1.10 1 1.10 - 65%
3 Navigation Lights 0.40 1 0.40 - 30%
4 Outside & Flood Lights 1.20 1 1.20 1 60%
5 Search Lights 0.40 2 0.70 1 50%
6 Internal Communication 2.00 1 2.00 1 75%
7 Radio, Nautical system & Inmarsat 5.00 1 5.00 1 75%
8 ATM Machine & Miscellaneous 6.00 1 6.00 1 80%
SUB TOTAL
Note: C.L = Continuous Load
I.L = Intermittent Load
1 30% - 2.25
1 50% - 2.2
1 30% - 1.38
- 0.33 1 60% - 0.66 1 60% - 0.66
- 0.39 1 60% - 0.78 1 80% - 1.04
- 0.42 1 70% - 0.42 1 50% - 0.3
- 0.40 1 70% - 0.35 1 50% - 0.25
- 0.30
1.84 - 1 80% 1.84 - 1 80% 1.84 -
- 2.00 1 80% - 2 1 80% - 2
1.52 - 1 80% 1.52 - 1 80% 1.52 -
4 - 1 80% 4 - 1 80% 4 -