List of Contents 80009161 Ver.: 1.0
List of contents
1. Contents
.01 Lists of contents
.10 Lists of references
2.
4. Layout
.10 Flow diagram
5. Interconnection Diagrams
.05 Power (incl. ventilator, fuses, light, air-con etc.)
.06 Power (incl. Control Display, power supply, PLC etc.)
.08 Power (48VDC)
.10 Emergency stop circuits
.11 Emergency stop circuits, Expansion
.30 Interlocks from/to gear lubrication unit
.40 Oil tank temperature, grinding pressure & grinding layer thickness
.41 Main valve supervision and roller position
.42 Pressure Transmitters for accumulators
.43 Diff. pressure for oil filter, oil tank levels
.44 Solenoid valve -Y01, -Y02, -Y03 and -Y04
.60 Circulation pump -M01
.61 Hydraulic pump -M02
.62 Heating element -E01
6. Parts Lists
.01 Parts list
7.
12/03/2008 KHP/SVo/FleJ
08:53:0025
Local control panel 1.10
List of references 80009161 Ver.: 1.0
List of references
20-Aug-08 KHP/KHP/MRSc
Local control panel HY-AM-1011 3.01
System structure and operation procedure 80009161 Ver.: 1.0
LIST OF CONTENTS
GENERAL DESCRIPTION..................................................................................................... 10
OPERATION............................................................................................................................ 11
Operation of the heating system .......................................................................................... 11
Hydraulic system ................................................................................................................. 11
Lifting the rollers ................................................................................................................. 11
Grinding control................................................................................................................... 12
OPERATING PROCEDURE, CONTROL DISPLAY ............................................................ 13
Main menu picture ............................................................................................................... 14
Mode of operation................................................................................................................ 15
Central Control Mode ..................................................................................................... 15
Local Control Mode ........................................................................................................ 15
Local Test Mode ............................................................................................................. 15
Mimic diagram..................................................................................................................... 16
Control menu ....................................................................................................................... 17
Control picture No. 1 - Local control, Hydraulic unit..................................................... 17
Control picture No. 2 - Local control, Heating ............................................................... 19
Control picture No. 3 - Central control, Change filter .................................................... 20
Control picture No. 4 - Local test, Pumps....................................................................... 21
Control picture No. 5 - Local test, Heating element ....................................................... 22
Alarm list ............................................................................................................................. 23
CCS signals status, digital ................................................................................................... 27
CCS signals status, analogue ............................................................................................... 28
Parameter menu ................................................................................................................... 29
Parameter picture No. 1 - Alarm limits........................................................................... 30
Parameter picture No. 2 - Override CCS signal.............................................................. 31
Parameter picture No. 3 - Setpoint and Delaytime ......................................................... 32
Parameter picture No. 4 - Control limits......................................................................... 33
Parameter picture No. 5 - Water cooling system ............................................................ 34
Parameter picture No. 6 - Empty/filling oil tank............................................................. 35
Parameter picture No. 7 - Local test valves .................................................................... 36
Parameter picture No. 8 - Local test pressure systems.................................................... 37
GENERAL SPECIFICATION ................................................................................................. 40
GENERAL DESCRIPTION
The hydraulic systems main function is to maintain the grinding pressure within a set range, and to
control the position (up/down) of the grinding rollers.
The hydraulic system consists of a hydraulic pump unit (oil tank, valves and a hydraulic pump), 3
hydraulic controlled cylinders and one set of connections between the pump unit and the
cylinders.
The oil tank is equipped with a heating element(s) and a circulation pump to heat the oil to a
proper operation temperature.
In the circulation string is build in a filter to clean the oil, and a water-cooled heat exchanger to
cool the oil if necessary.
The heating and circulation are, based on a temperature measurement in the oil tank, controlled
from the local control panel; the water-cooled heat exchanger is likewise controlled by the
temperature sensor in the oil tank.
The hydraulic pump supplies through the valve block oil to the cylinders. The grinding pressure
and the position of the grinding rollers are controlled by starting and stopping the hydraulic pump
and by opening and closing the valves.
A full description of the functions and maintenance of the hydraulic system can be obtained in
FLS instruction manual.
OPERATION
Before start, the heating system must be ready i.e. no alarms must be present in the system.
When a start command to the heating system is given, the heating element will be energized and
the temperature in the oil tank will rise.
When the tank oil temperature > 1°C, the circulation pump will start and oil circulation will take
place.
When the tank oil temperature > 40°C , the heating element will be de-energized, and when the
temperature has dropped below 35°C , the heating element will again be energized.
When the tank temperature exceeds the temperature t-max (see parameter picture) for water
cooling ON, the valve Y04 will be energized. When the temperature has dropped below t-min, the
temperature for water cooling OFF, Y04 will be de-energized.
If the tank temperature drops below 1°C, the circulation pump will stop.
Hydraulic system
Before start, the hydraulic system must be ready i.e. no alarms must be present in the system, and
the tank oil temperature > 17°C.
The main relief valve Y03 is energized as soon as the system is powered up, and will relieve the
system in case of power failure.
The mill has always to be started with the rollers in lifted position to minimize the breakaway
torque of the mill motor.
When the command to lift the rollers "Rollers up" is given the hydraulic pump will be started and
the hydraulic pressure will rise.
When the pressure exceeds min.1, the solenoid valves Y01 and Y02 will be energized and the
rollers will be lifted.
When the rollers reach their top position the mill motor can be started.
Grinding control
When the mill motor and the mill feed system is in operation and the command "Start grinding
control" is given (and the signal "rollers up" removed), the hydraulic pump will start if not already
started and the solenoid valves Y01 and Y02 will be de-energized.
The rollers will now be lowered onto the grinding table, and the grinding pressure will start to rise.
When the grinding pressure has reached the setpoint value and a delaytime is expired, the signal
"grinding in operation" is send to CCS.
The grinding pressure will be kept on the setpoint value in the following way.
Around the setpoint is programmed 4 limits P1, P2, P3 and P4.
When the grinding pressure reaches the value Setpoint + P1, the hydraulic pump will be stopped,
if the pressure continues to raise the solenoid valve Y2 will be energized and the pressure starts to
be relieved, when the pressure exceeds setpoint + P3.
If the grinding pressure drops below setpoint - P2, the solenoid valve Y02 will be de-energized
and relieve of the pressure will stop. If the pressure drops below setpoint - P4, the hydraulic
pump will start again.
The setpoint can be set from the Central Control system, or when in Local Control mode from the
local control panel.
The 4 limits P1, P2, P3 and P4 can be adjusted as parameters in the local control panel.
General
The local control panel is equipped with a control display (CD), which acts as a communication
interface between the PLC and the operator. The CD's touch screen functions make it possible for
the operator to operate the system, monitor various functions, change parameters and display
actual values. The various pages and functions on the display have been designed and
programmed to suite the operational needs of this unit.
Operating functions and changing of parameters, which should be protected against intervention
by unauthorised personnel, are protected by a password.
Display design
Information and functions are to be looked for in screen pictures with the following headlines:
-Main menu
-Mode selection
-Mimics
-Control
-Local test
-Alarms
-Alarm history
-Parameters
-CCS signal status
Touch function
Touch sensitive key areas are shown as push buttons. Use a light pressure with a finger to activate.
Detailed description
On the following pages a description of each screen picture and explanations of the various
functions etc. that appears on the screen will follow.
Main menu picture shows the different pictures that can be selected by activating the appropriate
touch key. The pictures are placed in groups by type as listed below:
PARAMETER When the touch key SET VALUE is pressed a numeric keyboard will
appear. When the correct password (=number) is entered in the numeric
keyboard a menu of the parameter pictures will appear.
(PASSWORD = 3618)
STATUS When the touch key CCS SIGNAL is pressed a status of signals between
CCS and local control panel (LCP) will appear.
On the top of all pictures, a ”Top menu bar", is shown. From the ”Top menu bar" other pictures
can be selected, further the actual control mode and alarm status are shown.
.
Mode of operation
Three different modes of operation for the machine can be selected. The actual selected mode will
be indicated with light in the appertaining touch key.
Mimic diagram
A motor (M01) is shown as an icon with the letter “M” inside and a heating element (E01) is
shown as a rectangular symbol showing the following status:
White (Stopped), green (Running/Activated), red (Alarm).
Digital alarms are shown as a red circle with a letter within when in alarm state with the following
letters applied otherwise invisible:
"L" (Level), "P" (Pressure)
A flashing "T" next to a heating element indicates that a preset temperature (thermostat inside
heating element) is reached and de-energize the heating element. The flashing “T” disappears
when the temperature has dropped below hysteresis of the thermostat and the heating element is
re-energized.
A filer is indicated as a squared box with a dotted horizontal line inside showing the following
status: White (OK), red (blocked) alarm.
Control menu
From Control Menu tree test modes can be chosen:
Local Control Mode - Hydraulic unit
Local Control Mode - Heating system
Central Control Mode - Changing oil filter
From control picture Local Control Hydraulic unit, it is possible in Local Control mode
“LC MODE” to select two modes:
ROLLERS UP
GRINDING CONTROL
Rollers up:
When the system is ready to start, a green dot will appear in the “START” push button. When the
start button is activated, the hydraulic pump will start.
The hydraulic pressure will raise and when it reaches MIN.1, the solenoid valves Y01 and Y02
will be energized, and the rollers will start to lift. The rollers will remain in top position as long as
the button is indicating green
To stop, press the “STOP” button.
The rollers will be lowered against the table.
Grinding control:
When the gear unit is in operation and the system is ready, a green dot will appear in the
“START” button and the grinding pressure control can be started.
Before start a proper setpoint range for the grinding pressure has to be set (ref. FLS instruction).
A green frame around the set point value field below the bar graph indicates that the set point
value can be changed.
Activating the set point value field and using the up-/down- keys sets the setpoint value until the
wanted set point value is obtained.
(The up-down keys can only be used in a period of 30 sec after activation of the value field.)
The range for the setpoint can be checked from parameter picture no. 3.
The upper/lower control limits for the hydraulic pressure can be set at parameter picture no. 4.
Activate the “START” button and the grinding pressure will start to rise. When the hydraulic
pressure is within the setpoint range and the delay time adjusted at parameter picture no. 3 has
expired, the system is In Operation.
During operation, the set point for the hydraulic pressure can be changed.
Remark!
In the control system is build in limits for the permissible range for the set point for the hydraulic
pressure.
If a set point value outside the range is selected, it will automatically be changed to the nearest
permissible value, see parameter picture no. 3.
From control picture No.2, the heating system can be started and stopped, when the system is in
Local Control Mode “LC MODE”.
A green dot in the “ON” button will indicate that the heating can be selected.
Press the “ON” button and the heating will be started as long as the button is indicating green.
From control picture No. 3, it is possible to stop the circulation pump if the filter in the circulation
line is blocked and the system is in “CC MODE”.
The circulation pump must be restarted within one hour; otherwise the lubrication unit and the
heating unit will be stopped due to an A2-alarm.
The following conditions must be present in order to stop the circulation pump:
If the circulation pump has been stopped for changing of the filter, it can only be restarted from
the control picture.
From this picture the pumps can be started and stopped, when the system is in Local Test Mode
“LT-MODE”.
A green dot in the “START” button will indicate that the pump can be started.
Activate the “START” button (colour changes from white to green) and the pump will be running
as long as the button is green.
Activate the “STOP” button to stop the pump (colour changes from green to white).
From this picture the Heating elements can be activated and de-activated, when the system is in
Local Test Mode “LT-MODE”.
A green dot in the “START” button will indicate that the Heating element can be activated.
Activate the “START” button (colour changes from white to green) and the Heating element will
be active as long as the button is green.
Activate the “STOP” button to de-activate the Heating element (colour changes from green to
white).
Alarm list
Whenever an alarm occurs, the alarm key in the top menu bar will change to red colour.
Switch to the alarm list by pressing the “ALARM” key. In the alarm list is shown all active
alarms, in chronological order.
For each alarm is shown: date, time, error number, alarm type (A1 = pre-warning and A2 = alarm
which will stop the machine), signal number and an alarm description.
When an alarm situation is corrected, the alarm can be removed by pressing the “RESET” key. If
there are more than one page with alarms, (15 alarms = 1page), it is possible to scroll up/down. In
order to scroll, press the “arrow” keys”.
A more detailed description of the alarms can be obtained by pressing the “?” key. When it is
pressed, a description of all alarms in the system, arranged by error number, will be shown on the
screen.
Further a screen, alarm history, showing the last 300 alarms is available. On this
Screen is all active alarms shown in yellow and corrected alarms are shown in Green. The screen
layout is identical with the alarm list.
All alarms will be latched in the control system and when the cause for an alarm has disappeared,
the alarm indication can be removed from the alarm list by activating the “RESET” key on the
screen.
On the picture is indicated the status of the digital signals between the local control panel (LCP),
and the central control system (CCS).
On the picture is indicated the status of the analogue signals between the local control panel
(LCP), and the central control system (CCS).
Parameter menu
When the correct password has been entered on the numeric keyboard, the parameters menu
picture is shown.
From the picture the listed functions can bee selected.
General:
If a value has to be changed, press the field showing the value, a numeric keyboard will appear,
and the new value can be entered.
Pressing the ESC button will remove the numeric keyboard, and the old value will be used.
When pressing the ENT button, the entered value will be checked to see if it is inside the allowed
limits, if it is outside the allowed limits the new value will not be accepted and the numeric
keyboard will stay on the screen. If the entered value is inside the allowed limits it will be
accepted, the numeric keyboard will disappear, and the field will show the new value.
Some values are checked against each other to check that they have the right proportions (one
value must be greater than the other). If the proportions are correct they will be accepted as above.
If the proportions are not correct the value input will be accepted and the input field will show the
new value, but a text “Fault! Enter new limit” will pop up. As long as the text is on the screen the
proportions are not correct, and the old values will be used by the PLC. As soon as one of the
values is changed to make the proportions correct the text will disappear and the input values will
be used by the PLC.
Parameter picture Alarm limits comprises adjustable alarm limits for the hydraulic pressure and
scaling factor for the layer thickness measurement.
The below specified values are for guidance only, the final adjustment is to be done during
commissioning.
If the limit is illegal Minimum 1 < Minimum 2, the text “FAULT: ENTER NEW LIMIT” will
appear, but the value will not change in the PLC. New values are only valid when no error text is
present.
Above limits for the accumulator pressures are as named common for all applied accumulator
pressures.
If the limit is illegal Accumulator pressure common maximum < Accumulator pressure
common minimum, the text “FAULT: ENTER NEW LIMIT” will appear, but the value will not
change in the PLC. New values are only valid when no error text is present.
21-Apr-08 KHP / SVo / MRSc
Local control panel HY-AM-1011 3.31
System structure and operation procedure 80009161 Ver.: 1.0
In parameter picture Override CCS signal it is possible to override the Local Permission signal
from CCS.
Local Permission:
When this signal is overridden it is possible to select Local Test Mode “LT MODE”,
or Local Control Mode “LC MODE” even if the Local Permission signal is not present from CCS.
The facility is foreseen to be used for system test and test of the individual components when CCS
is not installed.
In this mode the machine is only be operated by authorized personnel.
A green dot in the “ENABLE” button will indicate that the function can be selected.
Selection procedure:
Press the “ENABLE” button and the function will be active as long as the button is indicating
green.
Reset of selection:
Press the “RESET” button.
A power up of the cabinet will disable any selections made in this Parameter picture.
From parameter picture setpoint and delay time the allowable range for the set point for hydraulic
Grinding Mode pressure can be adjusted (ref. FLS instruction).
If the limit is illegal Upper limit < Lower limit, the text “FAULT: ENTER NEW LIMIT” will
appear, but the value will not change in the PLC. New values are only valid when no error text is
present.
The signal Grinding In Operation to CCS is delayed by the preset number of seconds keyed in on
the numeric keyboard.
From parameter picture Control limits the control limits for the hydraulic Grinding mode can be
set.
If P3<P1 or P4<P2 the text “FAULT: ENTER NEW LIMIT” will appear on the screen,
but the value will not change in the PLC. New values are only valid when no error text is present.
The below specified values are for guidance only, the final adjustment is to be done during
commissioning.
Range
P1 2 bar -10 to 10 bar
P2 1 bar -10 to 10 bar
P3 7 bar 0 to 20 bar
P4 5 bar 0 to 20 bar
Parameter picture Water cooling system comprises adjustable temperature limits for the water
cooling system on the Hydraulic unit.
The below specified values are for guidance only, the final adjustment is to be done during
commissioning.
If the on limit < off limit the text “FAULT: ENTER NEW LIMIT” will appear on the screen,
but the value will not change in the PLC. New values are only valid when no error text is present.
When the system is in Local Test Mode “LT MODE” it is possible to use the circulation pump for
filling or emptying of the oil tank.
The circulation pump can afterwards be started from the start/stop buttons.
REMARK! If the ENABLE function is selected, the safety interlocks from oil level and oil
temperature are cancelled.
A green dot in the “ENABLE” button will indicate that the function can be selected.
Press the “ENABLE” button and the function will be active as long as the button is indicating
green.
Reset of selection:
Press the “RESET” button.
From parameter picture Local test valves opening and closing of the solenoid valves Y01, Y02
and Y04 can be tested, when the system is in Local Test Mode “LT MODE”.
A green dot in the “ON” button will indicate that the function can be activated.
Press the “ON” button and the function will be active as long as the button is indicating green.
From parameter picture Local test pressure systems venting and test of the grinding pressure side
and of the lifting pressure side can be done. (Ref.: FLS instruction).
A green dot in the “START” button will indicate that the function can be selected.
GENERAL SPECIFICATION
Storage
Temperature -5 - 60°C
Humidity 0 - 75% non condensing
Operating
Temperature -5 to 40°C
Humidity 20 - 90% non condensing
Altitude above sea level < 1000 meters
Class and protection IP54
Power supply 380V 2ph 50Hz
Power consumption 1,0 kVA
Panel
-A1 1 HxWxD 1800x1200x400mm 8284.500 Rittal
1 Panel sides 8184.235
1 Plinth H=200 8602.200
1 Plinth H=200 8602.040
1 Utility lectern 4638.600
1 Diagram pocket 2514.000
2 Cable flange FMC25-M Fibox
17-07-07
Local control panel type ATOX-HY 6.03
Parts list 80009161 Ver.: 1.0
17-07-07
Local control panel type ATOX-HY 6.04
Parts list 80009161 Ver.: 1.0
17-07-07
Local control panel type HY-AM-11 8.05
Signals list 80009161 Ver.: 1.0
19/02/2008 KHP/SVo/FleJ
08:35:00
Local control panel type HY-AM-11 8.06
Signals list 80009161 Ver.: 1.0
19/02/2008 KHP/SVo/FleJ
08:35:00
STD: ED INT: KHP / KHP / FleJ DATE: 12-03-08 VER.: 1.0
Slot No. 0 Slot No. 1 Adr. Slot No. 2 Adr. Slot No. 3 Adr. Slot No. 4 Adr. Slot No. 5 Adr.
CPU Digtal input Digtal input Digital output Digital output Analog input
16 x 24 VDC 16 x 24 VDC 8 x Relay 8 x Relay 8 x 4-20mA
Term. Term. Term. Term. Term.
24VDC Supply Data.0 Circ. pump M01 Data.0 Hydraulic in Out.0 Circ. pump M01 Out.0 Oil tank temp. Ch 0
OK Ready operation Command 0-150 °C
IN 0 IN 0 VAC- VAC- I in 0+
-G02C41 -M01C41 -HY110A01C68 VDC 0 -M01C31 VDC 0 -N02T01 V/I in 0-
Panel Door closed Circ. Pump M01 Hyd. pump M02 Grinding pressure
Data.1 Return signal Data.1 Out.1 Command Out.1 0-400 bar Ch 1
IN 1 IN 1 VAC- VAC- I in 1+
-S05C41 -M01C61 -M02C31 VDC 1 -N01P01 V/I in 1-
VDC 1
Main valve Water cooling Heating E01 Layer thickness
Position Data.2 Data.2 command Y04 Out.2 Command Out.2 Ch 2
IN 2 IN 2 VAC- VAC- I in 2+
-D07Z41 -Y04C31 -E01C31 VDC 2 -B01L01 V/I in 2-
VDC 2
Roller 1 Hydr. pump M02 Heating E02
top Data.3 Ready Data.3 Out.3 Command Out.3 Ch 3
IN 3 IN 3 VAC- VAC- I in 3+
-D01Z41 -M02C41 -E02C31 VDC 3 V/I in 3-
VDC 3
Roller 2 Hyd. pump M02 Roller position
top Data.4 Return signal Data.4 command Y01 Out.4 Out.4 Ch 4
IN 4 IN 4 VAC- VAC- I in 4+
-D02Z41 -M02C61 -Y01C31 VDC 4 V/I in 4-
VDC 4
Roller 3 Pressure relief. Acc. press. cyl. 1
top Data.5 Data.5 Command Y02 Out.5 Out.5 0-400 bar. Ch 5
IN 5 IN 5 VAC- VAC- I in 5+
-D03Z41 -Y02C31 VDC 5 -N11P01 V/I in 5-
VDC 5
Heating E01 Acc. press. cyl. 2
Data.6 Ready Data.6 Out.6 Out.6 0-400 bar. Ch 6
IN 6 IN 6 VAC- VAC- I in 6+
-E01C41 VDC 6 -N12P01 V/I in 6-
VDC 6
Heating E01 Reset Acc. press. cyl. 3
Data.7 Return signal Data.7 Emergency Out.7 Out.7 0-400 bar. Ch 7
Circuit VAC- VAC- I in 7+
IN 7 -E01C61 IN 7 -A01X31 VDC 7 -N13P01 V/I in 7-
VDC 7
Data.8 Data.8
IN 8 IN 8
Heat protection
Data.9 E01 Data.9
IN 9 -E01T41 IN 9
Data.10 Data.10
IN 10 IN 10
Data.11 Data.11
IN 11 IN 11
Oil filter blocked
Data.12 Data.12
-D08P41 IN 12 IN 12
Oil Level
MIN 1 Data.13 Data.13
-D09L41 IN 13 IN 13
Oil Level
MIN 2 Data.14 Data.14
-D10L41 IN 14 IN 14
Data.15 Emergency
circuit OK Data.15
IN 15 -A01X41 IN 15
321HY110
I/O Addressing arrangement
80009161 9.05