Professional Documents
Culture Documents
CHECK PRODUCT
COMPLIANCE ON NEXT
ONLINE CONTROL OR END
LINE CONTROL
CHECK PRODUCT
COMPLIANCE ON NEXT
ONLINE CONTROL OR END
LINE CONTROL
MA
PROBLEM ON END
CONTROLLED UNTIL
PRODUCTS ? P
YES
NO
RECHECK ALL
PRODUCTIONS
POTENTIALLY IMPACTED
OF ON LINE OR INCOMING CONTROL NOK
ONLINE - INLINE
CONTROL NOK
YES
STOP PRODUCTION ON
CONCERNED
WORKSTATION OR ISOLATE
CONCERNED COMPONENT
STOP PRODUCTION ON
CONCERNED
WORKSTATION OR ISOLATE
CONCERNED COMPONENT
AINTAIN ONLINE OR
DLINE QUALITY WALL
IL THE SEMI FINISHED CORRECT PROCESS
PRODUCTS ARE
OK
NOK
RE CHECK
PROCESS OR
COMPONENT
COMPLIANCE
OK
RESTART PRODUCTION +
CHECK SAME
WORKSTATION ON OTHER
LINES
PROCESS OWNER LAST UPDATE DATE
OXYLANE PRODUCTION CONTROL PLAN
IN COMING CONTROL
ONLINE CONTROL
How MANY?
Date of
Supplier name: inspection: PL Name
ORDER DETAILS
Order Type:
CONCLUSION
COMMENTS
DECISIONS
Date of
Supplier name: PL Name
inspection:
ORDER DETAILS
Order Type:
CONCLUSION
COMMENTS
DECISIONS
HOW MANY
Mass Which if OK/NOK/
WHAT TO CONTROL CONTROL METHOD REQUIREMENT Implant Prod frequency? applicable? Finding details NA
SUB PART: TITRE1
CONTROL RESULT:
OXYLANE SUPPLIER:
Name: Signature: Name: Signature:
Date: Date:
LABORATORY TEST REPORT
Date of
Supplier name: PL Name
inspection:
INCOMING CONTROL
ORDER DETAILS
Order Type:
CONCLUSION
COMMENTS
DECISIONS
Table I, Sample Size Code Letters Table II, Single Sampling Plans For Normal Inspection
(Select the lot or batch size and your ideal inspection level to get the sample size code letter) (Check the sample size by the code letter and select your preferred AQL)
Special Inspection General Inspection Levels Sample Sample Acceptable Quality Levels (Normal Inspection)
Lot or Batch Size
S-1 S-2 S-3 S-4 I II III Size Size 0.010 0.015 0.025 0.040 0.065 0.100 0.150 0.250 0.400 0.650 1.000 1.500 2.500 4.000 6.5 10 15 25 40 65 100 150 250 400 650 1000
2 to 8 A A A A A A B Code Ac Ac Ac Ac Ac Ac Ac Ac Ac Ac Ac Ac Ac Ac Ac Ac Ac Ac Ac Ac Ac Ac Ac Ac Ac Ac
9 to 15 A A A A A B C Letter
A 2 0 1 2 3 5 7 10 14 21 30
16 to 25 A A B B B C D B 3 0 1 2 3 5 7 10 14 21 30 44
26 to 50 A B B C C D E C 5 0 1 2 3 5 7 10 14 21 30 44
51 to 90 B B C C C E F D 8 0 1 2 3 5 7 10 14 21 30 44
91 to 150 B B C D D F G E 13 0 1 2 3 5 7 10 14 21 30 44
151 to 280 B C D E E G H F 20 0 1 2 3 5 7 10 14 21
281 to 500 B C D E F H J G 32 0 1 2 3 5 7 10 14 21
501 to 1200 C C E F G J K H 50 0 1 2 3 5 7 10 14 21
1201 to 3200 C D E G H K L J 80 0 1 2 3 5 7 10 14 21
3201 to 10000 C D F G J L M K 125 0 1 2 3 5 7 10 14 21
10001 to 35000 C D F H K M N L 200 0 1 2 3 5 7 10 14 21
35001 to 150000 D E G J L N P M 315 0 1 2 3 5 7 10 14 21
150001 to 500000 D E G J M P Q N 500 0 1 2 3 5 7 10 14 21
500001 and Over D E H K N Q R P 800 0 1 2 3 5 7 10 14 21
Q 1250 0 1 2 3 5 7 10 14 21
R 2000 1 2 3 5 7 10 14 21
= Use the first sampling plan below the arrow. If sample size equals, or exceeds lot or batch size, do 100 percent inspection
EXAMPLE: Order of 5000 pieces, to be inspected on Level I EXAMPLE: AQL for this order is 2.5%
=> J = 80 pieces to pick => Max defect we can accept = 5
FINAL INSPECTION REPORT
ORDER DETAILS
Item
CONCLUSION
To check 2 pieces per size 1 measurement NOK --> Take 5 more pieces & control on the failed measurement. If 1
fondamental measurement OK
(or 3 pieces if order qty over 35000pcs) piece min of new sampling is NOK, the order result is REJECTED
To check 1 piece per size 1 measurement NOK --> Take 5 more pieces & control on the failed measurement. If 2
non fundamental measurement OK
(or 3 pieces if order qty over 35000pcs) pieces min of new sampling are NOK, the order result is REJECTED
VISUAL/MANUAL
Sampling qty: 32
Nb of defect found
What to control control Method Requirement Finding details Minor Major Critical
SUB PART:
No splinter, no crack, no
Aspect [Splinter-crack-funguses] Visual/Manual funguses, no sharp edge, no
sharp corner
Marking is correct, correct
position, clear, easy to read
Aspect [Marking - Colors] Visual
(compare to master sample)
No dust, contamination
Aspect [Dust-Contamination] Visual outside and inside of color
box
- Enough components
according to CDCT (6 plates,
3 pieces for cross, 1 screw
Components Visual
driver and 39 stainless steel
screws)
-- Standing parts (Kubb, King,
Correct assembly
skittles) are stable.
Stable Visual
- Plyometric box is stable
during assembling.
Sampling qty: 8
Nb of defect found
What to control control Method Requirement Finding details Minor Major Critical
SUB PART:
According to technical
Dimension Calipers
drawing
Weight Scale According to the CDCT
Static load test Test by 400kg and check by visual According to the CDCT
Sampling qty: 1
Nb of defect found
What to control control Method Requirement Finding details Minor Major Critical
SUB PART:
CONTROL RESULT:
OXYLANE SUPPLIER:
Name: Signature: Name: Signature:
Date: Date: