Professional Documents
Culture Documents
402
375
375
Fig. Anchorage Details
Material details
Concrete details:
Concrete grade = M45
Reinforcement details:
Grade of reinforcement = Fe500
Stress in steel = 500 MPa
a) Compressive force
Compression check of concrete compressive stresses is not required for basic anchorage (C5.10.9.6.2)
devices satisfying bearing resistance.
b) Bursting Resistance
402
a' = 102 mm
1.5 x a' = 153 mm
300 102 300 Design for single anchorage
Along web
Resistance factor, Φ = 0.90
Lateral dimension of anchorage device, a = 250 mm
Depth of the bursting zone, b = 402
Lateral dimension of in considered direction, h = 500 mm
Cable eccentricity =0 mm
Location of bursting force, dburst = 250 mm (Eq. 5.10.9.6.3-2)
Bursting force in anchorage zone, T burst = 571 kN OK
Stress in steel, fs = 140 MPa (Cl. 5.10.10.1)
Required area of steel, As = 4078 mm2 (Eq. 5.10.9.6.3-1)
Extent of bursting rebar, lc = 625 mm (C5.10.9.3.2-1)
Diameter of spirals bars = 16 mm
Pitch = 50 mm
Provided area of steel = 5027 mm2 OK
Diameter of spirals = 350 mm (C5.10.9.6.3-1)
d) Spalling Resistance
Spalling force = 56 kN (Cl. 5.10.9.3.2)
Area of steel required = 112 mm2
Diameter of bars = 16 mm
Nos. =2 mm
Provided area of steel = 402 mm2 OK