You are on page 1of 1

Automatic Analysers: Oillab Range

OilLab 715
Reid Vapour Pressure
CH-6864 Arzo,Mendrisio, Switzerland

www.lin-tech.ch – info@lin-tech.ch
Linetronic Technologies SA

tel. +41 91 6300703, fax +41 91 6300719


Via Onorio Longhi 2

OilLab 715 LT/RC-179000-A+B/M

ASTM D323 • B ath made in stainless steel suitable Accessories


IP 69 for the accommodation of up to two (2) • L AB-100-371/50: silicone oil,
ISO 3007 vapour pressure cylinders according can of 25 litres
to ASTM specifications • T-AS18C: thermometer ASTM 18C
ASTM D323 - IP 69 - ISO 3007
• B ath temperature range from ambient • L AB-102-013: flexible Junction for O 2
Vapour Pressure of Petroleum Products
to +80°C ±0.1°, filling level 20 litres. • LT/RC-179000/M:
(Reid Method) Procedure B • M otorized stirrer with shaft , drain tap Reid Cylinder - Liquid Chamber - One
The test method covers the determination • E lectric immersion Heather controlled Opening LT/RC-179000-A/M - ASTM D323
of vapour pressure of gasoline, volatile by PID system · made in stainless steel
crude oil, by means of three procedures: • D rive system for swing gently the vessel · i n one end of the liquid chamber
A, B and C. in horizontal position an opening of approximately ½” shall
The OilLab 715 grant the determination • S ecure handle cover for open bath be provided for coupling with the vapour
in conformity with the procedure B • B ath equipped with a Touch screen panel PC chamber
(horizontal bath) on petroleum products · TFT/LCD 8” · t he inner surface of the coupling end shall
having Reid Vapour Pressures below 180 · 40 Gb HD be sloped to provide complete drainage
kPa (26 psi). · Resolution 1024 × 768 and 16M colours when inverted
· 2 × USB Ports for connecting pen drive · t he other end of the chamber shall
and printer be completely closed
• T he dedicated software manages:
• R eid Cylinder - Vapour Chamber
· T he bath temperatures by means LT/RC-179000-B/M - ASTM D323
of a PT100 sensor class
· made in stainless steel
· A that can be displayed in °C / °F,
· lower coupling
including the over temperature safety alarm
· u pper ½” groove with a ¼” reducing cap
• 2 (two) electronic sensors, pressure
for pressure gauge
transducers / electronic pressure gauges
supplied for the coupling to the test vessels
• C ables and connectors
• D edicated software for real time monitoring
and recording that includes:
· Display of the pressure in bar / psi / Kpa
· Graph creation in real time during the test
· Invalid test indication
· Export of files in xls / pdf / jpg format
· Calibration up to 100 points
• P ower supply: 220Vac 50/60Hz