Upgrading switch firmware

=======================

Select option 'F' to go to the Firmware Configuration menu from


the Main Menu. An example of the Firmware Configuration Menu is:

Catalyst 1900 - Firmware Configuration

----------------------- System Information -----------------------------


FLASH: 1024K bytes
V8.01.00 : Enterprise Edition
Upgrade status:
No upgrade currently in progress.

----------------------- Settings ---------------------------------------


[S] TFTP Server name or IP address 171.71.112.242
[F] Filename for firmware upgrades cat1900.bin
[A] Accept upgrade transfer from other hosts Enabled

----------------------- Actions ----------------------------------------


[U] System XMODEM upgrade [D] Download test subsystem (XMODEM)
[T] System TFTP upgrade [X] Exit to Main Menu

Enter Selection:

Upgrading with a TFTP Server


============================

1 Copy the switch firmware file to the TFTP server.

2 Select option 'S' from the Firmware Configuration menu and


enter the IP address of the server where the switch upgrade
file is located.

3 Select option 'F' from the Firmware Configuration menu and


enter the name of the firmware-upgrade file.

4 Select 'T' from the Firmware Configuration menu to initiate


the upgrade.

5 Verify the upgrade is in progress by checking the Upgrade status


section of the Firmware Configuration Menu. If the upgrade is
in progress, the field reads "in-progress"

6 When the transfer is complete, the switch resets automatically


and executes the newly downloaded firmware.

Caution During the transfer of the upgrade file, the switch might not
respond to commands for as long as 1 minute. This is normal
and correct. If you interrupt the transfer by turning the
switch off and on, the firmware could be corrupted. If this
happens, follow the procedure described in "Using the
Diagnostic Console" in the chapter "Troubleshooting" of
the Installation and Configuration guide to restart the
firmware.

Upgrading with a TFTP Client


============================
1 Copy the switch firmware file to the TFTP client workstation.

2 On the TFTP client workstation, establish a TFTP session using


the IP address assigned to the switch.

3 Ensure that the TFTP client is in binary transfer mode.

4 At the command line, enter "put" and the filename.

5 Verify the upgrade is in progress by checking the upgrade status


section of the Firmware Configuration Menu.
If the upgrade is in progress, the field reads "in-progress".

6 When the transfer is complete, the switch resets automatically


and executes the newly downloaded firmware.

Caution During the transfer of the upgrade file, the switch might not
respond to commands for as long as 1 minute. This is normal
and correct. If you interrupt the transfer by turning the
switch off and on, the firmware could be corrupted. If this
happens, follow the procedure described in "Using the
Diagnostic Console" in the chapter "Troubleshooting" of
the Installation and Configuration guide to restart the
firmware.

Upgrading with XMODEM


=====================

1 Copy the switch firmware file to the system running the XMODEM application.

2 Select option 'U' from the Firmware Configuration menu to initiate the
XMODEM download.

3 When the first XMODEM request appears, use the appropriate command
to start the transfer from the application supporting XMODEM transfer.

4 When the transfer is completed, the switch resets automatically


and executes the newly downloaded firmware.

Caution During the transfer of the upgrade file, the switch might not
respond to commands for as long as 1 minute. This is normal
and correct. If you interrupt the transfer by turning the
switch off and on, the firmware could be corrupted. If this
happens, follow the procedure described in "Using the
Diagnostic Console" in the chapter "Troubleshooting" of
the Installation and Configuration guide to restart the
firmware.

Snapshot of Problem :

Diagnostic Console - Systems Engineering

Operation firmware version: 0.00.00 Status: invalid


Boot firmware version: 3.10

WARNING!!! Operation firmware is invalid.


Upgrade firmware to enable switch operation.
[U] Upgrade operation firmware (XMODEM)
[S] System debug interface

Enter Selection: U

The XMODEM protocol will be used to perform this firmware upgrade.


The user must initiate an XMODEM file transfer from the terminal
side using an appropriate terminal application specific command.

Do you wish to continue with the download process, [Y]es or [N]o? Yes

Erasing invalid flash - may take up to 1 minute.


Erasure completed.

Do you wish to upgrade at [9]600 (console speed) or [5]7600? 9600

Waiting for image at the configured baud rate...

After upgrading flash foll. screen comes :

Diagnostic Console - Systems Engineering

Operation firmware version: 9.00.06 Status: valid


Boot firmware version: 3.10

[C] Continue with standard system start up


[U] Upgrade operation firmware (XMODEM)
[S] System debug interface

Enter Selection: C

The system will take a minute to perform self test...

This command allows you to clear all passwords.

Do you wish to clear the passwords, [Y]es or [N]o? Yes

After clearing Password foll. screen comes :

Catalyst 1900 Management Console


Copyright (c) Cisco Systems, Inc. 1993-1999
All rights reserved.
Enterprise Edition Software
Ethernet Address: 00-D0-58-78-3A-40

PCA Number: 73-3122-03


PCA Serial Number: FAB0321333Y
Model Number: WS-C1912-EN
System Serial Number: FAB0323S01B
Power Supply S/N: PHI031300BB
PCB Serial Number: FAB0321333Y,73-3122-03
-------------------------------------------------

1 user(s) now active on Management Console.