S36 -250mm S37 -250mm S38 -250mm S39 -250mm S40 -250mm

S1 -250mm S2 -250mm S3 -250mm S4 -250mm S5 -250mm S6 -250mm S7 -250mm S40 -250mm S39 -250mm S38 -250mm S37 -250mm S36 -250mm

S29 S30 S31 S32 S33 S34 S35 S35 S34 S33 S32 S31 S30 S29
Y Y Y Y Y S8 S9 S10 Y Y S11 S12 Y Y S13 S14 YY Y Y Y
1. READ THIS DRAWINGS IN
CONJUNCTION WITH ARCHITECTS' AND
A A A A OTHER ENGINEERS' DRAWINGS AND
SPECIFICATIONS, AND SUCH OTHER
Z Z Z Z Z Z Z Z WRITTEN
INSTRUCTIONS AS MAY BE ISSUED.
2. ALL DIMENSIONS ARE IN MILIMETRE
UNLESS STATED OTHERWISE.
S26 S27 S28 S15 S17 S28 S27 S26 3. DIMENSIONS SHALL NOT BE SCALED
S16
FROM THE DRAWINGS.
4. DESIGN CONFORMS TO:
- IS456:2000 CODE OF PRACTICE FOR
PLAIN AND REINFORCED CONCRETE
Z Z Z Z Z Z Z Z - IS1893: PART 1(2016) EARTHQUAKE
RESISTANT DESIGN AND CONSTRUCTION
OF BUILDINGS
- IS13920:1993 DUCTILE DETAILING OF
Y Y Y Y Y Y Y Y REINFORCED CONCRETE STRUCTURES
S19 S19 SUBJECTED TO SEISMIC FORCES
- IS 875 : 2015( Part 1 to 3) CODE OF
PRACTICE FOR DESIGN LOADS( OTHER
THAN EARTHQUAKE) FOR WIND LOAD ON
S20 S21 S22 S23 S24 S25 S25 S24 S23 S22 S21 S20 BUILDINGS AND STRUCTURES.
A A A A

A
5. VERIFY ALL SETTING OUT
DIMENSIONS WITH THE
ENGINEER/ARCHITECT. VERIFY LOCATION
AND DIMENSIONS OF CHASES, INSERTS,
OPENINGS, WASHES, DRIPS,
DEPRESSIONS, AND OTHER PROJECT
S16 S17 S17 S16 REQUIREMENTS NOT SHOWN ON THE
S18 S18
STRUCTURAL DRAWINGS.
6. IF IN DOUBT, ASK.
CONCRETE QUALITY SHALL COMPLY WITH
A

A
IS456:2000
7. PROJECT ASSESSMENT OF
S13 S14 S15 S15 S14 S13 CONCRETE STRENGTH IS REQUIRED.
-250mm
-250mm 8. GRADE OF CONCRETE IS M40 FOR
ALL RCC WORKS AND M30 FOR
FOUNDATION.
9. THE COVER TO THE
REINFORCEMENT NEAREST TO THE
CONCRETE SURFACE SHALL NOT BE LESS
S10 S11 S12 S12 S11 S10 THAN THE FOLLOWING EXCEPT
-250mm
WHERE SPECIFIED OTHERWISE:
X X X
-250mm
X - BEAMS 30 MM
- COLUMNS 40 MM
- FLOOR SLABS AND STAIRCASE 20
MM
S7 S8 S9 S9 S8 S-7
-250mm - FOUNDATION 50 MM
-250mm
10. THIS STRUCTURE HAS BEEN
DESIGNED FOR THE FOLLOWING NOMINAL
LOADS:
S5 -250mm S6 -250mm S6 -250mm S5 -250mm
- DEAD LOADS: UNIT WEIGHT OF
WALL 7 kN/m3
- UNIT WEIGHT OF RCC 25 KN/M3
- UNIT WEIGHT OF PCC 24 KN/M3
1.2 SUPERIMPOSED LOADS(LIVE LOADS):
- LIVE LOAD FOR FLOORS 4 N/MM2
(Load on commercial building)
- LIVE LOAD FOR STAIRCASE 4 N/MM2
- LIVE LOAD FOR ROOF 4 N/MM2
- FLOOR FINISH 1.5 N/MM2
11. FOOTINGS ARE DESIGNED FOR AN
S1 S2 S3 S4 S4 S3 S2 S1 ALLOWABLE BEARING CAPACITY OF
180KPA. VERIFY THE SOIL STRENGTH AND
OBTAIN APPROVAL
FROM THE ENGINEER BEFORE PLACING
CONCRETE.
12. COMPACTION OF FOUNDATION
SHALL BE APPROVED BY ENGINEER
PRIOR TO PLACEMENT OF CONCRETE.

X X X X

SLAB LAYOUT OF TYPICAL FLOOR


NIRMA UNIVERSITY

MINOR PROJECT ( GROUP 2)


PRITESH PARMAR (20MCLC06)
10 Φ-100C/C 10 Φ-180C/C 10 Φ-100C/C 10 Φ-700C/C 10 Φ-700C/C RAHUL PARMAR (20MCLC07)
Extra bar ABHISHEK PATEL (20MCLC08)
8Φ-300 C/C 8Φ-300 C/C
8Φ-900 c/c 10 Φ-100C/C BHAVYA PATEL (20MCLC09)

SLAB SCHEDULE

SECTION A-A CROSS MAIN DISTRIBUTION EXTRA TOP


THICKNESS REMARKS
SECTION REINFORCEMENT REINFORCEMENT BARS
SECTION X-X
X-X 150 MM 10 Φ-180C/C 8Φ-300 C/C 8Φ-900 C/C ONE WAY
10 Φ-200C/C 10 Φ-300C/C 10 Φ-100C/C SLAB
10 Φ-200C/C
8Φ-300 C/C 10 Φ-100C/C 8Φ-300 C/C
Y-Y 150 MM 10 Φ-200C/C 8Φ-300 C/C - ONE WAY
10 Φ-300C/C SLAB
Z-Z 150 MM 10 Φ-100C/C 8Φ-300 C/C - ONE WAY
SLAB
A-A 150 MM 10 Φ-100C/C 10 Φ-350C/C - TWO WAY
SECTION Z-Z SLAB
SECTION Y-Y