Professional Documents
Culture Documents
Test Principle:
Ion Selective Electrode (ISE) technology.
Composition :
Buffer <0.5%
Potassium salts <8.0%
Deionized water sq
Description :
Colorless solution
Handling precautions :
Avoid contact with skin or eyes
Keep the packaging closed when not in use
Safety informations :
- After contact with eyes, wash immediately with plenty of water
- If swallowed, vomit and seek medical advice
¨
Pack Presentation
Product code: FINELEMC0006
Package size: 1 x 100 ml
Test Principle:
Ion Selective Electrode (ISE) technology.
Composition :
Buffer <0.5%
Potassium salts <6%
Deionized water sq
Description :
Colorless solution
Handling precautions :
Avoid contact with skin or eyes
Keep the packaging closed when not in use
Safety informations :
- After contact with eyes, wash immediately with plenty of water
- If swallowed, vomit and seek medical advice
Pack Presentation
Product code: FINELEMC0007
Package size: 1 x 100 ml
Intended Use :
Passing the membrane potential of potassium electrode to the Ag/AgCl internal
eelectrode and calibrating the potassium electrode potential.
Filling solution for Potassium electrode
Test Principle:
Ion Selective Electrode (ISE) technology.
Composition :
Buffer <0.5%
Potassium salts <6%
Deionized water sq
Description :
Colorless solution
Handling precautions :
Avoid contact with skin or eyes
Keep the packaging closed when not in use
Safety informations :
- After contact with eyes, wash immediately with plenty of water
- If swallowed, vomit and seek medical advice
Pack Presentation
Product code: FINELEMC0005
Package size: 1 x 100 ml
Test Principle:
Ion Selective Electrode (ISE) technology.
Composition :
Buffer <0.5%
Potassium salts <6%
Deionized water sq
Description :
Colorless solution
Handling precautions :
Avoid contact with skin or eyes
Keep the packaging closed when not in use
Safety informations :
- After contact with eyes, wash immediately with plenty of water
- If swallowed, vomit and seek medical advice
Pack Presentation
Product code: FINELEMC0008
Package size: 1 x 100 ml
Test Principle:
Ion Selective Electrode (ISE) technology.
Composition :
Buffer <0.5%
Potassium salts <6%
Deionized water sq
Description :
Colorless solution
Handling precautions :
Avoid contact with skin or eyes
Keep the packaging closed when not in use
Safety informations :
- After contact with eyes, wash immediately with plenty of water
- If swallowed, vomit and seek medical advice
Pack Presentation
Product code: FINELEMC0009
Package size: 1 x 100 ml
Test Principle:
Ion Selective Electrode (ISE) technology.
Composition :
Organic buffer <0.1%
Inorganics salts <1.0%
Preservative <0.05%
Deionized water sq
Description :
Colorless and odorless solution
Assay values : refer to the label
Handling precautions :
Avoid contact with skin or eyes
Keep the packaging closed when not in use
Safety informations :
- After contact with eyes, wash immediately with plenty of water
- If swallowed, vomit and seek medical advice
Pack Presentation
Product code: FINELEMC0001
Package size: 1 x 100 ml
Test Principle:
Ion Selective Electrode (ISE) technology.
Composition :
Organic buffer <0.1%
Inorganics salts <1.0%
Preservative <0.05%
Deionized water sq
Description :
Colorless and odorless solution
Assay values : refer to the label
Handling precautions :
Avoid contact with skin or eyes
Keep the packaging closed when not in use
Safety informations :
- After contact with eyes, wash immediately with plenty of water
- If swallowed, vomit and seek medical advice
Pack Presentation
Product code: FINELEMC0020
Package size: 1 x 100 ml
Test Principle:
Ion Selective Electrode (ISE) technology.
Composition :
Organic buffer <0.1%
Inorganics salts <2.0%
Preservative <0.05%
Deionized water sq
Description :
Colorless and odorless solution
Assay values : refer to the label
Handling precautions :
Avoid contact with skin or eyes
Keep the packaging closed when not in use
Safety informations :
- After contact with eyes, wash immediately with plenty of water
- If swallowed, vomit and seek medical advice
Pack Presentation
Product code: FINELEMC0018
Package size: 1 x 100 ml
Test Principle:
Ion Selective Electrode (ISE) technology.
Composition :
Organic buffer <0.1%
Inorganics salts <2.0%
Preservative <0.05%
Deionized water sq
Description :
Colorless and odorless solution
Assay values : refer to the label
Handling precautions :
Avoid contact with skin or eyes
Keep the packaging closed when not in use
Safety informations :
- After contact with eyes, wash immediately with plenty of water
- If swallowed, vomit and seek medical advice
Pack Presentation
Product code: FINELEMC0019
Package size: 1 x 100 ml
Test Principle:
ISE method and manometric method
Composition :
Potassium chloride 7.64 mmol/L
Sodium chloride 356.09mmol/L
Calcium chloride 2.775 mmol/L
Lithium chloride < 1%
Deionized water 99%
Description :
Colorless and odorless solution
Handling precautions :
Avoid contact with skin or eyes
Keep the packaging closed when not in use
Safety informations :
- After contact with eyes, wash immediately with plenty of water
- If swallowed, vomit and seek medical advice
Pack Presentation
Product code: FINELEMC0016
Package size: Standard A 650ml, Standard B 350ml
Test Principle:
ISE method and manometric method
Composition :
Potassium chloride 7.64 mmol/L
Sodium chloride 356.09mmol/L
Calcium chloride 2.775 mmol/L
Deionized water 99%
Description :
Colorless and odorless solution
Handling precautions :
Avoid contact with skin or eyes
Keep the packaging closed when not in use
Safety informations :
- After contact with eyes, wash immediately with plenty of water
- If swallowed, vomit and seek medical advice
Pack Presentation
Product code: FINELEMC0014
Package size: Standard A 650ml, Standard B 350ml, Solution R 350 ml
Intended Use :
For calibrating stability of pressure sensor
Use for only with Erba Lyte Series
Test Principle:
ISE method and manometric method
Composition :
Potassium chloride 7.64 mmol/L
Sodium chloride 356.09mmol/L
Calcium chloride 2.775 mmol/L
Calcium acetate monohydrate 1.23 mmol/L
Deionized water 99%
Description :
Colorless and odorless solution
Handling precautions :
Avoid contact with skin or eyes
Keep the packaging closed when not in use
Safety informations :
- After contact with eyes, wash immediately with plenty of water
- If swallowed, vomit and seek medical advice
Pack Presentation
Product code: FINELEMC0015
Package size: Standard A 650ml, Standard B 350ml, Solution R 350 ml
Test Principle:
ISE method and manometric method
Composition :
Potassium chloride 7.64 mmol/L
Sodium chloride 356.09mmol/L
Calcium chloride 2.775 mmol/L
Calcium acetate monohydrate 1.23 mmol/L
Deionized water 99%
Description :
Colorless and odorless solution
Handling precautions :
Avoid contact with skin or eyes
Keep the packaging closed when not in use
Safety informations :
- After contact with eyes, wash immediately with plenty of water
- If swallowed, vomit and seek medical advice
Pack Presentation
Product code: FINELEMC0013
Package size: Standard A 650ml, Standard B 350ml
Test Principle:
ISE method and manometric method
Composition :
Potassium chloride 7.64 mmol/L
Sodium chloride 356.09mmol/L
Calcium chloride 2.775 mmol/L
Deionized water 99%
Description :
Colorless and odorless solution
Handling precautions :
Avoid contact with skin or eyes
Keep the packaging closed when not in use
Safety informations :
- After contact with eyes, wash immediately with plenty of water
- If swallowed, vomit and seek medical advice
Pack Presentation
Product code: Erba Lyte FINELEMC0011, Erba Lyte Plus FINELEMC0012
Package size: Standard A 650ml, Standard B 350ml
Test Principle:
Manometric method
Composition :
Organic buffer <0.10%
Inorganics salts <1.00%
Preservative <0.05%
Deionized water sq
Description :
Colorless and odorless solution
HCO3- : 30.0mmol/L
Handling precautions :
Avoid contact with skin or eyes
Keep the packaging closed when not in use
Safety informations :
- After contact with eyes, wash immediately with plenty of water
- If swallowed, vomit and seek medical advice
Pack Presentation
Product code: FINELEMC0004
Package size: 1 x 100 ml
Test Principle:
Ion Selective Electrode (ISE) technology.
Composition :
Organic buffer <0.10%
Inorganics salts <1.00%
Preservative <0.05%
Deionized water sq
Description :
Colorless and odorless solution
Handling precautions :
Avoid contact with skin or eyes
Keep the packaging closed when not in use
Safety informations :
- After contact with eyes, wash immediately with plenty of water
- If swallowed, vomit and seek medical advice
Pack Presentation
Product code: FINELEMC0017
Package size: 1 x 100 ml
Test Principle:
Ion Selective Electrode (ISE) technology.
Composition :
Organic buffer <0.1%
Tensioactive <1.0%
Preservative <0.05%
Deionized water sq
Description :
Colorless and odorless solution
Handling precautions :
Avoid contact with skin or eyes
Keep the packaging closed when not in use
Safety informations :
- After contact with eyes, wash immediately with plenty of water
- If swallowed, vomit and seek medical advice
Pack Presentation
Product code: FINELEMC0010
Package size: 1 x 100 ml
Test Principle:
Sodium hypochlorite solution can remove protein.
Composition :
Organic buffer <0.5%
Tensioactive <0.05%
Preservative <0.07%
Deionized water sq
Description :
Colorless solution
Handling precautions :
Avoid contact with skin or eyes
Keep the packaging closed when not in use
Safety informations :
- After contact with eyes, wash immediately with plenty of water
- If swallowed, vomit and seek medical advice
Pack Presentation
Product code: FINELEMC0003
Package size: 1 x 100 ml
Test Principle:
Sodium hypochlorite solution can remove protein.
Composition :
Dye <0.02%
Tensioactive <0.05%
Preservative <0.04%
Deionized water sq
Description :
Bule solution
Handling precautions :
Avoid contact with skin or eyes
Keep the packaging closed when not in use
Safety informations :
- After contact with eyes, wash immediately with plenty of water
- If swallowed, vomit and seek medical advice
Pack Presentation
Product code: FINELEMC0002
Package size: 1 x 100 ml
Note:
E:the electric potential of the electrode E0:the standard electric potential of the
electrode
n:the charge of measured ion R:gas constant (8.314 J/K.mol)
T:absolute temperature(273 + t℃) F:Faraday constant (96487 c/mol)
CX :the concentration of measured ion f X :the activity coefficient of measured ion
From Nernst equation, that under certain experiment conditions, the Logarithm of the ion
activity has a linear relation with the electrode potential (E). Electrolyte analyzer uses
“standard comparison” to measure the concentration of K ions, Na ions, chloride ions,
calcium ions and pH value in the sample. First measure the electrode potential of K+, Na+,
Cl-, Ca2+, and the pH in two known concentration of calibration liquid (drift correction fluid
and the slope of the calibration fluid) . Create a calibration curve in the machine, and then
measure the electrode potential of K+, Na+, Cl-, Ca2+ and pH in sample solution, obtain the
concentration of the ions from the calibration curve. The data will be displayed in the LCD
screen or print out by built-in printer.
2. Electrode performance
The K+, Cl -, Ca2+ Ion Selective Electrodes are PVC sensitive membrane electrodes with
special active material while the Na+, pH Ion Selective Electrodes are special glass
sensitive membrane electrodes. Below is the performance of K+, Na+, Cl -, Ca2+ and pH
electrodes:
Electrode K+ Na+ Cl- Ca++ pH
(std A mV)
(mmol/l)
Note: *the unit of pH is pH. The shelf life of Ref electrode is 360 days.
3. Maintenance
1. If the filling solution in some electrodes is sufficient, users can use the electrodes directly.
If not, Kindly refill the filling solution:Counterclockwise unscrewing Ag / AgCl internal
reference electrode, add the dedicated electrode filling solution with a syringe along the
inner cavity wall of the electrode. It is appropriate to add filling solution to 2/3 of total
volume. And then clockwise screw on the Ag / AgCl internal reference electrode, dry the
outer shell of electrode. Put the electrodes back to electrode chamber.
Note: Make sure to add the filling solution to the Ref electrode.
2. After using for a long time, the protein in the blood sample may be attracted to the
sensitive membrane or pipe of the electrode, therefore, it’s necessary to maintain with
de-proteinising solution.
3. When sensitive glass membrane of Na+ and pH electrode response slower or have
worse stability, use electrode conditioner to maintain. Note: This electrode conditioner
only work on glass membrane electrode, not the PVC membrane electrode!
4. The electrode storage requirements: all electrode should be stored in the dark under
5-25 °C.