MSP-16, MSP-32
CALL CARD FOR LANDING FLOORS
IN PARALLEL INSTALLATION SYSTEMS
HARDWARE MANUAL
MSP-16, MSP-32 Hardware Manual V1.10
This document has been created to be a guide for Arkel customers. Reproduction, transfer, distribution or storage of part or all
of the contents in this document in any form without the prior written permission of Arkel is prohibited. Arkel reserves the
right to make changes and improvements to any of the products described in this document without prior notice.
Arkel is not responsible for those mistakes that may be found in this manual and for the damages that they may cause.
MSP-16, MSP-32 Hardware Manual V1.10
1. Overview
MSP-16 and MSP-32 boards are designed to collect the calls coming from landings for the systems which have 16 floors or
less. Also, they are designed for the control of call leds, displays (direction, floor number information).
The landing calls are controlled in MSP-16 board up to 16 floors with single button, and up to 9 floors with double button. The
landing calls are controlled in MSP-32 board up to 16 floors with double button.
These boards communicate with ARL-700 controller board over Canbus line, then all these functions are controlled by
ARL700.
General
Dimensions
165 x 120 × 42(MSP-16)
Width × Length × Height (mm)
165 x 120 × 52(MSP-32)
(All female terminals are plugged in)
Operating temperature 0 - 60 °C
199gr. (MSP-16)
Weight
257gr. (MSP-32)
Electrical Characteristics
Supply voltage 24VDC (18-30VDC)
MSP-16 1W at 24V (Standby)
3.5W at 24V (Max. power consumption)
Power consumption
MSP-32 1.7W at 24V (Standby)
5.8W at 24V (Max. power consumption)
Gray/Binary (M0,M1,M2,M3) Max.100 mA output current for each at 24V
400mA current for each segment (Short-
7Segment (Common anode display)
Display outputs circuit protected)
Direction arrows, Out of service display Preferable via jumper on board as +/- Over-
outputs (31-32-02) current protected(300 mA)
16 pcs. (MSP-16)
Call input current 5.1mA (for each call at
32 pcs. (MSP-32)
Calls 24VDC)
(Call inputs, call led outputs and call detected
Outputs are short-circuit protected
buzzer output)
2. Technical Parameters
2.1. Display Outputs
It is possible to get 7-Segment, Gray and Binary code outputs from display outputs. The necessary adjust is performed by using
the dipswitches on the board. When the display with Gray or Binary code output and common anode 7-Segment outputs are
used, the necessary connections must be done as shown in the following figures. The outputs are short-circuit protected.
MSP-16, MSP-32 Hardware Manual V1.10
3. Mechanical Dimensions