Minimum Ventilation For Broilers

1. Purpose Of Minimum Ventilation 2. Minimum Ventilation Rates 3. Achieve Good Airflow And Volume

To provide a minimum level of air exchange


w Minimum
w ventilation is a timer not
temperature driven process.          
Ventilation for some minimum amount of
w   
  

Recommended minimum ventilation rates for 



w 
time is required to:







minimum ventilation are:






• maintain good air quality.

  
Live weight (kg)) Live weight (lbs) Minimum ventilation rates (m3/hr) Minimum ventilation rates (ft3/min)


• remove excess moisture. 0.050 0.11 0.080 0.047



0.100 0.22 0.141 0.083
Minimum
 
w 0.200 0.44 0.258 0.152     
  

ventilation is 0.400 0.88 0.435 0.256

recommended 0.600
0.800
1.32
1.76
0.589
0.731
0.347
0.430
for younger 1.000 2.20 0.864 0.509
If incoming airflow speed and volume is too
w
birds and in 1.400
1.800
3.09
3.97
1.112
1.343
0.654
0.790 low:
cool or winter 2.200 4.85 1.561 0.919
• cold air will drop directly on to the birds/litter.
weather 2.600 5.73 1.769 1.041
3.000 6.61 1.969 1.159 • litter will become wet and birds may get
conditions. 3.400 7.50 2.163 1.273
chilled.
3.800 8.38 2.352 1.384
4.200 9.26 2.535 1.492

4. Ensure House Is Tightly Sealed 5. Uniform Air Inlet Openings 6. Monitor And Evaluate Regularly

Open air inlets must


w At lower ventilation
w Monitor house pressure
w Complete regular
w
Ventilation
w
37.0°C be evenly distributed rates close some & air speed: evaluation of:
only works
36
through the house inlets to force the • For every increase in • air quality
effectively if 34
and be opened same volume of air negative pressure of • relative humidity
equally. through fewer inlets. 3-4 Pa (0.012-0.016 • signs of condensation
the house is 32

inches of water
adequately This will create
w • dust levels
column) air will travel
30

sealed and 28
uniform: ~ 1 m (3.3 ft) into the • litter quality
there are no 26
• volume of airflow house.
air leaks. 25.0°C • speed of airflow • Incoming air should be
This ensures
w 37.0°C • direction of airflow thrown into the centre
that airflow 36
• distribution of of the house.
speed and 34
airflow Use smoke tests
w

www.aviagen.com
volume 32
or cassette tape to
entering the confirm if airflow
direction and inlet
30

house are
controlled
28
February 2018 settings are correct.
Air leaks. Monitor bird
w
and correct. 26
Library photographs for teaching purposes.
25.0°C
Aviagen® and the Aviagen logo are registered trademarks of Aviagen in the US and other countries. behavior.
All other trademarks or brands are registered by their respective owners.
© 2018 Aviagen