17-P-30A/B/C

BASE SIZE:
Size of foundation block in X direction, Lx = 1.000 m
Size of foundation in Y direction, Ly = 2.500 m
Thickness of foundation = 2.4 m
Grout thickness = 0 m
Shaft C.G. from grout top in z dir. = 0.465 m
C.G. of skid from grout top in z dir = 0.465 m
Operating Frequency of machine = 3000 r.p.m.
wm = 314.159 Rad/Sec
1.0 MACHINE LOAD DATA:
Weight, Wi Mass, mi CG of Element
Machine Fdn Parts Description of Load
(Tons) (t-sec /m)
2
xi (m) yi (m) zi (m)
A Pump 0.167 0.02 0.500 0.475 2.865
B Motor 0.800 0.08 0.500 1.391 2.865

C Base Plate 0.336 0.03 0.500 1.250 2.865

D Others 0.040 0.00 0.500 1.250 2.865


0.00
0.00
å 1.343 0.137

3.0 FOUNDATION LOAD DATA


Description of Dimension of Elements Weight, Wi Mass, mi CG of Element
Load lxi (m) lyi (m) lzi (m) (Tons) (t-sec /m)
2
xi (m) yi (m) zi (m)
M 1.00 2.50 2.400 15.00 1.53 0.500 1.250 1.200
0.00
0.00
å 15.000 1.529

Ratio of weights of Foundation to Total machine weight = 11.17

Since Total weight of Foundation is more than 3 times weight of Machine,


Priliminary size of foundation is "OK"

Total weight of machine part & foundation å(wi) = 16.343 Tons


Total mass of machine part, foundation å (mi) = 1.666 ( t.sec2/m)

4.0 CALCULATION OF MASS MOMENT OF INERTIA:


Static Moment of Mass MI about X, Y & Z axes passing thro CG
Description of
Machine & (mi/ 12) *
Foundation Parts mi.xi mi.yi mi.zi (mi/12) * (lyi2+lzi2) (mi/12) * (lxi2+lyi2)
(lxi2+lzi2)
A 0.00851 0.00809 0.04877 0 0 0
B 0.04077 0.11344 0.23364 0 0 0
C 0.01713 0.0051 0.09813 0 0 0
0 0 0 0 0 0 0
M 0.76453 1.91131 1.83486 0.86136595 1.5303261978 0.9238022426096
0 0 0 0 0 0 0
å 0.83 2.04 2.22 0.86 1.5303261978 0.9238022426096

5.0 CALCULATION OF CENTRE OF GRAVITY OF WHOLE SYSTEM:


(includes Machine parts, foundation block)
CG about X-axis Xcg = å mi.xi / å mi = 0.50 m
CG about Y-axis Ycg = å mi.yi / å mi = 1.22 m
CG about Z-axis Zcg = å mi.zi / å mi = 1.33 m
CG of base area in X-direction = 0.50 m
CG of base area in Y-direction = 1.25 m

Calculation of Eccentricity of Whole System:


Percentage of eccentricity in X direction, ex = 0.12 %
Percentage of eccentricity in Y direction, ey = 1.07 %

Since eccentricities are less than 5%, it is safe.

Foundation stability
Vertical Force on Foundation base Pv = 163.43 kN
Area of foundation = 2.50 m2
Pressure on soil due to foundation & machine = 65.37 kN/m2

Moment @ C.G. Due to Eccentricities about X axis


Moment due to Component marked "A" My1 = 0.00 Tons.meter
Moment due to Component marked "B" My2 = 0.00 Tons.meter

Total Moment about C.G. of foundation My = 0.00 Tons.meter

Moment @ C.G. Due to Eccentricities about Y axis


Moment due to Component marked "A" Mx1 = -0.13 Tons.meter
Moment due to Component marked "B" Mx2 = 0.11 Tons.meter

Total Moment about C.G. of foundation Mx = -0.02 Tons.meter

NET Soil Bearing capacity in compression = 100 kN/m2 …..As per Soil Report.
Assumed

Soil Bearing capacity used for high speed machine foundation


= 75 kN/m2 ….75 % of actual capacity.
Consider
Result of pure static coindition check
Compression OK condition - 0
Y

ement (from Foundation Bottom Corner)


zi (m)
2.865
2.865

2.865

2.865

ement
zi (m)
1.200