SKANC Database Changes :

1) Press window key from keyboard -> Click All Programs -> Click Microsoft SQL Server 2012
-> Click SQL Server Managment Studio -> Click "Connect"

2) Click on "+" Databases -> Click "+" SKAN_C -> Click "+" Tables

3) Go to Tools -> Options -> Designer -> Table and Database Designer -> "Unselect" option
Prevent saving changes that require table re-creation -> click OK.

4) (a) Go to SKAN_C database -> "+" Table -> Right click on P_Browser table -> Select Design-
> Add Recorded_Patient varchar(3) Checked -> Close table -> Message get displays
"Save Changes " click "Yes" .
(b) Select P_Browser table -> Right click on P_Browser table -> click Edit -> In
Recorded_Patient column if "NULL" for all feilds then change to "NO".

5) (a) Go to SKAN_C database -> "+" Table -> Right click on AnatomyProcedure table ->
Select Design -> Check Camera_Aparture int Checked felid Exists else ADD feild.
-> Close table -> Message get displays "Save Changes " click "Yes" .
(b) Right click on AnatomyProcedure table -> click Edit -> In Camera_Aparture column if
"NULL" for all feilds then change to "315".

6) (a) Go to SKAN_C database -> "+" Table -> Right click on ConfigurationDefaultSettings
table -> Select Design -> Add -> Live_Recording varchar(5) Checked -> Close table ->
Message get displays "Save Changes " click "Yes" .

(b) Right click on ConfigurationDefaultSettings table -> click Edit -> Change FramesLimit
to 100 and Live_Recording column if "NULL" for all feilds then change to "NO".

7) (a) Go to SKAN_C database -> "+" Table -> Right click on ConfigurationSetup table ->
Select Design -> Add -> Live_Recording varchar(5) Checked -> Close table -> Message
get displays "Save Changes " click "Yes".
(b) Right click on ConfigurationSetup table -> click Edit -> change FramesLimit to 100
and Live_Recording column if "NULL" for all feilds then change to "NO".

8) Go to SKAN_C database -> Table -> Right click on Restricted table -> Select Design ->
check PID varchar(20) Checked is exists else change
Camera Frame Rate check:

1) Press window key from keyboard -> Click All Programs -> Click Kappa Folder -> Click AFS2
Folder -> Click AFS2

2) Click File which is in top right corner -> Select Open AFS2 -> Dialog window get displays go
to path ="C:\Program Files\Kappa\AFS2\XML" and Select file H3XR_Kappa.afs2 -> Click
Open button

3) Click Hardware which is in top right corner -> Click Open option > Check HardwareDialog
window get display.

4) Create folder in D-Drive with name as KAPPA folder

5) Click Create new Profile List button -> Dialog window Create Profile List get displays

6) Click Browser button-> Go to path "D:\" and select folder "KAPPA"

7) Enter Profile List Name as "KAPPA" -> Click OK button

8) Click Create new Profile button -> Camera Profile dialogue window get displays -> Enter
New Profile Name as "Kappa" -> Click OK button

9) On Right side Interface - Transport-interface Select GigEVision option

10) In Image Select Format option as Y14 at left side

11) In Width and Height Enter value 1024 and GigE Packet Size as 9014 value

12) In Board option Select "0" and Port option select "0"

13) Select Open Live Window option at bottom-> Click Open button

14) New acquire window get displays

15) Check Frame Rate at top Left corner of window display as 30.0

You might also like