You are on page 1of 1

1.

READ THIS DRAWINGS IN


CONJUNCTION WITH ARCHITECTS' AND
OTHER ENGINEERS' DRAWINGS AND
SPECIFICATIONS, AND SUCH OTHER
WRITTEN
INSTRUCTIONS AS MAY BE ISSUED.
2. ALL DIMENSIONS ARE IN MILIMETRE
UNLESS STATED OTHERWISE.
3. DIMENSIONS SHALL NOT BE SCALED

4.9 m
3.6 m

3.6 m
1.4 m

FROM THE DRAWINGS.


C-1 4. DESIGN CONFORMS TO:
C-2 C-3 C-4 - IS456:2000 CODE OF PRACTICE FOR
PLAIN AND REINFORCED CONCRETE
- IS1893: PART 1(2016) EARTHQUAKE
1.4 m RESISTANT DESIGN AND CONSTRUCTION
OF BUILDINGS
- IS13920:1993 DUCTILE DETAILING OF
F1 REINFORCED CONCRETE STRUCTURES
SUBJECTED TO SEISMIC FORCES
- IS 875 : 2015( Part 1 to 3) CODE OF
3.85 m 3.85 m PRACTICE FOR DESIGN LOADS( OTHER
THAN EARTHQUAKE) FOR WIND LOAD ON
BUILDINGS AND STRUCTURES.
F2 4.9 m
F4 5. VERIFY ALL SETTING OUT
DIMENSIONS WITH THE
F3 ENGINEER/ARCHITECT. VERIFY LOCATION
6.1 m 9.04 m 9.04 m AND DIMENSIONS OF CHASES, INSERTS,
OPENINGS, WASHES, DRIPS,
DEPRESSIONS, AND OTHER PROJECT
REQUIREMENTS NOT SHOWN ON THE
STRUCTURAL DRAWINGS.
TOP VIEW OF FOOTING LAYOUT PLAN OF FRAME SECTION 6. IF IN DOUBT, ASK.
CONCRETE QUALITY SHALL COMPLY WITH
IS456:2000
7. PROJECT ASSESSMENT OF
CONCRETE STRENGTH IS REQUIRED.
8. GRADE OF CONCRETE IS M40 FOR
ALL RCC WORKS AND M30 FOR
FOUNDATION.
COLUMN BAR 9. THE COVER TO THE
REINFORCEMENT NEAREST TO THE
CONCRETE SURFACE SHALL NOT BE LESS
GROUND LEVEL THAN THE FOLLOWING EXCEPT
WHERE SPECIFIED OTHERWISE:
- BEAMS 30 MM
- COLUMNS 40 MM
- FLOOR SLABS AND STAIRCASE 20
MM
SPECIAL CONFINING REINFORCEMENT - FOUNDATION 50 MM
> 300 mm 10. THIS STRUCTURE HAS BEEN
DESIGNED FOR THE FOLLOWING NOMINAL
LOADS:
- DEAD LOADS: UNIT WEIGHT OF
COLUMN SCHEDULE WALL 7 kN/m3
.

- UNIT WEIGHT OF RCC 25 KN/M3


D

- UNIT WEIGHT OF PCC 24 KN/M3


1.2 SUPERIMPOSED LOADS(LIVE LOADS):
COLUMN SIZE
d
- LIVE LOAD FOR FLOORS 4 N/MM2
COLUMN (Load on commercial building)
- LIVE LOAD FOR STAIRCASE 4 N/MM2
MARK L(mm) B(mm) -
-
LIVE LOAD FOR ROOF 4 N/MM2
FLOOR FINISH 1.5 N/MM2
BOTTOM REBAR
CLEAR COVER 11. FOOTINGS ARE DESIGNED FOR AN
ALLOWABLE BEARING CAPACITY OF
SECTION A-A' C-1 300 300 180KPA. VERIFY THE SOIL STRENGTH AND
OBTAIN APPROVAL
FROM THE ENGINEER BEFORE PLACING
CONCRETE.
C-2 350 600 12. COMPACTION OF FOUNDATION
SHALL BE APPROVED BY ENGINEER
PRIOR TO PLACEMENT OF CONCRETE.

C-3 500 500

C-4 350 600

NIRMA UNIVERSITY

A A' FOOTING SCHEDULE MINOR PROJECT ( GROUP 2)


PRITESH PARMAR (20MCLC06)
RAHUL PARMAR (20MCLC07)
ABHISHEK PATEL (20MCLC08)
FOOTING SIZE BHAVYA PATEL (20MCLC09)
B

FOOTING BOTTOM REBAR IN BOTTOM REBAR


MARK L(mm) B(mm) D(mm) d(mm) L-DIRECTION IN B-DIRECTION

F1 1400 1400 450 230 10 mm @ 150 mm c/c 10 mm @ 150 mm c/c

F2 3850 3600 1000 600 16 mm @ 125 mm c/c 16 mm @ 125 mm c/c

F3 4900 4900 1200 600 20 mm @ 100 mm c/c 20 mm @ 100 mm c/c

F4 3850 3600 1000 500 16 mm @ 125 mm c/c 16 mm @ 125 mm c/c

L
TYPICAL FOOTING PLAN