You are on page 1of 1

PIPING AND WIRING INSTALLATION Wiring of Indoor Unit Connection

Installation Manual Obstacle (The wiring of indoor unit connection shall refer to individual’s installation
SAFETY PRECAUTIONS
ø Anode bar insert instruction for detail connection)
Hot water connection

300mm or
● Read the following “SAFETY PRECAUTIONS” carefully before installation of Domestic Hot Water Tank Unit (hereafter referred to as
“Tank Unit”).
For SDH07/09 models For SDH12/14/16 models

more
● Electrical works and water installation works must be done by licensed electrician and licensed water system installer respectively. Be Earth
sure to use the correct rating and main circuit for the model to be installed. Panasonic
Earth
● The caution items stated here must be followed because these important contents are related to safety. The meaning of each indication
used is as below. Incorrect installation due to ignorance or negligence of the instructions will cause harm or damage, and the serious-
ness is classified by the following indications.
‘ Booster heater
] lead wire
WARNING This indication shows the possibility of causing death or serious injury.

BOOSTER HEATER
CAUTION This indication shows the possibility of causing injury or damage to properties only. 3 way valve
“ lead wire
The items to be followed are classified by the symbols: Heating AB

3 WAY VALVE
Sensor
Symbol with white background denotes item that is PROHIBITED from doing. B side A side
lead wire

Symbol with dark background denotes item that must be carried out. or

SENSOR
[ 3-way valve mm nt
600 to fro
e
● Carry out test run to confirm that no abnormality occurs after the installation. Then, explain to user the operation, care and maintenance mor Sensor lead wire
as stated in instructions. Please remind the customer to keep the operating instructions for future reference.
● If there is any doubt about the installation procedure or operation, always contact the authorized dealer for advice and information. Booster heater
3 way valve lead wire
lead wire
WARNING Drain connection water
discharge (3/4"BSP)
1) Must engage an authorized dealer or specialist for installation. If installation is defective, it will cause water leakage, electrical
shock or fire. Connection (1/2"BSP) For SDF/SDC/MDF/MDC models
2) Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electrical shock Water supply valve
or fire. (field supply) Tee Joint
3) Use the attached accessories parts and specified parts for installation. Otherwise, it will cause the set to fall, water leakage, (field supply) ¥
fire or electrical shock. Sensor
4) Install at a flat horizontal, strong and firm location which is able to withstand the Tank Unit’s weight. If the location is slanting,
or strength is not enough the set will fall and cause injury. WARNING Tank OLP
5) For electrical work, follow the local national wiring standard, regulation and this installation instruction. An independent circuit
and single outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause This section is for authorized and licensed electrician / water
system installer only.
electrical shock or fire.
6) Only use the supplied or specified installation parts. Else, it may causes Tank Unit vibrate, water leakage, electrical shock or Be sure to switch off all power supply (Tank Unit power supply,
indoor unit power supply, heater power supply etc.) before
fire. Booster Heater
performing installation.
7) This Tank Unit can only be used in a close water system. Utilization in an open water system may lead to excessive corrosion
of the water piping, water leakage or under pressure to the Tank Unit. ¥. Install adjustable legs at bottom of tank (3 locations) then adjust the height until the unit stable. Earth
8) Do not make any purchase of electrical parts locally for installation, service, maintenance, etc. This should be done by a ø. Fix the anode bar into socket.
licensed electrician and an authorized dealer. Otherwise, it may cause electrical shock or fire. π. Install safety valve at water supply inlet, install drain appropriately. 3-way valve
[. Install 3-way valve at outlet tube of indoor unit, connect heating tube connection with tank pipe.
9) Do not branch the power from terminal block to heater tap. Overloaded terminal block will cause electrical shock or fire.

10) Keep plastic bag (packaging material) away from small children, it may cling to nose and mouth and prevent breathing. WARNING
11) For cold water supply has a backflow regulator, check valve or water meter with check valve, provisions for thermal expansion Be careful on 3-way valve connecting direction
of water in the hot water system must be provided. Otherwise it will cause water leakage. - “Default” condition is at Heating Side
- “On” condition is at Tank Unit
12) The piping installation work must be flushed before Tank Unit is connected to remove contaminants. Contaminants may
damage the Tank Unit components. “. Insert sensor until it touches securely end of socket, tighten the cap of socket so that it is not shifted. CHARGE THE WATER
13) The installation may be subjected to building regulation approval applicable to respective country that may require to notify (Refer bottom diagram)
the local authority before installation. WARNING
14) The Tank Unit must be shipped and stored in upright condition and dry environment. It may laid on its back when being
moved into the building. Make sure Tank Unit filled up with water before
switch on the power.
15) Work done to the Tank Unit after removal of electric cover secured by screws, must be carried out under the supervision of ]. Connect the cable between heater and OLP, which located inside electrical box as shown at below section.
authorized dealer and licensed installation contractor. (Wiring at Tank Unit – (Electrical Box) and Wiring at Indoor Unit) 1. Make sure all the piping installations are properly done.
2. Set the water supply valve “OPEN” and all hot water tap “OPEN”.
CAUTION WARNING 3. Start filling water to the Tank Unit. After 20~40min, water should flow out from hot water tap.
1) Installation work. Else, please contact your local authorized dealer.
Three people are required to carry out the installation work. The weight of Tank Unit might cause injury if carried by one Use cap tire cable (2 mm2) for wiring. 4. Switch ON the power supply of the Indoor unit. Then set the indoor control panel to “Tank Connection” to “Yes”.
For SDH series, 3 cables are needed.
person. After that, change operation mode to “Tank Mode”. Make sure water pump running.
While, for other models, 5 cables is needed.
2) Do not install Tank Unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at Else, please contact your local authorized dealer.
surrounding of the Tank Unit, it may cause fire. Fix the cables to the cord protector mountings with cable ties 5. Check and make sure no water leaking at the tube connecting points.
to ensure strain relief closely.
3) Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water leakage may happen and
may cause damage to properties of the user. ‘. Insert the cables of 3-way valve, sensor & heater from bushing at the bottom of indoor unit.
Guide the wire inside the indoor unit with refer to the installation instruction of indoor unit.
4) Select an installation location where it is accessible for maintenance.
* Please keep the space for maintenance purpose (Top: above 300mm / Front: above 600mm)
EXAMINE THE ANODE ONCE A YEAR
5) Do not install this appliance in a laundry room or other high humidity location. This condition will cause rust and damage to
To protect the pressure vessel an anode is placed inside the tank. The anode will, depending on the water quality, corrode. When diameter
the Tank Unit.
is approx. 8mm the anode must be replaced.
6) Make sure the power supply cord does not contact with hot part (i.e. water piping). High temperature may cause insulator or Wiring at Tank Unit – (Electrical box) It is easy to check and replace the anode
power supply cord damage hence electrical shock or fire. 1. Turn off power supply.
7) After installation, the installer is obliged to verify correct operation of the Tank Unit. Check the connection points for water BOOSTER HEATER 2. Close water supply valve.
leakage. If leakage occurs, it will cause damage to other properties. 3. Manually open the safety valve and drain approx. 2ltrs..
Earth Earth 4. Unscrew the anode, check and if necessary replace.
8) Ensure the correct polarity is maintained throughout all wiring. Otherwise, it will cause electrical shock or fire. TANK OLP

Capacity Dimension (mm)


Model
(Litre) Height Diameter
WH-TD20B3E5 198 1150 580
DISCHARGE OF WATER
1 8
WH-TD30B3E5 287 1600 580 1. Turn off power supply.
2 2. Close water supply valve.
Main components 3. Open safety valve, by turning knob counter-clockwise until it stays open.
1 Hot water outlet – 19.05 mm (3/4"BSP) 4. Open a hot water tap to allow air inlet.
2 Electrical box Earth
5. After discharge, close valve continue turning counter-clockwise until the valve snaps shut.
3 Sensor socket – 12.70 mm (1/2"BSP) 3
4 Flow inlet – 19.05 mm (3/4"BSP) Reset button
5 Return outlet – 19.05 mm (3/4"BSP) Safety cut-out Earth
4
6 Cold water inlet – 19.05 mm (3/4"BSP) PRECAUTION ON USAGE
Height

Thermostat
7 Threaded Sensor hole for connect solar
station – 12.70 mm (1/2"BSP) 7 BOOSTER HEATER ● When using hot water, it must be mixed with water.
8 Anode connector – 19.05 mm (3/4"BSP) Cap tire cable Please check the hot water’s temperature before using it.
TANK BOOSTER
(2mm2 × 3 wires) OLP HEATER (Hot water may cause scalding.)
Accessory parts 5
A. 3-way valve Cap tire cable After complete the installation, please pass this manual to customer.
B. Sensor 6 (2mm2 × 5 cable)
C. Installation manual Electric element
5/4"BSP
D. Safety valve
E. Adjustable legs x 3 Diameter
F. Anode bar * Must not change the volume knob. * Must not change the volume knob.
ENGLISH
Detail of Electric Box 147031 1
9
SDH series Other models PRINTED IN NORWAY

You might also like