PUMP AND GEN SPECIFICATIONS 05/28/2021

Pump, Genset, Panel Lookup


VSD Panel settings
Pump Make Pump Model Motor Make Motor Type Motor Size (kW) Motor Rated Motor Rated Recommende Panel Size Min Flow (L/s) BEP FLow Max Flow Head Min BEP Head (m) Shut off Head Shutoff head Pump Motor Total Pump Motor Length PRV Typical
Current (A) Voltage d Gen Size (kW) (L/s) (L/s) Flow (m) (m) (kPa) diameter diameter Length (m) Required? Shroud
(Kva) Prime (mm) (mm) (Yes/No) Diameter Min
(mm) automatic Max
limit to automatic
increase limit to
Min low flow speed & reduce speed Max high
trip (at 50Hz alarm & alarm flow trip (at
Motor Temperature pro-rata (@50Hz pro- (@50Hz pro- 50Hz pro-rata Pressure Control
Max Current Setting (A) (deg C) Bore level set point Bore level control limits Flow set point frequency) rata) rata) frequency) Limits Pump Speed Control Limits
Grundfos SP17-11 Grundfos MS6000 7.5 18.4 / 19.0 400 / 415 30 7.5-13 2.35 4.7 6 118 90 124 1215.2 142.0 95.0 1.493 0.574 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 2.4 3.4 5 6 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP17-14 Grundfos MS6000 9.2 22.4 / 22.6 400 / 415 30 7.5-13 2.35 4.7 6 151 113 157 1538.6 142.0 143.0 1.720 0.604 Yes Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 2.4 3.4 5 6 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP30-10 Grundfos MS6000 9.2 22.4 / 22.6 400 / 415 33 7.5-13 3.6 8.3 10.8 104 77 114 1117.2 142.0 143.0 1.833 0.604 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 3.6 4.6 9.8 10.8 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP30-11 Grundfos MS6000 9.2 22.4 / 22.6 400 / 415 33 7.5-13 3.6 8.3 10.8 112 85 125 1225 142.0 143.0 1.929 0.604 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 3.6 4.6 9.8 10.8 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP17-11 SEMA 9.2kW 9.2 15.4 415 33 7.5-13 2.35 4.7 6 118 90 124 1215.2 142.0 140.0 1.604 0.685 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 2.4 3.4 5 6 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP30-11 SEMA 9.2kW 9.2 15.4 415 33 7.5-13 3.6 8.3 10.8 112 85 125 1225 142.0 140.0 2.010 0.685 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 3.6 4.6 9.8 10.8 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Pleuger NB65-11 Pleuger M6-270-2 11 24 400 33 7.5-13 2.3 4.5 5.4 124 105 140 1372 147.0 144.0 1.483 0.664 No Same as motor rated current 65 alarm / 70 trip TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 2.3 3.3 4.4 5.4 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP46-10 Grundfos MS6000 15 34.0 / 34.0 400 / 415 55 15-22 6.4 12.8 16.8 117 87 135 1323 145.0 143.0 2.096 0.699 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 6.4 7.4 14.8 16.8 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP46-9 Grundfos MS6000 15 34.0 / 34.0 400 / 415 55 15-22 6.4 12.8 16.8 106 78 122 1195.6 145.0 143.0 1.983 0.699 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 6.4 7.4 14.8 16.8 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Pleuger NB84-6 Pleuger M6-400-2 15 32.0 / 32.0 400 55 15-22 6.4 7 8.5 98 93 114 1117.2 192.0 144.0 1.527 0.794 No Same as motor rated current 65 alarm / 70 trip TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 6.4 7.4 7.5 8.5 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Pleuger QT8ELL-4a Pleuger M6-460-2 17.5 38.5 400 55 15-22 6 12 16.5 100 85 108 1058.4 204.0 144.0 1.672 0.876 No Same as motor rated current 65 alarm / 70 trip TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 6 7 14.5 16.5 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP46-12 Grundfos MS6000 18.5 40.5 / 41.0 400 / 415 55 15-22 6.4 12.8 16.8 141 105 162 1587.6 145.0 143.0 2.377 0.754 Yes Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 6.4 7.4 14.8 16.8 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP60-10 Grundfos MS6000 18.5 40.5 / 41.0 400 / 415 55 15-22 8 16.7 20 121 79 143 1401.4 147.0 143.0 2.186 0.783 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 8 9 18 20 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP46-10 SEMA 18.5kW 18.5 36.6 415 55 15-22 6.4 12.8 16.8 117 87 135 1323 145.0 140.0 2.317 0.920 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 6.4 7.4 14.8 16.8 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP46-12 SEMA 18.5kW 18.5 36.6 415 55 15-22 6.4 12.8 16.8 141 105 162 1587.6 145.0 140.0 2.543 0.920 Yes Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 6.4 7.4 14.8 16.8 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP46-9 SEMA 18.5kW 18.5 36.6 415 55 15-22 6.4 12.8 16.8 106 78 122 1195.6 145.0 140.0 2.204 0.920 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 6.4 7.4 14.8 16.8 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP60-10 SEMA 18.5kW 18.5 36.6 415 55 15-22 8 16.7 20 121 79 143 1401.4 147.0 140.0 2.323 0.920 No 174 Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 8 9 18 20 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Pleuger NB84-7(18.5) Pleuger M6-460-2 18.5 39 400 55 15-22 3.4 6.7 8.1 130 111 136 1332.8 192.0 144.0 1.649 0.876 No Same as motor rated current 65 alarm / 70 trip TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 3.4 4.4 7.1 8.1 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP60-12 Grundfos MS6000 22 47.5 / 48.5 400 / 415 55 15-22 8 16.7 20 145 95 172 1685.6 147.0 143.0 2.467 0.814 Yes Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 8 9 18 20 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Pleuger QT8ELL-5a Pleuger M6-600-2 22.5 49 400 55 15-22 6 12 16.5 121 102 131 1283.8 209.0 144.0 1.955 1.016 No Same as motor rated current 65 alarm / 70 trip TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 6 7 14.5 16.5 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Pleuger PN81-6a Pleuger M6-650-2 24.5 53 400 55 26-37 8.47 15.4 17.7 115 90 143.1 1402.38 188.0 144.0 1.951 1.066 No Same as motor rated current 65 alarm / 70 trip TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 8.5 9.5 15.7 17.7 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP77-7 Grundfos MS6000 26 56.0 / 56.0 400 / 415 88 26-37 10.4 21.4 27 121 86 140 1372 178.0 143.0 2.427 0.874 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 10.4 11.4 25 27 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP77-9 Grundfos MS6000 30 64.0 / 65.0 400 / 415 88 26-37 10.4 21.4 27 155 111 178 1744.4 178.0 143.0 2.753 0.944 Yes Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 10.4 11.4 25 27 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP95-7 Grundfos MS6000 30 64.0 / 65.0 400 / 415 88 26-37 13 26.4 34 123 85 148 1450.4 178.0 143.0 2.497 0.944 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 13 14 32 34 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP60-12 SEMA 30kW 30 58.5 415 88 26-37 8 16.7 20 145 95 172 1685.6 147.0 140.0 2.683 1.030 Yes 174 Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 8 9 18 20 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP77-7 SEMA 30kW 30 58.5 415 88 26-37 10.4 21.4 27 121 86 140 1372 178.0 140.0 2.583 1.030 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 10.4 11.4 25 27 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP77-9 SEMA 30kW 30 58.5 415 88 26-37 10.4 21.4 27 155 111 178 1744.4 178.0 140.0 2.839 1.030 Yes Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 10.4 11.4 25 27 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP95-7 SEMA 30kW 30 58.5 415 88 26-37 13 26.4 34 123 85 148 1450.4 178.0 140.0 2.583 1.030 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 13 14 32 34 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Lowara ZR855 5-L6W Lowara L6WR300T405/A HT 30 75.2 415 88 26-37 2.8 12.5 20.9 135 120 140 1372 200.0 144.0 2.171 1.000 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 2.8 3.8 18.9 20.9 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Pleuger PN81-7a Pleuger M6-720-2 31 65 400 88 26-37 8.47 15.4 17.71 134 105 164 1607.2 188.0 144.0 2.136 1.136 Yes Same as motor rated current 65 alarm / 70 trip TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 8.5 9.5 15.7 17.7 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Pleuger PN82-6 Pleuger M6-720-2 31 65 400 88 26-37 9.75 19.5 23.4 126 102 155 1519 188.0 144.0 2.021 1.136 Yes Same as motor rated current 65 alarm / 70 trip TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 9.8 10.8 21.4 23.4 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP95-9 Grundfos MMS6000 37 80.0 / 79.0 400 / 415 88 26-37 13 26.4 34 158 109 189 1852.2 178.0 144.0 3.233 1.425 Yes Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 13 14 32 34 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Pleuger PN83-5 Pleuger M8-530-2 37 74 400 88 26-37 11.3 22.5 27 120 102 141 1381.8 197.0 186.0 2.008 1.238 No Same as motor rated current 65 alarm / 70 trip TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 11.3 12.3 25 27 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Pleuger PN84-5 Pleuger M8-530-2 37 73 400 88 45-63 15 30 36 108 87 131.5 1288.7 197.0 186.0 2.008 1.238 No Same as motor rated current 65 alarm / 70 trip TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 15 17 34 36 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Lowara ZR895 6/3A-L8WR Lowara L8WR550T405 HT 37 110 415 88 45-63 6 23.5 37 147 125 150 1470 204.8 192.0 2.622 1.200 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 6 7 35 37 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP125-5A Grundfos MMS8000 45 96.5 / 96.0 400 / 415 110 45-63 17 34.7 44 128 96 136 1332.8 213.0 192.0 2.545 1.270 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 17 19 42 44 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP125-5AA Grundfos MMS8000 45 96.5 / 96.0 400 / 415 110 45-63 17 34.7 44 119 87 127 1244.6 213.0 192.0 2.545 1.270 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 17 19 42 44 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP125-5A SEMA 45kW 45 80.3 415 110 45-63 17 34.7 44 128 96 136 1332.8 213.0 191.0 2.625 1.350 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 17 19 42 44 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP125-5AA SEMA 45kW 45 80.3 415 110 45-63 17 34.7 44 119 87 127 1244.6 213.0 191.0 2.625 1.350 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 17 19 42 44 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP95-9 SEMA 45kW 45 80.3 415 110 45-63 13 26.4 34 158 109 189 1852.2 178.0 191.0 3.158 1.350 Yes Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 13 14 32 34 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Pleuger PN83-6 Pleuger M8-650-2 48 93 400 110 45-63 11.3 22.5 27 147 122 169.2 1658.16 214.0 186.0 2.243 1.358 Yes Same as motor rated current 65 alarm / 70 trip TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 11.3 12.3 25 27 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Pleuger PN84-6 Pleuger M8-650-2 48 93 400 110 45-63 15 30 36 127 106 158 1548.4 214.0 186.0 2.243 1.358 Yes Same as motor rated current 65 alarm / 70 trip TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 15 17 34 36 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Pleuger PN84-7a Pleuger M8-650-2 50 97 400 110 45-63 15 30 36 140 120 174 1705.2 214.0 186.0 2.358 1.358 Yes Same as motor rated current 65 alarm / 70 trip TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 15 17 34 36 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Pleuger PN102-3a Pleuger M8-710-2 54 106 400 165 45-63 19.44 38.9 46.7 118 85 147 1440.6 257.0 186.0 2.128 1.418 No Same as motor rated current 65 alarm / 70 trip TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 19.5 21.5 44.7 46.7 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Pleuger QN81-8 Pleuger M8-710-2 54 106 400 165 45-63 16 32 38.4 138 97 216 2116.8 214.0 186.0 2.612 1.418 Yes Same as motor rated current 65 alarm / 70 trip TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 16 18 36.4 38.4 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP125-5 Grundfos MMS8000 55 114.0 / 112.0 400 / 415 165 45-63 17 34.7 44 137 102 146 1430.8 213.0 192.0 2.625 1.350 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 17 19 42 44 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP160-5A Grundfos MMS8000 55 114.0 / 112.0 400 / 415 165 45-63 22 44.4 57 130 95 151 1479.8 218.0 192.0 2.625 1.350 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 22 24 55 57 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP160-5AA Grundfos MMS8000 55 114.0 / 112.0 400 / 415 165 45-63 22 44.4 57 123 88 141 1381.8 218.0 192.0 2.625 1.350 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 22 24 55 57 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP125-5 SEMA 55kW 55 105.7 415 165 45-63 17 34.7 44 137 102 146 1430.8 213.0 191.0 2.755 1.480 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 17 19 42 44 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP160-5A SEMA 55kW 55 105.7 415 165 45-63 22 44.4 57 130 95 151 1479.8 218.0 191.0 2.755 1.480 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 22 24 55 57 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP160-5AA SEMA 55kW 55 105.7 415 165 45-63 22 44.4 57 123 88 141 1381.8 218.0 191.0 2.755 1.480 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 22 24 55 57 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP160-5 Grundfos MMS8000 63 132.0 / 130.0 400 / 415 165 45-63 22 44.4 57 140 102 160 1568 218.0 192.0 2.765 1.490 Yes Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 22 24 55 57 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Pleuger PN104-3A Pleuger M8-710-2 66 127 400 165 75-92 23.75 47.5 57 117 86 149.2 1462.16 257.0 186.0 2.128 1.418 No Same as motor rated current 65 alarm / 70 trip TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 23.8 25.8 55 57 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Pleuger PN104-3 Pleuger M8-820-2 70 135 400 220 75-92 24.2 48.4 58.1 125 90 127 1244.6 252.0 186.0 2.238 1.528 No Same as motor rated current 65 alarm / 70 trip TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 24.2 26.2 56.1 58.1 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Pleuger QN83-8 Pleuger M8-820-2 70 134 400 220 75-92 20.9 41.8 50.2 239 108 212 2077.6 207.0 186.0 2.722 1.528 Yes Same as motor rated current 65 alarm / 70 trip TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 20.9 22.9 48.2 50.2 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP160-6A Grundfos MMS8000 75 152.0 / 152.0 400 / 415 220 75-92 22 44.4 57 157 117 182 1783.6 218.0 192.0 3.021 1.590 Yes Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 22 24 55 57 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP215-4AA Grundfos MMS8000 75 152.0 / 152.0 400 / 415 220 75-92 31 59.7 75 117 85 134 1313.2 241.0 192.0 2.908 1.590 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 31 33 73 75 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP160-5 SEMA 75kW 75 137.8 415 220 75-92 22 44.4 57 140 102 160 1568 218.0 191.0 2.955 1.680 Yes Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 22 24 55 57 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP160-6A SEMA 75kW 75 137.8 415 220 75-92 22 44.4 57 157 117 182 1783.6 218.0 191.0 3.111 1.680 Yes Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 22 24 55 57 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP215-4AA SEMA 75kW 75 137.8 415 220 75-92 31 59.7 75 117 85 134 1313.2 241.0 191.0 2.998 1.680 No Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 31 33 73 75 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Pleuger PN104-4A Pleuger M8-990-2 90 171 400 220 75-92 23.75 47.5 57 158 118 202.7 1986.46 252.0 186.0 2.563 1.698 Yes Same as motor rated current 65 alarm / 70 trip TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 23.8 25.8 55 57 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP215-5AA Grundfos MMS8000 92 186.0 / 186.0 400 / 415 220 75-92 31 59.7 75 158 110 173 1695.4 241.0 192.0 3.324 1.830 Yes Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 31 33 73 75 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Grundfos SP215-5AA SEMA 93kW 93 190.9 415 220 75-110 31 59.7 75 158 110 173 1695.4 241.0 191.0 3.174 1.680 Yes Same as motor rated current TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 31 33 73 75 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.
Pleuger QN101-5A Pleuger MH8-990-2 98 188 400 250 75-110 33.4 66.7 80 129 102 180 1764 255.0 186.0 2.718 1.698 Yes Same as motor rated current 65 alarm / 70 trip TBA by Engineer / Refer to install sheet Leave as current. If new t TBA by Engineer / Refer to install sheet 33.4 35.4 78 80 Leave as current. If Leave as current unless advised by Engineer. If new low speed pump trip at 25Hz for Pleuger, 30Hz for Lowara. Low speed alarm and soft control limit at 28Hz for Pleguer and 32Hz for Lowara. High speed alarm and soft control limit at 50Hz for all.

Total no. of models 64


>1400 kPa 36

525817565.xlsx
Pleuger Model Grundfos Equivalent
Model Lowara models
NB65-10 +M6-240-2 SP17-11
NB65-11 + M6 -270-2 SP17-14
NB84-6+M6-400-2 SP30
NB84-7+M6-460-2
QT8ELL-4a+M6-460-2 SP46
QT8ELL-5a+M6-460-2
PN81-6a+ M6-650-2 SP60 ZR855 5-L6W
PN81-7a + M6 -720-2
PN82-6a+M6-720-2 SP77
PN83-5 +M8-530-2
PN83-6a + M8-650-2
PN84-5+ M8-530-2 SP95-7
PN84-6+ M8-650-2 SP95-9 ZR895 6/3A-L8WR
PN84-7a+M8-650-2
QN81-8-M8-710-2 SP125
PN102-3a+M8-710-2
QN83-8+M8-820-2 SP160-7
PN104-3a + M8 -710-2 SP160-4
PN104-3a + M8 -820-2
PN104-4a + M8-990-2 SP215-5
QN101-5a + MH8-990-2
Operating ran
Rated Rated
FMG Pleugers Rated Duty FMG Pleugers Power Amps MCSF BEP

Line Materials Motor Line Materials


no. Pump Size (casing/imp/shroud) kW m³/hr l/s m no. Pump Type (casing/imp/shroud) kW A l/s m³/hr l/s m³/hr

1 NB65-10 + M6-240-2 Bz/Nrl/SS 7.5 16.3 4.5 95 1 NB65-10+M6-240-2 Bz/Nrl/SS 7.5 16.8 1.8 6.5 4.5 16.3

2 NB65-11 + M6 -270-2 SDX/SDX/SDX 11 16.2 4.5 105 2 NB65-11+M6-270-2 SDX/SDX/SDX 11 24 1.8 6.5 4.5 16.2

3 NB84-6+M6-400-2 SDX/SDX/SDX 15 22.2 6.2 100 3 NB84-6+M6-400-2 SDX/SDX/SDX 15 32 2.8 9.9 6.9 24.8

4 NB84-7+M6-400-2 Bz/Nrl/SS 15 24.2 6.7 115 4 NB84-7+M6-400-2 Bz/Nrl/SS 15 32 2.7 9.7 6.7 24.2

5 NB84-7+M6-460-2 SDX/SDX/SDX 18.5 26.4 7.3 105 5 NB84-7+M6-460-2 SDX/SDX/SDX 18.5 39 2.7 9.9 6.9 24.7

6 NB87-6+M6-720-2 Bz/Nrl/SS 31 60.2 16.7 102 6 NB87-6+M6-720-2 Bz/Nrl/SS 31 65 6.7 24.0 16.7 60.1

7 PN81-6a+ M6-650-2 SDX/SDX/SDX 24.5 44.0 12.2 100 7 PN81-6a+M6-650-2 SDX/SDX/SDX 24.5 53 6.4 23.0 16.0 57.6

8 PN81-7a + M6 -720-2 SDX/SDX/SDX 31 44.0 12.2 115 8 PN81-7a+M6-720-2 SDX/SDX/SDX 31 65 6.2 22.2 15.4 55.4

9 PN82-6a+M6-720-2 SDX/SDX/SDX 31 76.0 21.1 97 9 PN82-6a+M6-720-2 SDX/SDX/SDX 31 65 7.8 28.1 19.5 70.2

10 PN83-5 +M8-530-2 SDX/SDX/SDX 37 104.0 28.9 83 10 PN83-5+M8-530-2 SDX/SDX/SDX 37 74 8.9 32.1 22.3 80.3

11 PN83-6a + M8-650-2 SDX/SDX/SDX 48 89.5 24.9 116 11 PN83-6a+M8-650-2 SDX/SDX/SDX 48 93 9.0 32.4 22.5 81.0

12 PN84-5+ M8-530-2 SDX/SDX/SDX 37 116.9 32.5 80 12 PN84-5+ M8-530-2 SDX/SDX/SDX 37 73 11.8 42.6 29.6 106.6

13 PN84-6+ M8-650-2 SDX/SDX/SDX 48 101.0 28.1 110 13 PN84-6+M8-650-2 SDX/SDX/SDX 48 93 11.8 42.6 29.6 106.6

14 PN84-7a+M8-650-2 SDX/SDX/SDX 50 100.0 27.8 120 14 PN84-7a+M8-650-2 SDX/SDX/SDX 50 97 11.1 40.0 27.8 100.1

15 PN102-3a+M8-710-2 SDX/SDX/SDX 54 130.0 36.1 90 15 PN102-3a+M8-710-2 SDX/SDX/SDX 54 106 14.4 51.8 36.0 129.6

16 PN104-3a + M8 -710-2 SDX/SDX/SDX 66 160.0 44.4 90 16 PN104-3a+M8-710-2 SDX/SDX/SDX 66 127 19.0 68.4 47.5 171.0

17 PN104-3a + M8 -820-2 SDX/SDX/SDX 70 180.0 50.0 90 17 PN104-3a + M8 -820-2 SDX/SDX/SDX 66 127 19.4 69.7 48.4 174.2

18 PN104-4a + M8-990-2 SDX/SDX/SDX 90 160.0 44.4 123 18 PN104-4a+M8-990-2 SDX/SDX/SDX 90 171 18.3 66.0 45.8 164.9

19 QN81-8-M8-710-2 SDX/SDX/SDX 54 130.5 36.2 90 19 QN81-8+M8-710-2 SDX/SDX/SDX 54 106 12.8 46.1 32.0 115.2

525817565.xlsx Page 3 of 12 05/28/2021


20 QN83-8+M8-820-2 SDX/SDX/SDX 70 179.5 49.9 85 20 QN83-8+M8-820-2 SDX/SDX/SDX 70 134 16.7 60.2 41.8 150.5

21 QT8ELL-4a+M6-460-2 SDX/SDX/SDX 17.5 43.2 12.0 85 21 QT8ELL-4a+M6-460-2 SDX/SDX/SDX 17.5 38.5 4.9 17.7 12.3 44.3

22 QT8ELL-5a+M6-460-2 SDX/SDX/SDX 22.5 43.2 12.0 102 22 QT8ELL-5a+M6-460-2 SDX/SDX/SDX 22.5 49 4.8 17.4 12.1 43.6

23 QN101-5a + MH8-990-2 SDX/SDX/SDX 98 220.0 61.1 108 23 QN101-5a+MH8-990-2 SDX/SDX/SDX 98 188 26.7 96.0 66.7 240.1

525817565.xlsx Page 4 of 12 05/28/2021


Operating range Cable Starting information
Sizing FMG Pleugers Shroud
50% 120% Extended Max.
Motor Cable Original cable Cable Maximum Sequential Maximum
ordered
Motor Pump Ramp-up
l/s m³/hr l/s m³/hr NRV dia dia Pump Size Size Material size Length starts/hr Starts
time

2.3 8.1 5.4 19.5 G3 144 147 NB65-10+M6-240-2 156 x 1219 SMO FL4 x 2.5mm² 4 x 4mm² 95 + 7m 8 3 5 sec

2.3 8.1 5.4 19.4 G3 144 147 NB65-11+M6-270-2 165 x 1395 SMO FL4 x 4mm² 4 x 6mm² 95 + 7m 8 3 5 sec

3.5 12.4 8.3 29.8 G4 144 147 NB84-6+M6-400-2 210 x 1800 SMO FL4 x 6mm² 4 x 10mm² 95 + 7m 8 3 5 sec

3.4 12.1 8.1 29.0 G4 144 192 NB84-7+M6-400-2 200 x 1467 SMO FL4 x 6mm² 4 x 10mm² 95 + 7m 8 3 5 sec

3.4 12.3 8.2 29.6 G4 144 192 NB84-7+M6-460-2 210 x 1920 SMO FL4 x 6mm² 4 x 10mm² 95 + 7m 8 3 5 sec

8.4 30.1 20.0 72.1 G4 144 192 NB87-6+M6-720-2 200 x 1838 SMO FL4 x 10mm² 4 x 25mm² 95 + 7m 8 3 5 sec

8.0 28.8 19.2 69.1 G4 144 188 PN81-6a+M6-650-2 200 x 1300 SDX / SMO FL4 x 10mm² 4 x 16mm² 95 + 7m 8 3 5 sec

7.7 27.7 18.5 66.5 G4 144 188 PN81-7a+M6-720-2 215 x 1330 SMO FL4 x 10mm² 4 x 16mm² 95 + 7m 8 3 5 sec

9.8 35.1 23.4 84.2 G4 144 188 PN82-6a+M6-720-2 200 x 1330 SMO FL4 x 10mm² 4 x 16mm² 95 + 7m 8 3 5 sec

11.2 40.1 26.8 96.3 G4 186 197 PN83-5+M8-530-2 240 x 1430 SMO FL4 x 25mm² 4 x 25mm² 95 + 7m 8 3 5 sec

11.3 40.5 27.0 97.2 G5 186 214 PN83-6a+M8-650-2 225 x 1600 SDX P 4 x1 x 25mm² 4 x 35mm² 95 + 7m 8 3 5 sec

14.8 53.3 35.5 127.9 G4 186 214 PN84-5+ M8-530-2 240 x1430 SMO P 4 x1 x 25mm² 4 x 25mm² 95 + 7m 8 3 5 sec

14.8 53.3 35.5 127.9 G4 186 214 PN84-6+M8-650-2 240 x 1500 SMO P 4 x1 x 25mm² 4 x 35mm² 95 + 7m 8 3 5 sec

13.9 50.0 33.4 120.1 G4 186 214 PN84-7a+M8-650-2 240 x 1500 SMO P 4 x1 x 25mm² 4 x 35mm² 95 + 7m 8 3 5 sec

18.0 64.8 43.2 155.5 G6 186 257 PN102-3a+M8-710-2 250 x 1650 SMO P 4 x1 x 25mm² 4 x 35mm² 95 + 7m 8 3 5 sec

23.8 85.5 57.0 205.2 G6 186 257 PN104-3a+M8-710-2 250 x 1700 SDX / SMO P 4 x1 x 25mm² 4 x 35mm² 95 + 7m 8 3 5 sec

24.2 87.1 58.1 209.1 G6 186 257 PN104-3a + M8 -820-2 265 x 1800 SMO P 4 x1 x 25mm² 4 x 50mm² 95 + 7m 8 3 5 sec

22.9 82.4 55.0 197.9 G6 186 252 PN104-4a+M8-990-2 250 x 2000 SDX P 4 x1 x 25mm² 4 x 50mm²105+7m, 95 + 7m 8 3 5 sec

16.0 57.6 38.4 138.2 G5 186 214 QN81-8+M8-710-2 200 x 1300 SMO / SDX P 4 x1 x 25mm² 4 x 16mm² 95 + 7m 8 3 5 sec

525817565.xlsx Page 5 of 12 05/28/2021


20.9 75.2 50.2 180.6 G5 186 207 QN83-8+M8-820-2 265 x 1700 SMO P 4 x1 x 25mm² 4 x 50mm² 95 + 7m 8 3 5 sec

6.2 22.1 14.8 53.1 G4 144 210 QT8ELL-4a+M6-460-2 230 x 1120 SMO FL4 x 6mm² 4 x 10mm² 95 + 7m 8 3 5 sec

6.1 21.8 14.5 52.3 G4 144 210 QT8ELL-5a+M6-460-2 230 x 1400 SMO FL4 x 6mm² 4 x 16mm² 95 + 7m 8 3 5 sec

33.4 120.1 80.0 288.1 R8 186 255 QN101-5a+MH8-990-2 260 x 2150 SDX / SMO P 3/4 x1 x 16mm² 4x50 + 3x50 95 + 7m 8 3 5 sec

525817565.xlsx Page 6 of 12 05/28/2021


Starting information PT 100 RTD Notes

Overall weight inc.


Minimum start-up Warning Cutoff shroud and cables

Voltage °C °C Kg

55% of rated voltage 60 65 93

55% of rated voltage 60 65 121

55% of rated voltage 60 65 194

55% of rated voltage 60 65 233

55% of rated voltage 60 65 233

55% of rated voltage 60 65 262

55% of rated voltage 60 65 218

55% of rated voltage 60 65 236

55% of rated voltage 60 65 226

55% of rated voltage 60 65 277

55% of rated voltage 60 65 321

55% of rated voltage 60 65 277

55% of rated voltage 60 65 311

55% of rated voltage 60 65 320

55% of rated voltage 60 65 352

55% of rated voltage 60 65 351

55% of rated voltage 60 65 370

55% of rated voltage 60 65 428

55% of rated voltage 60 65 348

525817565.xlsx Page 7 of 12 05/28/2021


55% of rated voltage 60 65 365

55% of rated voltage 60 65 193

55% of rated voltage 60 65 223

55% of rated voltage 60 65 464

525817565.xlsx Page 8 of 12 05/28/2021


Maker Model Min Flow BEP FLow Lps Max Flow Head Min Flow BEP Head m
Grundfos SP17-11 2.35 4.7 6 118 90
Grundfos SP17-14R 2.35 4.7 6 151 113
Grundfos SP30-10 3.6 8.3 10.8 104 77
Grundfos SP30-11 3.6 8.3 10.8 112 85
Grundfos SP30-8 3.6 8.3 10.8 84 61
Grundfos SP30-9 3.6 8.3 10.8 95 69
Grundfos SP46-10 6.4 12.8 16.8 117 87
Grundfos SP46-11 6.4 12.8 16.8 130 97
Grundfos SP46-12R 6.4 12.8 16.8 141 105
Grundfos SP46-8N 6.4 12.8 16.8 94 69
Grundfos SP46-9 6.4 12.8 16.8 106 78
Grundfos SP60-10 8 16.7 20 121 79
Grundfos SP60-12 8 16.7 20 145 95
Grundfos SP77-11N 10.4 21.4 27 190 135
Grundfos SP77-7 10.4 21.4 27 121 86
Grundfos SP77-9R 10.4 21.4 27 155 111
Grundfos SP95-7 13 26.4 34 123 85
Grundfos SP95-9 13 26.4 34 158 109
Grundfos SP125-5 17 34.7 44 137 102
Grundfos SP125-5AA 17 34.7 44 119 87
Grundfos SP160-5A 22 44.4 57 130 95
Grundfos SP160-5AA 22 44.4 57 123 88
Grundfos SP160-6 22 44.4 57 165 124
Grundfos SP160-6AAN 22 44.4 57 150 110
Grundfos SP160-6AN 22 44.4 57 157 117
Grundfos SP215-4AAR 31 59.7 75 117 85
Grundfos SP215-5AA 31 59.7 75 158 110
Grundfos SP215-5N 31 59.7 75 164 123
Pleuger NB65-10+M6-240-2 2.3 4.5 5.4 116 95
Pleuger NB65-11+M6-270-2 2.3 4.5 5.4 124 105
Pleuger NB84-7+M6-460-2 3.4 6.7 8.1 130 111
Pleuger NB84-6+M6-400-2 3.5 6.9 8.3 112 94
Pleuger QT8ELL-4A+M6-460-2 6 12 16.5 100 85
Pleuger QT8ELL-5A+M6-600-2 6 12 16.5 121 102
Pleuger NB87-6+M6-720-2 8.4 16.7 20 132 102
Pleuger PN81-6A +M6-650-2 8.47 15.4 17.7 115 90
Pleuger PN81-7a+M6-720-2 8.47 15.4 17.71 134 105
Pleuger PN82-6+M6-720-2 9.75 19.5 23.4 126 102
Pleuger PN83-5+M8-530-2 11.3 22.5 27 120 102
Pleuger PN83-6 +M8-650-2 11.3 22.5 27 147 122
Pleuger PN84-5+M8-530-2 15 30 36 108 87
Pleuger PN84-6+M8-650-2 15 30 36 127 106
Pleuger PN84-7a+M8-650-2 15 30 36 140 120
Pleuger QN81-8+M8-710-2 16 32 38.4 138 97
Pleuger PN102-3a+M8-710-2 19.44 38.9 46.7 118 85
Pleuger QN83-8+M8-820-2 20.9 41.8 50.2 239 108
Pleuger PN104-3a +M8-710-2 23.75 47.5 57 117 86
Pleuger PN104-4a+M8-990-2 23.75 47.5 57 158 118
Pleuger QN101-5a+MH8-990-2 33.4 66.7 80 129 102
Shut off Head M
124
157
114
125
91
103
135
149
162
108
122
143
172
218
140
178
148
189
146
127
151
141
191
173
182
134
173
195
126
140
136
115.8
108
131
161
143.1
164
155
141
169.2
131.5
158
174
216
147
212
149.2
202.7
180