You are on page 1of 7

10. SERVICE MODE Field Service Ver.1.0 May.

2008

10.7.2 Load Check


This machine is provided with an input/output check function as a self-diagnostic function. For the load check,
the check and adjustment (output check) of the load operation can be made.

A. Procedure

"Service Mode screen"


Press [State Confirmation].
"State Confirmation screen"
Press [Load check].
"Load Check screen"
Press [Check Code] and enter a load check code in 3 digits through the copy count setting key.
For the multi mode, press [Multi Code] and enter a multi code in 3 digits through the copy count setting
key.
Press the Start key.
The load check operation starts with a message "Operating" displayed.
Press the Stop key.
The load check is completed with a message "Fin" displayed.
When conducting other load operations or the output check of signals, repeat steps 3 to 6.

B. List of loads

Name Restrictive conditions

0 0 L1 Exposure lamp
1 0 M4, Toner supply motor, toner solenoid Same as 55-003
SD5 turn ON at the same time

20 1 CL4 Feed clutch /1


2 CL5 Feed clutch /2
3 CL6 Feed clutch /BP
4 SD1 Pick-up solenoid /BP
5 SD151 Pick-up solenoid (LU)
21 1 M9 Feed motor (LS250)
2 Feed motor (LS210)
3 Feed motor (LS125)
4 M122 Paper feed motor /3 (LS250) (PC-206) Valid only when the paper empty sen-
5 Paper feed motor /3 (LS210) (PC-206) sor /3 (PS115) detects a no paper
condition.
6 M123 Paper feed motor /4 (LS250) (PC-206) Valid only when the paper empty sen-
7 Paper feed motor /4 (LS210) (PC-206) sor /4 (PS124) detects a no paper
condition.
Field Service Ver.1.0 May. 2008 10. SERVICE MODE

Name Restrictive conditions

21 8 M150 Feed motor (LS250) (LU)


9 Feed motor (LS210) (LU)
11 M9, Feed motor (LS250), registration
CL1, clutch, loop clutch turn ON at the
CL2 same time
12 M122 Paper feed motor /3 (LS125) (PC-206) Valid only when the paper empty sen-
sor /3 (PS115) detects a no paper
condition.
13 M123 Paper feed motor /4 (LS125) (PC-206) Valid only when the paper empty sen-
sor /4 (PS124) detects a no paper
condition.
14 M150 Feed motor (LS125) (LU)
22 1 M120 Vertical conveyance motor /3 (LS250)
(PC-206)
2 Vertical conveyance motor /3 (LS210)
(PC-206)
3 Vertical conveyance motor /3 (LS125)
(PC-206)
4 M121 Vertical conveyance motor /4 (LS250)
(PC-206)
5 Vertical conveyance motor /4 (LS210)
(PC-206)
6 Vertical conveyance motor /4 (LS125)
(PC-206)
7 M120, Vertical conveyance motor /3, /4
M121 (LS250) (PC-206)
8 Vertical conveyance motor /3, /4
(LS210) (PC-206)
9 Vertical conveyance motor /3, /4
(LS125) (PC-206)
10 M2 Vertical conveyance motor (LS250)
(PC-407)
11 Vertical conveyance motor (LS210)
(PC-407)
12 Vertical conveyance motor (LS125)
(PC-407)
23 1 M7 Paper lift motor /1 The upper limit sensor /1 (PS6) turns
ON, or it is stopped by the stop but-
ton.
2 M8 Paper lift motor /2 The upper limit sensor /2 (PS13) turns
ON, or it is stopped by the stop but-
ton.
10. SERVICE MODE Field Service Ver.1.0 May. 2008

Name Restrictive conditions

23 3 M124 Paper lift motor /3 (PC-206) The upper limit sensor /3 (PS114)
turns ON, or it is stopped by the stop
button.
4 M125 Paper lift motor /4 (PC-206) The upper limit sensor /4 (PS123)
turns ON, or it is stopped by the stop
button.
5 M151 Paper lift motor (LU) The upper limit sensor (PS152) turns
ON, or it is stopped by the stop but-
ton.
6 M9, Feed motor, pick-up solenoid /BP turn Valid only when the paper empty sen-
SD1 ON at the same time sor/BP (PS18) detects a no paper
condition.
25 1 CL1 Registration clutch
2 CL2 Loop clutch
3 CL3 Vertical conveyance clutch
4 CL151 Feed clutch (LU)
29 0 SD2 Drum claw solenoid ON
31 1 M2, L1 Scanner motor, exposure lamp After home position search, A3
makes a single scan operation.
2 Scanner motor, exposure lamp After home position search, A3
makes a continuous scan operation.
8 M2 Scanner motor The exposure unit is moved to DF
read position.
9 Scanner motor The exposure unit is moved to stand-
by position.
32 1 M5 Polygon motor (LS250)
2 Polygon motor (LS210)
34 0 M2, L1 Shading correction operation
36 0 LDB Laser PWM (0 to 255)
37 0 LDB, Laser turns ON forcibly The polygon motor (M5) turns ON
M5 and OFF at the same time.
38 0 LDB, LD alarm check The polygon motor (M5) turns ON at
M5 the same time and the results are dis-
played when it turns OFF.
999 LD alarm, data clear
39 0 L1 Platen stop APS The exposure lamp turns ON with
APS processed forcibly.
40 1 M11 Fusing motor (LS250)
2 Fusing motor (LS210)
3 Fusing motor (LS125)
41 1 M1 Drum motor (LS250) The charging corona turns ON at the
same time.
Field Service Ver.1.0 May. 2008 10. SERVICE MODE

Name Restrictive conditions

41 2 M1 Drum motor (LS210) The charging corona turns ON at the


same time.
3 Drum motor (LS125) The charging corona turns ON at the
same time.
4 Drum motor (LS250)
5 Drum motor (LS210)
6 Drum motor (LS125)
42 1 FM3, Exhaust fan /Fr, /Rr turn ON at the
FM9 same time
2 FM4 Drum cooling fan
3 FM2, Fusing cooling fan /Fr, /Rr turns ON at
FM8 the same time
4 FM1 Power supply cooling fan
5 FM6 Developing suction fan
6 FM5 Coveyance suction fan
7 FM7 Developing cooling fan
43 1 TCT Total counter 1 count up
2 KCT Key counter 1 count up
44 1 — — —
2 M3 Developing motor (LS210)
3 Developing motor (LS125)
45 1 L2 Fusing heater lamp /1 Caution
2 L3 Fusing heater lamp /2 • Since no high temperature
3 L2, L3 Fusing heater lamp /1, /2 turn ON at detection is made, be careful
the same time not to turn on for more than 10
seconds. Otherwise, the fusing
4 L2, Fusing heater lamp /1, fusing motor
roller may deform, thus caus-
M11 turn ON at the same time
ing a fire.
5 L3, Fusing heater lamp /2, fusing motor
M11 turn ON at the same time
6 L2, L3, Fusing heater lamp /1, /2, fusing
M11 motor turn ON at the same time
46 0 — Dehumidifier Heater 1C
48 0 PKB Operation panel check (panel key-
board LEDs all turm ON)
49 0 LCD Operation panel check
1 — — —
10. SERVICE MODE Field Service Ver.1.0 May. 2008

Name Restrictive conditions

51 1 EL Only erase lamp 24V ON


2 EL Erase lamp
52 0 TSL Transfer exposure lamp
53 0 SD4 Web solenoid
55 1 M4 Toner supply motor
2 SD5 Toner solenoid
3 M4, Toner supply motor, toner solenoid
SD5 turn ON at the same time
56 1 M10 Toner bottle motor (CW)
2 Toner bottle motor (CCW)
57 0 PZS Toner remaining sensor ON/OFF
1 Toner remaining sensor ON
59 0 RL1 Main relay
60 1 M1 Original feed motor
2 M2 Original conveyance motor
3 FM3 Cooling fan
4 SD1 Pressure roller release solenoid
5 SD2 Stamp solenoid
6 LB Print lamp (LED board) green ON
7 LB Print lamp (LED board) red ON
8 M1, 1 side original scan continuous opera-
M2, tion (no original)
9 SD1 2 sides original scan continuous oper-
ation (no original)
10 1 side original scan continuous opera- Operates according to the original
tion (original) size set.
11 1 side mixed original scan continuous
operation (original)
12 2 sides original scan continuous oper-
ation (original)
70 1 M2 Conveyance motor (10 seconds ON)
2 — — —
3 M4, After alignment motor /Rr, /Fr opera-
M5 tion, home position search
4 — — —
5 M11 Tray lift motor up Stops when the upper limit sensor
(PS15) turns ON after the tray posi-
tion sensor (PS3) detects the tray 2.
Field Service Ver.1.0 May. 2008 10. SERVICE MODE

Name Restrictive conditions

70 6 M11 Tray lift motor initial operation After the tray goes down, it goes up
when the lower limit sensor (PS14)
turns ON and it stops when PS15
turns ON. It becomes valid after exe-
cuting the load check 70-5.
7 M12 Shutter close/open operation once At the same time, the paper exit roller
release/pressure operation is made
by the paper exit roller release motor
(M6).
8 — — —
9 — — —
10 — — —
11 M6 Release/press operation of exit roller
once
12 M9 Open/close operation once of paper
exit opening (SD)
13 — — —
14 — — —
15 — — —
16 — — —
17 M7 After 2-staple positioning, home posi-
tion search
18 — — —
19 — — —
20 — — —
21 — — —
22 — — —
23 M10, Folding once (SD)
M14
24 to 52 — — —
53 M1, Exit motor (1 second ON), stacker
SD1 paddle solenoid ON/OFF
54 M1, Exit motor (1 second ON), exit paddle
SD2 solenoid ON/OFF
55 to 77 — — —
78 M1 Punching once (PU)
79 M2 Switching the number of punches Inch only
10. SERVICE MODE Field Service Ver.1.0 May. 2008

Name Restrictive conditions

80 1 M6 Reverse motor (LS250) rotating for-


ward
2 Reverse motor (LS210) rotating for-
ward
3 Reverse motor (LS125) rotating for-
ward
4 Reverse motor (LS250) rotating back-
ward
5 Reverse motor (LS210) rotating back-
ward
6 Reverse motor (LS125) rotating back-
ward
81 1 CL7 ADU conveyance clutch /Up
2 CL8 ADU conveyance clutch /Lw
3 M9, Feed motor, ADU conveyance clutch
CL7 /Up turn ON at the same time
81 4 M9, Feed motor, ADU conveyance clutch
CL8 /Lw turn ON at the same time
5 M9, Feed motor, ADU conveyance clutch
CL7, /Up, /Lw turn ON at the same time
CL8
83 0 SD3 Reverse solenoid
89 0 — KM brand setting
1 — OEM setting (A-Type)
2 — OEM setting (B-Type)
3 — OEM setting (C-Type)
90 0 — PM counter clear
91 0 — Process counter clear No use allowed in the field.
1 — Drum counter clear No use allowed in the field.
92 — — NVRAM board data reset No operation available in the field.
93 0 — Field initial set