Flowline to CGDF

Length 3300 m
Margin 20%
Length 4000 m
Length 13120 ft
Length 131.2 100 ft

Size 14" Wall thickness 12.7 mm

Summer
Temp. at wellhead
Flow Pressure seprator psi/100ft
Case 1 110 MMSCFD 925 psig at CGDF 230 F 42 0.320122
Case 2 110 MMSCFD 600 psig at CGDF 230 F 75.9 0.578506
Case 3 40 MMSCFD 400 psig at CGDF 230 F 14.6 0.11128

Size 12" Wall thickness 12.7 mm

Summer
Temp. at wellhead
Flow Pressure seprator psi/100ft
Case 1 110 MMSCFD 925 psig at CGDF 230 F 72 0.54878
Case 2 110 MMSCFD 600 psig at CGDF 230 F 122.4 0.932927
Case 3 40 MMSCFD 400 psig at CGDF 230 F 24 0.182927

Size 10" Wall thickness 12.7 mm

Summer
Temp. at wellhead
Flow Pressure seprator psi/100ft
Case 1 110 MMSCFD 925 psig at CGDF 230 F 193 1.471037
Case 2 110 MMSCFD 600 psig at CGDF 230 F 277.9 2.11814
Case 3 40 MMSCFD 400 psig at CGDF 230 F 66 0.503049
SCH 60

Pressure
Velocity, m/s Velocity, ft/s Velocity criterea drop Check

<60 ft/s psi/100ft


7.37 24.1736 OK 967 5.802 OK
11.05 36.244 OK 675.9 4.0554 OK
5.8 19.024 OK 414.6 2.4876 OK

SCH 60

Velocity, m/s Velocity, ft/s Velocity criterea Crietera Check

<60 ft/s psi/100ft


8.57 28.1096 OK 997 5.982 OK
13.45 44.116 OK 722.4 4.3344 OK
7.06 23.1568 OK 424 2.544 OK

SCH 60

Velocity, m/s Velocity, ft/s Velocity criterea Crietera Check

<60 ft/s psi/100ft


12.28 40.2784 OK 1118 6.708 OK
19.2 62.976 NOT OK 877.9 5.2674 OK
10.05 32.964 OK 466 2.796 OK