MSP-16, MSP-32
CALL CARD FOR LANDING FLOORS
IN PARALLEL INSTALLATION SYSTEMS

HARDWARE MANUAL
MSP-16, MSP-32 Hardware Manual V1.10

Publisher Arkel Elektrik Elektronik San. ve Tic. A.Ş.


Eyüp Sultan Mah. Şah Cihan Cad. No:69 Sancaktepe/Istanbul 34885 TURKIYE
Tel: (+90 216) 540 03 10-11-12
Fax: (+90 216) 540 03 09
E-mail: info@arkel.com.tr
www.arkel.com.tr
Date of issue 07.2020

Document version V1.10

This document has been created to be a guide for Arkel customers. Reproduction, transfer, distribution or storage of part or all
of the contents in this document in any form without the prior written permission of Arkel is prohibited. Arkel reserves the
right to make changes and improvements to any of the products described in this document without prior notice.

Arkel is not responsible for those mistakes that may be found in this manual and for the damages that they may cause.
MSP-16, MSP-32 Hardware Manual V1.10

1. Overview
MSP-16 and MSP-32 boards are designed to collect the calls coming from landings for the systems which have 16 floors or
less. Also, they are designed for the control of call leds, displays (direction, floor number information).
The landing calls are controlled in MSP-16 board up to 16 floors with single button, and up to 9 floors with double button. The
landing calls are controlled in MSP-32 board up to 16 floors with double button.
These boards communicate with ARL-700 controller board over Canbus line, then all these functions are controlled by
ARL700.
General
Dimensions
165 x 120 × 42(MSP-16)
Width × Length × Height (mm)
165 x 120 × 52(MSP-32)
(All female terminals are plugged in)
Operating temperature 0 - 60 °C
199gr. (MSP-16)
Weight
257gr. (MSP-32)
Electrical Characteristics
Supply voltage 24VDC (18-30VDC)
MSP-16 1W at 24V (Standby)
3.5W at 24V (Max. power consumption)
Power consumption
MSP-32 1.7W at 24V (Standby)
5.8W at 24V (Max. power consumption)
Gray/Binary (M0,M1,M2,M3) Max.100 mA output current for each at 24V
400mA current for each segment (Short-
7Segment (Common anode display)
Display outputs circuit protected)
Direction arrows, Out of service display Preferable via jumper on board as +/- Over-
outputs (31-32-02) current protected(300 mA)
16 pcs. (MSP-16)
Call input current 5.1mA (for each call at
32 pcs. (MSP-32)
Calls 24VDC)
(Call inputs, call led outputs and call detected
Outputs are short-circuit protected
buzzer output)

• 7Segment/Gray/Binary display outputs


• Down/Up direction arrow outputs
• Out of service display output
• 16pcs. call inputs and led outputs on MSP-16 board (16 floors single button, up to 9 floors double button up&down
collective)
• 32pcs. call inputs and led outputs on MSP-32 board (10-16 floors double button up&down collective)

2. Technical Parameters
2.1. Display Outputs
It is possible to get 7-Segment, Gray and Binary code outputs from display outputs. The necessary adjust is performed by using
the dipswitches on the board. When the display with Gray or Binary code output and common anode 7-Segment outputs are
used, the necessary connections must be done as shown in the following figures. The outputs are short-circuit protected.
MSP-16, MSP-32 Hardware Manual V1.10

2.2. Call Inputs


There exist 16 pcs call inputs on MSP-16 and 32 pcs call inputs on MSP-32 board. The call button inputs, led outputs and
buzzer output (BP) when the call is detected connections of boards must be connected as shown in the figure below. All led
outputs are short-circuit protected.

2.3. Down-Up Direction Arrow and Out of Service Outputs


The outputs are preferable as + and – switching. It is possible to use it in different ways via jumper on board. The jumper
position depending on the different usage is shown in the following figure. These outputs are over-current protected.