Form No. 11.20(DQM)F-19 Rev.
01
IC No. : 05.20.23U2.00387.IC.01
Regd. office : Doranda, Ranchi -834002; Jharkhand, India. Tel : +91 651 2482183; Fax : +91 651 2482214 Date : 22-Apr-2021
CIN No. INSPECTION CERTIFICATE Page 1 of 3
U74140JH1973GOI001199
Client : GAIL (India) Limited - Assam Project : 23U2 - EPMC Services for Barauni
Guwahati Pipeline Project - Engineering
S46 - PROCUREMENT OF LR Date of 12th April, 2021 & 13th April, 2021.
Package :
BENDS FOR BGPL PROJECT Inspection :
M/S LALIT ROHAR FITTINGS Contractor FOA NO.
Contractor :
(P) LTD. PO No. & date : 05.51.23U2.GAIL.015-R.FOA.719,
dated: 19-Dec-2020
Sub Contractor : Manufacturer : LALIT ROHR FITTINGS PVT LTD
LALIT ROHR FITTINGS PVT LTD
SAVLI- VADODARA, GUJARAT
Place of
PLOT NO-360, SAVLI- KARCHIA Inspecting Delhi
Inspection : Office :
ROAD
TALUKA-SAVLI, VADODARA,
GUJARAT
LRFPL/20-69/05, dated: Assignment 05.20.23U2.I.00387
Call no. :
01-Apr-2021 No. :
Hard copy received on : 01-April-2021
Following Items are inspected as per inspection documents in accordance with P.O specification and/or approved QAP
/ datasheet / drawing etc. ( as applicable ) and are accepted
B.S No. / Quantity
Item Description Unit
Equip. Id No. Total
Offered Accepted
Ordered
PRODUCTION 12” OD x 10.31 MM WT x 6D No, 20 20 20
BENDS BENDS, API 5L 415M {X 6OM} No 20 20 20
PSL 2 HFW
Identification Stamping : ¨ Yes þ No Type of Stamping :
Nil ¨ Punching ¨ Stenciled ¨ Sticker
Stamping Location : Rubber Stamp
¨
Specimen of Stamping :
Sampling Done :
¨ As per IS/IEC/ASTM/DIN/API/JEC/IEEE other standard
þ As per QAP ¨ 100 percent
¨ Other
SUB-CONTRACTOR/ PURCHASER / CLIENT'S
CONTRACTOR MECON
MANUFACTURER REPRESENTATIVE
Signature : Signature : Signature : Signature :
Name & Designation : Name & Designation : Name & Designation : Name & Desig : Harpreet
Singh, General Manager
(Project), Inspection & QA,
Note: 1.Acceptance of above equipment does in no way absolve the responsibilities of the contractor to supply and install the plant and equipment as
per T.S/Contract.
2.The issue of this Certificate by MECON or its authorised representative shall not bind Purchaser/MECON to accept the product should it on
further check /test before/during/after erection, be found not comply with the requirements of the contract.
Website: http://www.meconlimited.co.in; Email : inspranchi@meconlimited.co.in
Form No. 11.20(DQM)F-19 Rev.01
IC No. : 05.20.23U2.00387.IC.01
Regd. office : Doranda, Ranchi -834002; Jharkhand, India. Tel : +91 651 2482183; Fax : +91 651 2482214 Date : 22-Apr-2021
CIN No. INSPECTION CERTIFICATE Page 2 of 3
U74140JH1973GOI001199
Remarks : A} This Inspection Certificate is being Issued for 20 Nos. Long Radius Bends made from Welspun
manufactured Steel Pipes by M/s Lalit Rohr Fittings Pvt. Ltd. and offered for Inspection subsequently.
B} This Inspection Certificate is being Issued based on following Inspection Documents Issued Before/
During & After Inspection and submitted via Email by M/s Lalit Rohr Fittings Pvt. Ltd.:
1} M/s Lalit Rohr Fittings Material Identification Report Dated: 24.02.2021.
2} M/s Welspun Inspection Certificate as per EN 10204: 2004 Type 3.2 Dated: 08.06.2015 along with Pipe
Annexures of the same Date.
3} PQT Reports consisting of Sample Identification Report, Visual & Dimensional Inspection Report,
Ultrasonic Examination Report, Magnetic Particle Inspection Report & Hydro Test Report of the PQT
Bend.
4} Metheat Engineers Pvt. Ltd. following Test Reports of the Samples drawn from the PQT Bend:
A] Chemical Analysis {Spectro FE Base} Report
B} Tensile Test for finding out the Values of the following Technical Parameters:
1) Yield Strength
2) Ultimate Tensile Strength
3) Elongation %
4) V-Notch Charpy Impact Test
5) Reverse Bend Test
6) Vickers Hardness Test
5} TUV India Private Limited Inspection Release Note/ Certificate No.: IRN - 010102021321, Rev.: 00,
Dated: 15.04.2021.
6} M/s Lalit Rohr Fittings Test Certificate as per EN 10204 Clause 3.2 {TC No.: LRFPL/ PB/ MECON -
GAIL/ 20 - 69/ 03, R - 0, Dated: 15.04.2021.
7} MECON Inspection Report No.: 05. 20. 23U2. GAIL. LRFPL. LRB. 001, Dated: 13.04.2021
8} Following Inspection Reports of the Production Bends:
A) Bending Parameters Report {Temperature & Speed Monitoring Report}.
B) Visual & Dimensional Inspection Report {Bend Angle, Inside Diameter, Thickness at Extrados,
Ovality, Nominal Bend Radius, Actual Outer Arc Length, Tangent Lengths including Pig Test & Visual
Inspection}.
C} Surface Hardness Test Report.
SUB-CONTRACTOR/ PURCHASER / CLIENT'S
CONTRACTOR MECON
MANUFACTURER REPRESENTATIVE
Signature : Signature : Signature : Signature :
Name & Designation : Name & Designation : Name & Designation : Name & Desig : Harpreet
Singh, General Manager
(Project), Inspection & QA,
Note: 1.Acceptance of above equipment does in no way absolve the responsibilities of the contractor to supply and install the plant and equipment as
per T.S/Contract.
2.The issue of this Certificate by MECON or its authorised representative shall not bind Purchaser/MECON to accept the product should it on
further check /test before/during/after erection, be found not comply with the requirements of the contract.
Website: http://www.meconlimited.co.in; Email : inspranchi@meconlimited.co.in
Form No. 11.20(DQM)F-19 Rev.01
IC No. : 05.20.23U2.00387.IC.01
Regd. office : Doranda, Ranchi -834002; Jharkhand, India. Tel : +91 651 2482183; Fax : +91 651 2482214 Date : 22-Apr-2021
CIN No. INSPECTION CERTIFICATE Page 3 of 3
U74140JH1973GOI001199
D} Ultrasonic Examination Report.
E} Magnetic Particle Inspection Report.
F} Painting & Marking Report.
SUB-CONTRACTOR/ PURCHASER / CLIENT'S
CONTRACTOR MECON
MANUFACTURER REPRESENTATIVE
Signature : Signature : Signature : Signature :
Name & Designation : Name & Designation : Name & Designation : Name & Desig : Harpreet
Singh, General Manager
(Project), Inspection & QA,
Note: 1.Acceptance of above equipment does in no way absolve the responsibilities of the contractor to supply and install the plant and equipment as
per T.S/Contract.
2.The issue of this Certificate by MECON or its authorised representative shall not bind Purchaser/MECON to accept the product should it on
further check /test before/during/after erection, be found not comply with the requirements of the contract.
Website: http://www.meconlimited.co.in; Email : inspranchi@meconlimited.co.in