AKZ 9 series
Features P1∼2
Principle/
P3
Piping system diagram
Description of
P4
model symbols
Specifications/
P5∼6
Range of use
Cooling capacity
P7∼8
characteristic chart
Outside dimension
P9∼18
diagram
Optional parts
Thermistor P19
Optional
P20
communication board
Supplement information
Control panel/Operation
P21∼22
mode/Setting method
Electric schematic
P23
diagram
Electric wiring connection
P24
instruction diagram
Notes for
P25∼27
handling
Method of
P28
selection
High-accuracy, Energy-saving, Compact
Environmentally Friendly
Table of history P29
9 AKZ
SERIES
Oil Hydraulic Division
Oil Hydraulic Equipment
9 AKZ
SERIES
RoHS Compliant
Circulation type
AKZ 9 SERIES
Features
Features
20%
*2
80
High load
Heat release value
60
Low-load 40
No load
20
Time 0
■AKZ 9 series Non-inverter AKZ 8 AKZ 9
unit(Daikin) series series
Outlet oil temperature control
*1. Comparison taking a non-inverter unit to have a power consumption of 100
*2. Measured during Daikin’ s model operation patterns
Compact design of top class in the industry *Compared with AKZ 439 class(Unit: mm)
9series
The AKZ 9
7series 8series series
comes top
in the
industry
1,020
More
875
990
compact
440
440 440
360 360 360
1
Features
Reinforce durability for mist or dust in the severe condition of factory Functions featured
■The ingress protection of the control box has been upgraded ■Refrigerant gas leakage detection alarm function
(equivalent to IP54). An alarm signal is output when the refrigerant gas
■Electronic components resistant to sulfidization have been adopted. would be leaked (as cooling circuit failure).
■Temperature warning function
A warning signal can be output when the oil temperature or air
Higher durability for long-distance transportation
temperature strays outside arbitrarily setting range.
AKZ 9 SERIES
■The specifications for withstanding vibration during transport ■Auto tuning function
have been upgraded to reflect actual transportation conditions. This function substantially cuts the time taken for
adjustment during trial operation by automatically setting
Five types of semi-standard specification units in addition to the gain when oil temperature control is not stable in the
the standard type to achieve shorter product delivery terms factory setting status or when optimization is required.
■999-hour timer function (ON timer)
Different
Individual With heater With tank voltages The operation start time can be set from 0 to 999
Compliance
specifications for With breaker with CE hours in one-hour units.
general purpose
Features
are set as
New functions for ease of use
semi-standard
types
■Preventive maintenance function
●A warning signal is output to notify that maintenance is
required when the air filter or condenser becomes clogged.
●If the thermistor fails (out of control), emergency operation is
Easy monitoring of operating status possible by selecting another operation mode.
This function minimizes the factors of line stoppages.
■The room temperature, inlet and outlet oil temperatures and other internal
data can be monitored at a personal computer using Hybrid-Win*. Improved operability/maintainability
This data can be displayed collectively, making it easy to grasp the
operating status. ■The control panel has been revamped. Data is now displayed
*Hybrid-Win is a software tool for monitoring the internal status of the unit using a personal computer. in an easier-to-understand format with more digits space.
You can download the tool and its instruction manual free of charge from The power consumption is also displayed (new function).
the website (http://www.daikinpmc.com) after registering as a user.
*The communications cable and the monitor harness must be purchased separately.
■The newly adopted plug-in terminal block has enabled
tool-less connection of signal cables (simple connection).
RS232C Monitor harness ■The increased pitch of the condenser’
s fins suppresses
communications cable for oil cooling units
clogging and makes cleaning easier.
(1.5 mm previously → 1.8 mm)
Applications
Spindle
M Tool
Hydraulic unit
Workpiece Bed Example of use at machining center
2
Principle and overall system diagram 9 AKZ
SERIES
Control board
Room temperature thermistor(To *4)
Inlet oil temperature thermistor(To *1)
Outlet oil temperature thermistor(To *2)
Machine temperature
Oil temperature control thermistor(To *3) synchronous thermistor(To *5)
〈Optional parts〉 〈Optional parts〉
Pressure reducing mechanism
B
C (Oil) Oil outlet
*5
D *2
︵ Cooler
︶
Fan
AKZ 9 SERIES
(Suction air)
*4
Condenser
E
M Evaporator
Machine tools
Bypass mechanism
*1
Oil inlet
*3
(Refrigerant) M
Principle and overall system diagram/series piping system diagram
A Oil pump
Note)1. Refer to Pages 19 and
(Compressor)
20 for optional parts.
Tank 2. Refer to Pages 21 and
22 for detailed setting
and others.
【Refrigerating cycle】
A:Refrigerant gas is converted into compressed gas at high temperature and high pressure by a compressor so that gas can be easily cooled and liquefied by a condenser.
B:In the condenser, the gas at high temperature and high pressure made in the compressor is cooled with air and converted into liquid at high temperature and high pressure.
C:The pressure reduction mechanism reduces the pressure of the liquid at high temperature and high pressure and converts it into liquid at low temperature and low pressure
by squeezing it so that it can be easily evaporated in a cooler.
D:In the cooler, liquid at low temperature and low pressure made in the pressure reduction mechanism removes heat from oil, evaporates(cools oil),
and is converted into gas at low temperature and low pressure.
E:The bypass mechanism controls the cooling capacity at low loads by adjusting the volume of gas at high temperature and high pressure supplied to the cooler.
Electronic
Control board expansion
valve
*1
*2 *5
*3 Outlet oil Oil outlet
*4 *4
*5 temperature
Electronic thermistor
Evaporator
Low pressure
Hot gas
gauge port
Fan bypass valve
Oil
pump
*3 M
Condensation
temperature
M
thermistor
Filter Relief valve
Compressor protection *2
thermostat Discharge gas
(-C type only) temperature thermistor Spindle
S2T
Accumulator
MC *1
compressor Inlet oil Oil inlet
temperature
thermistor
Tank
3
Description of model symbols 9 AKZ
SERIES
AKZ ※※ 9 - ※※※
1 2 3 4
1 Oil cooling unit identification code 3 Symbol of series (Symbol to represent model change)
AKZ : High-accuracy inverter oil cooling unit 9 “9”
: series
[Circulation type, for spindle and lubricant]
AKZ 9 SERIES
4 Symbol of option type/Non-standard number
2 Cooling capacity (kW)
Options and their combinations (Refer to the following table.)
14 : 1.4 kW 56 : 5.6 kW
32 : 3.2 kW 90 : 9.0 kW Special specifications
43 : 4.3 kW (dual pumps, specified paint colors, etc.)
-※※※ (3-digit number), C※※※ (3-digit number), etc.
Please consult us about detailed information.
4
9 AKZ
SERIES
AKZ149
AKZ329
Specifications
Note)*1. The cooling capacity represents the value at the standard point (inlet oil temperature: 35℃, room temperature: 35℃, oil for use: ISO VG32) .
The tolerance of the product is approx.±5%.
*2. Be sure to use a commercial power supply for the power source. The use of an inverter power supply may cause burn damage to the unit.
The voltage fluctuation range should be within ±10%. If the voltage fluctuation range is more than ±10%, please consult us.
*3. There are three types of different voltage specifications depending on the power source: −046, −047 and −048 units. −047 and
−048 units deal with the different voltage by featuring a transformer.
The main circuit voltage is the transformer’ s secondary side voltage of 200 VAC, 50/60 Hz.
(−046 units have no transformer and therefore have the same external dimensions and mass as standard units. Their main circuit voltage is 220/230 VAC, 50/60 Hz.)
*4. The machine temperature synchronous thermistor optionally available is required for this function. (Refer to Page 19 for details.)
*5. The SDS (Safety Data Sheet)of refrigerant R410A is attached to ーC type.
*6. Electric component box ingress protection: IP54 or equivalent (However, use piping conduits etc. rated at least IP54 at wiring ports.)
*7. The molded-case circuit breaker is not supplied with this product. Please prepare it by yourself.
*8. The yellow line on the tank oil level gauge shows the highest oil level and the red line the lowest oil level.
*9. The maximum power consumption/maximum current consumption of different voltage specifications are shown in the tables below.
5
Oil Cooling Unit horsepower(HP) 2.0 3.0
AKZ569 AKZ569 AKZ909
AKZ909 Model name Stan
dard ーB ーC ーT *8 ーH Different voltage
specifications *3
Stan
dard ーB ーC ーT *8 ーH Different voltage
specifications *3
Cooling capacity(50/60Hz) kW *1
5.0/5.6 8.0/9.0
Heater kW ー 2 ー ー 3 ー
Supply power*2 3-Phase AC 200/200・220V 50/60Hz *3 3-Phase AC 200/200・220V 50/60Hz *3
Main circuit*3 3-Phase AC 200/200・220V 50/60Hz
Circuit voltage
Operating circuit DC12/24V
200V 50Hz 2.22kW/7.6A 2.50kW/8.3A 4.25kW/13.5A
Max. power consumption
200V 60Hz 2.30kW/7.5A 2.57kW/8.0A *9 4.30kW/13.4A *9
Max. consumption current
220V 60Hz 2.30kW/7.2A 3.00kW/8.8A 4.30kW/12.9A
Transformer capacity ー 4.0kVA ー 6.0kVA
Exterior color Ivory white
Outside dimensions(H×W×D) mm 1110×470×560 1375×470×580 1410×470×560 1360×470×590 1220×560×680 1485×560×700 1520×560×680 1470×560×659
Compressor(Totally enclosed DC swing type) Equivalent to 1.5kW Equivalent to 2.2kW
Evaporator Brazed plate type
Condenser Cross-fin coil type
AKZ 9 SERIES
Propeller fan Motor φ400、100W φ455、100W
Motor 0.7kW−4P
Oil
pump Theoretical discharge rate L/min 30/36
Open pressure MPa 0.6
Syn- Standard (Set to“Room temperature: Mode 3”by default)
Room temperature or machine temperature *4
chroni-
Temperature zation Object to be controlled Inlet oil temperature or outlet oil temperature
(Set to“Inlet oil temperature”by default)
adjust type Synchronization
range K −9.9∼+9.9 against the standard temperature
(Set at 0.0 by default)
(Selectable)
Fixed Object to be controlled Inlet oil temperature or outlet oil temperature
type Range ℃ 5∼50
30
20
10
0
0 10 20 30 40 50
Inlet temperature
(℃)
6
9 AKZ
SERIES
Cooling capacity characteristic chart
AKZ149 1,800
Oil temperature =
1,600 Room temperature +10℃
Oil temperature =
(W)
1,400
Room temperature
1,200
Cooling capacity
Oil temperature =
1,000
Room temperature −10℃
800
600
400
200
0
5 10 15 20 25 30 35 40 45
Room temperature
(℃)
AKZ 9 SERIES
AKZ329 4,000
Oil temperature =
3,500
Room temperature +10℃
Cooling capacity characteristic chart
(W)
3,000
Oil temperature =
Cooling capacity
1,500
1,000
500
0
5 10 15 20 25 30 35 40 45
Room temperature
(℃)
AKZ439 6,000
5,000
(W)
Oil temperature =
Room temperature +10℃
4,000
Cooling capacity
Oil temperature =
Room temperature
3,000 Oil temperature =
Room temperature −10℃
2,000
1,000
0
5 10 15 20 25 30 35 40 45
Room temperature
(℃)
7
AKZ569 7,000
(W)
5,000
Oil temperature =
Cooling capacity
Room temperature
4,000 Oil temperature =
Room temperature −10℃
3,000
2,000
1,000
0
5 10 15 20 25 30 35 40 45
AKZ 9 SERIES
Room temperature
(℃)
AKZ909 12,000
10,000
Oil temperature =
Room temperature +10℃
8,000 Oil temperature =
Cooling capacity
Room temperature
6,000 Oil temperature =
Room temperature −10℃
4,000
2,000
0
5 10 15 20 25 30 35 40 45
Room temperature
(℃)
8
9 AKZ
SERIES
AKZ149(-B,-C,-046)
Outside dimension diagram
Standard specifications
Note)Refer to Page 5
for more details.
With breaker
Part No.
The positions of the fixing bolt holes are compatible with the AKZ 8 series, but the
positions of the oil outlet/inlet and the power supply/signal cable inlet ports are not.
Compliance with CE
Name Description
Different voltages (without transformer)
⑳
Opposite
⑩ side ⑧ (10)
⑪ Opposite
side ⑦
(700)
AKZ 9 SERIES
(674)
⑫ ③
650
(520)
513
Suction air (13)
①
253
106
④
30 300
360 4-U slots
15 410 66
(for fixing bolts)
440 328
Outside dimension diagram
30
12 60 216 60 12
AKZ149-H With heater Part No. Name Description Part No. Name Description
1 Oil inlet Rc3/4 11 Room temperature thermistor
2 Oil outlet Rc1 1/4 12 Unit faceplate
3 Oil drain Rc1/4 Plugged 13 Design faceplate
4 Oil pan drain M6 Plugged 14 Instruction faceplate
5 Control panel 15 Overall caution plate
6 Electric component box lid 16 Electric schematic diagram faceplate
(505)
7 Power supply inlet (Right) φ28 Hole 17 Battery charge mark faceplate
8 Signal line inlet (Right / Left) φ22 Hole 18 Cutting injury caution plate
9 Eye plate φ25 Hole 19 High temperature caution plate
⑰ 10 Air filter 20 Caution plate
21 Heater box
⑱ Exhaust air 22 Heater drain Rc1/4 Plugged
23 Air bleeder Rc1/4 Plugged
38 (365)
⑲ (413) ⑮⑯ Rear face
(160)
⑬ ⑨ ⑦
⑥ ⑧
⑤ ⑳
90
⑩ Opposite
side ⑧
⑪
⑫
66 ③
650
(1000)
(974)
Suction air
(13)
① 328
(820)
④
Opposite
⑭
side ⑰
553
②
406
314
300
190
111
79
123
30 15 410 111
30 300 4-φ12 holes 440 283
(50) 360 (for fixing bolts)
9
AKZ149-T With tank Part No. Name Description Part No. Name Description
1 Oil inlet Rc3/4 12 Unit faceplate
2 Oil outlet Rc3/4 13 Design faceplate
3 Oil drain Rc1/4 Plugged 14 Instruction faceplate
4 Oil pan drain M6 Plugged 15 Overall caution plate
5 Control panel 16 Electric schematic diagram faceplate
6 Electric component box lid 17 Battery charge mark faceplate
7 Power supply inlet (Right / Left) φ28 Hole 18 Cutting injury caution plate
8 Signal line inlet (Right / Left) φ22 Hole 19 High temperature caution plate
(635)
⑳
Opposite
⑩ side ⑧ (10)
AKZ 9 SERIES
⑪ Opposite
side ⑦
③
⑫
650
(860)
(834)
Suction air
(680)
673
④
①
413
Yellow line 15L
125
123 4-φ12 holes 105 410 20 66
30 300 (for fixing bolts) 535 110
360
AKZ149-047,-048 Different voltages (With transformer) Part No. Name Description Part No. Name Description
1 Oil inlet Rc3/4 11 Room temperature thermistor
2 Oil outlet Rc3/4 12 Unit faceplate
3 Oil drain Rc1/4 Plugged 13 Design faceplate
4 Oil pan drain M6 Plugged 14 Instruction faceplate
5 Control panel 15 Overall caution plate
6 Electric component box lid 16 Electric schematic diagram faceplate
(500)
60 38
⑨
553
406
⑧
(270)
314
300
⑦
270
123
30
15 410 ⑰ 66
4-φ12 holes
30 300 (for fixing bolts) (13) 440 (13) 328
360 (50)
Note) *1. The hanging fitting is located below. Do not use this fitting for hanging.
10
9 AKZ
SERIES
AKZ329(-B,-C,-046)
Outside dimension diagram
Standard specifications
Note)Refer to Page 5
for more details.
With breaker
Part No.
The positions of the fixing bolt holes are compatible with the AKZ 8 series, but the
positions of the oil outlet/inlet and the power supply/signal cable inlet ports are not.
Compliance with CE
Name
Different voltages (without transformer)
⑬ ⑨ ⑦ (160)
⑥ ⑧ ⑭
⑤ ②
90
⑳
Opposite
⑩ side ⑧ (10)
⑪ Opposite
side ⑦
⑫
(825)
(799)
AKZ 9 SERIES
775
(645)
648
Suction air
(13)
①
253
④
106
15 410
30 300 66
4-U slots 440 328
360
Outside dimension diagram
30
5
12 60 216 60 12
AKZ329-H With heater Part No. Name Description Part No. Name Description
1 Oil inlet Rc3/4 11 Room temperature thermistor
2 Oil outlet Rc1 1/4 12 Unit faceplate
3 Oil drain Rc1/4 Plugged 13 Design faceplate
4 Oil pan drain M6 Plugged 14 Instruction faceplate
5 Control panel 15 Overall caution plate
6 Electric component box lid 16 Electric schematic diagram faceplate
(505)
7 Power supply inlet (Right) φ28 Hole 17 Battery charge mark faceplate
8 Signal line inlet (Right / Left) φ22 Hole 18 Cutting injury caution plate
⑰ 9 Eye plate φ25 Hole 19 High temperature caution plate
⑱ 10 Air filter 20 Caution plate
21 Heater box
Exhaust air 22 Heater drain Rc1/4 Plugged
⑮⑯ Rear face 23 Air bleeder Rc1/4 Plugged
⑲ (413) 38 (365)
(160)
⑬ ⑨ ⑦
⑥ ⑧ ⑳
⑤
90
⑩ Opposite
side ⑧
⑪
⑫
775
66 ③
(1125)
(1099)
Suction air
(945)
(13)
① 328
④
⑭
Opposite
side ⑰
553
②
406
314
300
190
111
79
11
AKZ329-T With tank Part No. Name Description Part No. Name Description
1 Oil inlet Rc3/4 13 Design faceplate
2 Oil outlet Rc3/4 14 Instruction faceplate
3 Oil drain Rc1/4 Plugged 15 Overall caution plate
4 Oil pan drain M6 Plugged 16 Electric schematic diagram faceplate
5 Control panel 17 Battery charge mark faceplate
6 Electric component box lid 18 Cutting injury caution plate
7 Power supply inlet (Right / Left) φ28 Hole 19 High temperature caution plate
(635)
AKZ 9 SERIES
side
⑫
775
③
(1015)
(989)
(835)
Suction air
838
④
①
443
155
123 4-φ12 holes 105 410 20 66
30 300 (for fixing bolts) 535 110
360
AKZ329-047,-048 Different voltages (With transformer) Part No. Name Description Part No. Name Description
1 Oil inlet Rc3/4 11 Room temperature thermistor
2 Oil outlet Rc3/4 12 Unit faceplate
3 Oil drain Rc1/4 Plugged 13 Design faceplate
4 Oil pan drain M6 Plugged 14 Instruction faceplate
5 Control panel 15 Overall caution plate
6 Electric component box lid 16 Electric schematic diagram faceplate
(500)
Suction air
(13)
①
948
④ 60 38
⑨
553
406
⑧
(270)
314
300
270
123
30
4-φ12 holes 15 410 ⑰ 66
30 300 (for fixing bolts) (13) 440 (13) 328
360 (50)
Note) *1. The hanging fitting is located below. Do not use this fitting for hanging.
12
9 AKZ
SERIES
AKZ439(-B,-C,-046)
Outside dimension diagram
Standard specifications
Note)Refer to Page 5
for more details.
With breaker
Part No.
The positions of the fixing bolt holes are compatible with the AKZ 8 series, but the
positions of the oil outlet/inlet and the power supply/signal cable inlet ports are not.
Compliance with CE
Name
Different voltages (without transformer)
⑬ ⑨ ⑦ (160)
⑧ ⑭
⑥
⑤ ②
90
⑳
Opposite
⑩ side ⑧
⑪ Opposite (10)
side ⑦
⑫
(925)
(899)
AKZ 9 SERIES
875
(745)
708
Suction air ③
(13)
①
253
④
106
30 300
4-U slots
Outside dimension diagram
360 15 410 66
(for fixing bolts)
440 328
123
14
30
5
12
AKZ439-H With heater Part No. Name Description Part No. Name Description
1 Oil inlet Rc3/4 11 Room temperature thermistor
2 Oil outlet Rc1 1/4 12 Unit faceplate
3 Oil drain Rc1/4 Plugged 13 Design faceplate
4 Oil pan drain M6 Plugged 14 Instruction faceplate
5 Control panel 15 Overall caution plate
6 Electric component box lid 16 Electric schematic diagram faceplate
(505)
7 Power supply inlet (Right) φ28 Hole 17 Battery charge mark faceplate
⑰ 8 Signal line inlet (Right / Left) φ22 Hole 18 Cutting injury caution plate
9 Eye plate φ25 Hole 19 High temperature caution plate
⑱ 10 Air filter 20 Caution plate
21 Heater box
Exhaust air
⑮⑯ Rear face 38 (365)
22 Heater drain Rc1/4 Plugged
⑲ (413) 23 Air bleeder Rc1/4 Plugged
⑬ ⑨ ⑦ (160)
⑥ ⑧ ⑳
⑤
90
⑩ Opposite
side ⑧
⑪
⑫
875
③
(1225)
(1199)
66
Suction air
(1045)
(13) ① 328
④
Opposite
⑭
side ⑰
②
553
406
314
300
190
111
79
13
AKZ439-T With tank Part No. Name Description Part No. Name Description
1 Oil inlet Rc3/4 13 Design faceplate
2 Oil outlet Rc3/4 14 Instruction faceplate
3 Oil drain Rc1/4 Plugged 15 Overall caution plate
4 Oil pan drain M6 Plugged 16 Electric schematic diagram faceplate
5 Control panel 17 Battery charge mark faceplate
6 Electric component box lid 18 Cutting injury caution plate
7 Power supply inlet (Right / Left) φ28 Hole 19 High temperature caution plate
(635)
(372)
⑨ ⑦ 38 (365)
⑬
⑥ ⑧ ⑭
⑤
90 (160)
⑳ ②
⑩ Opposite
side ⑧
⑪ Opposite
(10)
side ⑦
⑫
AKZ 9 SERIES
875
(1115)
(1089)
③
Suction air
(935)
898
④
①
443
155
123 4-φ12 holes 105 410 20 66
30 300
(for fixing bolts) 535 110
360
AKZ439-047,-048 Different voltages (With transformer) Part No. Name Description Part No. Name Description
1 Oil inlet Rc3/4 11 Room temperature thermistor
2 Oil outlet Rc3/4 12 Unit faceplate
3 Oil drain Rc1/4 Plugged 13 Design faceplate
4 Oil pan drain M6 Plugged 14 Instruction faceplate
5 Control panel 15 Overall caution plate
6 Electric component box lid 16 Electric schematic diagram faceplate
(500)
Suction air
1008
(13)
①
④ 60 38
⑨
553
406
⑧
(270)
314
300
270
⑦
⑰
123 30 4-φ12 holes 15 410 66
30 300 (for fixing bolts)
(13) 440 (13) 328
360 (50)
Note) *1. The hanging fitting is located below. Do not use this fitting for hanging.
14
9 AKZ
SERIES
AKZ569(-B,-C,-046)
Outside dimension diagram
Standard specifications
Note)Refer to Page 6
for more details.
With breaker
Part No.
The positions of the fixing bolt holes and the oil outlet/inlet ports are compatible
with the AKZ 8 series, but the positions of the power supply/signal cable inlet ports are not.
Compliance with CE
Name
Different voltages (without transformer)
Inside (425)
Exhaust air
38
⑬⑳ face ⑨ ⑦ (191)
⑥ ⑧
⑤ 90
(13) ②
⑩ Opposite
⑪ side ⑧
Opposite ⑭
side ⑦ ③
⑫
(1160)
(1135)
AKZ 9 SERIES
1110
(980)
Suction air ①
875
597
④ 30 500 (13)
213
40 390 15 530 75
470 4-U slots 560 110
(For fixing bolts)
Outside dimension diagram
240
(16)
R6
12
327
22 60 306 60 22
AKZ569-H With heater Part No. Name Description Part No. Name Description
1 Oil inlet Rc1 1/4 11 Room temperature thermistor
2 Oil outlet Rc1 1/4 12 Unit faceplate
3 Oil drain Rc1/4 Plugged 13 Design faceplate
4 Oil pan drain M6 Plugged 14 Instruction faceplate
5 Control panel 15 Overall caution plate
6 Electric component box lid 16 Electric schematic diagram faceplate
7 Power supply inlet φ28 Hole 17 Battery charge mark faceplate
(517)
38 (425)
Inside ⑦
⑬⑳ face ⑨ (191)
⑧
⑥
⑤
⑩ Opposite
side ⑧
⑪
⑫
③
1110
(1370)
110
(1460)
(1435)
(1410)
Suction air
①
④
897
(13)
513
(316)
300
110 94
132
15 102
327
4-φ12 holes
530
560 240
②⑭
40 390
(for fixing bolts) 331
470
15
AKZ569-T With tank Part No. Name Description Part No. Name Description
1 Oil inlet Rc1 12 Unit faceplate
2 Oil outlet Rc1 1/4 13 Design faceplate
3 Oil drain Rc1/4 Plugged 14 Instruction faceplate
4 Oil pan drain M6 Plugged 15 Overall caution plate
5 Control panel 16 Electric schematic diagram faceplate
6 Electric component box lid 17 Battery charge mark faceplate
7 Power supply inlet (Right / Left) φ28 Hole 18 Cutting injury caution plate
⑰
(750)
8 Signal line inlet (Right / Left) φ22 Hole 19 High temperature caution plate
⑱ 9 Eye plate φ25 Hole 20 Model name nameplate
⑲ 10 Air filter 21 Oil tank 50L
11 Room temperature thermistor 22 Tank drain Rc3/8 Plugged
23 Oil level gauge* KLA-80A
⑮⑯ Rear face Exhaust air 24 Oil hole-cum-air bleeder HY-06T
88
(480) 38 (425) *The yellow line on the oil level gauge shows
(191) the highest oil level and the red line the lowest oil level.
⑬⑳ Inside face ⑨ ⑦ (Keep the oil level between the yellow and red lines during use.)
⑥ ⑧
⑤
90
(13) ②
⑩ Opposite
⑪ side ⑧
Opposite ⑭
side ⑦ ③
⑫
AKZ 9 SERIES
1110
(1425)
(1400)
(1375)
Suction air
(1245)
1140
④
862
①
AKZ569-047,-048 Different voltages (With transformer) Part No. Name Description Part No. Name Description
1 Oil inlet Rc1 1/4 11 Room temperature thermistor
2 Oil outlet Rc1 1/4 12 Unit faceplate
3 Oil drain Rc1/4 Plugged 13 Design faceplate
4 Oil pan drain M6 Plugged 14 Instruction faceplate
5 Control panel 15 Overall caution plate
6 Electric component box lid 16 Electric schematic diagram faceplate
(642)
⑬⑳ Inside face
38 (425)
⑥ ⑭
⑤
90
*1 (13)
⑩ ②
⑪
⑫ ③
1110
Suction air
(1230)
①
1125
④
847
30 500 (13)
⑦ ⑨
463
⑧
38
(202)
266
250
30
100
4-φ12 holes
327 (for fixing bolts) 60 ⑰ 75
(40) 390 (40) 30 530 110
470 (50) (13) 590 (13) 240
Note) *1. The hanging fitting is located below. Do not use this fitting for hanging.
16
9 AKZ
SERIES
AKZ909(-B,-C,-046)
Outside dimension diagram
Standard specifications
Note)Refer to Page 6
for more details.
With breaker
Part No.
The positions of the fixing bolt holes and the oil outlet/inlet ports are compatible
with the AKZ 8 series, but the positions of the power supply/signal cable inlet ports are not.
Compliance with CE
Name
Different voltages (without transformer)
50
⑥ ⑧
⑤
Opposite
⑪ side ⑧
⑩ ⑭
Opposite (13) ②
side ⑦
⑫
(1270)
(1245)
③
AKZ 9 SERIES
1220
(1130)
Suction air ①
790
512
④ 30 620 (13)
213
40 480 22.5 635 88
4-U slots
560 680 123
(For fixing bolts)
Outside dimension diagram
257
(16)
R6
12
400
30
5
AKZ909-H With heater Part No. Name Description Part No. Name Description
1 Oil inlet Rc1 1/4 11 Room temperature thermistor
2 Oil outlet Rc1 1/4 12 Unit faceplate
3 Oil drain Rc1/4 Plugged 13 Design faceplate
4 Oil pan drain M6 Plugged 14 Instruction faceplate
5 Control panel 15 Overall caution plate
6 Electric component box lid 16 Electric schematic diagram faceplate
(635)
7 Power supply inlet (Right / Left) φ28 Hole 17 Battery charge mark faceplate
⑰ 8 Signal line inlet (Right / Left) φ22 Hole 18 Cutting injury caution plate
⑱ 9 Eye plate φ25 Hole 19 High temperature caution plate
10 Air filter 20 Model name nameplate
21 Heater box
22 Heater drain Rc1/4 Plugged
⑲ Exhaust air
(570) ⑮⑯ Rear face 23 Air bleeder Rc1/4 Plugged
38 (545)
Inside ⑦ (311)
⑬⑳ face ⑨ ⑧
⑥
⑤
Opposite
⑪ side ⑧
⑩ ②
⑫
③
1220
(1570)
(1545)
(1520)
(1480)
Suction air ①
30 620 (13)
812
513
(316)
300
110 94
132
17
AKZ909-T With tank Part No. Name Description Part No. Name Description
1 Oil inlet Rc1 12 Unit faceplate
2 Oil outlet Rc1 1/4 13 Design faceplate
3 Oil drain Rc1/4 Plugged 14 Instruction faceplate
4 Oil pan drain M6 Plugged 15 Overall caution plate
5 Control panel 16 Electric schematic diagram faceplate
6 Electric component box lid 17 Battery charge mark faceplate
7 Power supply inlet (Right / Left) φ28 Hole 18 Cutting injury caution plate
(870)
⑰ 8 Signal line inlet (Right / Left) φ22 Hole 19 High temperature caution plate
⑱ 9 Eye plate φ25 Hole 20 Model name nameplate
⑲ 10 Air filter 21 Oil tank 70L
11 Room temperature thermistor 22 Tank drain Rc3/8 Plugged
23 Oil level gauge* KLA-80A
⑮⑯
88
HY-06T
φ36
50
⑥ ⑧
⑤
Opposite
⑪ side ⑧
⑭
⑩ Opposite
side ⑦
(13) ②
⑫
AKZ 9 SERIES
③
1220
(1535)
(1510)
(1485)
(1395)
Suction air
1055
④
①
777
Yellow line 70L
(281)
AKZ909-047,-048 Different voltages (With transformer) Part No. Name Description Part No. Name Description
1 Oil inlet Rc1 1/4 11 Room temperature thermistor
2 Oil outlet Rc1 1/4 12 Unit faceplate
3 Oil drain Rc1/4 Plugged 13 Design faceplate
4 Oil pan drain M6 Plugged 14 Instruction faceplate
5 Control panel 15 Overall caution plate
6 Electric component box lid 16 Electric schematic diagram faceplate
(747)
⑤
*1
⑩
⑪ (13)
⑫ ②
③
1220
Suction air
(1380)
①
1040
④ 30 620 (13)
762
⑦ ⑨
463
⑧
38
(266)
(250)
(202)
30
100
4-φ12 holes
400 (for fixing bolts) 60 ⑰ 88
(40) 480 (40) 30 635 123
560 (50) (13) 695 (13) 257
Note) *1. The hanging fitting is located below. Do not use this fitting for hanging.
18
Optional
parts Thermistor(Compatible with all types of Oil Cooling Unit 9 series)
(φ5)
27.5
AKZ9-OP-K10 10m control
( )
Implanted in
(φ4.5)
Lead wire
the machine
φ1.1
R1/8
For machine
AKZ9-OP-A5 5m Plug-in terminal
temperature
80 synchronous
25 AKZ 9
φ8
control
( )
Series
(φ4.5) Attached to the
Lead wire
surface of
φ1.1
AKZ9-OP-A10 10m
Optional parts
machine body
oil temperature control
SXH-001T-0.6
temperature
80
(φ5)
27.5 control
( )
Installed in
oil tube of the
(φ4.5)
Lead wire
Thermistor
R1/8
AKZ9-OP-Y10 10m machine
Thermistor characteristics: Resistance value … R25(Resistance value at 25℃)= 20kΩ, Tolerance: ±3%
AKZ9-OP-K Rc 1/8
(To be machined on the machine side) Connect to Oil Cooling Unit x 2M
( )
Machine Drill holeφ8, 20 or more in depth Terminal box Nos. 30 and 31.
body
AKZ9-OP-Y
Rc 1/8
Screw seat
Oil tube
Connect to Oil Cooling Unit control board connector CN11.
Replace this part with the oil outlet thermistor and operate
in the outlet oil temperature control mode Nos. 1, 5 and 6.
19
9 AKZ
SERIES
Optional parts
Optional communication board (serial communication board)
The following functions are enabled by mounting this option board on the Oil Cooling Unit and
connecting it to the machine:
1. The operation mode and the operation setting can be changed from the machine side.
2. The alarm code and temperature data(machine temperature, room temperature, inlet oil temperature,
outlet oil temperature, inlet and outlet differential temperature, inverter frequency)of Oil Cooling Unit can
Communication Specification
Model method Installation position Applicable model sheet No.
Serial communication Installation plate inside
AKZ9-OP-CS AKZ149、AKZ329、AKZ439、AKZ569、AKZ909 PSP04664
only (RS-232C) electric component box
Note)
1. Refer to the specifications sheet for the communication procedure and specifications.
2. Modbus communication system would be possible as well soon.
20
Supplement
information Parts names, functions and operation of control panel
1 6 2 3 4
5 7
8 9 10 11
NO. Item Description
1 Power lamp (Green) The lamp is turned on while power is supplied.
Displays the mode of the control panel NORMAL: Normal mode MONITOR: Monitor mode
5 Operation mode display
SETTING: Operation setting mode TIMER SET:Timer setting mode
Operation mode / Displays the current operation mode (Normal mode, Operation setting mode) or
6
Data No. display data number of the data currently displayed on the data display.
7 Data display Displays various data. The data displayed differs depending on the operation mode and data number.
8 [SELECT]key Selects the operation mode.
Decrements the value of the operation mode, data number and data by 1.
9 [DOWN]key
When held for two seconds or longer, decrements the values by 10.
Increments the value of the operation mode, data number and data by 1.
Parts names, functions and operation of control panel
10 [UP]key
When held for two seconds or longer, increments the values by 10.
11 [ENT](Determine) key Determines the operation mode, data number, and data to be changed.
Operation
lock mode
Normal
mode Hold down for more than 5 seconds.
NORMAL
Operation Timer Auto tuning
setting mode setting mode mode
SETTING TIMER SET
Hold down for more than 5 seconds.
Monitor
mode
Parameter
MONITOR setting mode
21
Supplement
9 AKZ
SERIES
AKZ 9 Series
Mode No. Mode name Description Setting temperature range Necessary optional part
Inlet oil temperature, Keep the inlet oil temperature at the setting temperature
Mode 0 fixed temperature control within the range specified in the right column. 5∼50℃
Outlet oil temperature or Keep the outlet oil temperature or return Oil temperature control
Mode 1 return oil temperature control oil temperature at the setting temperature within 5∼50℃ thermistor (When return oil
Fixed temperature control the range specified in the right column. temperature is controlled)
Inlet oil temperature, room Keep the inlet oil temperature at the setting temperature Between Room temperature
Mode 3 temperature synchronous control within the range specified in the right column. -9.9℃ and Room temperature + 9.9℃
Inlet oil temperature, machine Keep the inlet oil temperature at the setting temperature Between Machine temperature Machine temperature
Mode 4 temperature synchronous control within the range specified in the right column. -9.9℃ and Machine temperature+ 9.9℃ synchronous thermistor
Outlet oil temperature or return oil Keep the outlet oil temperature or return Between Room temperature Oil temperature control
Mode 5 temperature control, room oil temperature at the setting temperature within
-9.9℃ and Room temperature + 9.9℃ thermistor (When return oil
temperature synchronous control the range specified in the right column. temperature is controlled)
Oil temperature control
Outlet oil temperature or Keep the outlet oil temperature or return thermistor (When return oil
return oil temperature control Between Machine temperature
Mode 6 Machine temperature oil temperature at the setting temperature within
-9.9℃ and Machine temperature + 9.9℃
temperature is controlled)
the range specified in the right column. Machine temperature
synchronous control synchronous thermistor
Note) 1. Modes 2, 7, and 8 cannot be used on this series. Note) 2. Refer to Page 19 for details of necessary optional parts.
■Setting procedure
Default setting: Set to“Mode: 3”and temperature to“0.0”. When you use your unit at a setting other than
the default setting, change the setting following the procedure shown below.
1 Power ON --- Release the operation lock mode before starting operation for the first time.
Hold down the key and key simultaneously for more than 5 seconds.
Supplement information
2 Select the“Setting”mode and press the key once.
1 Outlet oil temperature or return oil temperature【Th2】 *1 6 Cooling capacity control command value(%) −
*1. If the thermistor is not connected or has a broken wire, −99.9 is displayed.
*2. With the default setting, 0 is displayed. Note that display is enabled when parameter n020 is“1”or the optional communication expansion board is installed.
*3. This is the value obtained by rough calculation under the following conditions (the error is around 20%): power supply voltage of
200 V, pump discharge pressure of 0.2 MPa (VG32: oil temperature 25℃). Contact us separately about pumpless units.
22
23
Electric schematic diagram Supplement information
MCCB
X3M Tr
L1 Black (red)
Input Black (white)
L2 Output
L3 Black
0V
L1 Black (red)
L2 Black (white)
A2P U Yellow
L3 Black
2 CN15 V Red
DCL FU550 +
W White
A3P ∼ GND Black M
3.15A 250V
X500 - - Vcc Brown DC M3F
For −B units only Hu Orange
Hv Blue
X1M CN600 COR
L1 Black (red) L1 R Black R + DCL1 DCL2
C550 C551 + Red S172
Black (white) Black -
L2 L2 S S IC600 Yellow M θ S2T
L3 Black L3 T Black T ∼ - - Blue 3∼
N=4 CE type only
Surge X530 CN103 CN18 M2C
SA SA absorber 5
R S T X3M Relay control Th-Fin
K1S M1P
K2M X510
FU511 L1 T1 U1 FU650 Power supply circuit CN20
FU512 L2 T2 V1 M 3.15A 250V [Standard, −046
- +
Black
Black
Black
FU513 L3 T3 W1 3∼ (different voltage specifications, without transformer)]
6.3A 250V Photocoupler ∼ -
U2 V2 W2 CN650 A1P Control board
Relay control Black (red) A2P Inverter board
Black (white)
E1H t° t° CN110 CN6 Inverter CPU normal LED300 CN7 A3P Noise filter board
Black Th300
−H type only F1UT F2UT X501 X519 X520 A4P Display board
T1R 6 2 3 6 C Condenser
A1P Communication M
[Power supply] Red t°Black CN,S,X Connector
+12V
Model Supply power S60 For external communication S150 S151 S140 COR Ferrite core
Red Black Y2E
Standard , 3∼200/200・220V - (parallel) DCL Reactor
−C, −B, S200 ∼ FU Fuse
−T, −H 50/60Hz S130 S0 CN2
24 Power supply circuit K1S Overcurrent relay
3∼220・230V High-accuracy analog input Analog monitor
-046 M1P Motor (Pump)
50/60Hz A4P S80 S182 96 M2C Motor (Compressor)
3∼380・400・415V
-047 Protection equipment K1S M3F Motor (Fan)
50/60Hz LED140 LED_A SW0 S10 For shipping adjustments 95
Operational error CN12
input circuit S183 Machine temperature
3∼440・460・480V Th-1 synchronous thermistor (option)
-048 Board communicating Control CPU normal prevention switch For external
50/60Hz
communications (serial) Th-2 Outlet oil temperature thermistor
−H type only
4 X4M Th-3 Air (room temperature) thermistor
+12V S184 24 Th-4 Inlet oil temperature thermistor
5 S4T Th-6 Discharge gas temperature thermistor
A5P M
MR30Y S185 23 θ Th-7 Condensation temperature thermistor
S90
Y1E +15VE Th-8 EV valve outlet temperature thermistor
MR30X
Short-circuit line
Expansion user I/O Magnetic
Th-9 Oil temperature thermistor (option)
contact coil K2M Th-Fin Fin temperature thermistor
S160 −H type only
MR52Pa
MR30W
X2M Th300 Box temperature thermistor
9 10 11 12 13 30 31 60 61 62 63 64 65 66 67 T1R Transformer
Option S9 CN10 CN11 S179 S170 S172 S171
X1M,X2M Terminal block
ACDC Short- Short-circuit line Y1E,Y2E Electronic expansion valve
Th-4 Th-8 Th-3 Th-2 Alarm output circuit line
9 10 11 12 13 30 31 60 61 62 63 64 65 66 67
θ
Th-7 Th-9 S2T S3PH
[Semi-standard types]
Th-6 Option X4M -047, 048 only CE type only CE type only
Type name Additional part symbol
Electric schematic diagram(Typical diagram)
1 Power supply capacity … Refer to the max. power consumption and max. consumption
current of the specification sheet of each type.
2 Connection to power supply terminal block(X1M, Tr) (1)
(2)
(1)In the case of the standard type and semi-standard type L1 L2 L3
(−C, −H, −T, −046) , connect the line to X1M.
(2)In the case of“with breaker” (−B)specifications,
connect to the circuit breaker.
(3)In the case of the semi-standard type(with transformer:−047, −048), L1 L2 L3
connect the line to the terminal block supplied with the transformer.
(3)
1.Screw terminal and wiring diameter U V W
(X2M) CAUTION
MR52Pa
MR30W
Supplement information
1. To avoid the effects of noise, connect the power wire by
MR30X
Level 1 Level 1
error or Level 2 Power failure error or Level 2 Power failure
Normal Normal
Signal output Lock error (Power OFF) Lock error (Power OFF)
ON
Warning output(NO contact) 66−67 OFF
1. The following electric wires can be used on the 3. For [10] to [13], please prepare contacts to meet
CAUTION terminal block for straight crimp-style terminals. the condition of minimum applicable load 12V DC
Single wire: φ0. 57∼φ1. 44(AWG#22∼#16) and 5mA.
Stranded wire: 0. 25mm2∼1. 25mm(AWG#
2 22∼16) 4. When the length of the thermistor to be connected
2. Load applicable to [60 - 64] and [66 - 67] is as follows: to [30] − [31] is longer than 10m, or the wiring is
Min. applicable load: 10mV DC, 10μA or more routed in a poor noise environment, use shielded
Max. applicable load: 30V DC, 2A(Resistance load) wire.
24
Supplement
information Notes for installing external piping
Dynamic
viscosity
Temperature
Example of viscosity
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 °
F
(dynamic coefficient of
mm2/s -10 0 10 20 30 40 50 60 70℃ viscosity)
10,000 In winter: 195mm2/s
5,000 ISO VG32 Oil
3,000 (temperature 5℃)
2,000
In summer: 29mm2/s
1,000 ISO VG32 Oil
500 (temperature 40℃)
400
300 68
200
Notes for installing external piping
150
100
75
46
50
40
30
20 32
22
15
10
10
9.0
8.0
5
7.0
6.0
5.0 2
4.0
3.0
2.0
-10 0 10 20 30 40 50 60 70℃
25
Supplement
9 AKZ
SERIES
Supplement information
・Oil equivalent to NAS 10 level according to
the pollution level
×
● Chlorinated hydrocarbon series
● Water - Glycol series
● W-O & O/W emulsion series
(High-aqueous hydraulic oil)
Coolant fluid
● Water-soluble cutting
×
Notes for handling
and grinding liquid
● Non water-soluble
cutting and grinding oil
Ethylene glycol
(Antifreeze liquid) ×
Water(Industrial water) ×
Liquid equivalent to special flammables,
alcohol, first class petroleum and second
Inflammable liquid like fuel class petroleum of the fourth group
hazardous materials specified according
×
to the Fire Defense Law
Drugs ×
×
Drinking water, water for cooling food
Liquid for food products
products, etc.
26
Supplement
information Notes for handling
*Before operating this unit, be sure to read the operation manual and properly understand it.
1 General instructions
[ DANGER] ① Use the equipment only in accordance with the intended specifications(specified in brochure, specification sheet, operation manual, caution plate).
[ DANGER] ② Never operate the equipment in an explosive atmosphere
[ DANGER] ③ Do not disassemble, repair or modify the equipment by yourself.
[ DANGER] ④ Always comply with the laws and regulations for safety(Industrial Safety and Health Law, Fire Defense Law, JIS B 8361 Guidelines of Hydraulic System).
[ WARNING] ⑤ Caution in the event of refrigerant leak
・Ventilate a room adequately(to avoid the risk of suffocation) .
・Avoid direct contact of the refrigerant with skin(to avoid the risk of frost injury) .
・In the event of inhalation of a great deal of refrigerant, contact with skin, and refrigerant in the eye, seek medical attention immediately.
[ WARNING] ⑥ In the event of an abnormal condition, stop operation promptly, investigate the cause of the problem and take appropriate remedial measures.
[ CAUTION] ⑦ Do not use the unit in atypical environments (locations subject to high temperatures, high humidity, or
a lot of dust, contamination, particulate matter, steam, oil mist or corrosive gases: H2S,SO2,NO2 or CL2).
[ CAUTION] ⑧ Install a flow switch and temperature switch on the machine to protect the main shaft and others.
[ CAUTION] ⑨ Do not get on the equipment or place an object on the equipment.
[ CAUTION] ⑩ Operate the cooling unit at altitude of 2,000 m or less. If the altitude exceeds 1,000 m, the cooling capacity will be reduced
by about 20% to 30% due to the Atmospheric pressure drop. Select a model with sufficient margin for cooling capacity.
[ CAUTION] ⑦ Check to see that the oil piping has the pressure resistance of 1MPa or more and install the piping appropriately.
27
Supplement
9 AKZ
SERIES
information Method of selection of Oil Cooling Unit Unit conversion formula ● 1kW=860kcal/h
1.Select Oil Cooling Unit having a cooling capacity 20 to 30% larger than the heat release value from the
machine tool.
2.Since the cooling capacity of Oil Cooling Unit varies with the change of liquid temperature(inlet liquid
temperature)and room temperature, it is necessary to clarify the liquid temperature and room temperature
conditions to select appropriate Oil Cooling Unit.
3.Three methods are shown below as a guide for estimating the heat release value from the machine tool.
For determining the heat release value eventually, it is necessary to conduct tests and determine the
exact heat release value for selecting appropriate Oil Cooling Unit.
Q=2.778×10 -7Cp・γ・Vs・△T
T 1( ℃)
V(
s m 3/h)
Q : Heat release value
(kW)
Cp : Constant pressure specific heat(J/kg℃)
・・
・1967.4(J/kg℃)
T 2( ℃) γ : Weight volume ratio
(kg/m3)
・・
・876
(kg/m3)
Oil Cooling
Unit
(m3/h)
Vs : Oil flow rate
M △T: Temperature difference
(℃)
・・T2ーT1
・
E.g.)When“Vs”is 1.8m3/h(30L/min)and“△T”is 5℃
Machine
Q=2.778×10-7×1967.4×876×1.8×5
Oil tank =0.479×1.8×5≒4.3
(kW)
●Method 2: To estimate the heat release value from the increase rate of
oil temperature in the tank
Supplement information
Find the maximum gradient of oil temperature increase
( )
To find the maximum gradient of the oil
temperature, it is necessary to measure △t every
one minute during the first 10 minutes.
Tank oil
temperature
t1 Q=2.778×10 -7Cp・γ・V・△t/H
Oil temperature(℃)
H : Time
(h)
E.g.)When the total oil quantity is 300L(0.3m3)and“△t”
is 10℃.
Q=2.778×10-7×1967.4×876×0.3×10
=0.479×0.3×10≒1.4
(kW)
●Method 3: When motor output loss is considered to be the heat release value
Q : Heat release value
(kW)
H : Motor output
(kW)
…For driving the main shaft
η
Q=H・ η : Motor output loss
(%)
100
E.g.)When the output loss is 30% for the motor output 7.5 kW → The output
loss is 30% or so in general(Cooling of main shaft head)
Q=7.5×0.3=2.3
(kW)
28
Supplement
information Table of history of Oil Cooling Unit for cooling main shaft(Circulation type)
AKS→AKZ
Horsepower Cooling capacity
HP W Old New
10,000
AKS303K AKS303AK
9,500 ◇ ◇
AKZ306 AKZ(S)907 AKZ908 AKZ909
9,000 ◇ ◇ ◇ ◇
3.0
8,500
8,000
7,500
7,000
6,500
6,000
AKZ206 AKZ(S)567 AKZ568 AKZ569
5,500 ☆ ☆ ☆ ☆
AKS203K AKS203AK AKS205K
2.0 5,000 ☆ ☆ ☆
4,500
AKZ(S)437 AKZ438 AKZ439
◎ ◎ ◎
4,000
1.5
3,500 AKZ106 AKZ(S)327 AKZ328 AKZ329
Supplement information
1.2 □ □ □
AKS100Z □
3,000 ■
AKS103K AKS103AK AKS104K AKS105K AKS105AK AKZ(S)257
2,500 □ □ □ □ □ ※
1.0
2,000
AKS53K AKS54K AKS54AK AKS55K AKS55AK AKZ(S)147 AKZ148 AKZ149
0.5 1,500 △ △ △ △ △ ○ ○ ○
1,000 AKS33K AKS35K AKS35AK
○ ○ ○
0.3 500
Table of history
Series name AKS 3 series AKS 4 series AKS 5 series AKS-Z AKZ 6 series AKZ 7 series AKZ 8 series AKZ 9 series
Sales starting time − '87.5 '86 '87 '88.1∼10 '98.12 '88 '96.8∼10 '01.10∼'02.2 '02∼ '10∼ '12∼
Discontinuation time '87.5 '02.3 '88 '88 '93.3 '02.3 '97.3 '02.9 '05.3 '12.12 Current model
ON−OFF type Inverter type
Note)1. The larger the last number of a model name, the newer the series(For instance, AKS35K is newer than AKS33K) .
In addition, a model having the last alphabetic characters“AK”is newer than a model ending with“K”only. (For instance, AKS35AK is newer
than AKS35K) .
2. The cooling capacity is represented by the value at the standard point and at 60 Hz for all models.
3. The dimensions of the equipment may be changed on a newer type and older type on some models. Please check the dimensions on the
brochure and specification sheet(outline drawing)for selecting your equipment.
When you are about to buy new equipment due to a failure of the equipment or for other reasons, please check the conditions of new equipment
and select an appropriate type.
4. All the models have been changed to the inverter type since 2002.
5. AKSZ (S)
“7”series uses new refrigerant R407C, AKZ“8” , AKZ“9”series uses new refrigerant R410A, and all other models use R22.
6. Existing units of 1HP class(AKS105AK, AKZ (S)257 class)were integrated into AKZ328 of 1.2HP class.
29
Supplement
9 AKZ
SERIES
Germany
Korea
U.S.
Japan
China
India
Taiwan
Mexico
Thailand
Singapore
Indonesia
Supplement information
Please contact Daikin Sales Partners for servicing of Oil Cooling Unit in countries outside Japan.
Daikin is ready to offer you service in conjunction with the sales agents of our Air-conditioning
and Hydraulic Divisions located in seven countries and regions worldwide.
大金空調技術(広州)有限公司
Guangzhou
DAIKIN AIR CONDITIONING TECHNOLOGY (Guangzhou) CO.,LTD.
Korea Seoul ◎ KD HYDRAULICS,LTD.
Taiwan Taipei HO TAI SERVICE & MARKETING CO.,LTD.
Singapore Singapore ◎ ZICOM PRIVATE LTD.
Thailand Bangkok SIAM DAIKIN SALES CO.,LTD.
Indonesia Djakarta ◎ PT. ETERNA KARYA SEJAHTERA
India New Delhi DAIKIN AIR CONDITIONING INDIA
Germany Ulm ◎ SAUER BIBUS GMBH
U.S. Illinois ◎ ALL WORLD MACHINERY SUPPLY INC.
Mexico Querétaro ◎ ALL WORLD MACHINERY SUPPLY INC. Mexico Branch
30
9 AKZ
SERIES
Osaka Office
YODOGAWA PLANT
1-1,Nishi-Hitotsuya,Settsu,Osaka 566-8585,Japan
Home Page: http://www.daikinpmc.com/en/
●Contents in this catalog are subject to change for improvement without prior notice. GK245A
(2017.11.030)