SCOPE
This Safe Work Instruction shall relate to all Mine personnel who are required to remove a bore
pump in a consistent and safe manner. A copy of this information is to be printed off and
available at the job site at all times during the undertaking of this task. Personnel shall comply
with Fortescues Life Saving Choices. This Safe Work Instruction supersedes all previous Safe
Work Instructions and Site Notices.
AREA
All Areas Christmas Creek Mine Site
REQUIREMENTS
LIFE SAVING CHOICES
The twelve choices define the standards that shall be met in our workplace to ensure safe
systems of work, and to guide you in making the correct decisions. The choices you make, every
single day, are fundamental to creating a safe operation. The non-negotiable choices are:
LIFE SAVING CHOICES
Secure tools and barricade work areas to prevent dropped
Use fall protection when working at height – 2x2.
objects.
When driving wear a seat belt and obey speed Obtain authorisation prior to entering confined space.
limits.
This document is UNCONTROLLED in hard copy unless stamped and specified and managed in controlled document register
Rev Description of Rev/Comments: Prepared by Reviewed By Approved By Review Date Issue Date Page
9 Issued for Use 29/06/2019 30/06/2019 1 of
Chris Mill George Konidaris Willie Weismantel
11
REMOVAL OF BORE PUMP ON PERMAGLASS COLUMN
CC-00018-WI-OP-0013_Rev 9
Department Document Number
CC WATER MANAGEMENT CC-00018-WI-OP-0013_Rev 9
Section Title
SAFE WORK INSTRUCTION Removal of Bore Pump on Permaglass / FRP riser
DESCRIPTION OF WORK
The core of the Dewatering Operations across Christmas Creek is the system of bore pumps, which
lower the local water table to a level close to, or below the level of the bottom of the open pit operations.
The water taken out of the ground is piped to a location further from the active mining area and then re-
injected back into the ground. The amount of water pumped from underground must comply with
dewatering legislation, licensing and FMG standards. This requires that the pumps be installed and
removed correctly. This procedure outlines the steps required to remove bore pumps consistently, while
maintaining a high level of safety.
with the pump can pose a cables that could cause a trip
trip hazard. hazard.
Using the incorrect tool for Use correct size tooling and
the job is a known cause maintain control to prevent
of personal injury. slipping
This document is UNCONTROLLED in hard copy unless stamped and specified and managed in controlled document register
Rev Description of Rev/Comments: Prepared by Reviewed By Approved By Review Date Issue Date Page
9 Issued for Use 29/06/2019 30/06/2019 4 of
Chris Mill George Konidaris Willie Weismantel
11
REMOVAL OF BORE PUMP ON PERMAGLASS COLUMN
CC-00018-WI-OP-0013_Rev 9
Department Document Number
CC WATER MANAGEMENT CC-00018-WI-OP-0013_Rev 9
Section Title
SAFE WORK INSTRUCTION Removal of Bore Pump on Permaglass / FRP riser
This document is UNCONTROLLED in hard copy unless stamped and specified and managed in controlled document register
Rev Description of Rev/Comments: Prepared by Reviewed By Approved By Review Date Issue Date Page
9 Issued for Use 29/06/2019 30/06/2019 5 of
Chris Mill George Konidaris Willie Weismantel
11
REMOVAL OF BORE PUMP ON PERMAGLASS COLUMN
CC-00018-WI-OP-0013_Rev 9
Department Document Number
CC WATER MANAGEMENT CC-00018-WI-OP-0013_Rev 9
Section Title
SAFE WORK INSTRUCTION Removal of Bore Pump on Permaglass / FRP riser
Ergonomics of work
area and height of
casing Magic frame is available
to raise working height
and assist with manual
Cables and conduits handling
can become a trip
hazard if not attended Operators to maintain a
when removing bore clean, clear work area
components. and make sure all cables
are clear of works.
Visual/verbal
communications are Be sure at least one
imperative to the safe operator on the ground
operation of overhead has a handheld radio to
lifting equipment. maintain contact with
crane operator. Maintain
line of sight with crane
operator and use clear
Crush/pinch points hand signals.
exist during steps to
bore head plate Never put yourself under
removal. a suspended load.
Always wear PPE and
use the correct tools for
The Slip Plate is the the job.
only defence against
equipment dropping Place the Slip Plate over
down the bore hole. the bore head and guide
the crane operator to
lower the clamp gently on
to the slip plate keeping
A sharp blade is yourself out of the line of
necessary to remove fire.
the tape at FRP joins
and conduit. Always wear gloves and
retain full control of
cutting implement.
Removal of stainless
steel locking wire
requires use of pliers Remove cable by
and may be hard to applying a steady pull
remove. Sprains, pressure to pliers. Do not
strains, stored energy tug or overexert. Have the
present. crane operator try
relieving pressure on
cable by slightly lifting or
lowering FRP. Use plier
This document is UNCONTROLLED in hard copy unless stamped and specified and managed in controlled document register
Rev Description of Rev/Comments: Prepared by Reviewed By Approved By Review Date Issue Date Page
9 Issued for Use 29/06/2019 30/06/2019 6 of
Chris Mill George Konidaris Willie Weismantel
11
REMOVAL OF BORE PUMP ON PERMAGLASS COLUMN
CC-00018-WI-OP-0013_Rev 9
Department Document Number
CC WATER MANAGEMENT CC-00018-WI-OP-0013_Rev 9
Section Title
SAFE WORK INSTRUCTION Removal of Bore Pump on Permaglass / FRP riser
5 Clamp the FRP and use the Slip Plate to support it within
the bore hole, remove second column and place on flat
ground (or stack) out of work area.
This document is UNCONTROLLED in hard copy unless stamped and specified and managed in controlled document register
Rev Description of Rev/Comments: Prepared by Reviewed By Approved By Review Date Issue Date Page
9 Issued for Use 29/06/2019 30/06/2019 8 of
Chris Mill George Konidaris Willie Weismantel
11
REMOVAL OF BORE PUMP ON PERMAGLASS COLUMN
CC-00018-WI-OP-0013_Rev 9
Department Document Number
CC WATER MANAGEMENT CC-00018-WI-OP-0013_Rev 9
Section Title
SAFE WORK INSTRUCTION Removal of Bore Pump on Permaglass / FRP riser
Use correct
lifting/handling techniques
if removing FRP adaptor
to retrieve break off pin.
10 House Keeping
This document is UNCONTROLLED in hard copy unless stamped and specified and managed in controlled document register
Rev Description of Rev/Comments: Prepared by Reviewed By Approved By Review Date Issue Date Page
9 Issued for Use 29/06/2019 30/06/2019 9 of
Chris Mill George Konidaris Willie Weismantel
11
REMOVAL OF BORE PUMP ON PERMAGLASS COLUMN
CC-00018-WI-OP-0013_Rev 9
Department Document Number
CC WATER MANAGEMENT CC-00018-WI-OP-0013_Rev 9
Section Title
SAFE WORK INSTRUCTION Removal of Bore Pump on Permaglass / FRP riser
Communicate to your
supervisor that the task has
been completed (if required).
11 Hazard Reporting
Hazard reporting is If any hazard/s are identified
essential to maintaining a during this task either remove
safe workplace; operators the hazard/s or isolate the
shall follow these simple Hazard/s.
instructions to complete the
given task. DO NOT put yourself or
others in danger.
This document is UNCONTROLLED in hard copy unless stamped and specified and managed in controlled document register
Rev Description of Rev/Comments: Prepared by Reviewed By Approved By Review Date Issue Date Page
9 Issued for Use 29/06/2019 30/06/2019 10 of
Chris Mill George Konidaris Willie Weismantel
11
REMOVAL OF BORE PUMP ON PERMAGLASS COLUMN
CC-00018-WI-OP-0013_Rev 9
Department Document Number
CC WATER MANAGEMENT CC-00018-WI-OP-0013_Rev 9
Section Title
SAFE WORK INSTRUCTION Removal of Bore Pump on Permaglass / FRP riser
I have received, read, understood and shall comply with this Safe Work Instruction for Removal of
Bore Pump.
Signature: Crew/Pit:
Company: Department:
This document is UNCONTROLLED in hard copy unless stamped and specified and managed in controlled document register
Rev Description of Rev/Comments: Prepared by Reviewed By Approved By Review Date Issue Date Page
9 Issued for Use 29/06/2019 30/06/2019 11 of
Chris Mill George Konidaris Willie Weismantel
11
REMOVAL OF BORE PUMP ON PERMAGLASS COLUMN
CC-00018-WI-OP-0013_Rev 9