You are on page 1of 12

CHEMISTRY 321/323 EXAM 4 December 14,2007

1. There twenty (20) multiple-choice questions. Code answers for the multiple­
choice questions on the scan sheet.
2. Write your name and student 10 number on the answer sheet.
3. Write your Graduate Instructor's name on the line for "Instructor" on the
answer sheet.
4. Use a #2 HB pencil to code all information onto the answer sheet.
5. Code your name and student 10 number on the answer sheet.
6. Code 0321 or 0323 as the "Section Number" on the answer sheet.
7. Code the best answer to each question on the answer sheet.
8. Relevant equations are listed at the end of the exam.
9. Each multiple-choice question is worth ten (10) points. The total score for this
exam is two hundred (200) points.

CONFIRM THAT YOUR EXAM INCLUDES ALL TWENTY (20) QUESTIONS


1. Which of the following measurements involves electrolysis:

a) The measurement of pH with a pH electrode


b) A redox titration using a redox indicator
@ A stripping analysis of uranium in water
d) A titration in which the analyte solution potential is measured as a
function of added titrant relative to the standard hydrogen electode.
e) All of the above.

2. Which of the following electrochemical methods requires the formation of


an insoluble form of the analyte?

@ electrogravimetry

b) coulometry

c) potentiometry

d) voltammetry

e) polarography

3. Which of the following phenomena is not a factor that affects polarization


at an electrode?

a) diffusion of the analyte to the electrode surface

b) diffusion of the product from the electrode surface

c) convection

<ill) the standard cell potential for the redox couple

e) a significant activation barrier for the reaction

4. The limiting current in a linear sweep voltammogram is related to:

a) The standard reduction potential for the redox couple under


investigation
b) The reduction potential of the reference electrode

~
The point at which concentration polarization begins
The concentration of the analyte of interest
e) The reduction potential of water
5. A potential of -0.788 V was applied to a cell with a cell potential of -0.734
V. The internal resistance of the cell was 18.0 0 and an initial current of
1.78 mA was measured. What value can be assigned to an overpotential
for this cell?

a) There is no overpotential associated with this cell.


b) An overpotential cannot be determined from the information

c)
6~~~~~d. ~f?ll cJ ~ ~c-e.\l -:t R - TI
em> 0.022 V
0.054 V
1T ::: ~
c...e
II 1""' f"'\ t2'
- ...... "- - 'Z-4.., P \~O\
I I

e)
6.024 :: -_1-3Lf - (0.0011'6)(13"') - [-.l-'?:'f)
6. Which of the following forms of electrochemistry seeks to obtain the
condition of full polarization?

a) potentiometry
@:> voltammetry

c) coulometry

d) electrogravimetry

e) ohmetry

7. In the coulometric titration of U4+ in the presence of excess Ce 3+, it was


found to require 652 seconds to reach the equivalence point using a
constant current of 100.0 mA. How many moles of U4 + were present in the
solution?

~ .:roC (~ . \ 0 0) (" S-2.)


a) 6.76 X 10-4 moles
r1 A = --.=;-;: -t ' \ F ­­
®
c)
3.38 x 10-4 moles
1.35 x 10-3 moles

V\r
c.z.) (Cib )'1trS-)
d) 1.69 x 10-4 moles

e) none of the above

8. Which of the following properties is not used as a basis for physical


separation of analyte species in analytical chemistry?

a) mass
b) polarity
@ molar absorptivity

d) physical state

e) size

9. What is the main difference between HPLC and UPLC?

a) HPLC is reverse-phase whereas UPLC is normal-phase


® UPLC employs smaller stationary-phase particle size

c) HPLC and UPLC employ different mobile phases

d) HPLC and UPLC employ different detection methods

e) HPLC operates at higher mobile phase pressures

10. Which of the following statements is accurate?

a) Capillary column GC generally has higher efficiencies than HPLC


because of a lower plate height in GC
b) HPLC has higher efficiencies than capillary column GC because
the column length is longer
c) Gradient elution is an important approach in capillary GC to deal
with the general elution problem
Capillary column GC generally has higher efficiencies than HPLC
because of a much greater column length in GC
e) Mobile phase composition is an important experimental variable in
both GC and LC

11. A good reason to increase flow rate in chromatography is

a) to minimize band broadening due to mobile phase mass transport.


b) to minimize band broadening due to mass transport in the
stationary phase.

c) to minimize eddy diffusion.

d) to minimize column bleed.

@ to minimize band broadening due to longitudinal diffusion.


Use the following information as needed for questions 12 and 13:

A weak organic acid has a Ka value of 6.2x1 0-5 M- 1 . The distribution constant,
Ko , for this acid between an organic solvent and water is 5.2.

12. If the aqueous phase is buffered to a pH of 4.61, what will the distribution
ratio, 0, be for this acid between water and the organic phase?
~a Cl'+~J ~ 10- 4 ."\:: ).·4 b J( 10-)" C/f-+)
\...£J./ 1.47 K
b) 2.41 Q= T:) • 0
c) 3.72 ( H + \'(~
d) 5.21 _ 2. 46{(O-S • Cr:"l..)
e) No response is correct. - l.ll. f> ~ 10' r + (;_ 2.)( \o~ r

.= (. Y-=1­
13. An increase in the pH of the aqueous phase would be expected to:

a) decrease the fraction of the acid in the aqueous phase.

b) have no effect on either Ko or O.

c) decrease the analytical concentration in the aqueous phase but

have no effect on the actual concentration.

@ increase the fraction of the acid in the aqueous phase.

e) have no effect on the acid concentration in either phase.

Use the following information as needed for questions 14 and 15:

The distribution constant, Ko, for b between chloroform and water is 87.

14. What fraction of 12 initially present in 50 mL of water is expected to


partition into the organic phase after a single extraction with 50 mL of
chloroform?

a) 0.01
b) 0.03
c) 0.50
@ 0.99
e) 0.97
l~1-) ()O)
-
("0 + f7-{ ro)

::. (9.99
15. What aqueous concentration of r should be used to remove roughly 99%
of the 12 initially present in 50 mL of chloroform using 5 extractions with 50
mL volumes of water? .s+('~ \ . . Drlef'-oNltJ'\.€ \) ..,..,~ .. ;) 0,)
J ...
( v~ 0
S

~
..s,.~ p ?. - Pe~/'"''-~ C. 4- .~;-,
a) 0.174M ----. - V.
) 0.075 M \05 (0 .C \)::: 10 ~o _ - - cr~l",.o ~ T D" D
I/.

c) 0.288 M ~- lj ~ '+-~O <!.


d) 11.48 M \C"'o.l{( ro t-SDtl) .:ore 0-:: ~ ::: l.rl-= ~
e) None of the above. ","'J I t-\(~l:r ') 11"1$1> [::rj
D:=/.5"") _.­
(;r -J ~ ~. Irlf !1
USE THE FOLLOWING INFORMATION TO ANSWER QUESTIONS 16 THRU
20

Table 1. Peak positions, heights, and widths for four components separated
isocratically using a 10 cm reverse phase column and a flow rate of 0.2 cm/s.
Detection was via UV-vis absorption.

Non-
Quantity retained Analyte A Analyte B Analyte C Analyte D
species
Peak height (au) 0.1 2.30 0.22 0.52 1.16
Elution time (s) 53 67 102 147 217
Peak width at
7 10 15 22 33
base (s)

16. Assuming equal molar absorptivities, which of the analytes is of highest


concentration in the sample?
a) A pe..Lc.. ~ -;:. y~ (b(ue.)("'e~8'4+)
b) B O? .4? C ? 11"

c) C

(]D D

e) insufficient information provided.

17. What is the selectivity associated with species Band C?

-/:; ~ (c.. - -t..M.. I L.{ 1- -r.3


a)
b)
c)
1.88
0.69
1.44
(j.. -
~

-
t:"'J 0 - -tM,

-
.-
/0).. -'>3
:::. 1.9.2­

d) 0.52

1.92
®
18. For which component is the efficiency greatest?
)J.A -:- 1-1 g-
a) A V"t

@ B }/rJ = T.Jlf
c) C ;V(...:;: -=i-/'7
d) 0 }I D ~ 6(( (
e) For a given column and mobile phase, the efficiency is the same for
all analytes.

19. Assuming a plate height of 0.014 cm, at what distance along the column
was component B separated from component A with a resolution of 1.5?

a) 10.0 cm

b) 6.1 cm

c) 8.2 cm

@ 4.3cm

e) insufficient information provided.

20. How much time did component C spend in the mobile phase?

a) 94 s

b) 147 s

@ 53s

d) 7 s

e) insufficient information is provided.

~ ::: \. 5

H::: 0. 0 't..t

t.t -= r-.1 ..5


10 c. ..... /
lO~ - >.3

:I
( \+ D.C\ ~)

10 cW\­
10 J..s
I1G -nFEcell
~

I1Go ~ -nFE;ell ~ -RT In K eq


for aA + bB +... !::; cC + dO + ...

E = EO _ 0.0592 log [CnDt .


n [A]Q[B]b at 25°C
E:= IR
Eapplied = (Ecathode - Eanode) -IR-II

96,485 C = 1 faraday (F)

(charge of 1 mole of elementary charges)

n = Q
A nF

1 = Q/t where I is constant current, Q is charge, t is time


Q =It
Separations equations:

n.==
I

V
[A]aq - [A] org V
aq
V K
aq + org D

[A ]aq,i

[A ]aq,O

[A Jorg,i
[A Jorg,O
C org
D=­
c aq
i
CA·
,aq,l Vaq
C A,aq,O -
( V aq + VorgD J

i
C A,org,i D V org

C A,org,O -
( V aq + VorgD J

D= K
[W] .KD =
1+~+ 1q IH+ ]+ K a D for organic acids

and

K - (aJ~ _ [Al~
C - (aA)M - [AIw
L
U==­
tM
L
V==­
tR
t R ==t s +t M
(5"2 LW 2
H=-=-­
L 16t~

H := A + _B + (Cs + C M )u
U

t := 16R~H( a J2 (l+kBy
R,B
u a- 1 k2
B

You might also like