GENERAL NOTES:

C6 C7

ALL DIMENSIONS ARE IN MM UNLESS MENTIONED AND


NEEDS TO BE CHECKED AS PER SITE CONDITIONS.

U DRAWINGS ARE TO BE READ AND NOT TO BE SCALED.


C1 C2 C3 C4 C5 C8 C9 C10
ANY DISCREPANCY IN THE DRAWING SHALL BE
NOTIFIED TO THE ARCHITECT BEFORE STARTING THE
150MM DRAIN 150MM DRAIN 150MM DRAIN
WORK.

1200 [3'-11"]
1350 [4'-5"]
900 [2'-11"]
700 [2'-4"] 950 [3'-1"]

150 [6"]
1125 [3'-8"]
5200 [17'-1"]

600 [2']

1300 [4'-3"]
U'
C' C 2475 [8'-1"] 2900 [9'-6"] 1025 [3'-4"] 1025 [3'-4"] 2975 [9'-9"] 1550 [5'-1"] 3925 [12'-11"] C' C LEGEND: MASONRY

3000 [9'-10"]
4"]
6197 [20'-

200MM THICK BRICK MASONRY


WALL TO BE STARTED WALL TO BE STARTED
FROM CENTER OF THE FROM CENTER OF THE
COLUMN COLUMN

C11 C12 C13 C14 C15 C16 C17 GOOD QUALITY HARD RED/BROWN
W BRICKS FOR EXPOSED WALL
V 650 [2'-2"]
2000 [6'-7"] 2000 [6'-7"] 2000 [6'-7"] 1950 [6'-5"] W
UP

1150 [3'-9"]
600 [2'] 2000 [6'-7"]
100MM REGULAR BRICKS/ FLY ASH

500 [1'-8"]
300 [1']
BRICKS FOR INTERNAL WALLS
C18 C19

2080 [6'-10"] 1225 [4'] 1225 [4'] 1225 [4'] 4350 [14'-3"]
W'
700 [2'-4"] 200 [8"]
V' W'

MASONRY LAYOUT GR FL 300 [1']

6600 [21'-8"] C6 C7
150 [6"] CLIENT SIGNATURE
150 [6"] A Z
4300 [14'-1"] 300 [1']
50 600 [2'] 300 [1'] 600 [2']

150 [6"]
400 150
600 [2']

600 [2']

600 [2']
B Y
C2 C3 C4 C5 C8 C9 C10

600 [2']

900 [2'-11"]
1290 [4'-3"] 890 [2'-11"] 900 [2'-11"] 2700 [8'-10"]

1500 [4'-11"]
B'
A'
DN ARCHITECT'S SIGNATURE
1400 [4'-7"]

2250 [7'-5"]
900 [2'-11"]

3550 [11'-8"]
3350 [11']

Y'

900 [2'-11"] 850 [2'-9"] 900 [2'-11"]


Z1'
Z1

This drawing is the property of ye and not be used or copied without their permission.

FOR CONSTRUCTION
50 50
1000 [3'-3"]

350
1200 [3'-11"] 1750 [5'-9"]
B B 700 [2'-4"] DRAWING TITLE:
C12 C13 C14 C15 C16 MASONRY LAYOUT GR FI FLOOR
50 MASTER BEDROOM
50 4.60X4.00
PROJECT:
B' B' 2175 [7'-2"] 1200 [3'-11"] CONSTRUCTION OF PROPOSED RESIDENCE FOR MR. D
X

460 [1'-6"]
1350 [4'-5"]

1350 [4'-5"]
N
HYNNIEWTA AT SITE BEARING SUR EY NO.
B TOWN COUNTRY PLANNING APPRO AL :

600 [2']
2725 [8'-11"] B' 1000 [3'-3"] hynniewta+machado
Z' 2200 [7'-3"] GOA . BANGALORE . MINNEAPOLIS
X' M -8007153148 /
E -ezekij@gmail.com

DESIGN TEAM KYR / EZE


SCALE 1 : 80 (OR AS SPECIFIED)

MASONRY LAYOUT FI FL DRAWING NO.


DATE
12
26102021
GENERAL NOTES:
C6 C7

ALL DIMENSIONS ARE IN MM UNLESS MENTIONED AND


NEEDS TO BE CHECKED AS PER SITE CONDITIONS.

U DRAWINGS ARE TO BE READ AND NOT TO BE SCALED.


C1 C2 C3 C4 C5 C8 C9 C10
ANY DISCREPANCY IN THE DRAWING SHALL BE
NOTIFIED TO THE ARCHITECT BEFORE STARTING THE
150MM DRAIN 150MM DRAIN 150MM DRAIN WORK.

1200 [3'-11"]
1350 [4'-5"]
900 [2'-11"]
700 [2'-4"] 950 [3'-1"]

150 [6"]
1125 [3'-8"]
5200 [17'-1"]

600 [2']

1300 [4'-3"]
U'
C' C 2475 [8'-1"] 2900 [9'-6"] 1025 [3'-4"] 1025 [3'-4"] 2975 [9'-9"] 1550 [5'-1"] 3925 [12'-11"] C' C LEGEND: MASONRY

3000 [9'-10"]
4"]
6197 [20'-

200MM THICK BRICK MASONRY


WALL TO BE STARTED WALL TO BE STARTED
FROM CENTER OF THE FROM CENTER OF THE
COLUMN COLUMN
GOOD QUALITY HARD RED/BROWN
C11 C12 C13 C14 C15 C16 C17
W BRICKS FOR EXPOSED WALL
V 650 [2'-2"]
1950 [6'-5"] W
UP

1150 [3'-9"]
600 [2'] 2000 [6'-7"] 100MM REGULAR BRICKS/ FLY ASH

500 [1'-8"]
300 [1']
BRICKS FOR INTERNAL WALLS
C18 C19

2080 [6'-10"] 9675 [31'-9"] 4350 [14'-3"]


W'
700 [2'-4"] 200 [8"]
V' W'

MASONRY LAYOUT GR FL @ BELOW WINDOW LE EL


CLIENT SIGNATURE

C6 C7
ARCHITECT'S SIGNATURE

300 [1'] CORE CUT IN WATER TANK

TYPICAL SECTION CC'


SLAB OF 300X150MM
150 [6"]

This drawing is the property of ye and not be used or copied without their permission.
600 [2']

FOR CONSTRUCTION
DRAWING TITLE:
MASONRY LAYOUT GR FI FLOOR
PROJECT:
C5 C8 CONSTRUCTION OF PROPOSED RESIDENCE FOR MR. D
HYNNIEWTA AT SITE BEARING SUR EY NO.
TOWN COUNTRY PLANNING APPRO AL :
N

hynniewta+machado
900 [2'-11"]

GOA . BANGALORE . MINNEAPOLIS

90 [4'-3"] 890 [2'-11"]


M -8007153148 /
E -ezekij@gmail.com

DESIGN TEAM KYR / EZE


SCALE 1 : 80 (OR AS SPECIFIED)

CORE CUT IN WATERTANK SLAB DRAWING NO.


DATE
12 A
26102021
GENERAL NOTES:

100
ALL DIMENSIONS ARE IN MM UNLESS MENTIONED AND
NEEDS TO BE CHECKED AS PER SITE CONDITIONS.

DRAWINGS ARE TO BE READ AND NOT TO BE SCALED.


500

ANY DISCREPANCY IN THE DRAWING SHALL BE


600 NOTIFIED TO THE ARCHITECT BEFORE STARTING THE
WORK.

LEGEND: MASONRY
200MM THICK BRICK MASONRY

MATCH BEAM TOP


UPTO SLAB BOTTOM
740

GOOD QUALITY HARD RED/BROWN


BRICKS FOR EXPOSED WALL
515

100MM REGULAR BRICKS/ FLY ASH


BRICKS FOR INTERNAL WALLS
75

100

DETAIL OF LINTEL
AS PER ENGINEER

600
50
650 150
1000

CLIENT SIGNATURE
1680

150
100
ARCHITECT'S SIGNATURE

1170
100

325

995 or as per site


200

This drawing is the property of ye and not be used or copied without their permission.
150

1000

FOR CONSTRUCTION
100

DRAWING TITLE:
DETAILS
100 MM THICK PCC PROJECT:
450

CONSTRUCTION OF PROPOSED RESIDENCE FOR MR. D


HYNNIEWTA AT SITE BEARING SUR EY NO.
200 MM THICK RUBBLE TOWN COUNTRY PLANNING APPRO AL :
SOILING
hynniewta+machado
GOA . BANGALORE . MINNEAPOLIS
M -8007153148 /
E -ezekij@gmail.com

DESIGN TEAM KYR / EZE


SCALE 1 : 100 (OR AS SPECIFIED)

SECTION WW SECTION UU SECTION UU SECTION Z1Z1 SECTION AA DRAWING NO.


DATE
13
19102021
GENERAL NOTES:

100
ALL DIMENSIONS ARE IN MM UNLESS MENTIONED AND
NEEDS TO BE CHECKED AS PER SITE CONDITIONS.

DRAWINGS ARE TO BE READ AND NOT TO BE SCALED.

ANY DISCREPANCY IN THE DRAWING SHALL BE

500
NOTIFIED TO THE ARCHITECT BEFORE STARTING THE
WORK.

MATCH BEAM TOP


LEGEND: MASONRY
200MM THICK BRICK MASONRY

100

740
GOOD QUALITY HARD RED/BROWN
BRICKS FOR EXPOSED WALL

515
100MM REGULAR BRICKS/ FLY ASH
100

BRICKS FOR INTERNAL WALLS

75

150MM THICK CONC. LINTEL


500
700

DETAIL OF LINTEL
200MM THICK LEDGE WALL AS PER ENGINEER
2300

2300
CLIENT SIGNATURE

2280
1200

1200

ARCHITECT'S SIGNATURE

This drawing is the property of ye and not be used or copied without their permission.

FOR CONSTRUCTION
DRAWING TITLE:
DETAILS
PROJECT:
CONSTRUCTION OF PROPOSED RESIDENCE FOR MR. D
HYNNIEWTA AT SITE BEARING SUR EY NO.
TOWN COUNTRY PLANNING APPRO AL :

hynniewta+machado
GOA . BANGALORE . MINNEAPOLIS
M -8007153148 /
E -ezekij@gmail.com

DESIGN TEAM KYR / EZE


SCALE 1 : 100 (OR AS SPECIFIED)

SECTION YY SECTION XX SECTION DRAWING NO.


DATE
14
19102021
GENERAL NOTES:

ALL DIMENSIONS ARE IN MM UNLESS MENTIONED AND


NEEDS TO BE CHECKED AS PER SITE CONDITIONS.

DRAWINGS ARE TO BE READ AND NOT TO BE SCALED.

ANY DISCREPANCY IN THE DRAWING SHALL BE


NOTIFIED TO THE ARCHITECT BEFORE STARTING THE
WORK.

UP TO
BEAM
LEGEND: MASONRY

TOP
200MM THICK BRICK MASONRY
BOTTOM

BOTTOM
100
UP TO

UP TO
BEAM

BEAM
GOOD QUALITY HARD RED/BROWN
BRICKS FOR EXPOSED WALL
100

100
100MM REGULAR BRICKS/ FLY ASH
BRICKS FOR INTERNAL WALLS

600
870

2100

1170
CLIENT SIGNATURE
100

900
500

ARCHITECT'S SIGNATURE

SECTION ZZ This drawing is the property of ye and not be used or copied without their permission.

FOR CONSTRUCTION
DRAWING TITLE:
DETAILS
300
PROJECT:
CONSTRUCTION OF PROPOSED RESIDENCE FOR MR. D
150

HYNNIEWTA AT SITE BEARING SUR EY NO.


TOWN COUNTRY PLANNING APPRO AL :

hynniewta+machado
GOA . BANGALORE . MINNEAPOLIS
M -8007153148 /
E -ezekij@gmail.com

DESIGN TEAM KYR / EZE


SCALE 1 : 100 (OR AS SPECIFIED)

SECTION BB DRAWING NO.


DATE
13