You are on page 1of 1

Reinforcement details

Girder section
150 150
180mm

14 Φ 12, L =20700 mm 2Φ12 shear reinforcement

1320

1320
(nominal bars) Φ 12, L = 3240 mm.
1250mm

300
74 Φ 12 shear reinf. for int.
10 Φ 32 for interior & 12 350mm & 70 Φ 12 for ext. girders,
Φ 32 for exterior girders of L= 3240 mm.
variable length.

74 Φ 12 ties. for int. & 70 Φ 12 for ext. girders, L= 400 mm.


Longitudinal girder
(Temp reinf. For the deck slab) Provide 17 Φ 12 c/c 450 mm , L=20870 mm
Dw = 1430 mm

a b c d e d c b a

2040mm 2040mm 2040mm 2040mm 4080mm 2040mm 2040mm 2040mm 2040mm

20.8 20800 mm

4 Φ 32 for interior & 5 Φ 32 for exterior girders L =25080mm

5 Φ 32 for interior & 5 Φ 32 for exterior girders L =10595mm

1 Φ 32 for interior & 2 Φ 32 for exterior girders L =6515mm

Shear reinforcements
a= 9 Φ 12 c/c 240 mm for interior & 7 Φ 12 c/c 300 mm for exterior girders, L= 3240mm on both sides.
b= 7 Φ 12 c/c 300 mm for interior & 7 Φ 12 c/c 300 mm for exterior girders, L= 3240mm on both sides.
c= 7 Φ 12 c/c 300 mm for interior & 7 Φ 12 c/c 300 mm for exterior girders, L= 3240mm on both sides.
d= 7 Φ 12 c/c 300 mm for interior & 7 Φ 12 c/c 300 mm for exterior girders, L= 3240mm on both sides.
e= 14 Φ 12 c/c 300 mm for interior & 14 Φ 12 c/c 300 mm for exterior girders, L= 3240mm.