You are on page 1of 58

Complete End To End

Industrial IoT,
Monitoring &
Control Solutions

Product
Application
Catalogue
Edition 1

No Prices
Region: Europe
Edition 1
Introduction

Energy Savings, Condition and Compliance Systems


Industrial Internet Of Things

Please note that there are three main components within


the systems that need to be chosen for each application:-

 Wireless RF transmitters manufactured with bespoke functionality


and often sensors around the application chosen.
RF

ULTRA RF
 Infrastructure - Internet, cellular RF Gateway – This device collects
GATEWAY data from the transmitters, stores into memory and transfers up to
the Realtime Online web server at regular intervals.
GPRS

realtime - online
www.realtime-online.com  Realtime Online, web based software that provides information
to the application, plus automated and on-demand reports, alarm
notifications, dashboard/information screen etc

2
Introduction

Flexible Expandable And Robust Realtime Monitoring

Choose your system


Invisible Systems design and manufacture wireless RF (Radio Frequency) communication devices and
Internet, cellular Gateways to provide data to their Realtime Online web server for Online monitoring
and Control.

A wide range of radio transmitters and tailored software enable monitoring and control for various
applications, such as:-

 Energy
 Compliance
 Food
 Pharma
 Healthcare
 Legionella
 Environmental
 Critical Asset
 Building Energy Management (BEMS)

This catalogue is designed to ease selecting the correct products and software for the application.

The catalogue is divided into the above three steps, in order to build your system:-

Step 1 – Choose the Internet, cellular RF gateway, there are various types dependent upon the site and
individual choice plus accessories , antennas and repeaters.

Step 2 – Select the section relevant to your application

Step 3 – Multiple ‘applications’ can be consolidated within a single system, for example you may start
with ‘Food Compliance’ then wish to add Energy Monitoring, this is common and the way the
system has been designed, the same ‘Infrastructure Gateway’ can communicate to any type of
RF transmitting device and software application modules can be added retrospectively.

Confidential Document, not for re-distribution or copying of any


content without express permission from Invisible Systems Limited

V4.0 - 2018

3
Introduction

How it works

 RF Transmitters connect to sensors or meters and send data to the Infrastructure Internet
connected Gateway on the site.

 The Gateway stores and transfers the data to the Realtime Online web server over a
secure, mobile cellular connection.

 Realtime Online provides a web portal of visualisation dashboards, reports, graphs and
transmits out tailored automated reports and notifications in the event of exceptions.

4
Realtime-OnlineTM

Solutions & Applications

 A single system with software modules tailored to applications

 Realtime Monitoring and Control

 Accessible from internet connected devices anywhere in the world

5
Realtime-OnlineTM

Visualisation Software
Realtime Online is a web based software that displays information gathered by the range of Invisible
Systems radio frequency transmitters.
A general purpose portal for various, distinctively different applications.
A major differentiator of the Invisible Systems and Realtime Online integrated solution compared to
other products is that with one ‘System’ there are many different applications that can be monitored and
controlled.
This results in a flexible product, for example, initially purchased for one purpose, then extended for
additional purposes without the cost duplicating infrastructures and additional software packages.
Tailored Software Applications:-

 Energy
 Monitoring
 Control
 Compliance
 Food
 Pharmaceutical
 Healthcare
 Legionella
 Critical Asset Monitoring
 High Voltage/Sub station
 Rail
 Generator Monitoring
 Environmental
 Weather
 Lightening
 Flood
 Water
Software modules tailored to a range of applications with bespoke:

 Dashboards
 Graphical analytical tools
 On-demand reports
 Automated emailed reports
 Notifications of exceptions by email and/or text message
 Instant Remote Control
 Scheduled and set point control for Heating and cooling
 Scheduled lighting, plant etc control
Tailored software suites have been designed specifically around the needs of a user for a particular use,
for example a Food Manufacturer, bespoke dashboards showing Realtime temperatures for maintenance
or technical staff, on-demand and automatically emailed HACCP reports for temperature compliance,
alarm notifications after a temperature exception has been maintained for an excessive period by email

6
Table of Contents

Starter Kits
Starter Kits 8 - 11

Infrastructure
Infrastructure 12 - 16

Energy
Energy 17 - 25

Compliance
Compliance 26 - 38
Food Pharmaceutical Healthcare Legionella

Industrial IoT
Condition &
Critical Asset Monitoring 39 - 41
& Industrial IoT

Environmental
Environmental 42 - 47
Weather Station Sensors Water

LoRaWAN
LoRaWAN 48 - 50 SmartBUS RF

SmartBUS RF 51
Accessories

Tools & Accessories 52 - 55

7
Starter Kits
Starter Kits

Starter Kit Data Centre Monitoring

Contains:
1x LoRa RF M2M GPRS Gateway,
1x 3 Phase Wireless Meter & CTs
(Current Transformer),
2x Tx-ULTRA RF Temperature, Boxed
1x Dual Status with reed switch,
Antennas, power connection & cables.

Pre-Configured realtime-onlineTM: Product No.: 3999-905-1001-A


Web-Based monitoring reporting
Alarms by Email (Mobile Text Option)
Temperature, Door Status & Energy Profiling
* 3 Month subscription included

Starter Kit Office Environment & Commercial Building Monitoring


Contains:
1x LoRa RF M2M GPRS Gateway,
1x 3 Phase Wireless Meter & CTs
(Current Transformer),
2x Tx-ULTRA RF Temperature,
Air Humidity and CO2 Sensors, Alarmed
1x Dual Alarm Status (no reed Switch),
Antennas, power connection & cables.

Product No.: 3999-905-1002-A Pre-Configured realtime-onlineTM:


Web-Based monitoring reporting
Alarms by Email (Mobile Text Option)
Temperature, Door Status & Energy Profiling
* 3 Month subscription included

8
Starter Kits

Starter Kits
Starter Kit Food Safety Compliance & Energy Monitoring

Contains:
1x LoRa RF M2M GPRS Gateway,
1x 3 Phase Wireless Meter & CTs
(Current Transformer),
2x ULTRA RF Temperature Sensor
with cable and probe,
1x Door Status Sensor &
Magnetic Reed Switch,
Antennas, power connection & cables.

Pre-Configured realtime-onlineTM: Product No.: 3999-905-1003-A


Web-Based HACCP reporting
Alarms by Email (Mobile Text Option)
Temperature, Door Status & Energy Profiling
* 3 Month subscription included

Starter Kit Healthcare & Carehomes

Contains:
1x LoRa RF M2M GPRS Gateway,
3x ULTRA RF Single Temperature
min / max probes,
1x Humidity & Temperature Sensor,
Antennas, power connection,
cables & probes.

Product No.: 3999-905-1004-A Pre-Configured realtime-onlineTM:


Web-Based HACCP reporting
Alarms by Email (Mobile Text Option)
Temperature, Air Quality & Legionella compliance.
*3 Month subscription included

9
Starter Kits
Starter Kits

Starter Kit Industrial IoT Monitoring


Contains:
1x LoRa RF 2G Indoor Gateway,
1x LoRa RF Indoor Optical Pulse Transmitter,
1x LoRa RF sensor and transmitter 2m PTFE Cable,
1x Ultra RF Vibration (0-2g) Single Channel TX,
1x LoRa RF Indoor Wireless Energy Meter (3 Inputs),
3x Split Core CT’s 400Amp
Antennas, power connection & cables.

Pre-Configured realtime-onlineTM: Product No.: 3999-905-1005-A


Web-Based monitoring reporting
Alarms by Email (Mobile Text Option)
Temperature, Vibration, Status & Energy Profiling
* 3 Month subscription included

Portable Trial Demo Kit


Contains:
1 x boxed ISL 058 Gateway
3 x 3ph Wireless Meters
Range of CT's
Range of Pulse Transmitters
2 x Shield Transmitters
1 x Dual min/max Transmitter
1 x Repeater Transmitter
1 x Pulse Splitter
1 x Chatterbox
Stored in a robust case

Pre-Configured realtime-onlineTM:
Web-Based monitoring reporting
Alarms by Email (Mobile Text Option)
Product No.: 3999-905-1007-A
Temperature, Status & Energy Profiling
* 3 Month subscription included

10
Starter Kits

Starter Kits
Starter Kit LoRaWAN
Contains:
1x LoRaWAN Door & Window Sensor
1x LoRaWan Indoor Air Quality Sensor
1x LoRaWAN Asset Tracker
1x LoRaWAN Configurable Push Button
2x LoRaWAN Temperature & Humidity Sensor

Pre-Configured realtime-onlineTM: Product No.: 3999-905-1006-A


Web-Based monitoring reporting,
Alarms by Email (Mobile Text Option)
Temperature, Tracker Status, Air Quality & Window Status.
* 3 Month subscription included

11
Infrastructure

The Invisible Systems Infrastructure is designed to be secure, simple and reliable


The infrastructure includes a range of products and sensors connected by point to point communication
protocol, the simplest and most straightforward, to the system Gateway using long range Radio
Frequency (RF) transmitters. Sensors are generally battery powered and with unique firmware limiting
Infrastructure

connections, battery life is increased to typically greater than 5 years.


A single Gateway installed on site provides connection to

{ DIRECT LINE OF SIGHT,


SENSORS CAN
CONNECT UP TO 15KM } a range of sensors, up to 200, which in turn transmits over
mobile cellular connection to the Realtime-Online cloud
server and visualisation software. More Gateways can be
added to extend the system and range.
A single Gateway installed on site provides connection to all in range sensors, up to 100, which in turn
transmits over mobile cellular connection to the Realtime-Online cloud server and visualisation software.
More Gateways can be added to extend the system and range.

Features Benefits
Secure and robust infrastructure Simple Installation

Battery operated sensors Easy to expand and adapt

Long Range RF Cost Effective Solution

Standalone Communication Non Intrusive System

Gateway

12
Infrastructure

Gateway
The range of gateways "listen" to the transmitters over RF and buffer into memory sending the received
data over a mobile, cellular VPN (secure virtual private network), to the Realtime Online server for
reporting. The mobile, cellular connectivity is via an embedded roaming SIM card.
Radio repeaters extend the RF messages from transmitters positioned in areas that are out of RF range of

Infrastructure
the gateway.
Gateways are provided in a range of options to suit the

{ }
GATEWAYS CAN BE
application and environment as detailed below. These
REMOTELY CONFIGURED TO
include, standard unit with external power supply; IP65
ALLOW FOR DIAGNOSTICS enclosure type with internal power supply plus optional
AND UPDATES battery backup.

Part No. Description Image


3999-902-1421-A LoRa RF 2G Indoor Gateway
Dimensions (HxWxD) 10cm x 9cm x 4cm supplied with:
• Roaming Sim Card
• Antennas - Height: 21cm
• External Power Supply

3999-902-1422-A LoRa RF 2G Outdoor Gateway


Dimensions (HxWxD) 25cm x 20cm x 10cm supplied with:
• Roaming Sim Card
• Antennas - Height: 21cm
• Internal Power Supply
• IP65 Enclosure

3999-902-1433-A LoRa RF 2G Outdoor Gateway


Dimensions (HxWxD) 25cm x 20cm x 10cm supplied with:
• Roaming Sim Card
• Antennas - Height: 21cm
• Internal Power Supply
• IP65 Enclosure
• Battery Backup

LoRa RF 2G Outdoor Gateway - Hybrid


Dimensions (HxWxD) 25cm x 20cm x 10cm supplied with:
• Roaming Sim Card
• Antennas - Height: 21cm
• Internal Power Supply
• IP65 Enclosure
3999-902-1432-A • Legacy 868MHz RF Radio
3999-902-1449 • Legacy 433MHz RF Radio

13
Infrastructure

Gateway
Part No Description Image
3999-902-1443-A LoRa RF 2G Indoor Gateway
• LoRa RF Rx
Infrastructure

• RS485 Comms
• 8 x Digital Input
• 4x Digital Output
• 4 x Digital Input
• 4 x 0-10V Input
• 4 x 20mA Input

3999-902-1444-A LoRa RF 2G Outdoor Gateway


• LoRa RF Rx
• RS485 Comms
• 8 x Digital Input
• 4x Digital Output
• 4 x Digital Input
• 4 x 0-10V Input
• 4 x 20mA Input
• Internal Power Supply
• IP65 Enclosure
3999-902-1451-A LoRa RF Ethernet Indoor Gateway
• LoRa RF Rx
• RS485 Comms
• SmartBUS

3999-902-1450-A LoRa RF Ethernet Outdoor Gateway


• LoRa RF Rx
• RS485 Comms
• SmartBUS
• Internal Power Supply
• IP65 Enclosure

3999-901-1212-A Indoor Radio Repeater LoRa RF Rx/Tx supplied with:


• Plug top power supply
• Integrated Antenna

14
Infrastructure

Realtime-OnlineTM
Part No Description
Activation
996-510-3204-D Realtime Online-Activation fee for 1 points

Infrastructure
996-510-3205-D Realtime Online-Activation fee for 2-5 points
996-510-3206-D Realtime Online-Activation fee for 6-10 points
996-510-3207-D Realtime Online-Activation fee for 11-20 points
996-510-3208-D Realtime Online-Activation fee for 21-50 points
996-510-3209-D Realtime Online-Activation fee for 51-100 points
996-510-3210-D Realtime Online-Activation fee for 101-200 points
996-510-3211-D Realtime Online-Activation fee for 201+ points
996-510-3231-D Realtime Online-Activation fee for Boiler Control per system
Realtime Online Annual
996-210-3214-D Realtime Online reporting - 1 monitoring points (Tx only) incl data
996-210-3215-D Realtime Online reporting - 2-5 monitoring points (Tx only) incl data
996-210-3216-D Realtime Online reporting - 6-10 monitoring points (Tx only) incl data
996-210-3217-D Realtime Online reporting - 11-20 monitoring points (Tx only) incl data
996-210-3218-D Realtime Online reporting - 21-50 monitoring points (Tx only) incl data
996-210-3219-D Realtime Online reporting - 51-100 monitoring points (Tx only) incl data
996-210-3220-D Realtime Online reporting - 101-200 monitoring points (Tx only) incl data
996-210-3221-D Realtime Online reporting - 200+ monitoring points (Tx only) incl data
API & CSV Export Services
996-510-2025-N CSV data export - 1-25 monitoring point
996-510-2026-N CSV data export - 26-50 monitoring points
996-510-2027-N CSV data export - 51-100 monitoring points
996-510-2028-N CSV data export - 101-200 monitoring points
996-510-2029-N CSV data export - 201-350 monitoring points
996-510-2030-N CSV data export - 351-500 monitoring points
Alerts and Data Sims
996-510-1100 SMS Alerts (100 Alerts)
996-510-3223 Text to Speech Alerts (600 Credits - 3 Credits used per message)
888-830-0060 UK/Europe Data Sim
888-830-0058 Australia Data Sim
888-830-0061 US and Canada Data Sim - Kore
Network Server Software
996-500-0112 Network Server Software 0 - 100 points
996-500-0113 Network Server Software 100 - 500 points
996-500-0114 Network Server Software 501 - 1000 points
996-500-0115 Network Server Software 1001 - 5000 points
996-500-0116 Network Server Software 5001 - 10000 points
996-500-0117 Network Server Software 10000+ points

15
Infrastructure

Application Type
Realtime-OnlineTM Versatile Application Software
The Realtime-Online software application offers the opportunity to profile, benchmark and configure
thresholds for expected energy consumption. Where thresholds are exceeded Realtime Online generates
email or sms alerts to a user configurable contact set to prompt corrective action.
Infrastructure

Mixed Energy Dashboard Condition Dashboard

Dashboard Graph Compliance Fridge Report

Analytical Budget vs Actual Display Screen

16
Energy

Energy Transmitters
Energy or utilities can monitored in various ways and the consumption
data is collected and transmitted by an LoRa RF Transmitter to the
Gateway and onto Realtime Online.
The transmitters are available in various forms, from counting pulses
(flashing LEDs) from an existing or secondary pulsed output meter, a
wireless meter where CTs are clamped over cables, a modbus meter or
network whereby meter registers are read and transmitted.
*Wireless meters use a range of voltage CT’s to suit the required
current of the load to be monitored, (not included in the price).
See next section for range and part numbers

Part No Description Image

Energy
3999-913-2089-A LoRa RF Indoor Pulse transmitter
• Single Input (1 Channel)
• 2m PVC Cable

3999-913-2227-A LoRa RF Indoor Pulse transmitter


• Dual input (2 channel)
• 2m PVC Cable

3999-913-2143-A LoRa RF Indoor Optical Pulse Transmitter


• Optical LED Pulse reader
• 2m PVC Cable

3999-940-9541-A *LoRa RF Indoor Wireless Energy Meter (Single


Input)
• 1 Phase - Accuracy ±(10%)

3999-940-9542-A *LoRa RF Indoor Wireless Energy Meter (3


inputs - can be 3ph or 3 x 1ph circuit)
• 3 Phase - Accuracy ±(10%)

3999-913-2188-A LoRa RF Modbus Transmitter (Boxed with


Transmitter and
Power Supply Unit)
• Mains Powered
• 2m PVC Cable

17
Energy
Panel Meters - 1 Phase
The systems integrates power measurement and RF communications in a single, flexible unit which can
be tailored to suit a variety of energy monitoring, and management installations. The panels have
integrated wireless communication, Pulse or Modbus. Power quality monitoring is provided by MODBUS
registers being communicated and displayed on Realtime Online™.

Data is reliably transmitted via mobile (GPRS) cellular communications, via a system Gateway (see
Gateway options page) and viewed using Realtime Online. Meter Panels can be provided with built in
Gateway, please call for details and prices.
Features:
 Hardware configuration or via plug and socket arrangement
 Class 1 (±1%) accuracy (MID Option available - Please call for details)
Energy

Part No Description Image


999-940-9589-B LoRa RF Wireless Single Phase
Energy Meter
• Pulse Transmitter
• kWh

999-940-9582-B LoRa RF Wireless Single Phase


Energy meter
• Modbus Transmitter
• Volts, Amps, kW, kWh

999-940-9583-B LoRa RF Wireless Single MID


Phase Energy meter
• Modbus Transmitter
• Volts, Amps, kW, kWh

999-940-9585-B PV Generation Monitoring (DC Meter)


LoRa RF Wireless Single Phase
Energy meter
• Pulse Transmitter
• Max 20A (direct connected)
Higher current, shunt required
3999-940-9586-B 50 Amp CT
3999-940-9587-B 100 Amp CT
3999-940-9588-B 300 Amp CT

3999-940-9584-B Portable Appliance Monitor


LoRa RF Wireless Single Phase
Energy Meter
Dimensions (HxWxD cm)
25 x 13 x 13
• 13Amp Socket

18
Energy
Panel Meters - 3 Phase
The system integrates power measurements and communications in a single, flexible unit which can be
tailored to suit a variety of energy monitoring and management installations. The panels have integrated
wireless communication, Pulse or Modbus. Power quality monitoring is provided by MODBUS registers
being communicated and displayed on Realtime Online™.
Data is reliably transmitted via mobile (GPRS) cellular communications, via a system Gateway (see
Gateway options page) and viewed using Realtime Online. Panels can be provided with optional built in
Gateway, please call for details and prices.
Features:
 Connect up to 6 three phase circuits or up to 6 single phase circuits (or combination)
 Split Core CT's ease of installations avoiding interruption to power supply (not included)
 Class 1 (1%) accuracy (MID Option available – Please call for details)

Energy
Part No Description Image
3999-940-9455-B LoRa RF Pulse 1x3ph Panel
Meter Dimensions (HxWxD mm)
190 x 140 x 140mm
• 1 x 3ph circuits
• Pulse Transmitter
3999-940-9456-B LoRa RF Pulse 2x3ph Panel
Meter Dimensions (HxWxD mm)
240 x 190 x 155mm
• 2 x 3ph circuits
• Pulse Transmitter
3999-940-9535-B LoRa RF Modbus 1x3ph Panel
Meter Dimensions (HxWxD mm)
240 x 190 x 155mm
• 1 x 3ph circuits
• Modbus Transmitter
3999-940-9591-B MID 1 x 3 phase
Dual tariff modbus panel meter
3999-940-9536-B LoRa RF Modbus 2x3ph Panel
Meter Dimensions (HxWxD mm)
240 x 190 x 155mm
• 2 x 3ph circuits
• Modbus Transmitter
3999-940-9594-B MID 2 x 3 phase
Dual tariff modbus panel meter
3999-940-9537-B LoRa RF Modbus 3x3ph Panel
Meter Dimensions (HxWxD mm)
300 x 220 x 180mm
• 3 x 3ph circuits
• Modbus Transmitter
3999-940-9593-B MID 3 x 3 phase
Dual tariff modbus panel meter

19
Energy

Panel Meters - 3 Phase

Part No Description Image


3999-940-9538-B LoRa RF Modbus 4x3ph Panel
Meter Dimensions (HxWxD mm)
190 x 140 x 140mm
• 4 x 3ph circuits
• Modbus Transmitter

3999-940-9595-B MID 4 x 3 phase


Energy

Dual tariff modbus panel meter

3999-940-9539-B LoRa RF Modbus 5x3ph Panel


Meter Dimensions (HxWxD mm)
240 x 190 x 155mm
• 5 x 3ph circuits
• Pulse Transmitter
3999-940-9596-B MID 5 x 3 phase
Dual tariff modbus panel meter

3999-940-9540-B LoRa RF Modbus 6x3ph Panel


Meter Dimensions (HxWxD mm)
240 x 190 x 155mm
• 6 x 3ph circuits
• Modbus Transmitter
3999-940-9597-B MID 6 x 3 phase
Dual tariff modbus panel meter

3999-940-9579-B LoRa RF Single Panel Meter


Dual energy meter, built-in
key-pad and LCD data display
• 2 x 3ph
• 6 x 1ph
• Modbus Transmitter
Requires set of CT's with interface
(see below).

Set of 3 Split Core CT's


with interface for use with
3999-940-9579

600-601-3080-B • 60A
600-601-3081-B • 100A
600-601-3055 • 200A
600-601-3056 • 400A

20
Energy

Distribution Board Monitoring


The Invisible Systems multi-channel sub meter, monitors consumption on individual branch circuits
within, for example, mains distribution boards, Data Centers, Load management and MCC’s. The Sub
Channel meter provides snapshots of the facility’s energy use from a single device all the way up to an
entire building.
The unit comprises of a single device with current sensor (CT’s not included) and Modbus RS485
communication with 2 configurable options.
The system integrates power measurement and communications in a single, flexible unit which can be
tailored to suit a variety of energy monitoring and management installations.

Part No Description Image

Energy
3999-940-9577-B 21 Channel Sub Meter Din Rail
• 7 x 3ph or 21 x 1ph
• kW and Current

3999-940-9581-B 21 Channel Sub Meter


Dimensions (HxWxD mm)
270 x 215 x 100mm
• 7 x 3ph or 21 x 1ph
• kW and Current
• Modbus Transmitter

3999-940-9591-B vDimensions (HxWxD mm)


285 x 340 x 100mm
• 14 x 3ph or 42 x 1ph
• kW and Current
• Modbus Transmitter

21
Energy
Split Core CT's
The Invisible Systems Voltage CT is a cost effective split core design providing safer and easier
installation, not requiring any circuits disconnection. It has a wide application and measures AC current
flow. Supplied as standard with a jack plug for use with our range of Wireless Meters.
Please see Split Core Data sheet for full specification
Compatible with:
 Wireless Meters
 Panel Meters
 Modular Meters
Energy

Part No Description Image


600-601-3059-A 5 AMP 0.33VAC split core CT
6-mm window

600-601-3049-A 10 AMP 0.33VAC split core CT


10-mm window

600-601-3050-A 30 AMP 0.33VAC split core CT


10-mm window

600-601-3058-A 50 AMP 0.33VAC split core CT


19-mm window

600-601-3051-A 100 AMP 0.33VAC split core CT


16-mm window

600-601-3054-A 100 AMP 0.33VAC split core CT


19-mm window

600-601-3055-A 200 AMP 0.33VAC split core CT


19-mm window

600-601-3056-A 400 AMP 0.33VAC split core CT


32-mm window

600-601-3057-A 800 AMP 0.33VAC split core CT


52-mm window

600-601-3060-A 1000 AMP 0.33VAC split core CT


52- mm window

22
Energy
Flexible CT's - Rogowski
Where access or space is restricted, the Rogowski flexible CT should be selected. Designed to measure
up to 2,000 Amps of AC current, the flexible core coil opens at the connector junction so it can be easily
installed on a busbar or existing cable. The design of this flexible rope CT is that of a 'tear drop' shape,
which makes it easy to install where there is only limited space, such as in electrical panels.
The CT’s come with an integrator which needs a power supply (12v to 30v AC or DC), not included.
See accessories

Part No Description Image


600-601-3067-A 50 AMP Rogowski Flexible CT
0.33VAC output with Integrator

Energy
600-601-3068-A 100 AMP Rogowski Flexible CT
0.33VAC output with Integrator

600-601-3061-A 400 AMP Rogowski Flexible CT


0.33VAC output with Integrator

600-601-3069-A 800 AMP Rogowski Flexible CT


0.33VAC output with Integrator

600-601-3070-A 1000 AMP Rogowski Flexible CT


0.33VAC output with Integrator

600-601-3071-A 2000 AMP Rogowski Flexible CT


0.33VAC output with Integrator

200-365-8037-B Metering - Flexible CT


Power Supply
• Rogowski PSU 30w 12v

23
Energy
Heat and Flow Meters
Invisible Systems heat metering is designed to provide monitoring as
required in relation to the Heat Network (Metering and Billing)
Regulations 2014 which implement the requirements in the EU
Energy Efficiency Directive (EED), as they apply for heating and cooling.

The Invisible Systems new thermal, heat, ow/energy metering solution


is a simple, low cost, hot or chilled water energy management using
simple clamp on LoRasonic devices, with pulse output or Modbus
communication and displayed on Realtime-Online™

Part No Description Image


Energy

600-630-6323-B Flow meter - U1000


• Pipe diameter 25-115mm
• Min 20mm ID
• Flow range 0.1m/s-10m/s
• Output Pulse
See P/N 3999-913-2089 for Tx (Page 17)

600-630-6362-B Heat meter - U1000 HM


• Pipe diameter 25-115mm
• Min 20mm ID
• Flow range 0.1m/s-10m/s
• Output Modbus
See P/N 3999-913-2188 for Tx (Page 17)

600-630-6363-B Heat Meter Probes


Flow and Return Temperature

600-620-6302-B Flow Meter - U3000


• Pipe diameter 13-2000mm
• Flow range 0.1m/s-20m/s
• Guide Rail
• Sensors and Cables & clamps
See P/N 3999-913-2188 for Tx (Page 17)

600-620-6302-B Heat Meter – Calec ST II


Energy calculator for use with
Flow meter U3000 above to provide heat meter func-
tionality
• PT100 sensors
• Output Modbus
See P/N 3999-913-2188 for Tx (Page 17)

24
Energy
Metering Accessories
To facilitate connections that are often required when monitoring energy and utilities, below are a
selection of common accessories.
Hi Gain Antenna’s are desirable when either GSM cellular signal and/or RF signals are low.

Where existing sensors or metering is already connected to a system, eg BMS, interface splitters will be
needed. For gas meter or hazardous area connections to non-hazardous equipment, a Chatterbox will be
required.

Part No Description Image


600-610-6185-B Metering - Pulse Splitter

Energy
passive design, no batteries or
Power Supply Unit required
• 1 input, 3 outputs

999-950-9503-B Metering - Chatterbox (Gas Meters) Intrinsic Barrier


for hazardous areas
• 4 input channels

999-950-9584-B Metering Chatterbox (Gas) Intrinsic Barrier Single


Output
• Ensures Compliance to ATEX Directives
• Battery Powered
• 5 year battery power

220-210-2371-B Metering - CT Extension Lead


Cable
• DC Extension 2.5mm x 3M

200-365-8037-B Metering - Flexible CT Power Supply


• Rogowski PSU 30w 12v

130-440-4424-A Gateway - Hi Gain Antenna (GSM)


• 5db Antenna c/w 3M RG58

130-440-4438-A Gateway - Hi Gain Antenna (RF)


• SMA 5dbi Mag Whip Antenna
• 1m cable

130-440-4442-A Gateway - Hi Gain Antenna (RF)


• SMA 5dbi Wall Mount dipole
• 1m cable

25
Compliance

Realtime-OnlineTM
Compliance

26
Compliance

Compliance Table of Content

Food Compliance 28 - 30

Compliance
Pharmaceutical/Medical 31 - 34

Healthcare 35 - 37

Legionella 38

27
Compliance
Food Compliance
Temperature and condition monitoring is an important requirement
for the food industry and for compliance to meet requirements of BRC
Global Standard for Food Safety and HACCP, for example.
Where temperatures need to be measured and recorded for such
compliance, Invisible Systems provide RF Wireless sensors specifically
designed to monitor temperatures of refrigerated areas, freezers and
cold stores.
Sensors can communicate to an optional local audible alarm display to
notify site personnel.

Part No Description Image


LoRa RF Boxed sensor range (room)
• Temperature
3999-913-2196-A Internal Antenna
3999-913-2205-A External Antenna
3999-913-2211-A *Alarmed – Internal Antenna
Compliance

3999-913-2215-A *Alarmed – External Antenna

LoRa RF Boxed sensor range (room)


• Temperature
• Humidity
3999-913-2197-A Internal Antenna
3999-913-2206-A External Antenna
3999-913-2212-A *Alarmed – Internal Antenna
3999-913-2216-A *Alarmed – External Antenna

3999-913-2249-A LoRa RF In Vehicle Temperature


Monitoring Interface
• RF/Bluetooth Interface
• Google Mobile App
(Transmitters not included)

3999-902-1427-A *LoRa RF Alarm Display


• Built in RF Transmitter
• 12v Plug Top Power Supply

3999-913-2252-B Multi Input Channel Temperature Logger


• 12 Channel
• Suitable for PT100

*Temp Alarm configured at time of ordering

28
Compliance
Food Compliance
Part No Description Image
3999-913-2156-A LoRa RF sensor and transmitter
3999-913-2230-A Indoor/ Outdoor Shield Radiation Tube
3999-913-2220-A (-55°C/+85°C)
3999-913-2128-A • Standard Temperature
• Alarmed Temperature
• Memory Temperature
Outdoor Ambient Temp IP Case
(Memory and Alarmed Options)

3999-913-2103-A LoRa RF sensor and transmitter


3999-913-2200-A 2m Flat PVC Cable (-55°C/+85°C)
3999-913-2219-A • Standard Temperature
• Alarmed Temperature
• Memory Temperature

Compliance
3999-913-2184-A LoRa RF sensor and transmitter
3999-913-2208-A 2m PTFE Cable (-55°C/+85°C)
3999-913-2218-A • Standard Temperature
• Alarmed Temperature
• Memory Temperature
3999-913-2251-A LoRa RF sensor and transmitter
• PT100 Mk2 Temperature (-100°C/+230°C)
• 2M PTFE Cable

3999-913-2108-A LoRa RF Status Transmitter


• Single Input c/w Magnetic Read Switch

3999-913-2186-A LoRa RF sensor and transmitter


3999-913-2209-A Temperature (-55°C/+85°C)
3999-913-2187-A c/w Magnetic Switch
3999-913-2210-A • 2M PVC Cable
• 2M PVC cable Alarmed
• 2M PTFE Cable
• 2M PTFE cable Alarmed

3999-913-2253-A LoRa RF sensor and transmitter


• PT100 Mk2 Temperature (-100°C/+230°C)
• 2M PTFE Cable
• Magnetic switch

29
Compliance
Food Compliance
Part No Description Image
ge
3999-913-2231-A LoRa RF pointed probe and transmitter
• Temperature (-25°C/+85°C)
• 2M PVC Cable

3999-913-2255-A LoRa RF Temperature &


Humidity on flying lead
• Temperature range & accuracy
• Humidity range & accuracy
Compliance

3999-913-2225-A LoRa RF Dual Sensor


(-55C / +85C) on 2m PVC / PTFE cable
• Fridge / Freezer Temperature

3999-913-2261-B LoRa RF Oxygen Depletion Transmitter (0-25 %)


• General Accuracy: +/-2% of Range
• Temperature: -5 to 55 Deg C
• Humidity: 5-95% RH Non-Condensing
• Oxygen Range: 0-25% Volume
• Sensor Life: up to 5 years

3999-913-2270-B ISL Refrigeration Monitor


Cold Drinks & Ice Cream fridges
• Temperature too High / Low
• Doors open too long
• Excessive vibration
• Location change (by GSM or GPS)
• Power Loss
• Optional temperature & door sensors

30
Compliance
Pharmaceutical/Medical
Temperature and condition monitoring is an important requirement
for the pharmaceutical /medical application for compliance. Such as
21CFR etc.
Invisible Systems have products to monitor refrigerated areas, freezers
down to -80C and even -200C for liquid nitrogen, doors being closed
etc and reporting software with specific for this application. Positive
and/or negative room pressures can be continuously monitored for
traceability and alarms raised in the event of a failure.
The wireless transmitters can communicate to a local audible, alarm
display to notify personnel locally in the event of an exception.

Part No Description Image


LoRa RF Boxed transmitter (room)
• Temperature
3999-913-2196-A Internal Antenna
3999-913-2205-A External Antenna

Compliance
3999-913-2211-A *Alarmed – Internal Antenna
3999-913-2215-A *Alarmed – External Antenna
LoRa RF Boxed transmitter (room)
• Temperature
• Humidity
3999-913-2197-A Internal Antenna
3999-913-2206-A External Antenna
3999-913-2212-A *Alarmed – Internal Antenna
3999-913-2216-A *Alarmed – External Antenna

3999-913-2255-A LoRa RF Temperature & Humidity on flying lead


• Temperature range & accuracy
• Humidity range & accuracy

LoRa RF Boxed transmitter (room)


• Temperature
• Humidity
• CO2 (0-5000ppm)

3999-913-2198-A Internal Antenna


3999-913-2207-A External Antenna
3999-913-2213-A *Alarmed – Internal Antenna
3999-913-2217-A *Alarmed – External Antenna
N/A Beverage Meter
• Low cost
• PVDF body
• Sapphire bearings
• Hall effect sensor
• Viton seal as standard

*Temp Alarm configured at time of ordering


31
Compliance
Pharmaceutical/Medical
Part No Description Image
LoRa RF Boxed transmitter (incubator)
• CO2 (0-20%)
• mains powered

3999-913-2201-A Internal Antenna


3999-913-2214-A External Antenna
3999-913-2238-A *Alarmed – Internal Antenna
3999-913-2239-A *Alarmed – External Antenna

LoRa RF Boxed transmitter (room)


• CO2 (0-5000ppm)
• Optional: Temperature & Humidity probe on flying
lead.
Compliance

3999-913-2203-A Internal Antenna


3999-913-2229-A External Antenna

3999-902-1427-A LoRa RF Alarm Display


• Built in RF Transmitter
• 12v Plug Top Power Supply

3999-913-2252-B Multi Input Channel Temperature Logger


• 12 Channel
• Suitable for PT100

3999-913-2261-B Ultra RF Oxygen Depletion Transmitter (0-25 %)


• General Accuracy: +/-2% of Range
• Temperature: -5 to 55 Deg C
• Humidity: 5-95% RH Non-Condensing
• Oxygen Range: 0-25% Volume
• Sensor Life: up to 5 years

32
Compliance
Pharmaceutical/Medical
Part No Description Image
LoRa RF Temperature transmitter
Shield Radiation Tube (-55°C/+85°C)

3999-913-2156-A • Standard Temperature


3999-913-2230-A • Alarmed Temperature
3999-913-2220-A • Memory Temperature

LoRa RF Temperature transmitter


2m Flat PVC Cable (-55°C/+85°C)

3999-913-2103-A • Standard Temperature


3999-913-2200-A • Alarmed Temperature
3999-913-2219-A • Memory Temperature

Compliance
LoRa RF Temperature transmitter
2m PTFE Cable (-55°C/+85°C)
3999-913-2184-A • Standard Temperature
3999-913-2208-A • Alarmed Temperature
3999-913-2218-A • Memory Temperature

3999-913-2226-A LoRa RF Temperature transmitter


• PT100 Temperature measurement
range (-100°C/+230°C)
• 2M PTFE Cable

3999-913-2254-A LoRa RF Temperatuer transmitter


• PT100 measurement range (-196°C/+100°C)
• 2m PTFE Cryogenic Probe
• Mineral Insulated 500mm probe

LoRa RF Transmitter with


Temperature (-55°C/+85°C)
c/w Magnetic Switch
3999-913-2186-A • 2M PVC Cable
3999-913-2209-A • 2M PVC cable Alarmed
3999-913-2187-A • 2M PTFE Cable
3999-913-2210-A • 2M PTFE cable Alarmed
3999-913-2253-A LoRa RF Temperature transmitter
• PT100 Temperature MK2 (-100°C/+230°C)
• 2M PVC Cable
• Magnetic switch

33
Compliance
Pharmaceutical/Medical
Part No Description Image
3999-913-2234-A Mobile Compliance Monitor Kit
• RF/Bluetooth Interface
• Android Device
• Google Mobile App
• RF Temperature Sensors (optional)

3999-913-2269-B ISL Refrigeration Monitor


Laboratories & Life Science
• Temperature too High / Low
• Doors open too long
• Excessive vibration
• Power Loss
Compliance

• One temperature probe included

3999-913-2233-B Wireless Pressure Differential Transmitter c/w LCD


Backlit Display
• Cleaning rooms
• Hospital operating theaters
• Range 0-100pa
• Analogue Output 0-10V
• Plug top power supply included
• LoRa RF Tx included

3999-913-2232-B Wireless Pressure Differential Transmitter


• Cleaning rooms
• Hospital operating theaters
• Range 0-100pa
• c/w with RF Transmitter
Power Supply Unit required

3999-913-2108-A LoRa RF Status Transmitter


• Single Input c/w Magnetic Read Switch

34
Compliance
Healthcare
Healthcare facilities rely heavily on temperature of critical assets and
environments. Ensuring vaccines, medicines and bloods are stored
at correct temperatures, plus ensuring environmental temperature
conditions are optimised, are all therefore significant and can be
monitored by Invisible Systems.

Part No Description Image


LoRa RF Boxed Transmitter (room)
• Temperature
3999-913-2196-A Internal Antenna
3999-913-2205-A External Antenna
3999-913-2211-A *Alarmed – Internal Antenna
3999-913-2215-A *Alarmed – External Antenna

Compliance
LoRa RF Boxed Transmitter (room)
• Temperature
• Humidity
3999-913-2197-A Internal Antenna
3999-913-2206-A External Antenna
3999-913-2212-A *Alarmed – Internal Antenna
3999-913-2216-A *Alarmed – External Antenna
LoRa RF Boxed Transmitter (room)
• Temperature
• Humidity
• CO2 (0-5000ppm)
3999-913-2198-A Internal Antenna
3999-913-2207-A External Antenna
3999-913-2213-A *Alarmed – Internal Antenna
3999-913-2217-A *Alarmed – External Antenna

LoRa RF Boxed Transmitter (incubator)


• CO2 (0-20%)
• mains powered

3999-913-2201-A Internal Antenna


3999-913-2214-A External Antenna

Optional external Temperature & Humidity Probe on


flying lead.

*Temp Alarm configured at time of ordering

35
Compliance
Healthcare
Part No Description Image
LoRa RF Boxed Transmitter (room)
• CO2 (0-5000ppm)

3999-913-2203-A Internal Antenna


3999-913-2229-A External Antenna

LoRa RF Temperature transmitter


Shield Radiation Tube (-55°C/+85°C)

3999-913-2156-A • Standard Temperature


3999-913-2230-A • Alarmed Temperature
3999-913-2220-A • Memory Temperature
Compliance

3999-913-2128-A Outdoor Ambient Temp IP Case


(Memory and Alarmed Options)

LoRa RF Temperature transmitter


2m Flat PVC Cable (-55°C/+85°C)

3999-913-2103-A • Standard Temperature


3999-913-2200-A • Alarmed Temperature
3999-913-2219-A • Memory Temperature

3999-913-2269-B ISL Refrigeration Monitor


Laboratories & Life Science
• Temperature too High / Low
• Doors open too long
• Excessive vibration
• Power Loss
• One temperature probe included

36
Compliance
Healthcare
Part No Description Image
LoRa RF Temperature transmitter
2m PTFE Cable (-55°C/+85°C) 40x6mm

3999-913-2184-A • Standard Temperature


3999-913-2208-A • Alarmed Temperature
3999-913-2218-A • Memory Temperature

3999-913-2251-A LoRa RF Temperature transmitter


• PT100 Mk2 Temperature (-100°C/+230°C)
40x6mm
• 2M PTFE Cable

Compliance
3999-913-2254-A LoRa RF Temperature transmitter
• PT100 Mk2 (-196°C/+100°C)
• 2m PTFE Cryogenic Probe
• Mineral Insulated 500mm probe

LoRa RF Transmitter
Temperature (-55°C/+85°C)
c/w Magnetic Switch

3999-913-2186-A • 2M PVC Cable


3999-913-2209-A • 2M PVC cable Alarmed
3999-913-2187-A • 2M PTFE Cable
3999-913-2210-A • 2M PTFE cable Alarmed

3999-913-2253-A LoRa RF Transmitter


• PT100 Mk2 Temperature (-100°C/+230°C)
• 2M PVC Cable
• Magnetic switch

3999-913-2108-A LoRa RF Status Transmitter


• Single Input c/w Magnetic Read Switch

37
Compliance
Legionella
Improving water safety and ensuring legionella compliance is
significantly improved using the Invisible Systems Legionella Online
compliance system.
Temperature monitoring is an important legal requirement under
HSG274 Part 2, aimed to manage the risk and improve Legionella
control. The system is ideally suited for all hot and cold water systems,
calorifiers, cooling towers and water storage applications.

Part No Description Image


3999-913-2189-A LoRa RF Temperature transmitter
• Single Probe
• Temperature Min/Max (-55/+85°C)
• 2m PVC cable
Compliance

3999-913-2240-A LoRa RF Temperature transmitter


• Single Probe
• Temperature Min/Max (-55C/+85°C)
• 2m PTFE cable

3999-913-2194-A LoRa RF Dual Temperature transmitter


• Dual Probe
• Temperature Min/Max (-55C/+85°C)
• 2m PVC cable

3999-913-2221-A LoRa RF Dual Temperature transmitter


• Dual Probe
• Temperature Min/Max (-55C/+85°C)
• 2m PTFE cable

3999-913-2246-A LoRa RF Triple Temperature transmitter


• Triple Probe
• Temperature Min/Max (-55C/+85°C)
• 2m PVC cable

3999-913-2247-A LoRa RF Triple Temperature transmitter


• Triple Probe
• Temperature Min/Max (-55C/+85°C)
• 2m PTFE cable

38
Critical Asset Monitoring
& Industrial IoT

Gateways
Part No Description Image
3999-902-1443-A ISL 091 LoRa RF 2G Indoor Gateway DIN Rail Mounted
• LoRa RF Rx
• RS485 Comms
• 8 x Digital Input
• 4x Digital Output
• 4 x Digital Input
• 4 x 0-10V Input
• 4 x 20mA Input

3999-903-1444-A ISL 091 LoRa RF 2G Outdoor Gateway


• LoRa RF Rx
• RS485 Comms
• 8 x Digital Input
• 4x Digital Output
• 4 x Digital Input
• 4 x 0-10V Input
• 4 x 20mA Input
• Internal Power Supply
• IP65 Enclosure

Industrial IoT
Condition &
3999-902-1442-A Gen4 LoRa RF 2G Outdoor Gateway
• Legacy 868 RF Rx
• LoRa 868 RF Rx
• LoRa 868 RF Tx
• RS485 Comms
• 8 x Digital Input
• 4 x Digital Output
• 4 x 0-10V Input
• 4 x 4-20mA Input
• 2 x 24Vdc Aux Power Outputs
• GPS
• Internal Power Supply

3999-902-1451-A LoRa RF Ethernet Indoor Gateway


• LoRa RF Rx
• RS485 Comms
• SmartBUS

3999-902-1450-A LoRa RF Ethernet Outdoor Gateway


• LoRa RF Rx
• RS485 Comms
• SmartBUS
• Internal Power Supply
• IP65 Enclosure

39
Critical Asset Monitoring
& Industrial IoT

Gateways
Part No Description Image
3999-902-1429-B LoRa RF Central EIE Mk2 Network Server
• 1U Rack Mount
• Digital Processing
• PoE (Power over Ethernet)

3999-902-1440-B LoRa RF M2M Portable Rugged GPRS


Gateway
• LoRa RF Rx
• RS485 Comms
• 8 x Digital Input
• 4x Digital Output
• 4 x Digital Input
• 4 x 0-10V Input
• 4 x 20mA Input
• Internal Power Supply
• Optional Battery Backup
Industrial IoT
Condition &

LoRa RF Analogue Transmitter


3999-913-2095-A • 4-20mA Input
3999-913-2110-A • 0-1 volt
3999-913-2111-A • 0-5 volt
3999-913-2112-A • 0-10 volt

3999-913-2188-A LoRa RF Modbus Transmitter


• 2m PVC Cable
• Mains Powered

3999-913-2243-A LoRa RF Secondary Current Monitor


• Wireless 3 Phase
• IP65 PVC boxed
• Terminals
(CT’s not included)

40
Critical Asset Monitoring
& Industrial IoT

Sensors
Part No Description Image
LoRa RF Status Transmitter
3999-913-2130-A • Single Input
3999-913-2199-A • Dual Input

3999-913-2108-A LoRa RF Status Transmitter


• Single Input c/w Magnetic Read Switch

3999-913-2265-B Ultra RF Vibration Transmitter (0-2g)


Single Channel TX
Frequency Response: 10Hz (600cpm) to
5kHz (300kcpm) ± 5%
Current Output: 0-2g
Acceleration measured to give

Industrial IoT
Condition &
indication of bearing condition

3999-913-2266 Ultra RF Vibration Transmitter (0-2g)


Dual Channel TX
Frequency Response: 10Hz (600cpm) to
5kHz (300kcpm) ± 5%
Current Output: 4-20mA DC
Acceleration measured to give
indication of bearing condition

3999-913-2267 Ultra RF Pressure Transmitter Tx 4-20mA


• -1 to 0 bar
• Pressure overload: 150%FS
• Vacuum measurement

3999-913-2248-B LoRa RF Pressure Transmitter


• 0-150 bar
• Other pressures available

41
Environmental

Environmental Table of Content

Weather Station 43

Sensors 44 - 46
Environmental

Water 47

42
Environmental
Weather Station
The weather station is a permanently powered or solar powered, solid
state/LoRa sonic unit that communicates to Realtime Online web
based software.
Radio transmitters can be installed in the vicinity of the weather
station which communicate wirelessly over RF for additional
monitoring.

Part No Description Image


3999-913-2241-B Mains powered with RF Transmitter
LoRa RF Transmitter
• Temperature and Humidity
• Wind Direction and Speed
• Air Pressure
• Rain and Hail accumulation
3999-902-1437-B Mains powered with Gateway
GPRS Cellular Gateway
• Temperature and Humidity
• Wind Direction and Speed
• Air Pressure
• Rain and Hail accumulation
3999-913-2242-B Solar powered with RF Transmitter
LoRa RF Transmitter and solar panel
• Temperature and Humidity
• Wind Direction and Speed
• Air Pressure
• Rain and Hail accumulation

Environmental
3999-902-1439-B Solar powered with Gateway
GPRS Cellular Gateway and solar panel
• Temperature and Humidity
• Wind Direction and Speed
• Air Pressure
• Rain and Hail accumulation
3999-902-1438-B Solar powered portable version
Compact and housed in a robust peli case and solar
panel
• Temperature and Humidity
• Wind Direction and Speed
• Air Pressure
• Rain and Hail accumulation
3999-902-1453-B Weather station with GSM gateway
• Temperature and Humidity
• Wind Direction and Speed
• Air Pressure
• Rain and Hail accumulation
999-950-9551-B Optional Solar Radiation Sensor
c/w Bracket

43
Environmental
Sensors
Part No Description Image
3999-913-2188-A LoRa RF Modbus Transmitter
• 2m PVC Cable
• Mains Powered

LoRa RF Analogue Transmitter


3999-913-2095-A • 4-20mA Input
3999-913-2110-A • 0-1 volt
3999-913-2111-A • 0-5 volt
3999-913-2112-A • 0-10 volt

3999-913-2126-B LoRa RF Air Velocity Sensor


• Vanometer
• 0 - 30m/min
Environmental

3999-913-2258-A LoRa RF Transmitter


• Crack Monitor

3999-913-2255-A LoRa RF Temperature & Humidity


Transmitter
• Temperature
• Humidity

44
Environmental
Sensors
Part No Description Image
3999-916-1001-A Environmental Sensor (Data Centre)
Barometric Pressure, Temperature & Humidity
• The humidity sensor features a extremely fast response.
• High accuracy barometric pressure sensor
• High resolution temperature sensor.
• Status (e.g. door sensor)
3999-916-1002-A Environmental Sensor (Office)
Temperature, Humidity, CO2, Light & Pressure
• Monitoring room temperature
and air humidity and pressure
• Measure lighting conditions
• CO2 concentration (to 5000 ppm)
3999-916-1003-A PIR Transmitter
• PIR Human Detection Sensor, motion sensor.
• Configurable from PC application

3999-916-1006-A Leak Detection Transmitter


• Battery or Mains powered
• IP67 Enclosure
• LoRaWAN version available
• Configurable from PC App via USB
• For use with leak detection plate / cable
(sold seperately)

Environmental
3999-916-1018-A Analogue Input Transmitter
• Battery operated - battery life up to 5 years
• Range: 0 – 1V, 0 – 5V, 0 – 10V or 4 – 20mA
• Accuracy: ±0.1% FS

3999-916-1005-A Legionella Sensor


• Up to three external temperature probes
• LoRaWAN version available
• Configurable from PC application

3999-916-1004-A Wireless Meter


• Three inputs for splitcore current
transformers (CTs).
• Reports current and energy consumption in kWh
• LoRaWAN version available
• Configurable from PC application

45
Environmental
Sensors

Part No Description Image


3999-913-2259 LoRa PM2.5 - PM10 Transmitter
• Laser-based light scattering particle sensing
• Concentration range: 0 μg/m3 to 1,000 μg/m3
• Fully calibrated
• RoHS compliant
• REACH compliant
• Mains Powered!

3999-913-2260 LoRa VOC Transmitter


• MOX (Metal Oxide) Gas sensor to detect low levels of
VOC
• Fast cycle times
• Wireless range upto 15km line of sight
• Mains Powered!

3999-913-2298 LoRa RF Level Transmitter


• Calibration Units: Gauge, in mH2O
• Pressure Range: 0 - 6mH2O
• Accuracy: <±0.175% / FS BFSL
(Standard for Pn≥0.4 bar)
• Electrical Connection: PVC Cable
• Cable Length (enter in mtrs): 5 meter PVC
Environmental

• Wireless range upto 15km line of sight


• Approvals: ATEX (II 1 G Ex ia IIC T4)

T.B.C Oil condition monitoring sensor


• Highly accurate oil condition monitoring with certified
condition change detection sensitivity
• Status & health of your equiptment
• Reduced maintenance costs
• Increased efficiency & improved reliability

3999-913-2126 Air Velocity Transmitter


• User selectable output signal, 0-10Vdc or 4-20mA
• User selectable measurement ranges
• Durable and resistant to chemical reagents
• Adjustable probe depth using the opional DPA
• Built-in self-test feature

46
Environmental
Water
A wide range of wireless sensors are available for monitoring
water conditions such as flood and leak detection, ph and flow.

With an existing infrastructure and site installed Gateway, water


environmental monitoring becomes a simple and cost effective
solution.

Part No Description Image


3999-913-2109-A Leak Detection Transmitter
LoRa RF transmitter
• 5M PVC cw RJ12

300-087-0087-A Leak Detection Accessory - Conductivity Sensor


• Rigid sensor cw 2 x RJ12
• Rigid sensor (100x70)

220-210-2400-B RJ12 2m Cable


(to daisy chain conductivity Sensor)

Flood detection / Leak detection cable


120-340-3604-B • 5m Conductivity cable
120-340-3605-B • 10m Conductivity cable
120-340-3606-B • 15m Conductivity cable

Environmental
3999-916-1007-B • 450m Conductivity cable
(See Page 55 for more information.)

3999-913-2248-B LoRa RF Pressure Transmitter


• 0-150 bar
• Other pressures available

T.B.C Universal Water Analyser


• Multilingual
• High resolution grayscale display
• 9 buttons for easy navigation
• Graphing and datalogging
• IP65/Nema 4x
600-630-6323-B Flow meter - U1000 (clamp-on)
• Pipe diameter 25-115mm
• Min 20mm ID
• Flow range 0.1m/s-10m/s
• Output Pulse
See P/N 3999-913-2089 for tx (Page 17)

47
LoRaWAN

Part No Description Image


3999-916-1028-D MT LoRaWAN Outdoor Gateway
• ISM band scanning for optimum LoRa
performance
• Listen Before Talk operating
protocol NSS for location
coordinate information
• 27 dBm support for European region
• Certified for Europe 868 MHz,
North American 915 MHz ISM bands

3999-916-1029-D MultiTech POE Injector base station


3999-916-1030-D MultiTech Lightening Arrestors

3999-916-1032-D MT LoRaWAN Indoor Gateway


• 4G-LTE with 2x2 MiMo
• LoRa Omni-Directional internal
• antenna with +2 dBi gain for
868/915 MHz ISM band
• Ethernet RJ-45 10/100 BaseT for IP
backhaul

TBD LoRaWAN MT Indoor Gateway


• Certified for Europe 868 MHz, North
American and
Australian 915 MHz ISM bands
• 27 dBm support for European region
• ISM band scanning for optimum LoRa®
performance
• Listen Before Talk LoRa operating proto-
col
LoRaWAN

3999-916-1012-B LoRaWAN Industrial Tracker


• Supports GPS and GNSS
• Full LoRaWAN support
• Complete All in one solution
including Sensor, Software and
Network Management for fully
optimised asset tracking

48
LoRaWAN

Part No Description Image


3999-916-1001-A Environmental Sensor (Data Centre)
Barometric Pressure, Temperature & Humidity
• The humidity sensor features a extremely fast response.
• High accuracy barometric pressure sensor
• High resolution temperature sensor.
• Status (e.g. door sensor)

3999-916-1002-A Environmental Sensor (Office)


Temperature, Humidity, CO2, Light & Pressure
• Monitoring room temperature
and air humidity and pressure
• Measure lighting conditions
• CO2 concentration (to 5000 ppm)

3999-916-1003-A PIR Transmitter


• PIR Human Detection Sensor, motion sensor.
• Configurable from PC application

N/A Bin Sensor


• Helps planning and managing the capacity of the
containers
• Understand the waste you manage
• Cut costs on waste collection
N/A Smoke and Heat Detector
• Detects smoke
• Detects heat
LoRaWAN

N/A Soil Sensor


• Dust and waterproof
• Soil moisture monitoring
• Reduction in water usage

49
LoRaWAN

Part No Description Image


3999-916-1006-A Leak Detection Transmitter
• Battery or Mains powered
• IP67 Enclosure
• LoRaWAN version available
• Configurable from PC App via USB
• For use with leak detection plate / cable
(sold seperately)

3999-916-1018-A Analogue Input Transmitter


• Battery operated - battery life up to 5 years
• Range: 0 – 1V, 0 – 5V, 0 – 10V or 4 – 20mA
• Accuracy: ±0.1% FS

3999-916-1005-A Legionella Sensor


• Up to three external temperature probes
• LoRaWAN version available
• Configurable from PC application

3999-916-1004-A Wireless Meter


• Three inputs for splitcore current
LoRaWAN

transformers (CTs).
• Reports current and energy consumption in kWh
• LoRaWAN version available
• Configurable from PC application

50
LoRaWAN

Part No Description Image


3999-916-1034-D LoRaWAN MV2 Gateway
• Field proven with commercial deployments
• Modular architecture
• LoRaWAN™ 1.0.x and 1.1 compliant
• Integrated software module for an easy and scalable
integration

3999-916-1036-B LoRaWAN Tracking Device


• Supporting GPS/GNSS, Wi-Fi, BLE, LoRa™
• Multiple sensors are available like accelerometer and
pressure measurement
• Customisation of use cases could be acheived by a
JavaScript interface

3999-916-1037-B LoRaWAN Multi APP ATGHMP EndPoint


• Generic EndPoint platform for application development
• Accelerometer, temperature, gyroscope, humidity,
magnetometer, pressure sensors
• Button 3-colour LED interfaces
• JavaScript application support and JavaScript API to
sensor functions
• Debug with USB emulator version and flash code on
field device via NFC tool
• LoRaWAN™ compliant, with 'send' API

3999-916-1038-B LoRaWAN Motion Sensor


• Accelerometer w/ shock detection, Gyroscrope,
Temperature sensors
• Button and 3-colour LED interfaces
• LoRaWAN™ compliant
LoRaWAN
• Scenario customisation, programmable by JavaScript
API through NFC
• Compact EndPoint
• Optimized battery consumption

51
SmartBUS RF

Sensors
Part No Description Image
3999-902-1446-A ISL 091 LoRa RF Gateway
DIN Rail Mounted
• LoRa RF Rx
• RS485 Comms
• 8 x Digital Input
• 4x Digital Output
• 4 x Digital Input
• 4 x 0-10V Input
• 4 x 20mA Input

Options
3999-902-1447-A • GPS Module

3999-902-1448-A • 868 Legacy Receiver

2x Channel Input Variants of Transmitter


3999-914-1001-A • 2x Channel Status Input - SmartBus

3999-914-1005-B • 2x Channel Status Input - LoRa RF

3999-914-1003-A • 2x Channel Pulse Input - SmartBus

3999-914-1007-A • 2x Channel Pulse Input - LoRa RF

8x Channel Input Variants of Transmitter


3999-914-1002-A • 8x Channel Status Input - SmartBus

3999-914-1006-A • 8x Channel Status Input - LoRa RF

3999-914-1004-A • 8x Channel Pulse Input - SmartBus

3999-914-1008-A • 8x Channel Pulse Input - LoRa RF


SmartBUS RF

52
SmartBUS RF

Part No Description Image


Control Module Digital - DIN Rail c/w relays
3999-915-1003-A • 1 x Channel 8A SPDT - SmartBus

3999-915-1001-A • 1 x Channel 8A SPDT - LoRa RF

3999-915-1004-A • 4 x Channel 8A SPDT - SmartBus

3999-915-1002-A • 4 x Channel 8A SPDT - LoRa RF

Coming Soon Lighting Control


• Motion Sensor (PIR)

Coming Soon Manual RF Override Switch

SmartBUS RF

53
Tools &
Accessories

Part No Description Image


400-401-1439-A Steel Antenna Wall
mounting bracket -150mm

400-401-1439-A Steel Transmitter Wall


mounting bracket -150mm

400-402-2410-B Ceiling Fixing Assembly for transmitter &


40x6mm Stainless Steel Probe

400-402-2430-B Sleeve for ceiling probe fixing

(Extra Service) Conformal Coating


Price Per Transmitter

400-401-1464-B Wire mesh protection guard


All Transmitters

220-210-2394-B Digital Signage Controller


• HDMI Output 1080p
• Ethernet Input (LAN)
• Built in browser

3999-970-9704-C Optional 3G Router Port


Excluding sim card
Accessories

54
Tools &
Accessories

Part No Description Image


200-365-8046-B AC-DC Industrial DIN rail
power supply
Output 24Vdc at 1A

200-365-8056-A AC-DC Industrial Din rail Power Supply


Output 24W 12Vdc at 2A
• For use with Invisible Systems Gateway

200-365-8057-A AC-DC Industrial Din rail Power Supply


Output 12Vdc at 1.25A
• For use with Invisible Systems Gateway

200-365-8037-B AC-DC Power Supply 12V / 2.5A

200-365-8029-B 3.3V at 1.8A, 6W Interchangeable Power Supply


to power transmitters in place of battery.
Accessories

55
Tools &
Accessories

Part No Description Image


3999-913-2244-C LoRa RF Installers Kit c/w
• Diagnostics Software (058)
• Diagnostic Connection Cable
• GSM Signal Analyser
• Pulse counter

Installation Tools

220-210-2381-C • Diagnostic Connection Cable

Installation Tools

700-700-7004-C • GSM Signal Analyser

Installation Tools

700-700-7005-C • Pulse Counter

999-913-2235-C LoRa RF Range Test Kit


• LoRa RF Transmitter
• RF/Bluetooth Interface
• Android device
• Google Mobile App

700-700-7075-C USB Transmitter


Accessories

56
Tools &
Accessories

Part No Description Image


3999-913-2249-A Mobile Monitor
• RF/Bluetooth Interface
• Google Mobile App

3999-910-1212-A LoRa RF - Repeater (Transceiver)


c/w plug top power supply

3999-901-1219-A Legacy 868 MHz to LoRa RF


Frequency Convertor din rail and power supply
Coming Soon

3999-901-1220-A Legacy 433MHz to LoRa RF


Frequency Convertor din rail and power supply
Coming Soon

100-130-1155-C RF Alarm Indicator Lamp.


- for RF Alarm Display
(Part 3999-902-1427-A)

3999-916-1007-B Leak Detection Cable


• 450 meters
• Diameter: WDC2 3mm, WDC4 5mm, WDC6
8mm
• Annelid 0.4mm diameter Stainless Steel
• 7Ω per metre per sensor wire (14Ω per cable
metre)

TBC Waterproof Junction Box


Accessories

• Waterproof & dust-proof


• UV protection high quality material
• 2 Pin / 3 pin cables
• Wide usage

57
+44 (0) 1539 722 520 7 - 9 Beetham Road,

Email: info@invisible-systems.com Milnthorpe,


Cumbria,
Web: www.invisible-systems.com
LA7 7QL
United Kingdom

Helping You Exceed


Expectations

Invisible Systems design and


manufacture wireless energy monitoring
and control tools.
Realtime-Online™ provides access to your
valuable data, with a web
front-end for displaying information on
dashboards, a comprehensive reporting
suite and alarm notifications.

Designed, developed and manufactured


in-house, our system has been in
operation for over 10 years and has
been used in organisations throughout
the World for food compliance, to meet
requirements of BRC Global Standards
for Food Safety and HACCP.

Copyright © 2018 Invisible Systems Ltd.

You might also like