Technical Data - Fan Model APS1004BA7/19

Location: 1 Designation:

Performance - Required Actual


Air Flow : 34999.20 m³/h Air Flow: 35522.17 m³/h
Static Pressure : 150 Pa Static Pressure: 154 Pa
Selection Pressure: 150 Pa Total Pressure: 250 Pa
Installation Type: TYPE D
Air Density: 1.20 kg/m³
- Atmos. Temp: 20 °C
- Altitude: 0m
- Humidity: 0.0 %

Fan Data
Catalogue Code: APS1004BA7/19 (APS1004BA7H040)
Description: APS Series In-Line Smoke Spill

Diameter: 1000 mm Hub: 250 mm


Impeller Type: Axial Pitch: 19°
Blade Material: Aluminium Blades: 7
Speed: 1440 r/min @50 Hz Form: B
Power, Abs: 3.36 kW Peak: 3.59 kW
Input Power: 3.79 kW
Efficiency Total: 73.3% Static: 45.4%
Fan Weight: 121.0 kg

Motor Data (at STP)


Motor Type: S/Spill Class H
Electrical Supply: 380V 3ph 50Hz
Motor Frame: D112M
Motor Power: 4.00kW
FLC/Start: 8.96A / 53.73A
Motor Speed: 4 pole
Motor Efficiency:

Energy Efficiency, NCC/BCA Vol. 1, Table J5.2 compliant


+ 2006 - 2009
+ 2010 - 2012
+ 2013 - 2016
+ 2015 - 2016 Carpark
Sound Data
Spectrum (Hz): 63 125 250 500 1K 2K 4K 8K dBW dB(A) @ 3m
Inlet (dB): 93 93 96 96 94 91 89 82 102 78
Outlet (dB): 87 90 93 95 96 92 87 79 101 79

Sound levels are quoted as in-duct values. dB(A) values are average spherical free-field for comparative use only.

Energy Sustainability Data


Hours Per Day: 24 Annual Electricity Cost ($): 5621.8
DaysPerYear: 366 Annual GH Gas (Tonnes): 51.5
CO2 per kWh (kg): 1.467 Annual Carbon Usage (Tonnes): 14.0
Cost per kWh ($): 0.16

As part of our continuous improvement processes, Fantech reserves the right to Printed 8/23/2019 10:13:09 AM
make changes in design or specification to products without notice.
Page 1 of 2
Represented by:
Fantech Pty. Ltd.
A.B.N. 11 005 434 024
42-62 Pound Road West
Dandenong South VIC 3175
Telephone: +61 (03) 9554 7845
Facsimile: +61 (03) 9554 7833
E-mail: info@fantech.com.au
Version 5.5.8 Copyright © 2010-17 Elta Group

Drawing for Fan model APS1004BA7/19

Location: 1 Designation:

As part of our continuous improvement processes, Fantech reserves the right to Printed 8/23/2019 10:13:10 AM
make changes in design or specification to products without notice.
Page 2 of 2
GENERAL
CATALOGUE
Duct Mounted.qxd 4/03/2008 3:55 PM Page 31

ADJUSTABLE PITCH AXIAL FLOW FANS

FEATURES ANCILLARY EQUIPMENT


The AP Series of duct mounted adjustable pitch axial flow fans is
available in the following variants:-
O
AP Series - direct-drive
O
APV Series - direct-drive vertical mounted
O
APS Series - direct-drive smoke-spill MF - Matching flange
C..P - Circular silencers Vibration isolators
O
APB Series - belt-drive Ref. H-4/8 Ref. I-1 Ref. J-4
O
BFA Series - bifurcated, direct-drive
Construction
The casings are of mild steel, hot-dip galvanised after
manufacture. Impeller blades shall have an aerofoil section and
be pressure die-cast aluminium, injection-moulded glass-
reinforced plastic or nylon. Anti-static blades for hazardous F - Mounting foot IC - Inlet cone FG - Finger guards
applications up to 1400mm diameter, are also available. Ref. J-6 Ref. J-7 Ref. J-9

Motors
Type - squirrel cage induction motor which can be selected to
suit virtually any specification.
Electricity supply - single or three-phase to suit a wide range of
voltages and frequencies. Inverter
Bearings - ball. Ref. L-9
See pages N-3/4 for details on motors.
Motors to meet Australian Ex e, Ex d, Ex n or D.I.P. Standards
can be fitted. SMOKE-SPILL APPLICATIONS
Internal Thermal Protection The APS Series has been tested to meet the air performance
Can be provided as an optional extra. and high temperature test requirements of Standards
AS/NZS1668.1:1998 and AS/NZS4429:1999; both tests are
Testing mandatory.
Air flow testing:- For advice on smoke-spill wiring requirements refer to the above
315-1000mm diameter - BS848:Part 1, 1980 Standards.
1250-2000mm diameter - ISO5801:1997
See page C-7 for details of the smoke-spill range available.
Noise testing all sizes to BS848:Part 2, 1985

Special Features
Suitable for a wide range of applications, ranging from handling
HOW TO ORDER
ambient filtered air to hot, toxic and noxious gases. -
Hazardous fume applications
AP Series fans can be made to accommodate requirements for AP - direct drive
APV - vertical
corrosive fume and explosion risk applications. Special coatings APS - smoke spill
and alternative materials, such as stainless steel, are available APB - belt drive
as well as increased safety motors and anti-static impellers. Our BFA - bifurcated
sales engineers are able to assist with requirements, which must Fan diameter in cm
be specified at time of quotation. Fan speed, no. of poles
Hub diameter code
Wiring Diagram A =150 D= 400
See pages M-6/7, diagrams DD 1, 2, 3, 7, 8, 9. B = 250 F = 550
C = 350 G = 255
Weights Aluminium blades, A
See pages C-112/113 to determine unit weights. GRP, P
Nylon, N
Dimensions Antistatic blades, E
See pages C-110/111 for dimensions. No. of blades
Blade pitch angle, deg.

© FANTECH 2008 DUCT MOUNTED FANS B-31


Duct Mounted.qxd 4/03/2008 3:55 PM Page 32

AXIAL FLOW FANS QUICK SELECTION GRAPHS


The quick selection curves on these pages are designed to SUGGESTED SPECIFICATION
assist users to determine the fan diameter, speed, approximate
noise level and dimensions of the fan to meet the specified duty. The axial fans shall be of the AP/APV/APS/APB/BFA design(s)
as manufactured by Fantech Pty. Ltd..
Refer to Section C for detailed selection information. All performances shall be based upon BS848:Part 1, 1980 or
Detail including the number of blades and power absorbed is ISO5801:1997 and BS848:Part 2, 1985.
shown on pages C-11/109 or is available from the Fantech CD
program. Casings shall be hot-dip galvanised mild steel. Impellers shall
be of aerofoil section glass-reinforced plastic (GRP), nylon, or
B Pages C-2/8 provide detailed information on these products.
An example of how to use the curves is shown on page C-9.
aluminium; GRP is standard where selection permits.

The dimensions for all fans are on pages C-110/111.


Weights can be determined from details on pages C-112/113.

Model Numbers
O
AP - direct-driven; 315 to 2000mm diameter
O
APV - direct-driven; 315 to 2000mm diameter
O
APS - direct-driven; 315 to 2000mm diameter
O
APB - belt driven; 315 to 2000mm diameter
O
BFA - bifurcated; 400 to 1250mm diameter

2 Pole
3000 48 rev/sec
2000
95
91
1000 88
80 92
80 92
pSF - Fan Static Pressure, Pa

600 90
71 75
78 0802
400 65 0712
70 0632
0502 0562
200 0312 65 0402
em
st s
Sy ine
L
100

60 68 71 80 78 94 95 91

0.2 0.4 0.6 1.0 2.0 4.0 6.0 10.0 20.0 30.0
qV - Volume Flow, m /s3
dB(A) @ 3m: Inlet Side =

4 Pole
2000 24 rev/sec
92
87
1000
90
600 83 85
pSF - Fan Static Pressure, Pa

Lin stem

69 78
400
es

75
Sy

73 69
68 71
68
200 65 1254 1404
64 0804 1004
63 0634 0714
0564
56 52 0504
100 51 49 0404
0314 49 55 64 67 71 73 73 78 88 93
60
0.2 0.4 0.6 1.0 2.0 4.0 6.0 10.0 20.0 40.0 60.0
qV - Volume Flow, m /s
3
dB(A) @ 3m: Inlet Side =

B-32 DUCT MOUNTED FANS © FANTECH 2008


Duct Mounted.qxd 4/03/2008 3:55 PM Page 33

AXIAL FLOW FANS QUICK SELECTION GRAPHS

6 Pole
1000 96 16 rev/sec
86 90
82
600
78 95
400 88
81
Lin tem

80
pSF - Fan Static Pressure, Pa

B
es
s

72 75
Sy

200 63 67

66 59 1606 1806 2006


62 1406
63 1256
59 58 1006
100 54 0806
0716
56 56 0636
0566
60 48 0506
0406 45 51 57 61 67 65 70 76 81 83 88 92
0316 40
40
0.2 0.4 0.6 1.0 2.0 4.0 6.0 10.0 20.0 40.0 60.0 100.0
qV - Volume Flow, m /s
3
dB(A) @ 3m: Inlet Side =

8 Pole
600 12 rev/sec
86
400 78 82
74 77
72 74
71
Lin tem
pSF - Fan Static Pressure, Pa

71
200
es
s
Sy

63 61

1258 1408 1608 1808 2008


57 60
100 1008
58 58 0808
56 51 0718
60 0638
51 59 62 62 71 75 75 79 83
40
0.6 1.0 2.0 4.0 6.0 10.0 20.0 40.0 60.0 100.0
qV - Volume Flow, m /s 3
dB(A) @ 3m: Inlet Side =

10 Pole
400 10 rev/sec
81
78
78
72 75
70
200
pSF - Fan Static Pressure, Pa

em 1601 1801 2001


st s
Sy ine
100 L

60 71 75 78

50
6.0 10.0 20.0 40.0 60.0 80.0
qV - Volume Flow, m /s
3
dB(A) @ 3m: Inlet Side =

© FANTECH 2008 DUCT MOUNTED FANS B-33