Mesha Battery performance

Drive Cycle Bench Test Report


Date of Data Collection:16/04/21
Lead Acid
Constant Power Drive Cycle 800W – with fan

Figure 1 Voltage drops immediately after 5 mins of loading - 25A

Voltage vs Time
60

55

50

45

40

35

30

25
03:14:24 PM 03:21:36 PM 03:28:48 PM 03:36:00 PM 03:43:12 PM 03:50:24 PM

Voltage drop from 48 to 43 could indicate one of the cells malfunctioned.


Time is between 3:18-3:45 for the cycle.
Total energy used is 381.6Wh.