Professional Documents
Culture Documents
Operation Manual: Blower Heated Regeneration Adsorption Air Dryer
Operation Manual: Blower Heated Regeneration Adsorption Air Dryer
使用说明书
Operation Manual
杭州力诺机械设备有限公司
HANGZHOU LINUO MACHINERY CO.,LTD
目 录
1、产品简介…………………………………………………………………1
Introduction
2、工艺流程图及流程说明 ………………………………………………2
Process diagram& introduction
3、安装与操作维护 ………………………………………………………4
Installation and Maintenance
4、常见故障检修 …………………………………………………………7
Common Malfunction And Maintenance
5、控制系统说明 ………………………………………………………… 9
Control System Introduction
6、售后服务 ………………………………………………………………14
After sales service
1、产品简介(鼓风热再生吸干机)
警告 Warning
连接鼓风热再生吸附式干燥机的电线必须符合国际(IEC)和地方上的法
规和标准,并与设备铭牌上标示的电压相符,电线的连接必须由专业电工人员
操作。
The electric wire connection of Blower purge regeneration adsorption air dryer should be
in accordance with international (IEC) and the nation standard, also should keep in
accordance with nameplate indicated voltage, the electric wires should be connected by the
professional electrician.
1
2、工艺流程图及流程说明 Process diagram& introduction
2
2.1 工艺流程说明 Process Description:
1)上半周期:A 塔吸附、B 塔加热再生阶段
TowerA adsorption、Tower B heating regeneration stage
≤38℃的饱和压缩空气,经由 K1 阀进入 A 塔吸附干燥后经 CV1 至后置除尘过滤器过滤,输
出无尘干燥的压缩空气。当 A 塔进行吸附干燥的同时,B 塔进行再生工作,此时 B 塔内的压缩
空气先经 V2 泄压阀泄压降至大气压,然后鼓风机启动、加热器启动,鼓风机吸入环境大气经加
热器加热至设定再生温度经 K7、K10 阀 进入 B 塔进行加热再生,加热再生气经 K4、K5 排到大
气中 。
The saturated compressed air ( ≤ 38 ℃ ) passes through K1 valve and enters the Tower A for
adsorption and drying ,then passes through CV1 valve to the after filter (dust removal filter) for filtration,
and outputs dust-free and dry compressed air. When Tower A is adsorbing and drying,and the Tower B is
regenerating,at this time the pressure of compressed air of Tower B is reduced to atmospheric pressure
through the V2 relief valve, then the blower and heater are started.The ambient air is suctioned into by the
blower and heated by the heater to the preset regeneration temperature ,the heated air pass through the
K7、K10 valve and then enters tower B for drying and regeneration ,the heated regeneration gas pass
through K4、K5 valve and discharge into the atmosphere air .
2)上半周期:A 塔吸附、B 塔吹冷再生阶段
Tower A adsorption、Tower B cold -blowing regeneration stage
B 塔经过一定时间的加热干燥后,塔内的吸附剂得以再生;通过 PLC 智能控制其控制再生阀
的切换。此时鼓风机出口气体经 WE/2 风冷却器降温后的空气经 K6、K4 阀与吸附气流相同的方
向(自下而上)进入 B 塔吸附床进行吹冷再生,塔内的热空气被鼓风机吸出流经 K10、K8 阀,
进入 WE/1 风冷却器降温并带走吸附剂内的热量,使鼓风机作闭式循环工作,此时温度降低至最
佳吸附效果的温度。为后续的吸附提供低露点保障。
After a certain time of heating and drying, the adsorbents in tower B can be regenerated ,the
switching of regeneration valve is intelligently controlled by the PLC control.At the same time, the outlet
gas of blower enters the WE/2 air cooler for cooling and the cooled air pass though the K6、 K4 valve
and enters the adsorption bed of Tower B in the same direction as the adsorption air flow (from bottom to
top) for cold blowing regeneration , the hot air in the tower is sucked out by the blower and pass through
K10、K8 valve ,and then enters the WE/1 air cooler for cooling and takes away the heat of adsorbent,
make the blower work in a closed cycle,at this time, the temperature is reduced to the temperature that
can produce the best adsorption effect.It guarantees low dew point for subsequent adsorption.
警告 Warning
严禁在未开机情况下长期通气,以免吸附剂失效。
It is strictly prohibited to keep ventilation under the condition of no
警告 Warning
在开始维修之前,请先断开电源并将设备泄压
Please cut off the power and release the pressure of the
equipment before the maintenance.
◆ 控制气系统输出压力为 0.5∽0.6 MPa 的范围; 检查程控器的指示信号与输出信号是否异常;
观察干燥塔上的压力表、温度表,判断程序运行是否正常。
The outlet pressure range of control air system is 0.5-0.6Mpa; Check whether the indicating signal
and output signal of the program controller are normal;Observe the pressure gauge and
thermometer on the drying towers to judge whether the operation is normal.
◆ 本设备投入运行后,应经常检查各种显示仪器仪表,并要定期校验。
After the equipment is put into operation, all kinds of display instruments should be checked
frequently and calibrated regularly.
◆ 控制器应经常检查,保持电器柜清洁,防止积灰及强磁场干扰。如发现控制器显示异常,
则应按“常见故障检修”有关要求处理。再则,应由专业人员检修。
The controller should be checked frequently and keep the electrical cabinet clean,to prevent it from
the dust accumulation and strong magnetic field interference.If find the controller is abnormal,it
should be handled according to the requirements of "Common Malfunction And Maintenance".
Moreover, it should be overhauled by the professional personnel
(4) 常规检查保养 Inspection and maintenance
1) 定期拆下鼓风机吸气滤清器滤芯,用洁净的压缩空气反吹清扫滤芯后安装好,防止滤芯堵
塞影响鼓风机的风量。可根据实际鼓风机运行情况清扫滤清器吸气滤芯。
Regularly remove the filter element of blower suction filter,after cleaning the filter element with clean
compressed air ,and then install it to prevent the blockage of filter element from affecting the air flow of the
blower.The suction filter element can be cleaned according to the actual operation of the blower.
2)每班检查除水过滤器上的自动排水阀,确保排水通畅,防止液态水、油进入干燥机。
Every shift check the automatic drain valve of water removal filter,to ensure the water is drained
smoothly,prevent liquid water,oil entering into the dryer.
6
3) 定期检查换塔、再生和升压的动作是否正常。
Regularly check the towers switching ,regeneration ,pressure rising, and make sure the work normally.
4) 定期检查运转条件、进口压力、进口温度和空气流量。
Regularly check operating conditions ,inlet pressure ,inlet temperature ,and air flow.
5) 定期检查控制气路过滤减压阀及过滤器,根据需要更换。
Regularly check the pressure reducing valve and filter,to replace it if necessary
6) 定期检查除水和除尘过滤器,检查堵塞情况及可能的损坏,根据需要更换滤芯。
Regularly check the pre and after filter ,check blockage and possible damage,to replace it if necessary.
7) 检查气动阀门是否泄漏或密封件是否磨损。
Check whether the pneumatic valve is leakage or not,and check whether the sealing parts is worn or not.
8) 必要时校正露点探头。(若配有露点仪)
Calibrate dew point meter detector if necessary (if have dew point meter)
1.指压缩空气进吸干机流量大于吸干机标准
处理量
Refers to that the inlet air flow rate of
1. 检查压缩机出口排气量
adsorption air dryer is bigger than the standard
Check the outlet air delivery of the
flow rate. compressor
1.进气流量过高 2.指进吸干机的压缩空气的压力 2. 控制压力
High inlet air flow rate Control the pressure
Refers to that the pressure of the compressed
2.进气压力低 3. 检查后部冷却器
air into the adsorption air dryer Check the after cooler
Low inlet air pressure 4. 检查后冷却器和前置过滤器排水阀
3.指进吸干机的压缩空气的温度
3.进气温度过高 Check the drain valve of the after-cooler and
Over high inlet air temperature Refers to the temperature of the compressed pre-filter
2.干燥空气出口 4.水份含量过大 air into the adsorption air dryer. 5. 将干燥机泄压,检查干燥剂是否变色、
露 点 过 高
Heavy moisture content 4. 指进吸干机的压缩空气的饱和含水量 中毒
Dry air outlet
dew point is 5.吸附剂被油污染 Check the adsorbent’s color to judge
Refer to the moisture content of the
over high Oil contaminated adsorbent whether it is poisoned or not
compressed air into the adsorption air dryer.
6.过滤器失效. 6. 更换过滤器芯
5. 指吸附塔内的吸附剂
Filter failure Replace the filter element.
Refers to that the adsorbent into the adsorption
7.露点指示不正确 7. 重新校验
vessels. Repeat check
Incorrect dew point instruction
8.吸附剂未干燥好 6.指吸干机前后置过滤器的工作效果 8. 调整程序时间,增加加热时间
Adsorbent is not dried well Refers to that the working effect of Adjust process time,increase the
heating time
pre-filter & after filter.
7.指安装的露点仪显示错误 jj
Refers to that the dew-point meter display an
error
8.检查加热再生程序时间
Check the heating regeneration time
1. 干燥剂扩散器滤网堵塞
The filter screen of adsorbent 1. 通过吸附筒体压力表和干燥机出口压力 1. 更换干燥剂扩散器
表检查
diffuser is clogged. Replace the desiccant diffuser
2. 压缩空气处理量超过额定 Check the pressure gauge of adsorption vessels 2. 检查进口气量的情况
3.干燥机压降太 流量或工作压力过低 and outlet pressure gauge of dryer Check the situation of the inlet air
大 2. 采用流量计检测 capacity.
Compressed air capacity is
Pressure drop of Check the air capacity by the flow-meter 3. 检查导向气路或电磁阀,根据需要更换
dryer is too high larger than rated capacity
3. 通过手动的方法检查控制气动阀是否正 Check the air line or magnetic valve ,to
3. 再生气动阀保持打开,无 常工作
法关闭 replace if necessary.
Check the pneumatic valve is working
Regenerative pneumatic valve normally by manual method
keep open but can't close.
1.蓄压过程中再生排气阀
1. 检查导向气路或电磁阀,根据需要更换
不能关闭 1. 通过手动的方法检查排气阀进气阀是否 Check the air line or magnetic valve ,to
4. 干燥塔压力 Regenerative exhaust 正常工作
replace if necessary.
无法上升 valve can't closed during the Check whether the exhaust valve working
2. 检查进气口气量的情况
The pressure of normally by manual method Check the situation of the inlet air
pressure accumulation process
drying vessels capacity.
2. 采用流量计检测
can't raise 2.出口使用流量超过干燥
Check the air capacity by the flow-meter 3. 打开再生节流阀,根据需要调解开启度
机最大处理量 3. 检查再生节流阀 Open the throttle valve, adjust the opening degree
Outlet using flow is larger than Check the regenerative throttle valve asrequired
1. 控制器失效造成转换时
间失控,空气在塔内因压力 1. 用万用表测量控制器的控制输出是否正
不稳定产生吸附剂撞击摩 常 1. 检查、维修、更换控制器
擦 Check the controlling output of controller
5 5.出口空气粉尘 Check ,repair,replace the controller
The controller failure leads to is normal or not by a multimeter
太多 Too much
uncontrolled conversion time, 2. 调整参数加长加压时间
dust of outlet air
the adsorbent occur impact 2. 查阅控制器设置参数设置是否合理 Adjust the parameter, extending the
friction due to unstable Check the setting of controller parameter pressurization time
pressure settings is reasonable or not
2. 加压时间太短
Pressurization time is too short
1. 无电磁阀信号输出 1. 检查线路板。
No magnetic valve signal Check the circuit board 1.必要时更换
output 2. 检查引线接口。 Replace if necessary
2. 引线接口不良 Check the lead wire connection port 2.必要时更换电线或紧固松动的接头
5. 蝶阀不动作 Poor Lead wires connection 3. 检查电磁阀
Butterfly valve port Replace the wires or tighten the loose
Check the magnetic valve
Can't work 3. 电磁先导阀堵塞或线圈断 connection port if necessary
线、烧毁。 3.清洗;重新接好或更换
Magnetic pilot valve is clogged Cleaning, re-connect or replace
or the coil is broken、burned
9
2) 吸干机画面 Adsorption air dryer screen
3)曲线 Curve
(1)曲线 1 Curve 1
10
(2)曲线 2 Curve 2
11
5)周期设置画面 Period setting
12
7)参数设置 2 Parameter setting 2
注:周期设置,参数设置,系统参数需管理员输入账号密码进入。
Note: Administrator needs to login with you username and password to set the cycle period and parameters
用户名:111 密码 111
Username: 111 Password:111
13
6、售后服务 After sales service
质量承诺:Quality commitment
本公司产品作为压缩空气净化设备,自购买之日或设备铭牌标注制造日期起,整机保修壹年(除
购销合同中另有约定)。
As the device of compressed air dryer, the warranty of this product lasts for one year from the
purchasing day or the manufacturing date labeled on the nameplate. (Except the contract has additional
information)
下列情况不属于保修范围:
The following cases are beyond the guarantee range.
1.用户因搬运、安装、使用、维护、保管不当而损坏的;
The fault caused by the inappropriate ways of moving, installation, use,maintenance and storage.
2.自行或非厂方维修人员拆卸产品引起的故障;
The fault caused by the disassembly of personal staff or other maintenance personnel
3.因异常电压、火灾及不可抗力等外部原因而损坏的;
The fault caused by the force majeure or other irresistible elements.
4.未按本安装使用说明书等注意事项要求使用而引起的故障。
The fault caused by the neglect of the installation operation manual or other notice.
★ 售后服务电话:0571-88684007
★ The telephone number of after sales service :0086 -571-88684007
14