TECHNICAL MANUAL

DANA TE17 FF TRANSMISSION

ORIGINAL INSTRUCTIONS
X158715en / B / 18 Jan 2016
TM Transmission TE 17 FF.01en
This document and the information contained herein, is the exclusive property of Konecranes Lifttrucks and represents a non-public, confidential and proprietary trade secret that may not be
reproduced, disclosed to other parties, altered or otherwise employed in any manner whatsoever without the express written consent of Konecranes Lifttrucks. © 2016 Konecranes Lifttrucks. All rights
reserved. ‘Konecranes’, ‘Lifting Businesses’ and C are either registered trademarks or trademarks of Konecranes Lifttrucks.
TABLE OF CONTENTS TECHNICAL MANUAL

TABLE OF CONTENTS
1 DANA TE 17 FULL FLOW......................................................................................... 5
1.1 Technical specification............................................................................................ 6
1.2 Operation.................................................................................................................. 7
1.2.1 Main assemblies.......................................................................................... 7
1.2.2 Transmission cooler..................................................................................... 8
1.2.3 Speed sensor............................................................................................... 8
1.2.4 Temperature sensor..................................................................................... 9
1.2.5 Valves.......................................................................................................... 9
1.2.6 Transmission controls.................................................................................. 10
1.2.7 Hydraulic schematics................................................................................... 12
1.3 Check ports.............................................................................................................. 19
1.4 Control valve............................................................................................................ 21
1.4.1 Disassembly................................................................................................. 21
1.4.2 Assembly..................................................................................................... 22
1.5 Testing...................................................................................................................... 22
1.5.1 Stall test....................................................................................................... 22
1.5.2 Transmission pressure checks..................................................................... 23
1.5.3 Mechanical and electrical checks................................................................. 23
1.5.4 Hydraulic checks.......................................................................................... 23
1.5.5 Speed sensor - static standalone test.......................................................... 23
1.6 Troubleshooting....................................................................................................... 25
1.6.1 Troubleshooting........................................................................................... 25
1.6.2 Troubleshooting for error 42.05.................................................................... 25
1.7 Error codes list......................................................................................................... 27
1.8 Error codes............................................................................................................... 32
1.9 Exceed codes........................................................................................................... 87
1.10 Transmission calibration error codes.................................................................... 89

3/94
This document and the information contained herein, is the exclusive property of Konecranes Lifttrucks and represents a non-public, confidential and proprietary trade secret that may
not be reproduced, disclosed to other parties, altered or otherwise employed in any manner whatsoever without the express written consent of Konecranes Lifttrucks. © 2016
Konecranes Lifttrucks. All rights reserved. ‘Konecranes’, ‘Lifting Businesses’ and C are either registered trademarks or trademarks of Konecranes Lifttrucks.
TECHNICAL MANUAL TABLE OF CONTENTS

4/94
This document and the information contained herein, is the exclusive property of Konecranes Lifttrucks and represents a non-public, confidential and proprietary trade secret that may
not be reproduced, disclosed to other parties, altered or otherwise employed in any manner whatsoever without the express written consent of Konecranes Lifttrucks. © 2016
Konecranes Lifttrucks. All rights reserved. ‘Konecranes’, ‘Lifting Businesses’ and C are either registered trademarks or trademarks of Konecranes Lifttrucks.
1 DANA TE 17 FULL FLOW TECHNICAL MANUAL

1 DANA TE 17 FULL FLOW

SPICER OFF-HIGHWAY
TEN BRIEL E 3
B-8200
BELGIUM

MODEL
SERIAL

Figure 1. DANA TE17 FF

DANA TE17 Full Flow (FF) is a 3 speed transmission controlled by TCon.

Features:
• Flex plate drive
• Long drop and short drop versions
• Electronic Controlled Modulation (ECM)
• Clutch overlap control
• Electronic Controlled Inching (ECI) - (Optional)

Model identification

1X.X Converter model wheel group

T Mounting type - Engine mount

RT Mounting type - Remote mount

MT Mounting type - Mid mount

E Electronically controlled model

17 Model number (Transmission input rating x 100 Nm)

3 Numbers of gears

X Even number - Long drop or odd number - short drop

X Specific ratio or drop

XX Specific dash number, Specific ratio

5/94
X158715en / B / 18 Jan 2016 Copyright © (2016) Konecranes Lifttrucks. All rights reserved.
TM Transmission TE 17 FF.01en
TECHNICAL MANUAL 1 DANA TE 17 FULL FLOW

1.1 Technical specification

Table 1. Oil system

Capacity 16.5 l (without cooler and hydraulic lines)

Oil type Only ATF Dexron III approved

Viscosity At 40°C: 33–38 cSt

At 100°C: 7–8 cSt

Oil change 1000 hours

Oil filter Integrated spin on filter change every 1000 hours

First change or after rebuild: 150 hours

Table 2. Temperature specifications

Normal operating temperature 70ºC–120ºC (158ºF–248ºF) Measured at temperature check


port for cooler

Maximum allowed transmission 120ºC (248ºF)


oil temperature

Table 3. Pressure specifications

Transmission regulator 26 bar minimum at 600 RPM


pressure
31 bar maximum at 2650 RPM

Clutch package pressure 26 bar–30 bar at 2200 RPM

Lube pressure 1.55 bar–2.25 bar at 1500 RPM

Overflow valve Cracking pressure: 7.5 bar

Converter Out Pressure Pressure between 3 bar–3.5 bar

Pump flow 92.1 l/m minimum at 2200 RPM

Lube pump flow Selective lube: 52.4 l/m minimum at 2170 RPM

84.6 l/m maximum at 2910 RPM

NOTE All pressures to be measured with oil temperature 82ºC-93ºC (180ºF–200ºF).

6/94
X158715en / B / 18 Jan 2016 Copyright © (2016) Konecranes Lifttrucks. All rights reserved.
TM Transmission TE 17 FF.01en
1 DANA TE 17 FULL FLOW TECHNICAL MANUAL

1.2 Operation

1.2.1 Main assemblies

1 2 3 5

Figure 2. Main assemblies

1. Torque converter and pump driven section


2. Input shaft and directional clutches
3. Range clutches
4. Output section
5. Transmission control valve

Torque converter and pump driven section


Torque converter is a device that transmits force and motion from engine to transmission with
fluid. Engine power is transmitted from flywheel to the impeller.

Impeller is the pump portion of torque converter. Due to the centrifugal force, impeller rotates
and oil flows outward. This oil strikes the torque converter turbine. Turbine receives oil at its
outer diameter and discharges it at its center.

The reaction member receives oil from turbine and changes direction to allow correct entry for
recirculation into impeller element. This recirculation multiplies the torque. The hydraulic pump
is connected with pump drive gear and it is driven by impeller hub gear.

Input shaft and directional clutches


The turbine shaft transmits power to the directional clutches (fwd/rev). To engage the clutch, the
solenoid directs pressurized oil to the selected clutch shafts.

Oil seals on clutch shafts direct the oil to the desired clutch. When clutch is released oil flows
back to the oil pan. The engagement of all clutches is modulated and electronically controlled.

Range clutches
Once directional clutch is engaged, the power is transmitted to the range clutches.

Output section
With a range clutch engaged, power is finally transmitted to output shaft.

Transmission control valve


The transmission control valve controls the oil flow to various clutches, depending on the gear
selected.

7/94
X158715en / B / 18 Jan 2016 Copyright © (2016) Konecranes Lifttrucks. All rights reserved.
TM Transmission TE 17 FF.01en
TECHNICAL MANUAL 1 DANA TE 17 FULL FLOW

1.2.2 Transmission cooler

1
2

Figure 3. Transmission cooler

Transmission cooler (1) helps to dissipate heat from the transmission oil.

If the temperature of oil is more than 72°C, then the external thermo shuttle valve (2) opens and
allows the oil to flow through the cooler or else, it bypasses the cooler and allows the oil to flow
directly into the transmission.

Hot oil from the transmission flows into the cooler (1) and then flows back to the transmission.

1.2.3 Speed sensor


The speed sensor is a magneto-resistive sensor which generates a square wave current with a
fixed amplitude changing between 7 mA–14 mA. The sensor has an integrated AMP superseal
2-pin connector. The sensing distance is up to 1.8 mm.

Speed sensor installation


X
1 2
1

Teeth
rotation Teeth
rotation

Pin 2 Pin 1 Pin 3 Pin 1

Pin 2

Figure 4. Speed sensor installation

While installing the sensor make sure the position sign (1) on the sensor body points in the
direction of the gear teeth movement. Tighten the screw (2) to 12–15 Nm torque.

Color Pin Number Function Connection

Brown 1 Current input Hot wire

Blue 2 Current output Ground wire

8/94
X158715en / B / 18 Jan 2016 Copyright © (2016) Konecranes Lifttrucks. All rights reserved.
TM Transmission TE 17 FF.01en
1 DANA TE 17 FULL FLOW TECHNICAL MANUAL

1.2.4 Temperature sensor

Pin 2

Pin 1

Figure 5. Temperature sensor

• Material that is used is Silicon.


• Resistance at 25°C (77°F) = 2000 ohm ± 1%

WARNING
MACHINE MALFUNCTION HAZARD
Wrong connections will deactivate the sensor. Deactivated sensor can result in
property damage, serious injury, or death.
Pay attention that the connections are correct.

1.2.5 Valves

5 1

3 2

Figure 6. Valves

1. 1st/3rd pressure sensor 5. 3rd/1st proportional valve


2. 2nd pressure sensor 6. 1st/3rd selector valve
3. 2nd proportional valve 7. FWD/REV selector valve
4. FWD/REV selector valve

9/94
X158715en / B / 18 Jan 2016 Copyright © (2016) Konecranes Lifttrucks. All rights reserved.
TM Transmission TE 17 FF.01en
TECHNICAL MANUAL 1 DANA TE 17 FULL FLOW

Proportional valves: FWD/REV - 1st/3rd - 2nd


• When activated the proportional valve gives an output pressure curve from 0 bar–26 bar
proportional to a current from 0 mA–1000 mA
• Coil resistance : 7.25 ohm at 20°C

Selection valves: FWD/N/REV - 1st/3rd

• Coil resistance : 28.5 ohm at 20°C

Pressure sensor
• Supply voltage 4.5 V–5.5 V
• Maximum current: 10 mA
• Pressure range: 1 bar–31 bar
• ±1.2% full scale (31 bar range 1 bar–25 bar)
• ±2.5% full scale (31 bar range 25 bar–31 bar)

1.2.6 Transmission controls


The transmission is controlled by the control valve. The control valve assembly is mounted
directly on the side of the rear cover. The function of the control valve assembly is to direct oil
under pressure to the desired directional and speed clutches.

Operation of the valve


Regulated pressure 26 bar–31 bar is directed to the proportional valve and selector valves to
activate the required clutches.

When activated the proportional valve gives an output pressure curve from 0 bar–31 bar
proportional to a current from 0 mA–1000 mA. Dampers are used to dampen any hydraulic
vibration.

Directional selection
When a direction (forward or reverse) is selected, the required selector valve is activated for
forward or reverse and the proportional valve provides a pressure rise from 0 bar–31 bar
feeding the directional clutch with modulated pressure.

Range selection
When 1st clutch is selected, the 1st or 3rd selector valve is activated and the 1st or 3rd
proportional valve provides a pressure rise from 0 bar–31 bar feeding the 1st clutch with
modulated pressure.

When 2nd clutch is selected, the 1st or 3rd proportional valve decreases pressure from 31 bar–
0 bar, thus releasing the 1st clutch in a controlled manner.

At the same time, the 2nd proportional valve is activated and provides a pressure curve from 0
bar–31 bar, which provides clutch overlap. When the shift is finalized, the 1st or 3rd selector
valve is deactivated.

When 3rd clutch is selected, the 1st or 3rd selector valve is not activated. The 2nd proportional
valve decreases pressure from 31 bar–0 bar, thus releasing the 2nd clutch in a controlled
manner.

At the same time, the 1st or 3rd proportional valve is activated and provides a pressure curve
from 0 bar–31 bar, which provides clutch overlap.
10/94
X158715en / B / 18 Jan 2016 Copyright © (2016) Konecranes Lifttrucks. All rights reserved.
TM Transmission TE 17 FF.01en
1 DANA TE 17 FULL FLOW TECHNICAL MANUAL

Pressure sensor
The control valve also has a pressure sensors that is installed to monitor overlap on range
clutches.

Electric solenoid controls

Selected gear Activated selector Activated Activated clutches


valve proportional valve

Forward 3 FWD FWD/REV -1st/3rd FWD - 3rd

Forward 2 FWD - 2nd FWD/REV - 2nd FWD - 2nd

Forward 1 FWD - 1st/3rd FWD/REV - 1st/3rd FWD - 1st

Neutral 3 1st/3rd 3rd

Neutral 2 2nd 2nd 2nd

Neutral 1 1st/3rd 1st/3rd 1st

Reverse 3 REV FWD/REV - 1st/3rd REV - 3rd

Reverse 2 REV - 2nd FWD/REV - 2nd REV - 2nd

Reverse 1 REV - 1st/3rd FWD/REV - 1st/3rd REV - 1st

11/94
X158715en / B / 18 Jan 2016 Copyright © (2016) Konecranes Lifttrucks. All rights reserved.
TM Transmission TE 17 FF.01en
12/94
1.2.7
OPERATOR COMPARTMENT
PRESSURE TEMPERATURE
GAUGE GAUGE

TORQUE
37 CONVERTER 32 AA

X158715en / B / 18 Jan 2016


Neutral
TECHNICAL MANUAL

71

TM Transmission TE 17 FF.01en
HOSE COOLER HOSE

LUBRICATION
Hydraulic schematics

TORQUE CONVERTER
SAFETY VALVE
BY-PASS VALVE
9 bar
5 bar DIFFERENTIAL PRESSURE 37

PRESSURE REGULATOR
VALVE 28.5-31.5 bar 41

FWD/REV 1ST/3RD 73 2ND


2ND
TEMPERATURE
1ST/3RD
SENSOR

FWD/N/REV
FILTER FILTER BY-PASS
VALVE
1ST/3RD
Lubrication
42
Low pressure

High pressure

Drain 66 67

PUMP 46 45 41 43
MIN 92,1 L/min @ 2420 rpm CONTROL VALVE
MAX 137,1 L/min @ 2916 rpm
46 45 41 43

AI R REV FWD 1ST 3RD 2ND


BREATHER CLUTCH CLUTCH CLUTCH CLUTCH CLUTCH
SCREEN

OIL SUMP

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
OPERATOR COMPARTMENT
PRESSURE TEMPERATURE
GAUGE GAUGE

TORQUE
37 CONVERTER 32 AA

X158715en / B / 18 Jan 2016


71

TM Transmission TE 17 FF.01en
HOSE COOLER HOSE
1 DANA TE 17 FULL FLOW

LUBRICATION
Forward 1st speed

TORQUE CONVERTER
SAFETY VALVE
BY-PASS VALVE
9 bar
5 bar DIFFERENTIALPRESSURE 37

PRESSUREREGULATOR
VALVE 28.5-31.5 bar 41

1ST/3RD 73 2ND
2ND

FWD/REV TEMPERATURE
1ST/3RD
SENSOR

Lubrication
FILTER FILTER BY-PASS
VALVE
Low pressure FWD/N/REV
1ST/3RD
High pressure
42
Drain

66 67

PUMP 46 45 41 43
MIN 92,1 L/min @2420 rpm CONTROL VALVE
MAX 137,1 L/min @2916 rpm
46 45 41 43

AIR REV FWD 1ST 3RD 2ND


BREATHER CLUTCH CLUTCH CLUTCH CLUTCH CLUTCH
SCREEN

OIL SUMP

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


13/94
TECHNICAL MANUAL
14/94
OPERATOR COMPARTMENT
PRESSURE TEMPERATURE
GAUGE GAUGE

TORQUE
37 CONVERTER 32 AA

71

X158715en / B / 18 Jan 2016


TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
HOSE COOLER HOSE

LUBRICATION
Forward 2nd speed

TORQUE CONVERTER
SAFETY VALVE
BY-PASS VALVE
9 bar
5 bar DIFFERENTIALPRESSURE 37

PRESSUREREGULATOR
VALVE 28.5-31.5 bar 41

1ST/3RD 1ST/3RD 73 2ND

FWD/REV TEMPERATURE 2ND


SENSOR

Lubrication

Low pressure
FILTER FILTER BY-PASS 1ST/3RD
VALVE
High pressure FWD/N/REV

Drain
42

66 67

PUMP 46 45 41 43
MIN 92,1 L/min @2420 rpm CONTROL VALVE
MAX 137,1 L/min @2916 rpm
46 45 41 43

AIR REV FWD 1ST 3RD 2ND


BREATHER CLUTCH CLUTCH CLUTCH CLUTCH CLUTCH
SCREEN

OIL SUMP

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
OPERATOR COMPARTMENT
PRESSURE TEMPERATURE
GAUGE GAUGE

TORQUE
37 CONVERTER 32 AA

X158715en / B / 18 Jan 2016


71

TM Transmission TE 17 FF.01en
HOSE HOSE
1 DANA TE 17 FULL FLOW

COOLER
Forward 3rd speed

LUBRICATION

TORQUE CONVERTER
SAFETY VALVE
BY-PASS VALVE
9 bar
5 bar DIFFERENTIALPRESSURE 37

PRESSUREREGULATOR
VALVE 28.5-31.5 bar 41

1ST/3RD 73 2ND
2ND

FWD/REV TEMPERATURE
1ST/3RD
SENSOR

FILTER FILTER BY-PASS 1ST/3RD


VALVE
FWD/N/REV
Lubrication

Low pressure 42

High pressure

Drain 66 67

PUMP 46 45 41 43
MIN 92,1 L/min @2420 rpm CONTROL VALVE
MAX 137,1 L/min @2916 rpm
46 45 41 43

AIR REV FWD 1ST 3RD 2ND


BREATHER CLUTCH CLUTCH CLUTCH CLUTCH CLUTCH
SCREEN

OIL SUMP

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


15/94
TECHNICAL MANUAL
16/94
OPERATOR COMPARTMENT
PRESSURE TEMPERATURE
GAUGE GAUGE

X158715en / B / 18 Jan 2016


TORQUE
TECHNICAL MANUAL

37 CONVERTER 32 AA

TM Transmission TE 17 FF.01en
71

HOSE COOLER HOSE


Reverse 1st speed

LUBRICATION

TORQUE CONVERTER
SAFETY VALVE
BY-PASS VALVE
9 bar
5 bar DIFFERENTIALPRESSURE 37

PRESSUREREGULATOR
VALVE 28.5-31.5 bar
41

1ST/3RD 73 2 ND
2ND

FWD/REV TEMPERATURE
1ST/3RD
SENSOR

FWD/N/REV

FILTER FILTER BY-PASS


VALVE
1ST/3RD

42

66 67

PUMP 46 45 41 43
MIN 92,1 L/min @2420 rpm CONTROL VALVE
MAX 137,1 L/min @2916 rpm
46 45 41 43

AIR RE V FWD 1ST 3RD 2ND


BREATHER CLUTCH CLUTCH CLUTCH CLUTCH CLUTCH
SCREEN

OIL SUMP

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
OPERATOR COMPARTMENT
PRESSURE TEMPERATURE
GAUGE GAUGE

TORQUE

X158715en / B / 18 Jan 2016


37 CONVERTER 32 AA

TM Transmission TE 17 FF.01en
71
1 DANA TE 17 FULL FLOW

HOSE COOLER HOSE


Reverse 2nd speed

LUBRICATION

TORQUE CONVERTER
SAFETY VALVE
BY-PASS VALVE
9 bar
5 bar DIFFERENTIALPRESSURE 37

PRESSUREREGULATOR
VALVE 28.5-31.5 bar
41

1ST/3RD 1ST/3RD 73 2ND

FWD/REV TEMPERATURE 2ND


SENSOR

FWD/N/REV

FILTER FILTER BY-PASS 1ST/3RD


VALVE

42

66 67

PUMP 46 45 41 43
MIN 92,1 L/min @2420 rpm CONTROL VALVE
MAX 137,1 L/min @2916 rpm
46 45 41 43

AIR REV FWD 1ST 3RD 2ND


BREATHER CLUTCH CLUTCH CLUTCH CLUTCH CLUTCH
SCREEN

OIL SUMP

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


17/94
TECHNICAL MANUAL
18/94
OPERATOR COMPARTMENT
PRESSURE TEMPERATURE
GAUGE GAUGE

TORQUE
37 CONVERTER 32 AA

X158715en / B / 18 Jan 2016


TECHNICAL MANUAL

71

TM Transmission TE 17 FF.01en
HOSE COOLER HOSE
Reverse 3rd speed

LUBRICATION

TORQUE CONVERTER
SAFETY VALVE
BY-PASS VALVE
9 bar
5 bar DIFFERENTIAL PRESSURE 37

PRESSURE REGULATOR 41
VALVE 28.5-31.5 bar

1ST/3RD 73 2ND
2ND

FWD/REV TEMPERATURE
1ST/3RD
SENSOR

FWD/N/REV

Lubruca tion FILTER FILTER BY-PASS 1ST/3RD


VALVE
Lo w pr essure

H igh pr essure 42

Dr ain
66 67

PUMP 46 45 41 43
MIN 92,1 L/min @ 2420 rpm CONTROL VALVE
MAX 137,1 L/min @ 2916 rpm
46 45 41 43

AI R REV FWD 1ST 3RD 2ND


BREATHER CLUTCH CLUTCH CLUTCH CLUTCH CLUTCH
SCREEN

OIL SUMP

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
1 DANA TE 17 FULL FLOW TECHNICAL MANUAL

1.3 Check ports


Rear side of transmission

1. Port 12B - From cooler 1


2. Port 31 - Pressure regulator 3
9
3. Port 41 - Pressure check port 1st clutch
4. Port 67 - Pressure check port 1st/3rd 4
5. Port 66 - Pressure check port FWD/REV 8
5
6. Port 42 - Pressure check port 2nd clutch
7. Sump temperature sensor 6 2
8. Temperature Check port for cooler (1/4-
18NPFT) 7

10

Figure 7. Rear side of transmission

Front side of transmission

1. Plug - Magnetic drain M22 x 1.5 UNI

Figure 8. Front side of transmission

Left side of transmission


4 2
1
1. Air breather
2. Engine speed sensor
3 5
3. Drum speed sensor
4. Port 34 - Lube pressure pump gear
5. Port 45 - FWD clutch pressure

Figure 9. Left side of transmission

19/94
X158715en / B / 18 Jan 2016 Copyright © (2016) Konecranes Lifttrucks. All rights reserved.
TM Transmission TE 17 FF.01en
TECHNICAL MANUAL 1 DANA TE 17 FULL FLOW

Right side of transmission


2 5 7 1 3
1. Port 11 - Pressure to cooler 1

2. Port 33 - Pressure from cooler


3. Port 34 - Lube pressure pump gear
4. Port 37 - Pressure safety valve
5. Port 43 - Pressure checkport 3rd clutch
6. Output speed sensor
7. Turbine speed sensor

6
4

Figure 10. Right side of transmission

Top side of transmission


6
1. Port 12A - Pressure from cooler
2. Port 35 - Pressure pump 4
3. Port 45 - Pressure check port FWD
4. Port 46 - Pressure check port REV 3
5. Filler hole
6. Lifting eye locations

2 5

Figure 11. Top side of transmission

Bottom side of transmission

1. Port 32 - Pressure to cooler

Figure 12. Bottom side of transmission

20/94
X158715en / B / 18 Jan 2016 Copyright © (2016) Konecranes Lifttrucks. All rights reserved.
TM Transmission TE 17 FF.01en
1 DANA TE 17 FULL FLOW TECHNICAL MANUAL

Right side of control valve


5 6
1. Port 31 - System pressure
2. Port 41 - 1st clutch pressure
3. Port 42 - 2nd clutch pressure
4
4. Port 43 - 3rd clutch pressure
5. Port 45 - FWD clutch pressure
6. Port 46 - REV clutch pressure
7. Port 66 - FWD/REV regulated pressure 2 1
8. Port 67 - 1st/3rd regulated pressure
8 3

Figure 13. Right side of control valve

1.4 Control valve

1.4.1 Disassembly

4 5 22

16 10 21
1ST

15 9 6
1/3

8 1
REG

14
F/R

12 11 2 20
2ND

23
7 3
13
4214725R
19 17 18

1. Make sure that the area around the valve is clean.


So that no dirt falls in the valve during the disassembly.
2. Unscrew the bolts (1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22,
23) few turns.
When all the bolts are loose, move the valve for a small distance.
3. Replace the bolts by aligning studs.
4. Remove the remaining bolts and valve from the transmission case.
21/94
X158715en / B / 18 Jan 2016 Copyright © (2016) Konecranes Lifttrucks. All rights reserved.
TM Transmission TE 17 FF.01en
TECHNICAL MANUAL 1 DANA TE 17 FULL FLOW

1.4.2 Assembly

26
33

1ST
24
34

1/3

REG
28 35
36

F/R
25 27 32

2ND
29 30 31

4214725R

1. Install the two aligning studs.


2. Install the new inner gasket.
3. Install the separator plate.
4. Install the new control valve outer gasket.
5. Use two aligning studs and install control valve assembly.
6. Install the bolts and tighten to specified torque.
7. Install the separator plate with a new gasket on each side.
8. Use a chain hoist to position valve assembly on transmission.
9. Install the control valve assembly bolts, lock washers, and capscrews.
Tighten to specified torque.
10. Install the bolts and tighten to specified torque.
11. Install the new stator support gasket.
12. Install the new seals on stator support and install the stator support.

1.5 Testing

1.5.1 Stall test


To identify the problems in transmission, converter or engine, carry out the following stall test:

1. Prevent forward or reverse movement of machine by applying service brake and blocking
the wheels.

22/94
X158715en / B / 18 Jan 2016 Copyright © (2016) Konecranes Lifttrucks. All rights reserved.
TM Transmission TE 17 FF.01en
1 DANA TE 17 FULL FLOW TECHNICAL MANUAL

2. Put the gear lever in forward (or reverse as applicable).


3. Select the highest speed.
With the engine running, slowly increase engine RPM to one-half throttle and hold until
transmission (converter outlet) oil temperature reaches the operating range 70°C.
4. Now check the maximum stall speed at full throttle in all gears. It should be within 50 RPM
and equal in all gears.
• If maximum stall speed measured is below specification, it indicates an engine or
converter problem.
• If maximum stall speed measured is above specification, it indicates slipping clutches.

RISK OF PROPERTY DAMAGE


Excessive temperature (120°C maximum) causes damage to clutches, fluid,
NOTICE converter, and seals.
Do not operate the converter at stall mode longer than 30 s, shift to neutral for 15 s
and then repeat the procedure until desired temperature is reached.

1.5.2 Transmission pressure checks


Transmission problems can be isolated using pressure tests. When stall test indicates slipping
clutches, then measure clutch package pressure to determine if slippage is due to low pressure
or clutch plate friction material failure. Also converter charging pressure and transmission
lubrication pressure can be measured.

1.5.3 Mechanical and electrical checks


Before checking the hydraulic system functions, carry out the following mechanical and
electrical checks.

1. Check the parking brake and inching pedal for correct adjustment.
2. Be sure that all lever linkage is properly connected and adjusted in each segment and at all
connecting points.
3. Check the wiring and electrical components.
4. Check all the components of air conditioning.

1.5.4 Hydraulic checks


Before checking the transmission clutch, converter, charging pump and hydraulic circuit for
pressure and rate of flow, it is important to make the following transmission oil check.

1. Check oil level in the transmission.


2. All clutches, converter, and its fluid circuit lines must be fully filled always.

1.5.5 Speed sensor - static standalone test


To sense the currents, a series of resistor for example 200 ohm must be used. This resistor is
integrated in the controller, but when the sensor is to be used, it must be connected externally.

23/94
X158715en / B / 18 Jan 2016 Copyright © (2016) Konecranes Lifttrucks. All rights reserved.
TM Transmission TE 17 FF.01en
TECHNICAL MANUAL 1 DANA TE 17 FULL FLOW

1. Connect the sensor to an external power


source and measure the DC voltage across +12V
the series resistor.

+
n
-
Sensor

200 Ohm 1 Watt V

2. Voltage reading should be either 1.2 V –1.6 V (from the 7 mA ± 1 mA current level) or 2.6
V–3.0 V (for the 14 mA ± 1 mA current level).
3. If the gear teeth is moved slowly, notice the distinct toggling between the levels.

24/94
X158715en / B / 18 Jan 2016 Copyright © (2016) Konecranes Lifttrucks. All rights reserved.
TM Transmission TE 17 FF.01en
1 DANA TE 17 FULL FLOW TECHNICAL MANUAL

1.6 Troubleshooting

1.6.1 Troubleshooting

Fault Probable cause Action

Low clutch package Low oil level Fill to proper oil level
pressure
Clutch package pressure regulating Clean valve spool and
valve stuck open housing

Faulty charging pump Replace pump

Broken or worn clutch shaft or Replace seals


piston seals

Clutch piston bleed valve open Clean bleed valve thoroughly

Low charging pump Low oil level Fill to proper oil level
output flow
Suction screen that is clogged Clean suction screen

Defective charging pump Replace charging pump

Overheating Worn oil seals Remove, disassemble, and


rebuild converter assembly

Worn charging pump Replace charging pump

Low oil level Fill to proper oil level

Dirty oil cooler Clean cooler

Restriction in oil cooler lines Change cooler lines

Noisy converter Worn charging pump Replace charging pump

Worn or damaged bearings A complete disassembly is


necessary to find faulty
bearing

Lack of power Low engine RPM at converter stall Tune engine, check governor

Refer 'Overheating' and do same Do corrections as explained


checks in 'Overheating'

1.6.2 Troubleshooting for error 42.05


42.05 = Actual (measured) transmission ratio (turbine rpm or output rpm) is too high. Control
unit goes in transmission shutdown mode. Total neutral solenoid is deactivated and as a result
no pressure is going into the valve. As soon as the error is active, it is useless to measure
behind the total neutral spool.

Possible reasons for error:

• Faulty turbine or output speed sensor


• Engine driven slippage of clutch
• Wrong apt-file in control unit
• Wrong clutch is engaged

1. Find out on which gear the error code flags: F - R - 1 - 2 - 3 - 4


1.1 If Error 42.05 appears on all gears, check the speed sensor signal on the turbine
speed sensor and the output speed sensor. Also check the pressure on port 31 on the
control valve.
25/94
X158715en / B / 18 Jan 2016 Copyright © (2016) Konecranes Lifttrucks. All rights reserved.
TM Transmission TE 17 FF.01en
TECHNICAL MANUAL 1 DANA TE 17 FULL FLOW

1.2 If output sensor signal is not OK, change the speed sensor.
1.3 If output sensor signal is OK, measure the regulated pressure on Port 31.
1.4 If the pressure is OK proceed with next step.
2. Run a stall test to check if there is a slipping clutch.
To enter heat mode follow steps below:
2.1 Press the S button for at least 15 seconds when APC is powered up.
2.2 Change the menu by pressing the M button and stop at heat or stall and confirm with
the S button.
2.3 In heat mode the actual transmission oil temperature is displayed and in stall mode the
engine RPM is displayed.
2.4 In heat mode Fwd, Rev, 3rd and 4th clutch can be stalled.
2.5 In stall mode all clutch can be stalled. Use the S button to select the range clutch.
2.6 Measure stall rpm for all gears.

Fwd: 1st 2nd 3rd 4th gear____


gear________ gear_________ gear_________

Rev: 1st 2nd 3rd 4th gear____


gear________ gear_________ gear_________

3. Run a transmission calibration.


If calibration stops, note the failure code on the APC display.

C1 = Fwd_______ C2 = Rev_______

C3 = 1st________ C4 = 2nd_______ C5 = 3rd______ C6 = 4th______

4. Measure and note the clutch package pressure on the failing clutch. (Minimum 22.5 bar -
Maximum 24.5 bar)

Check Port 41 – 1st clutch package pressure ___________bar

Check Port 42 – 2nd clutch package pressure ___________bar

Check Port 43 – 3rd clutch package pressure ___________bar

Check Port 44 – 4th clutch package pressure ___________bar

Check Port 45 – Fwd clutch package pressure ___________bar

Check Port 46 – Rev clutch package pressure ___________bar

4.1 If the pressure is low in any gear, try to swop the proportional valve and see if the
failure moves with the solenoid.
4.2 If the valve is full of contamination behind the cover. Contact Konecranes dealer for
further instructions..
4.3 If the valve is free from contamination proceed with step 5.
5. If the pressure is still low in any of the gear then measure and note the pressures on the
port.

Check Port 67 – 1st/3rd ___________bar

Check Port 68 – 2nd/4th ___________bar

Check Port 66 – Fwd/Rev ___________bar

26/94
X158715en / B / 18 Jan 2016 Copyright © (2016) Konecranes Lifttrucks. All rights reserved.
TM Transmission TE 17 FF.01en
1 DANA TE 17 FULL FLOW TECHNICAL MANUAL

5.1 If the pressure is low change the solenoid.


5.2 If the pressure is OK the problem can be related to a sticking spool in the control valve
or an internal leakage in the transmission.

1.7 Error codes list


To check the troubleshooting, refer Error codes (page 32)

27/94
X158715en / B / 18 Jan 2016 Copyright © (2016) Konecranes Lifttrucks. All rights reserved.
TM Transmission TE 17 FF.01en
TECHNICAL MANUAL 1 DANA TE 17 FULL FLOW

SPN FMI DANA fault code SPN FMI DANA fault code
(DEC) (DEC) (DEC) (DEC)

520192 31 90.xx - 99.xx 520215 15 57.05

520208 4 50.00 520216 4 58.00

520208 3 50.01 520216 3 58.01

520208 17 50.04 520216 17 58.04

520208 15 50.05 520216 15 58.05

520209 4 51.00 520218 6 60.00

520209 3 51.01 520219 6 61.00

520209 17 51.04 520219 5 61.01

520209 15 51.05 520219 10 61.03

520210 4 52.00 520219 1 61.04

520210 3 52.01 520219 0 61.05

520210 17 52.04 520220 6 62.00

520210 15 52.05 520220 5 62.01

520211 4 53.00 520220 10 62.03

520211 3 53.01 520220 1 62.04

520211 17 53.04 520220 0 62.05

520211 15 53.05 520221 6 63.00

520212 4 54.00 520221 5 63.01

520212 3 54.01 520221 10 63.03

520213 4 55.00 520221 1 63.04

520213 3 55.01 520221 0 63.05

520213 17 55.04 520224 4 70.00

520213 15 55.05 520224 3 70.01

520214 4 56.00 520224 6 70.02

520214 3 56.01 520224 8 70.03

520214 17 56.04 520224 5 70.09

520214 15 56.05 520225 4 71.00

520215 4 57.00 520225 3 71.01

520215 3 57.01 520225 6 71.02

520215 17 57.04 520225 8 71.03

28/94
X158715en / B / 18 Jan 2016 Copyright © (2016) Konecranes Lifttrucks. All rights reserved.
TM Transmission TE 17 FF.01en
1 DANA TE 17 FULL FLOW TECHNICAL MANUAL

SPN FMI DANA fault code SPN FMI DANA fault code
(DEC) (DEC) (DEC) (DEC)

520225 5 71.09 520234 4 83.01

520226 4 72.00 520239 31 77.02

520226 3 72.01 520246 15 46.05

520226 6 72.02 520257 31 40.08

520226 8 72.03 520264 2 45.06

520226 5 72.09 520286 2 40.06

520227 4 73.00 520287 2 41.06

520227 3 73.01 520291 4 43.03

520227 6 73.02 520291 16 43.07

520227 8 73.03 520291 0 43.08

520227 5 73.09 520293 1 20.60

520228 4 74.00 520293 0 20.61

520228 3 74.01 520297 1 21.00

520229 4 75.00 520297 0 21.01

520229 3 75.01 520298 1 22.00

520230 4 76.00 520298 0 22.01

520230 3 76.01 520299 1 23.00

520230 6 76.02 520299 0 23.01

520230 8 76.03 520300 1 24.00

520230 5 76.09 520300 0 24.01

520231 4 80.00 520314 1 62.06

520231 3 80.01 520315 16 47.01

520231 5 80.09 520320 1 42.04

520232 4 81.00 520320 0 42.05

520232 3 81.01 520336 1 30.04

520232 5 81.09 520336 0 30.05

520233 4 82.00 520339 1 31.00

520233 3 82.01 520339 0 31.01

520233 5 82.09 520347 31 95.71

520234 3 83.00 520349 12 00.50

29/94
X158715en / B / 18 Jan 2016 Copyright © (2016) Konecranes Lifttrucks. All rights reserved.
TM Transmission TE 17 FF.01en
TECHNICAL MANUAL 1 DANA TE 17 FULL FLOW

SPN FMI DANA fault code SPN FMI DANA fault code
(DEC) (DEC) (DEC) (DEC)

520349 12 00.51 520432 2 90.03

520349 12 00.52 520432 3 90.04

520349 12 00.53 520432 4 90.05

520352 19 90.90 520432 5 90.06

520371 0 38.00 520432 6 90.07

520371 1 38.01 520432 7 90.08

520372 0 39.00 520432 8 90.09

520372 1 39.01 520432 9 90.11

520379 31 34.00 520432 11 90.12

520380 1 34.01 520432 12 90.13

520381 0 34.02 520432 13 90.14

520382 1 34.03 520432 14 90.15

520382 0 34.04 520432 15 90.16

520390 9 44.10 520432 16 90.17

520394 31 99.95 520432 17 90.18

520416 13 E5.01 520432 18 90.19

520417 15 E0.01 520433 1 91.01

520418 15 E1.01 520433 2 91.02

520419 15 E2.01 520433 3 91.03

520420 14 E3.00 520433 6 91.10

520420 15 E3.01 520433 7 91.11

520420 16 E3.02 520433 8 91.12

520421 17 E4.00 520434 0 92.00

520421 15 E4.01 520434 1 92.01

520422 31 E6.00 520434 2 92.02

520423 15 E7.01 520434 3 92.03

520424 15 E8.01 520434 4 92.04

520425 15 E9.01 520434 6 92.06

520432 90.01 520434 7 92.07

520432 1 90.02 520434 8 92.08

30/94
X158715en / B / 18 Jan 2016 Copyright © (2016) Konecranes Lifttrucks. All rights reserved.
TM Transmission TE 17 FF.01en
1 DANA TE 17 FULL FLOW TECHNICAL MANUAL

SPN FMI DANA fault code SPN FMI DANA fault code
(DEC) (DEC) (DEC) (DEC)

520434 9 92.09 520437 0 95.00

520434 10 92.1 520437 20 95.70

520434 11 92.11 520437 22 95.72

520434 12 92.12 520437 23 95.73

520434 13 92.13 520438 0 99.90

520434 14 92.14 520438 1 99.91

520434 15 92.15 520438 2 99.92

520434 16 92.16 520438 3 99.93

520434 17 92.17 520438 9 99.99

520434 18 92.18 520439 10 91.50

520434 19 92.19 520439 11 91.51

520434 20 92.2 520439 12 91.52

520434 21 92.21 520439 13 91.53

520434 30 92.30 520439 14 91.54

520435 0 93.00 520439 15 91.55

520435 1 93.01 520439 17 91.57

520435 2 93.02 520439 18 91.58

520435 3 93.03 520439 19 91.59

520435 4 93.04 520439 20 91.60

520435 5 93.05 520439 21 91.61

520435 9 93.09 520439 30 91.70

520435 10 93.10 520440 1 92.50

520435 11 93.11 520440 2 92.51

520436 0 94.00 520440 3 92.52

520436 1 94.01 xx.49

520436 2 94.02

520436 3 94.03

520436 4 94.04

520436 5 94.05

520436 9 94.09

31/94
X158715en / B / 18 Jan 2016 Copyright © (2016) Konecranes Lifttrucks. All rights reserved.
TM Transmission TE 17 FF.01en
1.8

32/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
Error codes

00.50 520349 12 There is a problem related to Controller reverts to a Hardware related fault - Contact Spicer Off-Highway
the internal RAM (in CPU). "shut down" mode and will related to in the internal RAM. and inform the fault code
force neutral 0 and the time that is was
active.

00.51 520349 12 There is a problem related to Controller reverts to a Hardware related fault - Contact Spicer Off-Highway
the system RAM (in CPU). "shut down" mode and will related to in the system RAM. and inform the fault code
force neutral 0 and the time that is was
active.

00.52 520349 12 There is a problem related to Controller reverts to a Hardware related fault - Contact Spicer Off-Highway
the external RAM. "shut down" mode and will related to in the external and inform the fault code
force neutral 0 RAM. and the time that is was
active.

00.53 520349 12 There is a problem related to Controller reverts to a Hardware related fault - Contact Spicer Off-Highway
the Flash program memory. "shut down" mode and will related to in the flash program and inform the fault code
force neutral 0 memory. and the time that is was
active.

20.60 520293 1 Pressure feed-back line is Controller reverts to a The analog input ANI0 is in Check the wiring between
indicating there is no system "shut down" mode and will the 1500 - 4000 ohm range, the controller and the
pressure present, allthough force neutral 0 while it should be in the 500 - pressure feedback sensor.
pressure should be there 1500 ohm range Check the pressure
feedback sensor (engine
running / stopped).

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)

TM Transmission TE 17 FF.01en
20.61 520293 0 Pressure feed-back line is Controller reverts to a The analog input ANI0 is in Check the wiring between
indicating there is system "shut down" mode and will the 500 - 1500 ohm range, the controller and the
1 DANA TE 17 FULL FLOW

pressure present, allthough force neutral 0 while it should be in the 1500 pressure feedback sensor.
pressure should NOT be - 4000 ohm range Check the pressure
there feedback sensor (engine
running / stopped).

21.00 520297 1 Pressure on sensor 1 too low Controller reverts to a Supply pressure to Check supply pressure to
for command. "shut down" mode and will transmission too low. the transmission. Log
force neutral 0 Proportional solenoid stuck. pressure when problem
occurs.

21.01 520297 0 Pressure on sensor 1 too Controller reverts to a Supply pressure to Check supply pressure to
high for command. "shut down" mode and will transmission too high. the transmission. Log
force neutral 0 Proportional solenoid stuck. pressure when problem
occurs.

22.00 520298 1 Pressure on sensor 2 too low Controller reverts to a Supply pressure to Check supply pressure to
for command. "shut down" mode and will transmission too low. the transmission. Log
force neutral 0 Proportional solenoid stuck. pressure when problem
occurs.

22.01 520298 0 Pressure on sensor 2 too Controller reverts to a Supply pressure to Check supply pressure to
high for command. "shut down" mode and will transmission too high. the transmission. Log
force neutral 0 Proportional solenoid stuck. pressure when problem
occurs.

23.00 520299 1 Pressure on sensor 3 too low Controller reverts to a Supply pressure to Check supply pressure to
for command. "shut down" mode and will transmission too low. the transmission. Log
force neutral 0 Proportional solenoid stuck. pressure when problem
occurs.

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


33/94
TECHNICAL MANUAL
34/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
23.01 520299 0 Pressure on sensor 3 too Controller reverts to a Supply pressure to Check supply pressure to
high for command. "shut down" mode and will transmission too high. the transmission. Log
force neutral 0 Proportional solenoid stuck. pressure when problem
occurs.

24.00 520300 1 Pressure on sensor 4 too low Controller reverts to a Supply pressure to Check supply pressure to
for command. "shut down" mode and will transmission too low. the transmission. Log
force neutral 0 Proportional solenoid stuck. pressure when problem
occurs.

24.01 520300 0 Pressure on sensor 4 too Controller reverts to a Supply pressure to Check supply pressure to
high for command. "shut down" mode and will transmission too high. the transmission. Log
force neutral 0 Proportional solenoid stuck. pressure when problem
occurs.

30.04 520336 1 Power supply out of range -> Controller will save all "Power supply to the Check power supply cables
below minimum logged information to controller too low:APC200 to the controller. Check
flash, will powerdown, and 12V supply version: < 9 alternator, check the
force all outputs off VAPC200 24V supply connection cables between
version: < 16V" the battery and the
alternator, check the battery.

30.05 520336 0 Power supply out of range -> The controller will have "Power supply to the Check power supply, check
above maximum reduced proportional controller too high:APC200 if a jump start setup is still
control accuracy due to 12V supply version: > 18 connected.
reduced PWM duty cycle VAPC200 24V supply
version: > 32 V"

31.00 520339 1 Voltage supply for the The controller will have Voltage supply for the Check power supply. Check
sensors : Vsense (8V) is out reduced sensor signals sensors : Vsense (8V) is the controller.
of range -> below minimum below 7,2 V

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)

TM Transmission TE 17 FF.01en
31.01 520339 0 Voltage supply for the The controller will have Voltage supply for the Check power supply. Check
sensors : Vsense (8V) is out reduced sensor signals sensors : Vsense (8V) is the controller.
1 DANA TE 17 FULL FLOW

of range -> above maximum above 8,8 V

34.00 520379 31 Speed sensor related fault The controller reverts to a One or more speed channel Check the wiring between
"limp home" mode. failures the controller and the speed
sensors. Check the speed
sensors,

34.01 520380 1 Measured turbine speed is Controller reverts to a "Speed sensor failure,Supply Check the wiring between
too low during initialisation "shut down" mode and will pressure to transmission too the controller and the speed
force neutral 0 low" sensors. Check the speed
sensors, Check the speed
sensor positions. Check
supply pressure to the
transmission

34.02 520381 0 Measured drum speed is too Controller reverts to a "Speed sensor failure,Too Check the wiring between
high during initialisation "shut down" mode and will much drag because of thick the controller and the speed
force neutral 0 oil, Sticking or burnt clutch" sensors. Check the speed
sensors, Check the speed
sensor positions.

34.03 520382 1 Internal transmission speeds Controller reverts to a "Speed sensor failure, RSP Check the wiring between
are indicating there is no "shut down" mode and will drive solenoid failure. Supply the controller and the speed
system pressure present, force neutral 0 pressure to transmission too sensors. Check the speed
allthough pressure should be low" sensors, Check the speed
there sensor positions.Check
supply pressure to the
transmission, Check the
RSP drive solenoid.

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


35/94
TECHNICAL MANUAL
36/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
34.04 520382 0 Internal transmission speeds Controller reverts to a "Speed sensor failure, RSP Check the wiring between
are indicating there is system "shut down" mode and will drive solenoid failure.Too the controller and the speed
pressure present, allthough force neutral 0 much drag because of thick sensors. Check the speed
pressure should NOT be oil, Sticking or burnt clutch " sensors, Check the speed
there sensor positions. Check the
RSP drive solenoid.

38.00 520371 0 disengaged 4WD/2WD Controller will flag the fault The mechanical actuator is Check if digital output has its
selector is stuck engaged, or stuck expected value and if the
feedback line is faulty mechanical actuator has
made the switch. Also check
if the digital feedback is
switched and still connected
to the controller.

38.01 520371 1 engaged 4WD/2WD selector Controller will flag the fault The mechanical actuator is Check if digital output has its
is stuck disengaged, or stuck expected value and if the
feedback line is faulty mechanical actuator has
made the switch. Also check
if the digital feedback is
switched and still connected
to the controller.

39.00 520372 0 disengaged Low/High Controller will flag the fault The mechanical actuator is Check if digital output has its
selector is stuck engaged, or stuck expected value and if the
the feedback line is faulty mechanical actuator has
made the switch. Also check
if the digital feedback is
switched and still connected
to the controller.

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)

TM Transmission TE 17 FF.01en
39.01 520372 1 engaged Low/High selector is Controller will flag the fault The mechanical actuator is Check if digital output has its
stuck disengaged, or the stuck expected value and if the
1 DANA TE 17 FULL FLOW

feedback line is faulty mechanical actuator has


made the switch. Also check
if the digital feedback is
switched and still connected
to the controller.

40.06 520286 2 Invalid shift lever direction The controller will force The controller receives from Check the wiring between
detected neutral. the shiftlever a request to the controller and the
engage forward and reverse shiftlever concerning the
at the same time. forward and the reverse
signal.

40.08 520257 31 Seat orientation input was The controller will force Seat orientation input was Check the seat orientation
changed while the parking neutral. changed while the parking switch or train the driver to
brake was not active, or/and brake was not active, or/and change the seat orientation
the shiftlever was not in the shiftlever was not in according to the correct
neutral, or/and the machine neutral, or/and the machine procedure.
was not at standstill. was not at standstill

41.06 520287 2 Invalid shift lever position The controller will not The controller receives from Check the wiring between
detected allow range shifting, the shiftlever an unknown the controller and the
however driving is still range shift pattern. shiftlever concerning the
possible. range signals.

42.04 520320 1 The actual transmission ratio Controller will flag the fault The transmission ratio Check the transmission, in
is too low. - this fault is indicating that measured by the controller is order to understand if and
one or more clutches are more than 5% below the which clutch is slipping.
slipping. The controller will value of what is should be. Check the transmission ratio
revert to shut down mode settings of the controller.

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


37/94
TECHNICAL MANUAL
38/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
42.05 520320 0 The actual transmission ratio Controller will flag the fault The transmission ratio Check the transmission, in
is too high. - this fault is indicating that measured by the controller is order to understand if and
one or more clutches are more than 5% above the which clutch is slipping.
slipping. The controller will value of what is should be. Check the transmission ratio
revert to shut down mode settings of the controller.

43.03 520291 4 The transmission converter Controller will flag the The converter out Check the wiring between
out temperature sensor is out fault. temperature sensor is not the controller and the
of range. connected or shorted. converter out temperature
sensor. Check the converter
out temperature sensor.

43.07 520291 16 The transmission converter Controller will flag the fault The controller measured a Check the converter out
out temperature sensor > - in order to indicate the converter out temperature temperature and the
100° C. driver of the warning level. between 100° C and the converter out temperature
allowed limit. sensor.

43.08 520291 0 The transmission converter The controller is protecting The controller measured a Check the converter out
out temperature sensor > the transmission and does converter out temperature temperature and the
125° C. not allow that the above the allowed limit. converter out temperature
converter out temperature sensor.
exceeds its limit. The
controller will force the
transmission to neutral,
and if engine is controlled,
the engine will be limited
50 % of its maximum
speed.

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)

TM Transmission TE 17 FF.01en
44.10 520390 9 No EEC2 message (throttle The controller will flag the No EEC2 message on the Check engine controller and
position from the engine fault and the TSC1 CAN bus when expected. CAN connection to the
1 DANA TE 17 FULL FLOW

controller) on the CAN bus message will send the idle APC200
when expected. possition to the engine
controller.

45.06 520264 2 Invalid pattern for the reduced The controller will limit the Invalid pattern for the reduced Check the redundant
vehicle speed redundant vehicle speed to the vehicle speed redundant reduced vehicle speed
digital inputs (2 inputs used). reduced speed. digital inputs (2 inputs used) switches and the wiring
connected from these
switches to the APC200.

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


39/94
TECHNICAL MANUAL
40/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
46.05 520246 15 The transmission has The controller will open or The transmission has Release the inching pedal
exceeded the maximum close the inching clutch exceeded the maximum and cycle the shiftlever via
torque during inching. depending of the GDE torque during inching. neutral back in the selected
parameter selection. direction.

47.01 520315 16 Transmission limit exceeded Controller will flag the fault The turbine speed is above Release throttle pedal, slow
the maximum allowed down the vehicle

50.00 520208 4 Analog input 0 (wire A11) "Depending on the The analog input ANI0 is Check the wiring between
related fault : analog input is function that is assigned to shorted to ground, or the controller and the device
shorted to ground. this pin:- temperature measured input value is connected to this analog
sensor: controller will use below the minimum value input. Check this device
the lowest clipped value in (corresponding with 0 %). connected. Check if the
its settings (which results calibration is done correctly -
in bad temperature recalibration of this analog
compensation- pressure input.
feedback: the controller
will revert to limp home
mode- pressure sensor:
the controller will revert to
shut down mode- other:
the controller will use the
lowest clipped value"

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)

TM Transmission TE 17 FF.01en
50.01 520208 3 Analog input 0 (wire A11) "Depending on the The analog input ANI0 is not Check the wiring between
related fault : analog input is function that is assigned to connected, or measured input the controller and the device
1 DANA TE 17 FULL FLOW

not connected. this pin:- temperature value is above the maximum connected to this analog
sensor: controller will use value (corresponding with input. Check this device
the highest clipped value 100 %). connected. Check if the
in its settings (which calibration is done correctly -
results in bad temperature recalibration of this analog
compensation- pressure input.
feedback: the controller
will revert to limp home
mode- pressure sensor:
the controller will revert to
shut down mode- other:
the controller will use the
lowest clipped value"

50.04 520208 17 Analog input 0 (wire A11) Controller will flag the The analog input ANI0 Check the wiring between
related fault : analog input fault, and will use the measured input value is the controller and the device
value is below the minimum lowest clipped value in its below the minimum value connected to this analog
value calibrated. settings. (corresponding with 0 %). input. Check this device
connected. Check if the
calibration is done correctly -
recalibration of this analog
input.

50.05 520208 15 Analog input 0 (wire A11) Controller will flag the The analog input ANI0 Check the wiring between
related fault : analog input fault, and will use the measured input value is the controller and the device
value is above the maximum highest clipped value in its above the maximum value connected to this analog
value calibrated. settings. (corresponding with 100 %). input. Check this device
connected. Check if the
calibration is done correctly -

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


41/94
recalibration of this analog
TECHNICAL MANUAL

input.
42/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
51.00 520209 4 Analog input 1 (wire A28) "Depending on the The analog input ANI1 is Check the wiring between
related fault : analog input is function that is assigned to shorted to ground, or the controller and the device
shorted to ground. this pin:- temperature measured input value is connected to this analog
sensor: controller will use below the minimum value input. Check this device
the lowest clipped value in (corresponding with 0 %). connected. Check if the
its settings (which results calibration is done correctly -
in bad temperature recalibration of this analog
compensation- pressure input.
feedback: the controller
will revert to limp home
mode- pressure sensor:
the controller will revert to
shut down mode- other:
the controller will use the
lowest clipped value"

51.01 520209 3 Analog input 1 (wire A28) "Depending on the The analog input ANI1 is not Check the wiring between
related fault : analog input is function that is assigned to connected, or measured input the controller and the device
not connected. this pin:- temperature value is above the maximum connected to this analog
sensor: controller will use value (corresponding with input. Check this device
the highest clipped value 100 %). connected. Check if the
in its settings (which calibration is done correctly -
results in bad temperature recalibration of this analog
compensation- pressure input.
feedback: the controller
will revert to limp home
mode- pressure sensor:
the controller will revert to
shut down mode- other:
the controller will use the
lowest clipped value"

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)

TM Transmission TE 17 FF.01en
51.04 520209 17 Analog input 1 (wire A28) Controller will flag the The analog input ANI1 Check the wiring between
related fault : analog input fault, and will use the measured input value is the controller and the device
1 DANA TE 17 FULL FLOW

value is below the minimum lowest clipped value in its below the minimum value connected to this analog
value calibrated. settings. (corresponding with 0 %). input. Check this device
connected. Check if the
calibration is done correctly -
recalibration of this analog
input.

51.05 520209 15 Analog input 1 (wire A28) Controller will flag the The analog input ANI1 Check the wiring between
related fault : analog input fault, and will use the measured input value is the controller and the device
value is above the maximum highest clipped value in its above the maximum value connected to this analog
value calibrated. settings. (corresponding with 100 %). input. Check this device
connected. Check if the
calibration is done correctly -
recalibration of this analog
input.

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


43/94
TECHNICAL MANUAL
44/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
52.00 520210 4 Analog input 2 (wire A29) "Depending on the The analog input ANI2 is Check the wiring between
related fault : analog input is function that is assigned to shorted to ground, or the controller and the device
shorted to ground. this pin:- temperature measured input value is connected to this analog
sensor: controller will use below the minimum value input. Check this device
the lowest clipped value in (corresponding with 0 %). connected. Check if the
its settings (which results calibration is done correctly -
in bad temperature recalibration of this analog
compensation- pressure input.
feedback: the controller
will revert to limp home
mode- pressure sensor:
the controller will revert to
shut down mode- other:
the controller will use the
lowest clipped value"

52.01 520210 3 Analog input 2 (wire A29) "Depending on the The analog input ANI2 is not Check the wiring between
related fault : analog input is function that is assigned to connected, or measured input the controller and the device
not connected. this pin:- temperature value is above the maximum connected to this analog
sensor: controller will use value (corresponding with input. Check this device
the highest clipped value 100 %). connected. Check if the
in its settings (which calibration is done correctly -
results in bad temperature recalibration of this analog
compensation- pressure input.
feedback: the controller
will revert to limp home
mode- pressure sensor:
the controller will revert to
shut down mode- other:
the controller will use the
lowest clipped value"

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)

TM Transmission TE 17 FF.01en
52.04 520210 17 Analog input 2 (wire A29) Controller will flag the The analog input ANI2 Check the wiring between
related fault : analog input fault, and will use the measured input value is the controller and the device
1 DANA TE 17 FULL FLOW

value is below the minimum lowest clipped value in its below the minimum value connected to this analog
value calibrated. settings. (corresponding with 0 %). input. Check this device
connected. Check if the
calibration is done correctly -
recalibration of this analog
input.

52.05 520210 15 Analog input 2 (wire A29) Controller will flag the The analog input ANI2 Check the wiring between
related fault : analog input fault, and will use the measured input value is the controller and the device
value is above the maximum highest clipped value in its above the maximum value connected to this analog
value calibrated. settings. (corresponding with 100 %). input. Check this device
connected. Check if the
calibration is done correctly -
recalibration of this analog
input.

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


45/94
TECHNICAL MANUAL
46/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
53.00 520211 4 Analog input 3 (wire B17) "Depending on the The analog input ANI3 is Check the wiring between
related fault : analog input is function that is assigned to shorted to ground, or the controller and the device
shorted to ground. this pin:- temperature measured input value is connected to this analog
sensor: controller will use below the minimum value input. Check this device
the lowest clipped value in (corresponding with 0 %). connected. Check if the
its settings (which results calibration is done correctly -
in bad temperature recalibration of this analog
compensation- pressure input.
feedback: the controller
will revert to limp home
mode- pressure sensor:
the controller will revert to
shut down mode- other:
the controller will use the
lowest clipped value"

53.01 520211 3 Analog input 3 (wire B17) "Depending on the The analog input ANI3 is not Check the wiring between
related fault : analog input is function that is assigned to connected, or measured input the controller and the device
not connected. this pin:- temperature value is above the maximum connected to this analog
sensor: controller will use value (corresponding with input. Check this device
the highest clipped value 100 %). connected. Check if the
in its settings (which calibration is done correctly -
results in bad temperature recalibration of this analog
compensation- pressure input.
feedback: the controller
will revert to limp home
mode- pressure sensor:
the controller will revert to
shut down mode- other:
the controller will use the
lowest clipped value"

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)

TM Transmission TE 17 FF.01en
53.04 520211 17 Analog input 3 (wire B17) Controller will flag the The analog input ANI3 Check the wiring between
related fault : analog input fault, and will use the measured input value is the controller and the device
1 DANA TE 17 FULL FLOW

value is below the minimum lowest clipped value in its below the minimum value connected to this analog
value calibrated. settings. (corresponding with 0 % - 100 input. Check this device
mV). connected. Check if the
calibration is done correctly -
recalibration of this analog
input.

53.05 520211 15 Analog input 3 (wire B17) Controller will flag the The analog input ANI3 Check the wiring between
related fault : analog input fault, and will use the measured input value is the controller and the device
value is above the maximum highest clipped value in its above the maximum value connected to this analog
value calibrated. settings. (corresponding with 100 % + input. Check this device
100 mV). connected. Check if the
calibration is done correctly -
recalibration of this analog
input.

54.00 520212 4 Analog input 4 (wire B02) Controller will revert to The reference power supply Check the refence power
related fault: analog input is shutdown. The controller (5 V ref.) for the analog inputs supply of the analog inputs
shorted to ground. uses the analog input ANI0, ANI2, ANI3, ANI5, ANI0, ANI2, ANI3, ANI5,
ANI4 to have a reference ANI6 and ANI8 is below 4,8 ANI6 and ANI8.
power supply for the V.
analog inputs ANI0, ANI2,
ANI3, ANI5, ANI6 and
ANI8

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


47/94
TECHNICAL MANUAL
48/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
54.01 520212 3 Analog input 4 (wire B02) Controller will revert to The reference power supply Check the refence power
related fault: analog input is shutdown. The controller (5 V ref.) for the analog inputs supply of the analog inputs
shorted to battery + uses the analog input ANI0, ANI2, ANI3, ANI5, ANI0, ANI2, ANI3, ANI5,
ANI4 to have a reference ANI6 & ANI8 is above 5,2 V. ANI6 and ANI8.
power supply for the
analog inputs ANI0, ANI2,
ANI3, ANI5, ANI6 and
ANI8

55.00 520213 4 Analog input 5 (wire B04) "Depending on the The analog input ANI5 is Check the wiring between
related fault : analog input is function that is assigned to shorted to ground, or the controller and the device
shorted to ground. this pin:- temperature measured input value is connected to this analog
sensor: controller will use below the minimum value input. Check this device
the lowest clipped value in (corresponding with 0 %). connected. Check if the
its settings (which results calibration is done correctly -
in bad temperature recalibration of this analog
compensation- pressure input.
feedback: the controller
will revert to limp home
mode- pressure sensor:
the controller will revert to
shut down mode- other:
the controller will use the
lowest clipped value"

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)

TM Transmission TE 17 FF.01en
55.01 520213 3 Analog input 5 (wire B04) "Depending on the The analog input ANI5 is not Check the wiring between
related fault : analog input is function that is assigned to connected, or measured input the controller and the device
1 DANA TE 17 FULL FLOW

not connected. this pin:- temperature value is above the maximum connected to this analog
sensor: controller will use value (corresponding with input. Check this device
the highest clipped value 100 %). connected. Check if the
in its settings (which calibration is done correctly -
results in bad temperature recalibration of this analog
compensation- pressure input.
feedback: the controller
will revert to limp home
mode- pressure sensor:
the controller will revert to
shut down mode- other:
the controller will use the
lowest clipped value"

55.04 520213 17 Analog input 5 (wire B04) Controller will flag the The analog input ANI5 Check the wiring between
related fault : analog input fault, and will use the measured input value is the controller and the device
value is below the minimum lowest clipped value in its below the minimum value connected to this analog
value calibrated. settings. (corresponding with 0 % - 100 input. Check this device
mV). connected. Check if the
calibration is done correctly -
recalibration of this analog
input.

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


49/94
TECHNICAL MANUAL
50/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
55.05 520213 15 Analog input 5 (wire B04) Controller will flag the The analog input ANI5 Check the wiring between
related fault : analog input fault, and will use the measured input value is the controller and the device
value is above the maximum highest clipped value in its above the maximum value connected to this analog
value calibrated. settings. (corresponding with 100 % + input. Check this device
100 mV). connected. Check if the
calibration is done correctly -
recalibration of this analog
input.

56.00 520214 4 Analog input 6 (wire B06) "Depending on the The analog input ANI6 is Check the wiring between
related fault : analog input is function that is assigned to shorted to ground, or the controller and the device
shorted to ground. this pin:- temperature measured input value is connected to this analog
sensor: controller will use below the minimum value input. Check this device
the lowest clipped value in (corresponding with 0 %). connected. Check if the
its settings (which results calibration is done correctly -
in bad temperature recalibration of this analog
compensation- pressure input.
feedback: the controller
will revert to limp home
mode- pressure sensor:
the controller will revert to
shut down mode- other:
the controller will use the
lowest clipped value"

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)

TM Transmission TE 17 FF.01en
56.01 520214 3 Analog input 6 (wire B06) "Depending on the The analog input ANI6 is not Check the wiring between
related fault : analog input is function that is assigned to connected, or measured input the controller and the device
1 DANA TE 17 FULL FLOW

not connected. this pin:- temperature value is above the maximum connected to this analog
sensor: controller will use value (corresponding with input. Check this device
the highest clipped value 100 %). connected. Check if the
in its settings (which calibration is done correctly -
results in bad temperature recalibration of this analog
compensation- pressure input.
feedback: the controller
will revert to limp home
mode- pressure sensor:
the controller will revert to
shut down mode- other:
the controller will use the
lowest clipped value"

56.04 520214 17 Analog input 6 (wire B06) Controller will flag the The analog input ANI6 Check the wiring between
related fault : analog input fault, and will use the measured input value is the controller and the device
value is below the minimum lowest clipped value in its below the minimum value connected to this analog
value calibrated. settings. (corresponding with 0 % - 100 input. Check this device
mV). connected. Check if the
calibration is done correctly -
recalibration of this analog
input.

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


51/94
TECHNICAL MANUAL
52/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
56.05 520214 15 Analog input 6 (wire B06) Controller will flag the The analog input ANI6 Check the wiring between
related fault : analog input fault, and will use the measured input value is the controller and the device
value is above the maximum highest clipped value in its above the maximum value connected to this analog
value calibrated. settings. (corresponding with 100 % + input. Check this device
100 mV). connected. Check if the
calibration is done correctly -
recalibration of this analog
input.

57.00 520215 4 Analog input 7 (wire A13) "Depending on the The analog input ANI7 is Check the wiring between
related fault : analog input is function that is assigned to shorted to ground, or the controller and the device
shorted to ground. this pin:- temperature measured input value is connected to this analog
sensor: controller will use below the minimum value input. Check this device
the lowest clipped value in (corresponding with 0 %). connected. Check if the
its settings (which results calibration is done correctly -
in bad temperature recalibration of this analog
compensation- pressure input.
feedback: the controller
will revert to limp home
mode- pressure sensor:
the controller will revert to
shut down mode- other:
the controller will use the
lowest clipped value"

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)

TM Transmission TE 17 FF.01en
57.01 520215 3 Analog input 7 (wire A13) "Depending on the The analog input ANI7 is not Check the wiring between
related fault : analog input is function that is assigned to connected, or measured input the controller and the device
1 DANA TE 17 FULL FLOW

not connected. this pin:- temperature value is above the maximum connected to this analog
sensor: controller will use value (corresponding with input. Check this device
the highest clipped value 100 %). connected. Check if the
in its settings (which calibration is done correctly -
results in bad temperature recalibration of this analog
compensation- pressure input.
feedback: the controller
will revert to limp home
mode- pressure sensor:
the controller will revert to
shut down mode- other:
the controller will use the
lowest clipped value"

57.04 520215 17 Analog input 7 (wire A13) Controller will flag the The analog input ANI7 Check the wiring between
related fault : analog input fault, and will use the measured input value is the controller and the device
value is below the minimum lowest clipped value in its below the minimum value connected to this analog
value calibrated. settings. (corresponding with 0 % - 100 input. Check this device
mV). connected. Check if the
calibration is done correctly -
recalibration of this analog
input.

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


53/94
TECHNICAL MANUAL
54/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
57.05 520215 15 Analog input 7 (wire A13) Controller will flag the The analog input ANI7 Check the wiring between
related fault : analog input fault, and will use the measured input value is the controller and the device
value is above the maximum highest clipped value in its above the maximum value connected to this analog
value calibrated. settings. (corresponding with 100 % + input. Check this device
100 mV). connected. Check if the
calibration is done correctly -
recalibration of this analog
input.

58.00 520216 4 Analog input 8 (wire A12) "Depending on the The analog input ANI8 is Check the wiring between
related fault : analog input is function that is assigned to shorted to ground, or the controller and the device
shorted to ground. this pin:- temperature measured input value is connected to this analog
sensor: controller will use below the minimum value input. Check this device
the lowest clipped value in (corresponding with 0 %). connected. Check if the
its settings (which results calibration is done correctly -
in bad temperature recalibration of this analog
compensation- pressure input.
feedback: the controller
will revert to limp home
mode- pressure sensor:
the controller will revert to
shut down mode- other:
the controller will use the
lowest clipped value"

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)

TM Transmission TE 17 FF.01en
58.01 520216 3 Analog input 8 (wire A12) "Depending on the The analog input ANI8 is not Check the wiring between
related fault : analog input is function that is assigned to connected, or measured input the controller and the device
1 DANA TE 17 FULL FLOW

not connected. this pin:- temperature value is above the maximum connected to this analog
sensor: controller will use value (corresponding with input. Check this device
the highest clipped value 100 %). connected. Check if the
in its settings (which calibration is done correctly -
results in bad temperature recalibration of this analog
compensation- pressure input.
feedback: the controller
will revert to limp home
mode- pressure sensor:
the controller will revert to
shut down mode- other:
the controller will use the
lowest clipped value"

58.04 520216 17 Analog input 8 (wire A12) Controller will flag the The analog input ANI8 Check the wiring between
related fault : analog input fault, and will use the measured input value is the controller and the device
value is below the minimum lowest clipped value in its below the minimum value connected to this analog
value calibrated. settings. (corresponding with 0 % - 100 input. Check this device
mV). connected. Check if the
calibration is done correctly -
recalibration of this analog
input.

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


55/94
TECHNICAL MANUAL
56/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
58.05 520216 15 Analog input 8 (wire A12) Controller will flag the The analog input ANI8 Check the wiring between
related fault : analog input fault, and will use the measured input value is the controller and the device
value is above the maximum highest clipped value in its above the maximum value connected to this analog
value calibrated. settings. (corresponding with 100 % + input. Check this device
100 mV). connected. Check if the
calibration is done correctly -
recalibration of this analog
input.

60.00 520218 6 Speed channel 0 (wire A22) When only 1 speed Speed channel SPC0 is Check the wiring between
related fault : speed channel channel has a failiure, and shorted to ground. the controller and the speed
is shorted to ground. which is not the engine sensor connected to speed
speed channel, the channel 0. Check the speed
controller will calculate sensor connected to speed
what the missing speed channel 0.
should be. If several
speed channels have a
failiure, of the engine
speed channel has a
failiure, the controller
reverts to a "limp home"
mode.

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)

TM Transmission TE 17 FF.01en
60.01 520218 5 Speed channel 0 (wire A22) When only 1 speed Speed channel SPC0 is not Check the wiring between
related fault : speed channel channel has a failiure, and connected. the controller and the speed
1 DANA TE 17 FULL FLOW

is not connected. which is not the engine sensor connected to speed


speed channel, the channel 0. Check the speed
controller will calculate sensor connected to speed
what the missing speed channel 0.
should be. If several
speed channels have a
failiure, of the engine
speed channel has a
failiure, the controller
reverts to a "limp home"
mode.

60.03 520218 10 Speed channel 0 (wire A22) The controlller flags the Speed channel SPC0 is not Check the wiring between
related fault : speed error code. connected, or measurement the controller and the speed
measurement out of range out of range sensor connected to speed
channel 0. Check the speed
sensor connected to speed
channel 0.

60.04 520218 1 Speed channel 0 (wire A22) This message is given as The transmission ratio Check the transmission, in
pulse count too low. additional information for measured by the controller is order to understand if and
transmission ratio faults. more than 5% below the which clutch is slipping.
value of what is should be. Check the transmission ratio
settings of the controller.

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


57/94
TECHNICAL MANUAL
58/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
60.05 520218 0 Speed channel 0 (wire A22) This message is given as The transmission ratio Check the transmission, in
pulse count too high additional information for measured by the controller is order to understand if and
transmission ratio faults. more than 5% above the which clutch is slipping.
value of what is should be. Check the transmission ratio
settings of the controller.

61.00 520219 6 Speed channel 1 (wire A24) When only 1 speed Speed channel SPC1 is Check the wiring between
related fault : speed channel channel has a failiure, and shorted to ground. the controller and the speed
is shorted to ground. which is not the engine sensor connected to speed
speed channel, the channel 1. Check the speed
controller will calculate sensor connected to speed
what the missing speed channel 1.
should be. If several
speed channels have a
failiure, or the engine
speed channel has a
failiure, the controller
reverts to a "limp home"
mode.

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)

TM Transmission TE 17 FF.01en
61.01 520219 5 Speed channel 1 (wire A24) When only 1 speed Speed channel SPC1 is not Check the wiring between
related fault : speed channel channel has a failiure, and connected. the controller and the speed
1 DANA TE 17 FULL FLOW

is not connected. which is not the engine sensor connected to speed


speed channel, the channel 1. Check the speed
controller will calculate sensor connected to speed
what the missing speed channel 1.
should be. If several
speed channels have a
failiure, or the engine
speed channel has a
failiure, the controller
reverts to a "limp home"
mode.

61.03 520219 10 Speed channel 1 (wire A24) The controlller flags the Speed channel SPC1 is not Check the wiring between
related fault : speed error code. connected, or measurement the controller and the speed
measurement out of range out of range sensor connected to speed
channel 1. Check the speed
sensor connected to speed
channel 1.

61.04 520219 1 Speed channel 1 (wire A24) This message is given as The transmission ratio Check the transmission, in
pulse count too low. additional information for measured by the controller is order to understand if and
transmission ratio faults. more than 5% below the which clutch is slipping.
value of what is should be. Check the transmission ratio
settings of the controller.

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


59/94
TECHNICAL MANUAL
60/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
61.05 520219 0 Speed channel 1 (wire A24) This message is given as The transmission ratio Check the transmission, in
pulse count too high. additional information for measured by the controller is order to understand if and
transmission ratio faults. more than 5% above the which clutch is slipping.
value of what is should be. Check the transmission ratio
settings of the controller.

62.00 520220 6 Speed channel 2 (wire A26) When only 1 speed Speed channel SPC2 is Check the wiring between
related fault : speed channel channel has a failiure, and shorted to ground. the controller and the speed
is shorted to ground. which is not the engine sensor connected to speed
speed channel, the channel 2. Check the speed
controller will calculate sensor connected to speed
what the missing speed channel 2.
should be. If several
speed channels have a
failiure, or the engine
speed channel has a
failiure, the controller
reverts to a "limp home"
mode.

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)

TM Transmission TE 17 FF.01en
62.01 520220 5 Speed channel 2 (wire A26) When only 1 speed Speed channel SPC2 is not Check the wiring between
related fault : speed channel channel has a failiure, and connected. the controller and the speed
1 DANA TE 17 FULL FLOW

is not connected. which is not the engine sensor connected to speed


speed channel, the channel 2. Check the speed
controller will calculate sensor connected to speed
what the missing speed channel 2.
should be. If several
speed channels have a
failiure, or the engine
speed channel has a
failiure, the controller
reverts to a "limp home"
mode.

62.03 520220 10 No engine speed information Controller reverts to a No EEC1 message on the Check engine controller and
available. "limp home" mode CAN bus for 200 ms. CAN connection to the
J1939_SIGNAL_ERROR or controller
J1939_SIGNAL_NOT_AVAIL
ABLE reported in EEC1.

62.04 520220 1 Speed channel 2 (wire A26) This message is given as The transmission ratio Check the transmission, in
pulse count too low. additional information for measured by the controller is order to understand if and
transmission ratio faults. more than 5% below the which clutch is slipping.
value of what is should be. Check the transmission ratio
settings of the controller.

62.05 520220 0 Speed channel 2 (wire A26) This message is given as The transmission ratio Check the transmission, in
pulse count too high additional information for measured by the controller is order to understand if and
transmission ratio faults. more than 5% above the which clutch is slipping.
value of what is should be. Check the transmission ratio
settings of the controller.

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


61/94
TECHNICAL MANUAL
62/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
62.06 520314 1 No engine speed detected Controller reverts to a Speed sensor damaged, bad Check the transmission and
while turbine speed is "limp home" mode alignment between sensor speed sensor. Check speed
measured and measuring gear. sensor position.

63.00 520221 6 "Speed channel 3 (wire B11* When only 1 speed Speed channel SPC3 is Check the wiring between
or A27*) related fault: speed channel has a failiure, and shorted to ground. the controller and the speed
channel is shorted to ground. which is not the engine sensor connected to speed
* please refer to hardware speed channel, the channel 3. Check the speed
technical leaflet of your APC controller will calculate sensor connected to speed
platform" what the missing speed channel 3.
should be. If several
speed channels have a
failiure, or the engine
speed channel has a
failiure, the controller
reverts to a "limp home"
mode.

63.01 520221 5 "Speed channel 3 (wire B11* When only 1 speed Speed channel SPC3 is not Check the wiring between
or A27*) related fault: speed channel has a failiure, and connected. the controller and the speed
channel is not connected. * which is not the engine sensor connected to speed
please refer to hardware speed channel, the channel 3. Check the speed
technical leaflet of your APC controller will calculate sensor connected to speed
platform" what the missing speed channel 3.
should be. If several
speed channels have a
failiure, or the engine
speed channel has a
failiure, the controller
reverts to a "limp home"
mode.

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)

TM Transmission TE 17 FF.01en
63.03 520221 10 "Speed channel 3 (wire B11* The controlller flags the Speed channel SPC3 is not Check the wiring between
or A27*) related fault: speed error code. connected, or measurement the controller and the speed
1 DANA TE 17 FULL FLOW

measurement out of range * out of range sensor connected to speed


please refer to hardware channel 3. Check the speed
technical leaflet of your APC sensor connected to speed
platform" channel 3.

63.04 520221 1 "Speed channel 3 (wire B11* This message is given as The transmission ratio Check the transmission, in
or A27*) pulse count too low* additional information for measured by the controller is order to understand if and
please refer to hardware transmission ratio faults. more than 5% below the which clutch is slipping.
technical leaflet of your APC value of what is should be. Check the transmission ratio
platform" settings of the controller.

63.05 520221 0 "Speed channel 3 (wire B11* This message is given as The transmission ratio Check the transmission, in
or A27*) pulse count too high* additional information for measured by the controller is order to understand if and
please refer to hardware transmission ratio faults. more than 5% above the which clutch is slipping.
technical leaflet of your APC value of what is should be. Check the transmission ratio
platform" settings of the controller.

70.00 520224 4 Analog output 0 (wires A02 & Controller reverts to a The output wires of the "Check the wiring between
A03) related fault : output "limp home" mode analog output 0 are shorted the controller and the
wires are shorted to each to each other, or the sense proportional valve 0 Check
other, or the sense line is line is shorted to battery +, or the proportional valve 0.
shorted to battery +, or the the plus line is shorted to (please refer to wiring
plus line is shorted to ground ground diagram to determine which
device is attached)"

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


63/94
TECHNICAL MANUAL
64/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
70.01 520224 3 Analog output 0 (wires A02 & Controller reverts to a An output wire of the analog "Check the wiring between
A03) related fault : the output "limp home" mode output 0 is not connected, or the controller and the output
plus line is shorted to battery its plus line is shorted to device #0 Check the output
+ battery +, or output device #0 device #0. (please refer to
is defect. wiring diagram to determine
which device is attached)"

70.02 520224 6 Analog output 0 (wires A02 & Controller reverts to a The current of the analog "Check the wiring between
A03) related fault : the output "shut down" mode and will output 0 is exceeding 1400 the controller and the output
current exceeds 1400 mA force neutral 0 mA. device #0 Check the output
or/and the output plus line is device #0. (please refer to
shorted to battery +. wiring diagram to determine
which device is attached)"

70.03 520224 8 Analog output 0 (wires A02 & Controller reverts to a The current of the analog "Check the wiring between
A03) related fault : the output "shut down" mode and will output 0 is out of range. the controller and the output
current is out of range, occurs force neutral 0 device #0 Check the output
when the load has the device #0. (please refer to
incorrect impedance wiring diagram to determine
which device is attached)"

70.09 520224 5 Analog output 0 (wires A02 & Controller reverts to a The wire of the analog output "Check the wiring between
A03) related fault : the output "limp home" mode 0 is not connected the controller and the output
is not connected device #0 Check the output
device #0. (please refer to
wiring diagram to determine
which device is attached)"

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)

TM Transmission TE 17 FF.01en
71.00 520225 4 Analog output 1 (wires A04 & Controller reverts to a The output wires of the "Check the wiring between
A05) related fault : output "limp home" mode analog output 1 are shorted the controller and the output
1 DANA TE 17 FULL FLOW

wires are shorted to each to each other, or the sense device #1 Check the output
other, or the sense line is line is shorted to battery +, or device #1. (please refer to
shorted to battery +, or the the plus line is shorted to wiring diagram to determine
plus line is shorted to ground ground which device is attached)"

71.01 520225 3 Analog output 1 (wires A04 & Controller reverts to a An output wire of the analog "Check the wiring between
A05) related fault : the output "limp home" mode output 1 is not connected, or the controller and the output
plus line is shorted to battery its plus line is shorted to device #1 Check the output
+ battery +, or output device #1 device #1. (please refer to
is defect. wiring diagram to determine
which device is attached)"

71.02 520225 6 Analog output 1 (wires A04 & Controller reverts to a The current of the analog "Check the wiring between
A05) related fault : the output "shut down" mode and will output 1 is exceeding 1400 the controller and the output
current exceeds 1400 mA force neutral 0 mA. device #1 Check the output
or/and the output plus line is device #1. (please refer to
shorted to battery +. wiring diagram to determine
which device is attached)"

71.03 520225 8 Analog output 1 (wires A04 & Controller reverts to a The current of the analog "Check the wiring between
A05) related fault : the output "limp home" mode output 1 is out of range. the controller and the output
current is out of range, occurs device #1 Check the output
when the load has the device #1. (please refer to
incorrect impedance wiring diagram to determine
which device is attached)"

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


65/94
TECHNICAL MANUAL
66/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
71.09 520225 5 Analog output 1 (wires A04 & Controller reverts to a The wire of the analog output "Check the wiring between
A05) related fault : the output "limp home" mode 1 is not connected the controller and the output
is not connected device #1 Check the output
device #1. (please refer to
wiring diagram to determine
which device is attached)"

72.00 520226 4 Analog output 2 (wires A06 & Controller reverts to a The output wires of the "Check the wiring between
A07) related fault : output "limp home" mode analog output 2 are shorted the controller and the output
wires are shorted to each to each other, or the sense device #2 Check the output
other, or the sense line is line is shorted to battery +, or device #2. (please refer to
shorted to battery +, or the the plus line is shorted to wiring diagram to determine
plus line is shorted to ground ground which device is attached)"

72.01 520226 3 Analog output 2 (wires A06 & Controller reverts to a An output wire of the analog "Check the wiring between
A07) related fault : the output "limp home" mode output 2 is not connected, or the controller and the output
plus line is shorted to battery its plus line is shorted to device #2 Check the output
+ battery +, or output device #2 device #2. (please refer to
is defect. wiring diagram to determine
which device is attached)"

72.02 520226 6 Analog output 2 (wires A06 & Controller reverts to a The current of the analog "Check the wiring between
A07) related fault : the output "shut down" mode and will output 2 is exceeding 1400 the controller and the output
current exceeds 1400 mA force neutral 0 mA. device #2 Check the output
or/and the output plus line is device #2. (please refer to
shorted to battery +. wiring diagram to determine
which device is attached)"

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)

TM Transmission TE 17 FF.01en
72.03 520226 8 Analog output 2 (wires A06 & Controller reverts to a The current of the analog "Check the wiring between
A07) related fault : the output "limp home" mode output 2 is out of range. the controller and the output
1 DANA TE 17 FULL FLOW

current is out of range, occurs device #2 Check the output


when the load has the device #2. (please refer to
incorrect impedance wiring diagram to determine
which device is attached)"

72.09 520226 5 Analog output 2 (wires A06 & Controller reverts to a The wire of the analog output "Check the wiring between
A07) related fault : the output "limp home" mode 2 is not connected the controller and the output
is not connected device #2 Check the output
device #2. (please refer to
wiring diagram to determine
which device is attached)"

73.00 520227 4 Analog output 3 (wires A08 & Controller reverts to a The output wires of the "Check the wiring between
A09) related fault : output "limp home" mode analog output 3 are shorted the controller and the output
wires are shorted to each to each other, or the sense device #3, Check the output
other, or the sense line is line is shorted to battery +, or device #3. (please refer to
shorted to battery +, or the the plus line is shorted to wiring diagram to determine
plus line is shorted to ground ground which device is attached)"

73.01 520227 3 Analog output 3 (wires A08 & Controller reverts to a An output wire of the analog "Check the wiring between
A09) related fault : the output "limp home" mode output 3 is not connected, or the controller and the output
wire plus line is shorted to its plus line is shorted to device #3, Check the output
battery + battery +, or output device #3 device #3. (please refer to
is defect. wiring diagram to determine
which device is attached)"

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


67/94
TECHNICAL MANUAL
68/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
73.02 520227 6 Analog output 3 (wires A08 & Controller reverts to a The currect of the analog "Check the wiring between
A09) related fault : the output "shut down" mode and will output 3 is exceeding 1400 the controller and the output
current exceeds 1400 mA force neutral 0 mA. device #3, Check the output
or/and the output plus line is device #3. (please refer to
shorted to battery +. wiring diagram to determine
which device is attached) "

73.03 520227 8 Analog output 3 (wires A08 & Controller reverts to a The current of the analog "Check the wiring between
A09) related fault : the output "limp home" mode output 3 is out of range. the controller and the output
current is out of range, occurs device #3, Check the output
when the load has the device #3. (please refer to
incorrect impedance wiring diagram to determine
which device is attached)"

73.09 520227 5 Analog output 3 (wires A08 & Controller reverts to a The output wire of analog "Check the wiring between
A09) related fault : the output "limp home" mode output 3 is not connected the controller and the output
is not connected device #3, Check the output
device #3. (please refer to
wiring diagram to determine
which device is attached)"

74.00 520228 4 Analog output 4 (wires B01) Controller will flag the The output wire of analog "Check the wiring between
related fault : output wire is fault, but no actions will be output 4 is shorted to ground. the controller and the output
shorted to ground. taken. device #4, Check the output
device #4. (please refer to
wiring diagram to determine
which device is attached)"

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)

TM Transmission TE 17 FF.01en
74.01 520228 3 Analog output 4 (wires B01) Controller will flag the The output wire of analog "Check the wiring between
related fault : output wire is fault, but no actions will be output 4 is shorted to battery the controller and the output
1 DANA TE 17 FULL FLOW

shorted to battery +, or not taken. +, or not connected. device #4, Check the output
connected. device #4. (please refer to
wiring diagram to determine
which device is attached) "

75.00 520229 4 Analog output 5 (wires B03) Controller will flag the The output wire of analog "Check the wiring between
related fault : output wire is fault, but no actions will be output 5 is shorted to ground. the controller and the output
shorted to ground. taken. device #5, Check the output
device #5. (please refer to
wiring diagram to determine
which device is attached)"

75.01 520229 3 Analog output 5 (wires B03) Controller will flag the The output wire of analog "Check the wiring between
related fault : output wire is fault, but no actions will be output 5 is shorted to battery the controller and the output
shorted to battery +, or not taken. +, or not connected. device #5, Check the output
connected. device #5. (please refer to
wiring diagram to determine
which device is attached)"

76.00 520230 4 Analog output 6 (wires B05) Controller will flag the The output wire of analog "Check the wiring between
related fault : output wire is fault, but no actions will be output 6 is shorted to ground. the controller and the output
shorted to ground. taken. device #6, Check the output
device #6. (please refer to
wiring diagram to determine
which device is attached)"

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


69/94
TECHNICAL MANUAL
70/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
76.01 520230 3 Analog output 6 (wires B05) Controller will flag the The output wire of analog "Check the wiring between
related fault : output wire is fault, but no actions will be output 6 is shorted to battery the controller and the output
shorted to battery +, or not taken. +, or not connected. device #6, Check the output
connected. device #6. (please refer to
wiring diagram to determine
which device is attached)"

76.02 520230 6 Analog output 6 (wires B05) Controller will flag the The output of analog output 6 "Check the wiring between
related fault : the output fault, but no actions will be is exceeding 1400 mA. the controller and the output
current exceeds 1400 mA. taken. device #6, Check the output
device #6. (please refer to
wiring diagram to determine
which device is attached)"

76.03 520230 8 Analog output 6 (wires B05) Controller will flag the The output of analog output 6 "Check the wiring between
related fault : the output fault, but no actions will be is out of range. the controller and the output
current is out of range, occurs taken. device #6, Check the output
when the load has the device #6. (please refer to
incorrect impedance. wiring diagram to determine
which device is attached)"

76.09 520230 5 Analog output 6 (wires B05) Controller will flag the The output wire of analog "Check the wiring between
related fault : the output is not fault, but no actions will be output 6 is not connected the controller and the output
connected taken. device #6, Check the output
device #6. (please refer to
wiring diagram to determine
which device is attached)"

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)

TM Transmission TE 17 FF.01en
77.02 520239 31 All proportional valve grounds Controller reverts to a One or more proportional Check the combined fault,
are switched off due to an "shut down" mode and will valves have an ove current, and see the troubleshooting
1 DANA TE 17 FULL FLOW

over current on one or more force neutral 0 not that this fault will be for that fault.
proportional valves. combined with a 70.02 and/or
71.02 and/or 72.02 and/or
73.02.

80.00 520231 4 Digital output 0 (wire A10) Controller reverts to a Digital output DIG0 is shorted Check the wiring between
related fault : output is "limp home" mode to ground. the controller and the device
shorted to ground attached. Check the
attached device. (please
refer to wiring diagram to
determine which device is
attached)

80.01 520231 3 Digital output 0 (wire A10) Controller reverts to a Digital output DIG0 is shorted Check the wiring between
related fault : output is "limp home" mode to battery +. the controller and the device
shorted to battery + attached. Check the
attached device. (please
refer to wiring diagram to
determine which device is
attached)

80.09 520231 5 Digital output 0 (wire A10) Controller reverts to a Digital output DIG0 is not Check the wiring between
related fault : output is not "limp home" mode connected. the controller and the device
connected attached. Check the
attached device. (please
refer to wiring diagram to
determine which device is
attached)

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


71/94
TECHNICAL MANUAL
72/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
81.00 520232 4 Digital output 1 (wire A15) Controller reverts to a Digital output DIG1 is shorted Check the wiring between
related fault : output is "limp home" mode to ground. the controller and the device
shorted to ground attached. Check the
attached device. (please
refer to wiring diagram to
determine which device is
attached)

81.01 520232 3 Digital output 1 (wire A15) Controller reverts to a Digital output DIG1 is shorted Check the wiring between
related fault : output is "limp home" mode to battery +. the controller and the device
shorted to battery + attached. Check the
attached device. (please
refer to wiring diagram to
determine which device is
attached)

81.09 520232 5 Digital output 1 (wire A15) Controller reverts to a Digital output DIG1 is not Check the wiring between
related fault : output is not "limp home" mode connected the controller and the device
connected attached. Check the
attached device. (please
refer to wiring diagram to
determine which device is
attached)

82.00 520233 4 Digital output 2 (wire A16) Controller reverts to a Digital output DIG2 is shorted Check the wiring between
related fault : output is "limp home" mode to ground. the controller and the device
shorted to ground attached. Check the
attached device. (please
refer to wiring diagram to
determine which device is
attached)

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)

TM Transmission TE 17 FF.01en
82.01 520233 3 Digital output 2 (wire A16) Controller reverts to a Digital output DIG2 is shorted Check the wiring between
related fault : output is "limp home" mode to battery +. the controller and the device
1 DANA TE 17 FULL FLOW

shorted to battery + attached. Check the


attached device. (please
refer to wiring diagram to
determine which device is
attached)

82.09 520233 5 Digital output 2 (wire A16) Controller reverts to a Digital output DIG2 is not Check the wiring between
related fault : output is not "limp home" mode connected the controller and the device
connected attached. Check the
attached device. (please
refer to wiring diagram to
determine which device is
attached)

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


73/94
TECHNICAL MANUAL
74/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
83.00 520234 3 Digital output 3 (wire A20) Controller reverts to a Digital output DIG3 is shorted Check the wiring between
related fault : output is "limp home" mode to battery +. the controller and the device
shorted to battery + attached. Check the
attached device. (please
refer to wiring diagram to
determine which device is
attached)

83.01 520234 4 Digital output 3 (wire A20) Controller reverts to a Digital output DIG3 is not Check the wiring between
related fault : output is not "limp home" mode connected or shorted to the controller and the device
connected, or shorted to ground. attached. Check the
ground attached device. (please
refer to wiring diagram to
determine which device is
attached)

90.xx - 520192 System Error. Controller reverts to a Software related fault. Contact Spicer Off-Highway
99.xx "shut down" mode and will and inform the fault code
force neutral 0 and the time that is was
active.

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)

TM Transmission TE 17 FF.01en
9001 520432 1 SYSERR_OUT_OF_TABLES
1 DANA TE 17 FULL FLOW

9002 520432 2 SYSERR_DAQ_NOINIT

9003 520432 3 SYSERR_WRONG_SIGNAL


_INDEX

9004 520432 4 SYSERR_WRONG_STATRE


G_INDEX

9005 520432 5 SYSERR_WRONG_BUTTON


_INDEX

9006 520432 6 SYSERR_WRONG_TABLE_I


NDEX

9007 520432 7 SYSERR_WRONG_DISPLA


Y_MODE

9008 520432 8 SYSERR_WRONG_SPEED_


INDEX

9009 520432 9 SYSERR_WRONG_OUTPUT


_INDEX

9011 520432 11 SYSERR_LOCAL_ARRAY_T


OO_SMALL

9012 520432 12 SYSERR_TABLE_VALUE_O


OR

9013 520432 13 SYSERR_INDEX_OOR

9014 520432 14 SYSERR_Y2X_NON_MONO

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


75/94
TECHNICAL MANUAL
76/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
9015 520432 15 SYSERR_SETTING_CORRU
PT

9016 520432 16 SYSERR_ILLEGAL_ISR_EN


TRY

9017 520432 17 SYSERR_POWERFAIL

9018 520432 18 SYSERR_DIV_BY_0_ATTEM


PT

9019 520432 19 SYSERR_ILLEGAL_FAULTC


ODE

90.90 520352 31 Wrong firmware is flashed The controller reverts to a Wrong firmware is flashed Flash the correct firmware
into the APC200. "shut down" mode and will into the APC200 into the APC200
force neutral 0

9101 520433 1 SYSERR_OUTPUT_FEATU


RE_ASSIGNMENT

9102 520433 2 SYSERR_INVALID_SHIFTLE


VER

9103 520433 3 SYSERR_INVALID_ALGORI


THM_CALL

9110 520433 6 SYSERR_INVALID_SEQUE


NCE

9111 520433 7 SYSERR_INVALID_STEP

9112 520433 8 SYSERR_INVALID_TIMEOU


TACTION

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)

TM Transmission TE 17 FF.01en
9150 520439 10 SYSERR_VALUE_OOR
1 DANA TE 17 FULL FLOW

9151 520439 11 SYSERR_VALUE_OOR +


OOR_SHIFTTYPE

9152 520439 12 SYSERR_VALUE_OOR +


OOR_FG_PARAMETER

9153 520439 13 SYSERR_VALUE_OOR +


OOR_INIT_DIV_BY_0

9154 520439 14 SYSERR_VALUE_OOR +


OOR_GDE_POINT_BLANK

9155 520439 15 SYSERR_VALUE_OOR +


OOR_SEQ_DIV_BY_0

9157 520439 17 SYSERR_VALUE_OOR +


OOR_SHIFTTIMEOUT

9158 520439 18 SYSERR_VALUE_OOR +


OOR_SEQ_SU_TOLO

9159 520439 19 SYSERR_VALUE_OOR +


OOR_SEQ_SU_TOHI

9160 520439 20 "SYSERR_VALUE_OOR +


OOR_OFFG_DIRCLUTCH_T
IMEOUT"

9161 520439 21 "SYSERR_VALUE_OOR +


OOR_OFFG_RGCLUTCH_TI
MEOUT"

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


77/94
TECHNICAL MANUAL
78/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
9170 520439 30 SYSERR_VALUE_OOR +
OOR_SEQSGM_TIME

92.00 520434 0 SYSERR_ALGINIT

92.01 520434 1 Gearpattern doesn't contain a Controller reverts to a Software related fault. Contact Spicer Off-Highway
direction "shut down" mode and will and inform the fault code
force neutral 0 and the time that is was
active.

92.02 520434 2 duplicate direction pattern Controller reverts to a Software related fault. Contact Spicer Off-Highway
"shut down" mode and will and inform the fault code
force neutral 0 and the time that is was
active.

92.03 520434 3 duplicate gear pattern Controller reverts to a Software related fault. Contact Spicer Off-Highway
"shut down" mode and will and inform the fault code
force neutral 0 and the time that is was
active.

92.04 520434 4 duplicate bump pattern Controller reverts to a Software related fault. Contact Spicer Off-Highway
"shut down" mode and will and inform the fault code
force neutral 0 and the time that is was
active.

92.06 520434 6 digital input pattern faulty Controller reverts to a Software related fault. Contact Spicer Off-Highway
"shut down" mode and will and inform the fault code
force neutral 0 and the time that is was
active.

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)

TM Transmission TE 17 FF.01en
92.07 520434 7 digital input pattern interferes Controller reverts to a Software related fault. Contact Spicer Off-Highway
with cab pattern "shut down" mode and will and inform the fault code
1 DANA TE 17 FULL FLOW

force neutral 0 and the time that is was


active.

92.08 520434 8 digital input: Neutral lock Controller reverts to a Software related fault. Contact Spicer Off-Highway
definition faulty "shut down" mode and will and inform the fault code
force neutral 0 and the time that is was
active.

92.09 520434 9 duplicate digital input Controller reverts to a Software related fault. Contact Spicer Off-Highway
assignment "shut down" mode and will and inform the fault code
force neutral 0 and the time that is was
active.

92.10 520434 10 duplicate digital output Controller reverts to a Software related fault. Contact Spicer Off-Highway
assignment "shut down" mode and will and inform the fault code
force neutral 0 and the time that is was
active.

92.11 520434 11 Digital output selected on Controller reverts to a Software related fault. Contact Spicer Off-Highway
unsupported wire "shut down" mode and will and inform the fault code
force neutral 0 and the time that is was
active.

92.12 520434 12 digital output pattern faulty Controller reverts to a Software related fault. Contact Spicer Off-Highway
"shut down" mode and will and inform the fault code
force neutral 0 and the time that is was
active.

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


79/94
TECHNICAL MANUAL
80/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
92.13 520434 13 digital output selected on Controller reverts to a Software related fault. Contact Spicer Off-Highway
transmission wire "shut down" mode and will and inform the fault code
force neutral 0 and the time that is was
active.

92.14 520434 14 error in speed sensor 1-2 Controller reverts to a Software related fault. Contact Spicer Off-Highway
assignment "shut down" mode and will and inform the fault code
force neutral 0 and the time that is was
active.

92.15 520434 15 error in speed sensor 3 Controller reverts to a Software related fault. Contact Spicer Off-Highway
assignment "shut down" mode and will and inform the fault code
force neutral 0 and the time that is was
active.

92.16 520434 16 duplicate speed sensor Controller reverts to a Software related fault. Contact Spicer Off-Highway
assignment "shut down" mode and will and inform the fault code
force neutral 0 and the time that is was
active.

92.17 520434 17 invalid supply voltage Controller reverts to a Software related fault. Contact Spicer Off-Highway
selected "shut down" mode and will and inform the fault code
force neutral 0 and the time that is was
active.

92.18 520434 18 duplicate analog input pattern Controller reverts to a Software related fault. Contact Spicer Off-Highway
"shut down" mode and will and inform the fault code
force neutral 0 and the time that is was
active.

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)

TM Transmission TE 17 FF.01en
92.19 520434 19 pressure sensor wires Controller reverts to a Software related fault. Contact Spicer Off-Highway
interfere with analog input "shut down" mode and will and inform the fault code
1 DANA TE 17 FULL FLOW

wires force neutral 0 and the time that is was


active.

92.20 520434 20 wrong configuration regarding Controller reverts to a Software related fault. Contact Spicer Off-Highway
servo motor or brake valve "shut down" mode and will and inform the fault code
(on analog outputs 4-5-6) force neutral 0 and the time that is was
active.

92.21 520434 21 wrong configuration: Controller reverts to a Software related fault. Contact Spicer Off-Highway
automatic parking brake "shut down" mode and will and inform the fault code
function selected without an force neutral 0 and the time that is was
enabled throttle pedal active.

92.30 520434 30 wrong configuration regarding Controller reverts to a Software related fault. Contact Spicer Off-Highway
full flow selection and past "shut down" mode and will and inform the fault code
digital error treatment force neutral 0 and the time that is was
active.

9250 520440 1 "SYSERR_TRANSM_CONT


ROL +
TC_ATTEMPT_TO_LOCK_D
IR_CLUTCHES"

9251 520440 2 "SYSERR_TRANSM_CONT


ROL +
TC_ATTEMPT_TO_LOCK_R
G_CLUTCHES"

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


81/94
TECHNICAL MANUAL
82/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
9252 520440 3 "SYSERR_TRANSM_CONT
ROL +
TC_MODMODE_OVERRULE
D_WITH_GDE_TABLE"

93.00 520435 0 failed initialisation of essential The controller reverts to a Memory conflict in flash Reset controller
controller data in flash "shut down" mode and will memory
memory, caused by memory force neutral 0
conflict

93.01 520435 1 failed initialisation of essential The controller reverts to a Memory conflict in flash Reset controller
controller data in flash "shut down" mode and will memory
memory, caused by memory force neutral 0
conflict

93.02 520435 2 failed initialisation of essential The controller reverts to a Memory conflict in flash Reset controller
controller data in flash "shut down" mode and will memory
memory, caused by memory force neutral 0
conflict

93.03 520435 3 failed initialisation of essential The controller reverts to a Memory conflict in flash Reset controller
controller data in flash "shut down" mode and will memory
memory, caused by memory force neutral 0
conflict

93.04 520435 4 failed initialisation of essential The controller reverts to a Memory conflict in flash Reset controller
controller data in flash "shut down" mode and will memory
memory, caused by memory force neutral 0
conflict

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)

TM Transmission TE 17 FF.01en
93.05 520435 5 failed initialisation of essential The controller reverts to a Memory conflict in flash Reset controller
controller data in flash "shut down" mode and will memory
1 DANA TE 17 FULL FLOW

memory, caused by memory force neutral 0


conflict

93.09 520435 9 failed initialisation of essential The controller reverts to a Memory conflict in flash Reset controller
controller data in flash "shut down" mode and will memory
memory, caused by memory force neutral 0
conflict

93.10 520435 10 Initialisation of statistical data Controller will flag the Memory conflict in flash Restart controller
in flash memory, caused by fault, but no actions will be memory
firmware upgrade or memory taken.
conflict

93.11 520435 11 Initialisation of logged error Controller will flag the Memory conflict in flash Restart controller
data in flash memory, caused fault, but no actions will be memory
by firmware upgrade or taken.
memory conflict

94.00 520436 0 failed initialisation of essential The controller reverts to a Memory conflict in flash Contact maintenance for
controller data in flash "shut down" mode and will memory troubleshooting
memory, caused by memory force neutral 0
conflict

94.01 520436 1 failed initialisation of essential The controller reverts to a Memory conflict in flash Contact maintenance for
controller data in flash "shut down" mode and will memory troubleshooting
memory, caused by memory force neutral 0
conflict

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


83/94
TECHNICAL MANUAL
84/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
94.02 520436 2 failed initialisation of essential The controller reverts to a Memory conflict in flash Contact maintenance for
controller data in flash "shut down" mode and will memory troubleshooting
memory, caused by memory force neutral 0
conflict

94.03 520436 3 failed initialisation of essential The controller reverts to a Memory conflict in flash Contact maintenance for
controller data in flash "shut down" mode and will memory troubleshooting
memory, caused by memory force neutral 0
conflict

94.04 520436 4 failed initialisation of essential The controller reverts to a Memory conflict in flash Contact maintenance for
controller data in flash "shut down" mode and will memory troubleshooting
memory, caused by memory force neutral 0
conflict

94.05 520436 5 failed initialisation of essential The controller reverts to a Memory conflict in flash Contact maintenance for
controller data in flash "shut down" mode and will memory troubleshooting
memory, caused by memory force neutral 0
conflict

94.09 520436 9 failed initialisation of essential The controller reverts to a Memory conflict in flash Contact maintenance for
controller data in flash "shut down" mode and will memory troubleshooting
memory, caused by memory force neutral 0
conflict

9500 520437 0

9570 520437 20 SYSERR_SAVE_LOG2FLAS


H_FAILED

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)

TM Transmission TE 17 FF.01en
95.71 520347 31 Data in the APC200 is not The controller reverts to a Wrong APT file (data file) is in "Download an APT file
compatible with the data "shut down" mode and will the APC200 (typically after compatible with the active
1 DANA TE 17 FULL FLOW

expected by the APC200 force neutral 0 APC200 firmware upgrade) firmware into the APC200If
firmware the error code still persists,
the data flash may be
corrupt (contact Spicer Off-
Highway)"

9572 520437 22 SYSERR_FLASH_ILLEGAL_


ADDRESSRANGE

9573 520437 23 SYSERR_FLASH_ILLEGAL_


ACCESS

9990 520438 0 SYSERR_HARDWARE_ERR


OR

9991 520438 1 SYSERR_HSL_CPU_OVERL


OAD

9992 520438 2 SYSERR_MSL_CPU_OVER


LOAD

9993 520438 3 SYSERR_LSL_CPU_OVERL


OAD

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


85/94
TECHNICAL MANUAL
86/94
Dana SPN FMI Explanation Controller's action Fault cause Troubleshooting
(Fault (IQAN (dec)

X158715en / B / 18 Jan 2016


code) Display)
TECHNICAL MANUAL

TM Transmission TE 17 FF.01en
99.95 520394 31 "CAN peak load detected : Controller will reply on the Overload of incomming CAN No action requested
APC200 temporarily could not CAN messages which are messages to the APC200
process all incoming available in its buffer.
messages, due to an
excessive peak of CAN
requests."

9999 520438 9 SYSERR_HARDWARE_CALI


BRATION

xx.49 Fault with undefined cause. Controller will flag the fault Software related fault. Contact Spicer Off-Highway
- action will depend on the and inform the fault code
fault. and the time that is was
active.

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
1 DANA TE 17 FULL FLOW TECHNICAL MANUAL

1.9 Exceed codes

Exceed SPN FMI Explanation Controller's action


code (IQAN (dec)
Display)

E0.01 520417 15 The vehicle speed is too high The controller will disable the
to make the requested downshift in order to protect
downshift. the transmission, until the
vehicle speed comes below
the downshift limit.

E1.01 520418 15 The vehicle speed is too high The controller will not allow
to make the requested the direction change to
direction change. protect the transmission and
will place the transmission in
neutral, until the vehicle
speed comes below the
direction change vehicle
speed limit.

E2.01 520419 15 The engine speed is too high The controller will not allow
to make the requested the direction change or re-
direction change or the engagement of the direction,
requested re-engagement of until the engine speed comes
the direction. below the direction change or
the direction re-engagement
engine speed limit.

E3.00 520420 14 The reduced vehicle speed The controller is limiting the
limitation is active. vehicle speed to the reduced
vehicle speed limit.

E3.01 520420 15 The reduced vehicle speed The controller is limiting the
limitation is active, however vehicle speed to the reduced
the vehicle speed is above vehicle speed limit, but
the limit. detects a higher vehicle
speed.

E3.02 520420 16 The vehicle speed is above The controller is limiting the
the maximum vehicle speed vehicle speed to the
limit. maximum vehicle speed limit,
but detects a higher vehicle
speed.

E4.00 520421 17 An abnormal deceleration is "The controller detected an


detected. abnormal deceleration, and
will disable the automatic
shifting for a certain time."

E4.01 520421 15 An abnormal acceleration is "The controller detected an


detected. abnormal acceleration, and
will disable the automatic
shifting for a certain time."

E5.01 520416 13 Time in gear exceeded the The controller detected that
time to re-calibrate the the time in gear exceeded the
transmission. time to re-calibrate the
transmission.

87/94
X158715en / B / 18 Jan 2016 Copyright © (2016) Konecranes Lifttrucks. All rights reserved.
TM Transmission TE 17 FF.01en
TECHNICAL MANUAL 1 DANA TE 17 FULL FLOW

Exceed SPN FMI Explanation Controller's action


code (IQAN (dec)
Display)

E6.00 520422 31 Operator is not seated with The controller detected that
shift lever not in neutral the operator is not seated
and/or the parking brake not with the shift lever not in
activated. neutral and/or the parking
brake not activated.

E7.01 520423 15 Turbine speed exceeds the The controller detects that the
limit turbine speed is above its
limit. The controller will force
engine idle to prevent
damage.

E8.01 520424 15 Condition to change low high The controller detected that
range selector not fulfilled. the machine is still driving.
Machine has to stand still.

E9.01 520425 15 Condition to change from 4wd The controller detected that
to 2wd or visa versa not the machine is still driving.
fulfilled. Machine has to stand
still.

88/94
X158715en / B / 18 Jan 2016 Copyright © (2016) Konecranes Lifttrucks. All rights reserved.
TM Transmission TE 17 FF.01en
1 DANA TE 17 FULL FLOW TECHNICAL MANUAL

1.10 Transmission calibration error codes


Error codes that are generated during calibration

Error code Explanation Controller’s action

APC200 or TCon expects the Move the gear lever to neutral


gear lever to be in neutral, but
the gear lever is in another
position (Forwards or
Reverse)

The parking brake is not Apply the parking brake


activated.

APC200 or TCon detects that Check that the parking brake


the machine is moving. is applied. When it is, the
operator must stop the
machine using the foot brake.
When the machine has
stopped, APC200 or TCon
asks the operator to move the
gear lever to the Forwards
position before calibration
continues.

The engine RPM is too low Increase the engine RPM.


for calibration to be
implemented.

The engine RPM is too high Reduce the engine RPM.


for calibration to be
implemented.

After the engine RPM have


been too high or too low, the
display shows that the engine
revs are within the limit
values for calibration.

When the temperature in the Use the M button on APC200


transmission during or TCon to go back to “Heat”
transmission calibration mode and the S button to
becomes too low, the display activate the mode. The
shows the true temperature. transmission must now be
heated until the temperature
exceeds 60°C. Then return to
the original mode using the M
button and activate the mode
to continue with the
calibration.

89/94
X158715en / B / 18 Jan 2016 Copyright © (2016) Konecranes Lifttrucks. All rights reserved.
TM Transmission TE 17 FF.01en
TECHNICAL MANUAL 1 DANA TE 17 FULL FLOW

Calibration code Explanation

E.1.XX Touch pressure Calibration

E.2.XX Optimize fill time

E.3.XX Pressure current calibration

90/94
X158715en / B / 18 Jan 2016 Copyright © (2016) Konecranes Lifttrucks. All rights reserved.
TM Transmission TE 17 FF.01en
XX Type Explanation Controller's action Fault cause Troubleshooting

1->5, 7- Unexpected Algorithm Stop calibration of clutch xx. Engine does not respond to Continue calibration to

X158715en / B / 18 Jan 2016


>9, 11- response during calibration. Wait for continue request. target engine speed. Vehicle identify if all clutches

TM Transmission TE 17 FF.01en
>13, 15, started moving. Bad experience same problem.
17->24 parameter configuration. Download correct parameter
1 DANA TE 17 FULL FLOW

file and restart calibration.


Check if vehicle starts moving
during calibration. Check
engine speed response.

06 During calibration the turbine Controller will flag the error Turbine speed does not reach Measure clutch pressure to
speed signal does not reach and will abort calibration of minimum value during shifting detect clutch leakage. Check
a minimum value clutch with error code iteration process caused by speed sensor signal (can be
slipping clutch or bad turbine in relation with 42.04 and/or
speed signal. 42.05 during normal
operation and with E1.26
during touch pressure
calibration). Check stall
speed to detect slipping
clutch

10 Transmission failure during Calibration is stopped Caused by shutdown error Resolve cause of shutdown
calibration code during calibration error code during calibration
Example: 20.60 error code
during calibration

14 During calibration the turbine Controller will flag the error Turbine speed does not Measure clutch pressure to
speed signal does not and will abort calibration of decrease caused by too high detect clutch leakage. Check
decrease clutch with error code internal leakage and/or speed sensor signal ( must
slipping clutch. Bad turbine be in relation with 42.04 and/
speed signal or42.05 during normal
operation and with E1.26
during touch pressure
calibration)

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


91/94
TECHNICAL MANUAL
92/94
XX Type Explanation Controller's action Fault cause Troubleshooting

16 During calibration the turbine Controller will flag the error Faulty turbine speed sensor. Check speed sensor signal

X158715en / B / 18 Jan 2016


TECHNICAL MANUAL

speed signal is too low to and will abort calibration of Sticking or burnt clutch which ( must be in relation with

TM Transmission TE 17 FF.01en
start calibration clutch with error code causes turbine drop before 42.04 and/or 42.05 during
pressure is applied. normal operation and with
E1.25 during touch pressure
calibration).

25 Early touch detection during Controller will flag the error Too much drag because of Perform autocalibration at
touch pressure calibration. and will abort touch pressure thick oil Sticking or burnt higher temperature
Too much drag calibration of clutch with error clutch with causes turbine (90-100°C) Check speed
code drop before pressure is sensor signal (must be in
applied Speed sensor relation with 42.04 and/or
problem Faulty proportional 42.05 during normal
valve operation) Check and if
necessary change
proportional valve

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


1 DANA TE 17 FULL FLOW
XX Type Explanation Controller's action Fault cause Troubleshooting

26 No touch detection during Controller will flag the error Slipping clutch or too high Measure clutch pressure to

X158715en / B / 18 Jan 2016


touch pressure calibration. and will abort touch pressure internal leakage Speed detect clutch leakage Check

TM Transmission TE 17 FF.01en
calibration of clutch with error sensor problem Faulty speed sensor signal ( must
code proportional valve be in relation with 42.04
1 DANA TE 17 FULL FLOW

and/or 42.05 during normal


operation) Check and if
necessary change
proportional valve

28 Turbine speed does not reach Controller will flag the error Slipping clutch or too high Measure clutch pressure to
value = 0 rpm at end of and will abort release internal leakage Speed detect clutch leakage Check
closing phase of the touch pressure calibration of clutch sensor problem Faulty speed sensor signal ( must
pressure calibration with error code proportional valve be in relation with 42.04
and/or 42.05 during normal
operation) Check and if
necessary change
proportional valve

29 Turbine speed signal does Controller will flag the error Too much drag because of Perform autocalibration at
not reach a high enough and will abort release thick oil Sticking or burnt higher temperature
value during release phase of pressure calibration of clutch clutch which causes turbine (90-100°C) Check speed
the touch pressure with error code drop, before pressure is sensor signal (must be in
calibration. applied. Speed sensor relation with 42.04 and/or
problem Faulty proportional 42.05 during normal
valve operation) Check and if
necessary change
proportional valve

Copyright © (2016) Konecranes Lifttrucks. All rights reserved.


93/94
TECHNICAL MANUAL
TECHNICAL MANUAL 1 DANA TE 17 FULL FLOW

94/94
X158715en / B / 18 Jan 2016 Copyright © (2016) Konecranes Lifttrucks. All rights reserved.
TM Transmission TE 17 FF.01en
www.konecranes.com

Corporate HQ
Region EMEA HQ
Hyvinkää, Finland

Region Americas HQ
Springfield, Ohio Region APAC HQ
Shanghai, China

Main production sites


Sales and service locations

This document and the information contained herein, is the exclusive property of Konecranes
Lifttrucks and represents a non-public, confidential and proprietary trade secret that may not be
reproduced, disclosed to other parties, altered or otherwise employed in any manner whatsoever
without the express written consent of Konecranes Lifttrucks. © 2016 Konecranes Lifttrucks. All rights
reserved. ‘Konecranes’, ‘Lifting Businesses’ and C are either registered trademarks or trademarks of
Konecranes Lifttrucks.Copyright © (2016) Konecranes Lifttrucks. All rights reserved.

You might also like