You are on page 1of 1

NOTES

1 All dimentions shown in mm. Drawing not to be scaled. Only figured


dimensions to be used.

A B C D A B C D 2 The Contractor must check and verify all dimentions on site before

S-01
S-01
LR NO: commencement of work. Any discrepancies must be reported to the
LR NO:
LR NO: Architect immediately.
LR NO: 200 9,200 200 3,300 1,400 4,700 3 All RC work to be to structural Engineer's details
3,300 1,400 4,700
200 4,500 200 4,500 200 4 All walls to be reinforced with hoop iron at every alternate course

9 9 9 9 5 3 ply bituminous felt slip joint to be provided between masonry and rc work
North Elevation

200

200
North Elevation
6 PV denotes parmanent vent

2,700
2,700

2,500

2,500
2,700
7 RWDP denotes rain water down pipe

LR NO: 8 IC denotes inspection chamber


SITE
LR NO: Terrazzo ff 9 SVP denotes soil vent pipe

LR NO: 8 8 8 8

200

200
10 All drain pipes passing under slabs to be encased in 150mm thick conc.
surround

master master
bedroom bedroom

3,200
2
14,400,000 mm 15,382,256
ceramic tiles ff mm
2
lounge

3,900
lounge

4,500
ceramic tiles ff

4,500

4,500
ceramic tiles ff
ceramic tiles ff
pv
Site Plan pv

200
200
pv pv pv
wc pv
7 7 7 wc pv kitchen 7
kitchen pvc tile floor

1,600
pvc tile floor
bedroom 2

3,500
A B C D bedroom 2
10,467,744 mm 2 finish 10,467,744 mm 2 finish

2,600
2,600

2,600
ceramic tiles ff
ceramic tiles ff
pv pv

200
non slip
non slip
ceramic
tiles ff yard
ceramic
tiles ff yard
900mm high balcony painted to 6 pv 6 6 6

20,800
9

20,700
1,200

200
21,000

1
architects approval pv 19 x 150 = 2,850

3,600
19 x 150 = 2,850

entry

2,600
2,600

2,400

2,600
10
10
Terrazzo ff
S-02 S-02 S-02 S-02
1,500

Terrazzo ff

200

12

13

14

15

16

17

18

19
11
5 5

12

13

14

15

16

17

18

19
11
5 5
150

pv
900mm high balcony painted to

1,100
wc

200

600
1,100

1,100
1,200

pv pv pv
architects approval bath
4 non slip
4 4 pv pv 4

200
pv pv
bedroom 2

2,800
ceramic non slip
steel casement window tiles ff
bedroom 9,797,744 mm2 ceramic
kitchen

1,800
1,800

1,800
1,500

to schedule
tiles ff
ceramic tiles ff pv pvc tile floor
ceramic tiles ff pv
kitchen

3,200
pv finish

3
pvc tile floor
finish 3 3 pv
pv 3

200
1,350

pv pv
pv pv pv

3,100
steel casement window pv

3,100

3,100
2,800
lounge entry

200
ceramic tiles ff
to schedule
1,500

ceramic tiles ff master


14,182,256 mm 2
lounge
200mm thick masonry machine Terrazzo ff bedroom
dressed stone wall to Arch. 2 2
2 2 ceramic tiles ff

4,000
1,350

approval pv

2,200 200
pv pv pv pv

2,400
SEPTIC

2,400

2,400
steel casement windows
1,500

to schedule pv

1 1 1 1

200

200
9,600 200 200
1,350

160 40 4,500 200 1,000 1,600 1,500 200

pv South Elevation South Elevation

S-01
pv
steel casement windows

S-01
to schedule A B C D A B C D
1,500

200mm thick masonry machine


1,050

dressed stone wall to Arch.


approval
REVISIONS
NO DATE DETAILS

Ground Floor Layout Typical Floor Layout


pv
2,850

200mm thick masonry machine


dressed stone wall to Arch.
approval

South Elevation 1 2 3 4 5 6 7 8 9
A B C D
3,300 1,400 4,700
2,400 3,100 1,800 1,100 2,600 2,600 4,500 2,700
900mm high parapet wall

900
900
D C B A finished to architect's approval

600
2000ltr capacity water tanks to
M.E specification

1,350
900mm high parapet wall

2,850
finished in plaster and paint to 2000ltr capacity water tanks to
900

1,200

architect's approval M.E specification 900mm high parapet wall


finished to architect's approval

900
900mm high parapet wall
450 mm thick RC beam to S.E
1,950

finished to architect's approval pv pv


1,650

details

450
pv
900mm high parapet wall pv 450 mm thick RC beam to S.E
pv pv 200mm thick masonry machine

2,850
pv details
finished in plaster and paint to

2,400
450

dressed stone wall to Arch.


900

1,200

pv pv
architect's approval LOUNGE
steel casement windows approval
2,850
2,400

LOUNGE KITCHEN STAIRWELL KITCHEN LOUNGE to schedule


steel casement windows pv
1,500

pv
to schedule pv steel casement windows
2,850

450
pv pv pv pv to schedule

2,850
pv steel casement windows
200mm thick masonry machine

2,400
1,350

dressed stone wall to Arch. to schedule 900mm high balcony painted to


2,850
2,850

pv pv
approval architects approval
LOUNGE KITCHEN STAIRWELL KITCHEN LOUNGE
450 mm thick RC beam to S.E
pv
1,500

pv
steel casement windows details
2,850

450
to schedule 450 mm thick RC beam to S.E
pv pv pv pv pv pv steel casement windows
details

2,850
pv

2,400
to schedule PROJECT ARCHITECT: NORBERT MUSYOKI
1,350

steel casement windows B. Arch, M. Arch, FAAK NO. 931 REG. NO. 591
2,850
2,850

pv pv SIGNATURE:

LOUNGE
to schedule
steel casement windows KITCHEN STAIRWELL KITCHEN LOUNGE
CLIENT'S SIGNATURE:
to schedule pv
1,500

pv
steel casement windows
2,850

450
pv pv pv pv pv pv to schedule

2,850
pv steel casement windows

2,400
BO MA CO NSULTANTS
1,350

to schedule
RC staircaseto SE details Architects and Urban Designers
2,850
2,850

pv pv
LOUNGE KITCHEN STAIRWELL KITCHEN LOUNGE Risers= 150
steel casement windows P. O. Box 72635-00200, NAIROBI, TEL. 559653

to schedule pv Treads = 300 MOBILE: 0722-398205, 0722735370


1,500

RC staircaseto SE details pv
finished in terrazzo with non slip grooves. MS
JOB:
2,850

450
Risers= 150
pv pv pv pv pv handd rail and balusters painted to Arch. PROPOSED RESIDENTIAL DEVELOPMENT,
Treads = 300
2,850
200mm thick masonry machine approval CHOKAA, NJIRU, NAIROBI
450
1,050

2,550
finished in terrazzo with non slip grooves. MS
dressed stone wall to Arch.
hand rail and balusters painted to Arch.
2,850

pv pv
approval LOUNGE 500g polythene sheet dpm on
300

2,400

STAIRWELL KITCHEN
KITCHEN approval 50mm sand blinding layer CLIENT:
steel casement windows 500g polythene sheet dpm on MR NDWIGA
1,500
2,850

to schedule 50mm sand blinding layer


SCALE: DATE: DRAWING NO:
Strip foundation to S.E details Nov 2018
1,050

Strip foundation to S.E details


JOB NO: DRAWN BY:
A-01
Jonathan

North Elevation Section 01 Section 02 TITLE: FLOOR PLANS, SECTIONS, AND ELEVATIONS