You are on page 1of 4

TP8 Series

Automatic Booster Pump


Instruction Manual

ISO 9001 Certified


WALRUS PUMP CO., LTD.
OPERATION 5. The location must be dry with good
ventilation and adequate space.
6. Do not run without water actually
pumping. Do not operate hot water (more
than 60 °C ), or the other liquid except
normal water.
7. Be careful not to allow the foreign
matter (chips, dirt, sand, glue, etc)
into the pump, or the will damage and
shorten the life of pump.
8. Piping joints should be fitted carefully
to prevent leakage.
FIG.1 a. Leakage in the suction piping will
1. Make sure of using the right voltage. cause the pump does not function well.
2. Remove the check valve cap and pour b. Leakage in the discharge piping
water into the pump and suction will cause a high frequency ON
piping ,then secure the plug. /OFF motor operation while all the
3. Insert a screw driver cross into the faucet and valves are closed.
shaft slot , and turns the shaft 2-3 9. Keep the faucets opened fully to get
rounds to check if the pump runs more efficient operation. Never keep
normally , then open one faucet on continuous operation under the
the delivery side , the turn the power condition of half open.
switch ON.(FIG.1) 10. TO avoid your furniture damage, do
4. After the power switch on, the motor not install the pump on ceiling, carpet
should turn immediately . After a few or any place close to electrical
seconds, the water should be appliance, outdoor installation must
covered by tent.
delivered .
5. If the water does not be delivered
immediately turn the power OFF.
TROUBLE SHOOTING
Repeat step 2 and set power ON/OFF (Turn the power switch OFF before fixing.)
continuously to make the suction 1. MOTOR FAILS TO START OR
piping be filled with water. RESTART AFTER A SHORT-TERM
6. Once the water is pumped out, close RUNNING
the faucets on the delivery side to The overheating protector is mounted
check the automatic stopping and directly on the motor windings. It will
pumping operation. stop the motor automatically when the
motor temperature is up to abnormal,
IMPORTANT NOTE and restart the motor after the tempera-
1. Use the right voltage and wiring by ture back to normal in 20 minutes.
the connecting diagram. Motor must be (TP820 180W / TP825 370W / TP830A
grounded in compliance with applica- 750W)
ble electrical code to avoid accident. a. Check the electrical power source,
2. please use a sturdy foundation and fuse, and circuit breaker.
bolt the pump to it securely. b. Check if pump is locked by rust or
3. Be sure to arrange earthling or circuit foreign objects.
breaker against electric leakage. c. Check if the ventilation of the
4. The pump should be installed as close as location is bad for causing the
to the reservoir or well to avoid the low overheating of motor.
efficiency due to the long suction pipe.
~1~
2. PUMP CYCLES FREQUENTLY Coverage of Application:
WHILE ALL THE FAUCETS AND 1. Directly and automatically supply
VALVES ARE CLOSED: water to the building without roof
a. Check and fix the leakage in water tower.
discharge piping, faucets, and 2. Automatically increase pressure as
valves. soon as the insufficient water
b. Clean pump check valve (FIG.3-12) pressure in top floor.
which may be locked by foreign 3. To be used on supplying water for
objects. washing machine and heater if water
3. PRESSURE SWITCH FAILS TO pressure is too low.
FUNCTION 4. To drain accumulated water for civil
The pump's pressure switch has and architecture engineering, to be
been set accurately. Please do not try applicable to the skyscraper villa,
to adjust except by qualified personnel. pond and farm.
a. If the motor does not start after any 5. To be used on circulating water for
of the faucets or valves are garden and on supplying water for
opened, adjust the pressure auto car-washer.
setting screw to the "+" direction
(counterclock- wise) until the motor
starts.(FIG.2)
b. If the motor fails to stop after all
the faucets and valves are closed,
adjuts the pressure setting screw
to the "-" direction (clockwise) until
the motor stops.(FIG.2)
c. Repeat step (a) and (b) until the
pump work normally. FIG.2

SPECIFICATIONS
Model No: TP820 TP825 TP830A
Output(W) 180 370 750
Cycle(Hz) 50 / 60 50 / 60 50 / 60
Revolution 2820 / 3420 2820 / 3420 2820 / 3420
Delivery head(m) 10 /12 18 / 20 25 / 30
Suction head(m) 6 6 6
Total head(m) 23 / 26 32 / 40 45 / 44
Total capacity(L/min) 30 / 40 40 / 48 75 / 80
Pressure switch ON 0.9 / 1.2 1.8 / 2.0 2.0 / 2.0
( kg/cm² ) OFF 1.8 / 2.4 2.8 / 3.0 3.0 / 3.0
Inlet / Outlet mm(in) 20(¾") 25(1") 25(1")
N.W. (kg) 7.5 9.5 14

~2~
PARTS
NO. Part NO. Part NO. Part
1 Motor Shell 7 Screw 13 Check Valve-Cap
2 Shaft 8 Steel Ball 14 -
3 Mechanical Seal 9 Impeller 15 Pressure Tank
4 O Ring 10 Gasket 16 Gasket
5 Pump Casing 11 Flange 17 Pressure Switch
6 Cover 12 Check Valve-Set

FIG.3

TP820 180W / TP825 370W

TP830A 750W

CP70D0015D000EW0R03

WALRUS PUMP CO., LTD.


Web: www.walruspump.com