33m box

402
375

375
Fig. Anchorage Details

Tendon force applied, Pu = 2343 kN


Design forces due to jacking = 2812 kN (Cl. 3.4.3.2)
Web inclination = 69.00 degree
Web thickness = 500 mm
Web height = 2300 mm
No of anchorages in web =4 nos.
C/C anchorage = 402 mm
< 2 aeff, closely spaced

Material details
Concrete details:
Concrete grade = M45
Reinforcement details:
Grade of reinforcement = Fe500
Stress in steel = 500 MPa

Prestressing strand details


Typical cable identification 19T15
Duct dia including sheathing = 107.00 mm
Width of anchorage plate = 250.00 mm
Depth of anchorage plate = 300.00 mm
Minimum clear cover = 75.00 mm
Clear distance between cables = 107.00 mm
Effective cover for anchorage = 235.00 mm
Effective depth of anchorage = 500.00 mm
Effective width of anchorage = 500.00 mm
Exit angle = 8.98 degree
Ultimate tensile strength f pk = 1860.00 MPa
Modulus of elasticity = 195.00 GPa

Local Zone Design


Width of local zone = 470 mm (Cl. 5.10.9.7.1)
Depth of local zone = 402 mm
Length of local zone = 705 mm
a) Bearing Resistance

Resistance factor, Φ = 0.70 (Cl. 5.5.4.2.1)


2
Gross area of the bearing plate, Ag = 75000 mm
Maximum loaded area, A = 200840 mm2
Net area of the bearing plate, Ab = 66008 mm2
Nominal concrete strength = 45 MPa
fn is the lesser of: a. 0.7 fci' √(A/Ag) = 52 MPa (Cl. 5.10.9.7.2-2)
b. 2.25 fci' = 101 MPa (Cl. 5.10.9.7.2-3)
Factored bearing resistance of anchorages = 2382 kN (Cl. 5.10.9.7.2-1)
Safe in bearing
General Zone Design
Width of general zone = 500 mm (Cl. 5.10.9.7.1)
Depth of anchorage zone = 2300 mm
Length of general zone = 3450 mm

a) Compressive force
Compression check of concrete compressive stresses is not required for basic anchorage (C5.10.9.6.2)
devices satisfying bearing resistance.

b) Bursting Resistance

402
a' = 102 mm
1.5 x a' = 153 mm
300 102 300 Design for single anchorage
Along web
Resistance factor, Φ = 0.90
Lateral dimension of anchorage device, a = 250 mm
Depth of the bursting zone, b = 402
Lateral dimension of in considered direction, h = 500 mm
Cable eccentricity =0 mm
Location of bursting force, dburst = 250 mm (Eq. 5.10.9.6.3-2)
Bursting force in anchorage zone, T burst = 571 kN OK
Stress in steel, fs = 140 MPa (Cl. 5.10.10.1)
Required area of steel, As = 4078 mm2 (Eq. 5.10.9.6.3-1)
Extent of bursting rebar, lc = 625 mm (C5.10.9.3.2-1)
Diameter of spirals bars = 16 mm
Pitch = 50 mm
Provided area of steel = 5027 mm2 OK
Diameter of spirals = 350 mm (C5.10.9.6.3-1)

c) Edge Tension Forces


0.4 x Depth of the section = 900 mm
Design for multiple Anchorage

Edge tension force = 703 kN


Area of steel required = 1406 mm2
Diameter of bars = 20 mm
Nos. =5 mm
Provided area of steel = 1571 mm2 OK

d) Spalling Resistance
Spalling force = 56 kN (Cl. 5.10.9.3.2)
Area of steel required = 112 mm2
Diameter of bars = 16 mm
Nos. =2 mm
Provided area of steel = 402 mm2 OK