CAR TOP INSPECTION BOARD

HARDWARE MANUAL
FX-CAN Hardware Manual V1.10

Publisher ARKEL Elektrik Elektronik SAN. ve TİC. A.Ş.


Eyüp Sultan Mah. Şah Cihan Cad. No:69 Sancaktepe/Istanbul 34885 TURKIYE
TEL : +90(216) 540 67 24-25
Fax : +90(216) 540 67 26
E-mail: info@arkel.com.tr
www.arkel.com.tr
Date of issue 07.2020

Document version V1.10

This document has been created to be a guide for Arkel customers. Reproduction, transfer, distribution or storage of part or
all of the contents in this document in any form without the prior written permission of Arkel is prohibited. Arkel reserves
the right to make changes and improvements to any of the products described in this document without prior notice.

Arkel is not responsible for those mistakes that may be found in this manual and for the damages that they may cause.
FX-CAN Hardware Manual V1.10

1. FX-CAN Overview
FX-CAN is a board that provides control of the inputs and outputs (Car calls, overload, car light etc.) in the elevator car by the
serial communication with the control card. Serial communication saves many cables between the control card and the cabinet.
Inputs/outputs with Arcode / ARL-700 systems can be assigned to the desired features.
General
Dimensions
Width × Length × Height (mm) 190 x 140 × 34
(All female terminals are plugged in)
Operating Temperature 0 - 60 °C
Weight 273gr.
Electrical Characteristic
Normally 24VDC (18-30VDC)
Supply voltage
Battery 12V 1.2Ah (Built-in battery charger)
1,1W (Stand-By)
Power consumption
7,1W (Max.) (All calls, Outputs, Battery charging are active.)
Gray/Binary Max. current is 22mA at 24V
7Segment 30 mA output current per one-segment (short
Display outputs
circuit protected)
31,32,02 30 mA output current (short circuit protected)
10 Programmable inputs
Inputs 500,501 (Inspection operation Input current 6,2mA at 24VDC for one input
buttons)
LS(LiftSense)
Max switching voltage 250VAC/30VDC
3 programmable relays
Max switching current 3A
Outputs
Car light relay output 220VAC (3A fuse protected)
Car fan relay output
16 call button inputs and led Inputs active with 0Vdc (-),
Calls
outputs Led outputs short circuit protected
Emergency light output 12V (max. 200mA)
Alarm button Active with 0Vdc (1000)
Gong output 8R/0.5W speaker
Buzzer output 8R/0.5W speaker
Continuous output with battery backup in case
Magnetic switches supply output ML0 (Max. 200mA)
of power supply failure
• Programmable inputs (804, 805, fan, photocell, etc.); 500,501 inputs; LiftSense input (LS)
• Car fan, car light outputs
• Built-in battery charger
• Alarm button input
• Emergency light output
• Gong output
• Buzzer output
• Magnetic switches supply output
• 7-Segment/Gray/Binary indicator outputs
• Up/Down direction arrows and out of service display outputs
• Car call button connection
• Programmable relay outputs (Door open, Door close etc.)

2. FX-CAN Technical Parameters


2.1. Display Outputs
It is possible to get the outputs for 7-Segment, gray, binary from the indicator outputs. The connection diagrams of gray,
binary, common anode 7-Segment indicators and 31-32-02 outputs are shown in the figure below.
FX-CAN Hardware Manual V1.10

2.2. Programmable Inputs and Programmable Relay Outputs


FX-CAN has 3 programmable relay outputs, 10 programmable inputs.

2.3. Calls
FX-CAN has 16 calls button inputs (active low) and led outputs. Led outputs are short-circuit protected.

2.4. Other Connections


Connection diagrams of inspection operation buttons (500,501), LiftSense input (LS), magnetic switches supply output
(MLO), alarm button (ALB), gong, call active (SPE) outputs, battery connection (Built-in battery charger), car light and car fan
are as follows.
FX-CAN Hardware Manual V1.10

* Volume level on SPE output can be adjusting via trimmer potentiometer.


* The battery connection must be done for alarm button, gong output and emergency light output to work properly.

3. FX-CAN Mechanical Dimensions

You might also like