You are on page 1of 43

SERVICE MANUAL

CODE: 00ZMXLC13/S4E

DIGITAL FULL COLOR


MULTIFUNCTIONAL SYSTEM
OPTION
LARGE CAPACITY TRAYS

MODEL MX-LC13
CONTENTS

[1] PRODUCT OUTLINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1


[2] SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
[3] EXTERNAL VIEW AND INTERNAL STRUCTURE
1. Sensor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
2. Switch, Heater. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
3. Drive motor, Clutch, Solenoid, Fan, PWB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
4. Roller. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
[4] OPERATIONAL DESCRIPTIONS
1. Electrical and mechanism relation diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
[5] MAINTENANCE
1. Paper feed section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
2. Transport section. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
3. Drive section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
[6] DISASSEMBLY AND ASSEMBLY
1. Each unit disassembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
2. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
[7] ADJUSTMENT
1. Paper feed section adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1
[8] ELECTRICAL SECTION
1. Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1
2. Actual wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3

Parts marked with " " are important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.

This document has been published to be used


SHARP CORPORATION for after sales service only.
The contents are subject to change without notice.
[1] PRODUCT OUTLINE
This unit is used by installing to the following machine.
This unit has the capacity of 2,500 sheets for the upper stage and 2,500 sheets for the lower stage, greatly reducing paper supply care when
installed once.

Installable machine MX-6240N/7040N

When using this unit, check to confirm that there is any other indispensable option by referring to the configuration in the Service manual of the
machine.

MX-LC13 PRODUCT OUTLINE 1 - 1


[2] SPECIFICATIONS
Model name MX-LC13
Name LARGE CAPACITY TRAYS
Transport reference Center reference
Paper size Refer to the table of “Paper size/Kind/Weight”.
Paper size display YES
Paper size setting Upper tray: User setting
Lower tray: User setting
Paper size setting when shipping Inch: 11 x 17
AB: A3
Feedable paper weight Refer to the table of “Paper size/Kind/Weight”.
Paper type Refer to the table of “Paper size/Kind/Weight”.
Paper capacity Normal paper Upper tray: 2,500 sheets
Lower tray: 2,500 sheets (80g/m2 )
Paper remaining detection Level detection: 6 steps
Upper/lower: 100%, 83.3%, 66.7%, 50%, 33.3%, 16.7%, and none
Paper feed system Air paper feed, assist (with the dehumidifier heater)
Paper supply system Front loading system
Tray lift time Up Upper/lower tray: Within 24 sec
Time required to detect paper empty from insertion of the tray.
Down Upper/lower tray: Within 24 sec
Time required to detect paper empty from insertion of the tray.
Tray lock YES
Power consumption Max 900W
Power source AC120V/10A cord (North America)
AC230V/10A cord series (Europe) (3 pcs. Bundled for Europe/U.K./ Australia)
External dimensions (W x D x H ) 880 x 760 x 986mm
Weight 130.3kg
Dehumidifier heater AC10W x 5 50W (Service part )

Paper size/Kind/Weight
1-stage 2-stage
Min. weight 55g/m2 55g/m2
Max. weight 300g/m2 300g/m2
Paper type Thin paper Yes Yes
Standard paper Yes Yes
Recycled paper Yes Yes
Color paper Yes Yes
Letterhead Yes Yes
Printed paper Yes Yes
Punched paper Yes Yes
Thick paper 1 106 - 176g/m 2 Yes Yes
Thick paper 2 177 - 220g/m 2 Yes Yes
Thick paper 3 221 - 256g/m 2 Yes Yes
Thick paper 4 257 - 300g/m 2 Yes Yes
Embossed paper Yes Yes
Tab paper Yes Yes
OHP Yes Yes
Label sheet Yes Yes
Glossy paper Yes Yes
User type 1 - 9 Yes Yes
Paper size 12' x 18' (A3W ) 305 x 457 Yes Yes
Ledger (11' x 17' ) 279 x 432 Yes Yes
Ledger (11' x 17' ) Z-fold 279 x 216 No No
Legal (8.5' x 14' ) 216 x 356 Yes Yes
Legal (8.5' x 14' ) Z-fold 216 x 178 No No
Asian legal (8.5 x 13.5 ) 216 x 343 Yes Yes
Mexico legal (8.5' x 13.4' ) 216 x 340 Yes Yes
Foolscap (8.5' x 13' ) 216 x 330 Yes Yes
Letter (8.5' x 11' ) 279 x 216 Yes Yes
Letter R (8.5' x 11'R ) 216 x 279 Yes Yes
Letter R (8.5' x 11'R ) Z-fold 216 x 140 No No
Letter R (8.5' x 11'R ) 2-fold 216 x 140 No No
Letter R 3-fold/4-fold 216 x 93/70 No No
Invoice (5.5' x 8.5' ) *1 216 x 140 No No
Invoice R (5.5' x 8.5'R ) 140 x 216 No No
Executive R (7.25' x 10.5'R ) 184 x 266 Yes Yes
9 x 12 (A4W ) 305 x 229 Yes Yes
A3 297 x 420 Yes Yes
A3 Z-fold 297 x 210 No No
B4 257 x 364 Yes Yes

MX-LC13 SPECIFICATIONS 2 - 1
1-stage 2-stage
Paper size B4 Z-fold 257 x 182 No No
A4 297 x 210 Yes Yes
A4-R 210 x 297 Yes Yes
A4-R Z-fold 210 x 148 No No
A4R 2-fold, Z-fold 210 x 148 No No
A4-R 3-fold/4-fold 210 x 99/74 No No
B5 257 x 182 Yes Yes
B5-R 182 x 257 Yes Yes
A5 *1 210 x 148 No No
A5-R 148 x 210 No No
SRA3 320 x 450mm Yes Yes
SRA4 320 x 225mm Yes Yes
Kiku 8 318 x 234.75 Yes Yes
A8 312.5 x 220 Yes Yes
Kiku 4 318 x 469.5 Yes Yes
A4 312.5 x 440 Yes Yes
8K 270 x 390 Yes Yes
16K 270 x 195 Yes Yes
16K-R 195 x 270 Yes Yes
Monarch 98 x 191 No No
COM10 105 x 241 No No
DL 110 x 220 No No
C5 229 x 162 No No
Long No. 3 120 x 235 No No
Long No. 4 90 x 205 No No
Western No. 2 114 x 162 No No
Western No. 4 105 x 235 No No
Square No. 2 240 x 332 No No
Square No. 3 216 x 277 No No
Special - custom size Yes Yes
Custom range min X (Sub scanning) 182 182
max X (Sub scanning ) 457 457
min Y (Main scanning ) 182 182
max Y (Main scanning ) 320 320
Special - size undefined No No
Long scale paper Width: 90 - 305 No No
Length: 458 - 1200

*1 : Invoice and A5 are treated as special paper.

MX-LC13 SPECIFICATIONS 2 - 2
TopPage
1 : ‘13/Dec

[3] EXTERNAL VIEW AND INTERNAL STRUCTURE


1. Sensor

L1DFB01
L1DF101 L1DT103
L1 DA102
L1DT106
L1 DA101
L1DT110 1 1
L1DF001 L1DT115
L1DD005
L1DT105

L1DT104
L1DF002
L1DT114
L1DT112 L1DT113

L1DF003 L1 DA001/ L1DT107 L1DT111


L1DF005
L1DF010 L1 DA002
L1DF004

L1DD003 L1DF201 L1DT203


L1DD001 L1DD004
L1 DA202
L1DT206
L1 DA201
L1DT210 1 1
L1DT215

L1DT205

L1DT204

L1DT214
L1DT212 L1DT213

L1DT207 L1DT211

Signal name Name Function/Operation


L1DA001/L1DA002 LCT inside temperature/humidity sensor Detects the temperature and humidity in the LCT.
L1DA101 1CS hot-air heater temperature sensor Detects the temperature in the hot-air heater.
L1DA102 1CS temperature sensor Detects the temperature in the 1CS paper feed duct.
L1DA201 2CS hot-air heater temperature sensor Detects the temperature in the hot-air heater.
L1DA202 2CS temperature sensor Detects the temperature in the 2CS paper feed duct.
L1DD001 LCT machine connection sensor Detects connection to the machine.
L1DD003 Transport open/close sensor 1 Detects open/close of the transport paper guide.
L1DD004 Transport open/close sensor 2 Detects open/close of the transport paper guide.
L1DD005 Vertical transport open/close sensor Detects open/close of the vertical transport paper guide.
L1DF001 Vertical transport sensor 1 Detects transport of paper.
L1DF002 Vertical transport sensor 2 Detects transport of paper.
L1DF003 Vertical transport sensor 3 Detects transport of paper.
L1DF004 Vertical transport sensor 4 Detects transport of paper.
L1DF005 LCT paper exit sensor Detects transport of paper.
L1DF010 Horizontal transport sensor 5 Detects transport of paper.
L1DF101 1CS paper exit sensor Detects transport of paper.
L1DF201 2CS paper exit sensor Detects transport of paper.
L1DFB01 Manual feed paper entry sensor Detects transport of paper.
L1DT103 1CS paper sensor Detects 1CS paper.
L1DT104 1CS lift motor encoder sensor Detects rotation of the 1CS lift motor.
L1DT105 1CS tray lock sensor Detects lock of the 1CS tray.
L1DT106 1CS upper limit sensor Detects the upper limit of the 1CS tray.
L1DT107 1CS lower limit sensor Detects the lower limit of the 1CS tray.
L1DT110 1CS paper top surface sensor Detects the top surface of paper in the 1CS.
L1DT111 1CS length sensor Detects the 1CS length.
L1DT112 1CS width sensor 1 Detects the 1CS width.
L1DT113 1CS width sensor 2 Detects the 1CS width.
L1DT114 1CS width sensor 3 Detects the 1CS width.
1 L1DT115 1CS paper rear edge sensor Detects paper rear edge of 1CS.
L1DT203 2CS paper sensor Detects 2CS paper.
L1DT204 2CS lift motor encoder sensor Detects rotation of the 2CS lift motor.

MX-LC13 EXTERNAL VIEW AND INTERNAL STRUCTURE 3 - 1


TopPage
1 : ‘13/Dec
Signal name Name Function/Operation
L1DT205 2CS tray lock sensor Detects lock of the 2CS tray.
L1DT206 2CS upper limit sensor Detects the upper limit of the 2CS tray.
L1DT207 2CS lower limit sensor Detects the lower limit of the 2CS tray.
L1DT210 2CS paper top surface sensor Detects the top surface of paper in the 2CS.
L1DT211 2CS length sensor Detects the 2CS length.
L1DT212 2CS width sensor 1 Detects the 2CS width.
L1DT213 2CS width sensor 2 Detects the 2CS width.
L1DT214 2CS width sensor 3 Detects the 2CS width.
1 L1DT215 2CS paper rear edge sensor Detects paper rear edge of 1CS.

2. Switch, Heater

L1HT101

L1DT102
L1DT101
L1DT116
L1DT108
L1WH1

.1WHSW

L1HT201
L1DT109

L1DT202
L1DD002 L1DT201
L1DT216
L1DT208
L1WH2

L1DT209
L1WH3

L1WH4

L1WH5

Signal name Name Function/Operation


L1DD002 LCT front door open/close detection switch Detects open/close of the front door.
L1DT101 1CS insertion detection switch 1 Detects insertion of the cassette.
L1DT102 1CS upper limit switch Prevents the tray from lifting extraordinarily to break the paper feed unit.
L1DT108 1CS reverse rotation detection switch Detects reverse rotation of the lift motor.
L1DT109 1CS descending switch Shifts the tray to the paper supply position.
L1DT116 1CS insertion detection switch 2 Detects insertion of the cassette.
L1DT201 2CS insertion detection switch 1 Detects insertion of the cassette.
L1DT202 2CS upper limit switch Prevents the tray from lifting extraordinarily to break the paper feed unit.
L1DT208 2CS reverse rotation detection switch Detects reverse rotation of the lift motor.
L1DT209 2CS descending switch Shifts the tray to the paper supply position.
L1DT216 2CS insertion detection switch 2 Detects insertion of the cassette.
L1HT101 1CS hot-air heater Makes paper feed air hot.
L1HT201 2CS hot-air heater Makes paper feed air hot.
L1WH1 1CS dehumidifier heater Dehumidifies inside of the LCT. (Option)
L1WH2 2CS dehumidifier heater Dehumidifies inside of the LCT. (Option)
L1WH3 Dehumidifier heater 3 Dehumidifies inside of the LCT. (Option)
L1WH4 Dehumidifier heater 4 Dehumidifies inside of the LCT. (Option)
L1WH5 Dehumidifier heater 5 Dehumidifies inside of the LCT. (Option)
L1WHSW Dehumidifier heater switch Manually turns ON/OFF the dehumidifier heater. (Option)

MX-LC13 EXTERNAL VIEW AND INTERNAL STRUCTURE 3 - 2


3. Drive motor, Clutch, Solenoid, Fan, PWB

L1MT104

L1SL101 L1CL101
L1CL102

L1SL102 L1MT104
L1MT103

L1MT101
L1MT102 L1MT001
L1MT204

L1SL201 L1CL201
L1CL202
L1MT204
L1SL202
L1MT203

L1MT201
L1MT202

3
L1MT002

1
2

Signal name Name Function/Operation


L1CL101 1CS paper feed clutch Controls ON/OFF of the 1CS paper feed belt.
L1CL102 1CS transport clutch Controls ON/OFF of the 1CS transport roller.
L1CL201 2CS paper feed clutch Controls ON/OFF of the 2CS paper feed belt.
L1CL202 2CS transport clutch Controls ON/OFF of the 2CS transport roller.
L1MT001 Transport motor 1 Drives the paper feed and the transport section.
L1MT002 Power unit cooling fan Cools the power unit.
L1MT101 1CS lift motor Lifts the paper feed base.
L1MT102 1CS suction fan Sucks the paper feed unit.
L1MT103 1CS exhaust fan Blows to the paper feed section.
L1MT104 1CS assist fan Assists the paper feed unit.
L1MT201 2CS lift motor Lifts the paper feed base.
L1MT202 2CS suction fan Blows to the paper feed unit.
L1MT203 2CS exhaust fan Blows to the paper feed section.
L1MT204 2CS assist fan Assists the paper feed unit.
L1SL101 1CS suction valve solenoid Controls ON/OFF of suction air.
L1SL102 1CS tray lock solenoid Controls ON/OFF of the tray lock.
L1SL201 2CS suction valve solenoid Controls ON/OFF of suction air.
L1SL202 2CS tray lock solenoid Controls ON/OFF of the tray lock.

No. Name Function/Operation


1 Main PWB Controls and drives the LCT.
2 DC power PWB Switch AC to DC.
3 Heater relay PWB Turns ON/OFF the AC power.
4 AC PWB Controls the AC power.

MX-LC13 EXTERNAL VIEW AND INTERNAL STRUCTURE 3 - 3


4. Roller

1
2
3
4

5
6

7
8

9
10

11
12
13
14
15
16
17
18

No. Name Function/Operation


1 Transport roller 1 (Idle) Apply a pressure to paper and the transport roller, providing a transport power to the
transport roller.
2 Transport roller 1 (Drive) Transports paper from the paper feed tray to the transport roller 4.
3 Transport roller 3 (Drive) Transports paper from the manual paper feed tray to the transport roller 4.
4 Transport roller 3 (Idle) Apply a pressure to paper and the transport roller, providing a transport power to the
transport roller.
5 Transport roller 4 (Drive) Transports paper to the transport roller 5.
6 Transport roller 4 (Idle) Apply a pressure to paper and the transport roller, providing a transport power to the
transport roller.
7 Transport roller 5 (Drive) Transports paper to the transport roller 6.
8 Transport roller 5 (Idle) Apply a pressure to paper and the transport roller, providing a transport power to the
transport roller.
9 Transport roller 6 (Drive) Transports paper to the transport roller 7.
10 Transport roller 6 (Idle) Apply a pressure to paper and the transport roller, providing a transport power to the
transport roller.
11 Transport roller 8 (Idle) Apply a pressure to paper and the transport roller, providing a transport power to the
transport roller.
12 Transport roller 8 (Drive) Transports paper to the transport unit.
13 Transport roller 7 (Idle) Apply a pressure to paper and the transport roller, providing a transport power to the
transport roller.
14 Transport roller 7 (Drive) Transports paper to the transport roller 8.
15 Transport roller 9 (Idle) Apply a pressure to paper and the transport roller, providing a transport power to the
transport roller.
16 Transport roller 9 (Drive) Transports paper to the transport roller 7.
17 Transport roller 2 (Idle) Apply a pressure to paper and the transport roller, providing a transport power to the
transport roller.
18 Transport roller 2 (Drive) Transports paper from the paper feed tray to the transport roller 7.

MX-LC13 EXTERNAL VIEW AND INTERNAL STRUCTURE 3 - 4


PHR-4 CN-G B16B-PHDSS-B
+5V 1 1 +5V
L1DA002 2 2 L1DA002
GND 3 3 GND
L1DA001 4 4 L1DA001
PS-187-2V
+24V 1
L1DT101 2
L1DT101

PS-187-2V
+24V 1
L1DT116 2
HRS HRS
L1DT116

L1DT115

DF11-6DS-2C DF11-6DS-2C
+DF11-6DP-SP1(05) +DF11-6DP-SP1(05)
1
L1 DA001/
L1 DA002

+5V GND
6 5 4 3 2 1 6 5 4 3 2 1
SMP-18V-NC SMR-18V-N
L1DT106

ELR-03V ELP-03V
L1MT101-D 1 1 1 1
L1MT101-U 3 3 2 2 CN-I B28B-PHDSS-B
3 3 3 +24V_PS2
PS-187-3V 4 4 4 L1DT108_R
+24V 1 5 5 5 L1MT101-D
L1DT108 3 6 6 6 L1DD002_R
L1DT107

7 7 7 L1DT116_R
L1DT113

8 8 10 +24V_PS2
L1DT104

PHR-3 9 9 11 L1DT101_R
+5VR 1 10 10 14 L1MT101-U
L1DT114

L1DT111

GND 2 11 11 15 +5VR
L1DT107 3 12 12 17 L1DT107
13 13 20 L1DT104
L1MT101

SMR-03V-N SMP-03V-NC 14 14 21 +24V


L1MT104

+5V 1 1 15 15 22 L1MT104_1
GND 2 2 16 16 23 P_GND
L1DT112

L1DT104 3 3 17 17 25 L1DT110
18 18 28 L1DA104

MX-LC13 OPERATIONAL DESCRIPTIONS 4 - 1


SMP-03V-NC SMR-03V-N
+24V 1 1
CN-J B22B-PHDSS-B
L1MT104_1 2 2
1 GND
P_GND 3 3
2 L1DA103
L1DT108

3 +5VR
179228-3
4 L1LD101
+5V 1
5 L1DT109
L1DT112 2
8 L1DT105
GND 3
10 +24V_F5
11 L1SL102-U
179228-3
12 L1SL102-L
+5V 1
13 +24V
L1DT113 2
14 L1MT104_2
GND 3
15 P_GND
L1DT105
17 L1DT106
179228-3
18 +5V
+5V 1

L1SL102
L1DT114 2
GND 3
Electrical and mechanism relation diagram

LCT MAIN PWB


HRS HRS
DF11-6DS-2C DF11-6DS-2C
+DF11-6DP-SP1(05) +DF11-6DP-SP1(05)
+5V GND
6 5 4 3 2 1 6 5 4 3 2 1
L1DT110

SMP-10V-NC SMR-10V-N
[4] OPERATIONAL DESCRIPTIONS

BU10P-TR-P-H 1 1
PHR-4 SMR-04V-N SMP-04V-NC PHNR-10-H PHNR-10-H 2 2
+5VR 1 1 1 1 10 3 3
L1WH1
L1LD101 2 2 2 2 9 4 4

L1DT109
L1DT109 3 3 3 3 8 5 5
GND 4 4 4 4 7 6 6
5 6 7 7
179228-3 6 5 8 8
+5V 1 7 4 9 9
L1DT110 2 8 3 10 10
GND 3 9 2
L1MT104

BU16P-TR-P-H 10 1 CN-K B36B-PNDZS-1


179228-3 PHNR-16-H PHNR-16-H 3 GND
+5V 1 1 16 7 +5V
L1DT105 2 2 15 BU12P-TR-P-H 11 L1DT112
GND 3 3 14 PHNR-12-H PHNR-12-H 12 GND
4 13 1 12 13 L1DT113
5 12 2 11 15 L1DT114
6 11 3 10 SMP-07V-NC SMR-07V-N 17 L1DT115
SMR-03V-N SMP-03V-NC 7 10 4 9 1 1 20 +5V
+24V 1 1 8 9 5 8 2 2 26 L1DT111
L1SL102-U 2 2 9 8 6 7 3 3
L1SL102-L 3 3 10 7 7 6 4 4
11 6 8 5 5 5
SMP-03V-NC SMR-03V-N 12 5 9 4 6 6
+24V 1 1 13 4 10 3 7 7
L1MT104_2 2 2 14 3 11 2
P_GND 3 3 15 2 12 1
16 1
179228-3 SMR-03V-N SMP-03V-NC SMP-06V-NC SMR-06V-N CN-A B11B-PASK-1
A. Paper feed tray (1CS)

+5V 1 1 1 1 1

RELAY PWB
+24V_F5 11
L1DT106 2 2 2 2 2
L1PW001 10
GND 3 3 3 3 3
GND 9
4 4
L1HT201 8
179228-3 5 5
GND 7
+5V 1 6 6
L1HT101 6
L1DT111 2 CN-B B14B-PHDSS-B
L1DT116_R 5
GND 3
ELR-02V ELP-02V CN-D B2P3-VH-R P GND 4 14 L1DT216_R
1 1 1 KWL_3 /HL PR1 3 13 L1DT116_R
2 2 2 N.C. L1DT216_R 2 12 GND
179228-3 3 KWN_3 /HL PR2 1 11 P_GND
+5V 1 10 /HL_PR2
1 HRS 9 /HL_PR1
L1DT115 2
2 DF11-4DS-2C
: ‘13/Dec

8 L1PW001

+5V
GND 3
3 +DF11-4DP-SP1(05) 7 +24V_F5
4 6 L1HT201

1
5 L1HT101
1 HRS
2 DF11-4DS-2C

+5V
3 +DF11-4DP-SP1(05)
4
TopPage

1 HRS
DF11-4DS-2C

GND
2

1
3 +DF11-4DP-SP1(05)
4
1

1.
TopPage
1 : ‘13/Dec

Signal name Name Function/Operation


L1DA001/L1DA002 LCT inside temperature/humidity sensor Detects the temperature and humidity in the LCT.
L1DT101 1CS insertion detection switch 1 Detects insertion of the cassette.
L1DT104 1CS lift motor encoder sensor Detects rotation of the 1CS lift motor.
L1DT105 1CS tray lock sensor Detects lock of the 1CS tray.
L1DT106 1CS upper limit sensor Detects the upper limit of the 1CS tray.
L1DT107 1CS lower limit sensor Detects the lower limit of the 1CS tray.
L1DT108 1CS reverse rotation detection switch Detects reverse rotation of the lift motor.
L1DT109 1CS descending switch Shifts the tray to the paper supply position.
L1DT110 1CS paper top surface sensor Detects the top surface of paper in the 1CS.
L1DT111 1CS length sensor Detects the 1CS length.
L1DT112 1CS width sensor 1 Detects the 1CS width.
L1DT113 1CS width sensor 2 Detects the 1CS width.
L1DT114 1CS width sensor 3 Detects the 1CS width.
1 L1DT115 1CS paper rear edge sensor Detects paper rear edge of 1CS.
L1DT116 1CS insertion detection switch 2 Detects insertion of the cassette.
L1MT101 1CS lift motor Lifts the paper feed base.
L1MT104 1CS assist fan Assists the paper feed unit.
L1SL102 1CS tray lock solenoid Controls ON/OFF of the tray lock.
L1WH1 1CS dehumidifier heater Dehumidifies inside of the LCT. (Option)

MX-LC13 OPERATIONAL DESCRIPTIONS 4 - 2


PS-187-2V
+24V 1
L1DT201 2
L1DT201

PS-187-2V
+24V 1
L1DT215

L1DT216 2
HRS HRS
L1DT216

DF11-6DS-2C DF11-6DS-2C
+DF11-6DP-SP1(05) +DF11-6DP-SP1(05)
1

+5V GND
6 5 4 3 2 1 6 5 4 3 2 1
L1DT206

ELR-03V ELP-03V SMP-18V-NC SMR-18V-N


L1MT201-D 1 1 1 1
L1MT201-U 3 3 2 2 CN-Q B28B-PHDSS-B
3 3 3 +24V_PS1
PS-187-3V 4 4 4 L1DT208_R
+24V 1 5 5 5 L1MT201-D
L1DT208 3 6 6 6 L1DD002_R
L1DT207

7 7 7 L1DT216_R
L1WH5
L1DT213

8 8 10 +24V_PS1
L1DT204

PHR-3 9 9 11 L1DT201_R
+5VR 1 10 10 14 L1MT201-U
L1DT214

GND 2 11 11 15 +5VR
L1DT211

L1DT207 3 12 12 17 L1DT207
13 13 20 L1DT204
L1MT201

SMR-03V-N SMP-03V-NC 14 14 21 +24V


L1MT204

+5V 1 1 15 15 22 L1MT204_1
GND 2 2 16 16 23 P_GND
L1DT212

L1DT204 3 3 17 17 25 L1DT210
18 18 28 L1DA204
SMP-03V-NC SMR-03V-N
+24V 1 1
CN-P B22B-PHDSS-B
L1MT204_1 2 2
1 GND
P_GND 3 3
2 L1DA203
L1DT208

3 +5VR
179228-3

MX-LC13 OPERATIONAL DESCRIPTIONS 4 - 3


4 L1LD201
+5V 1
5 L1DT209
L1DT212 2
8 L1DT205
GND 3
10 +24V_F5
11 L1SL202-U
179228-3
12 L1SL202-L
+5V 1
13 +24V

L1WH4
L1DT213 2
14 L1MT204_2
GND 3
15 P_GND
L1DT205

17 L1DT206
179228-3
18 +5V
+5V 1
L1SL202 L1DT214 2
GND 3

LCT MAIN PWB


HRS HRS
DF11-6DS-2C DF11-6DS-2C
+DF11-6DP-SP1(05) +DF11-6DP-SP1(05)

L1WH3
+5V GND
6 5 4 3 2 1 6 5 4 3 2 1
L1DT210

SMP-10V-NC SMR-10V-N
BU10P-TR-P-H 1 1
PHR-4 PHNR-10-H PHNR-10-H 2 2
+5VR 1 1 1 1 10 3 3
L1WH2

LTLD201 2 2 2 2 9 4 4

L1DT209
L1DT209 3 3 3 3 8 5 5
GND 4 4 4 4 7 6 6
SMR-04V-N SMP-04V-NC 5 6 7 7
179228-3 6 5 8 8
+5V 1 7 4 9 9
L1DT210 2 8 3 10 10
3 9 2
L1MT204

GND3
BU16P-TR-P-H 10 1 CN-O B36B-PNDZS-1
179228-3 PHNR-16-H PHNR-16-H 3 GND
+5V 1 1 16 7 +5V
L1DT205 2 2 15 BU12P-TR-P-H 11 L1DT212
GND 3 3 14 PHNR-12-H PHNR-12-H 12 GND
4 13 1 12 13 L1DT213
5 12 2 11 15 L1DT214
6 11 3 10 SMP-07V-NC SMR-07V-N 17 L1DT215
SMR-03V-N SMP-03V-NC 7 10 4 9 1 1 20 +5V
+24V 1 1 8 9 5 8 2 2 26 L1DT211
L1SL202-U 2 2 9 8 6 7 3 3
L1SL202-L 3 3 10 7 7 6 4 4
11 6 8 5 5 5
SMP-03V-NC SMR-03V-N 12 5 9 4 6 6
+24V 1 1 13 4 10 3 7 7
L1MT204_2 2 2 14 3 11 2
P_GND 3 3 15 2 12 1
16 1
179228-3 SMR-03V-N SMP-03V-NC SMP-06V-NC ELR-02V ELP-02V
CN-A B11B-PASK-1
B. Paper feed tray (2CS)

+5V 1 1 1 1 1 1 1

RELAY PWB
2 2 +24V_F5 11
L1DT206 2 2 2 2 2
L1PW001 10
GND 3 3 3 3 3 ELR-02V ELP-02V GND 9
4 4 1 1
CN-E B4P(5-3)-VH L1HT201 8
179228-3 5 5 2 2
1 KWL_1 GND 7
+5V 1 6 6
ELR-02V ELP-02V 2 KWL_2 L1HT101 6
L1DT211 2 SMR-06V-N CN-B B14B-PHDSS-B
1 1 3 N.C. L1DT116_R 5
GND 3
ELR-02V 2 2 4 KWN_1 P GND 4 14 L1DT216_R
5 KWN_2 /HL PR1 3 13 L1DT116_R
ELR-02V ELP-02V L1DT216_R 2 12 GND
1 1 /HL PR2 1 11 P_GND
2 2 10 /HL_PR2
: ‘13/Dec

179228-3 1 HRS 9 /HL_PR1


+5V 1 2 DF11-4DS-2C 8 L1PW001

+5V
L1DT215 2 3 +DF11-4DP-SP1(05) 7 +24V_F5
GND 3 4 6 L1HT201
5 L1HT101
1 HRS

1
2 DF11-4DS-2C

+5V
3 +DF11-4DP-SP1(05)
TopPage

4
1 HRS
DF11-4DS-2C

GND
2
1

1
3 +DF11-4DP-SP1(05)
4
TopPage
1 : ‘13/Dec

Signal name Name Function/Operation


L1DT201 2CS insertion detection switch 1 Detects insertion of the cassette.
L1DT204 2CS lift motor encoder sensor Detects rotation of the 2CS lift motor.
L1DT205 2CS tray lock sensor Detects lock of the 2CS tray.
L1DT206 2CS upper limit sensor Detects the upper limit of the 2CS tray.
L1DT207 2CS lower limit sensor Detects the lower limit of the 2CS tray.
L1DT208 2CS reverse rotation detection switch Detects reverse rotation of the lift motor.
L1DT209 2CS descending switch Shifts the tray to the paper supply position.
L1DT210 2CS paper top surface sensor Detects the top surface of paper in the 2CS.
L1DT211 2CS length sensor Detects the 2CS length.
L1DT212 2CS width sensor 1 Detects the 2CS width.
L1DT213 2CS width sensor 2 Detects the 2CS width.
L1DT214 2CS width sensor 3 Detects the 2CS width.
1 L1DT215 2CS paper rear edge sensor Detects paper rear edge of 2CS.
L1DT216 2CS insertion detection switch 2 Detects insertion of the cassette.
L1MT201 2CS lift motor Lifts the paper feed base.
L1MT204 2CS assist fan Assists the paper feed unit.
L1SL202 2CS tray lock solenoid Controls ON/OFF of the tray lock.
L1WH2 2CS dehumidifier heater Dehumidifies inside of the LCT. (Option)
L1WH3 Dehumidifier heater 3 Dehumidifies inside of the LCT. (Option)
L1WH4 Dehumidifier heater 4 Dehumidifies inside of the LCT. (Option)
L1WH5 Dehumidifier heater 5 Dehumidifies inside of the LCT. (Option)

MX-LC13 OPERATIONAL DESCRIPTIONS 4 - 4


PAP-07V-S CN-T B18B-PHDSS-B
+24V 1 14 +24V
P_GND 2 15 P_GND
N.C. 3 16 L1MT001-CLK
L1MT001-CLK 4 17 L1MT001
L1MT001 5 18 L1MT001-T
N.C. 6
L1MT001-T 7
PS-187
+24V
L1MT001

SMP-08V-NC SMR-08V-N
L1CL201
L1CL101

L1DT102_R 1 1
2 2
179228-3 3 3
+5V 1 4 4
L1DT103 2 5 5
GND 3 6 6
7 7
SMR-03V-N SMP-03V-NC 8 8
+24V 1 1
L1SL101 3 3
SMR-02V-NSMP-02N-NC SMP-06V-NCSMR-06V-N
L1DA102 1 1 1 1
GND 2 2 2 2
3 3
SMR-04V-N SMP-04V-NC 4 4
1 1 5 5
2 2 6 6
L1MT202

3 3
4 4
L1MT102

ELP-03V ELR-03V ELR-03V ELP-03V


L1MT103

1 1 1 1 HRL1

MX-LC13 OPERATIONAL DESCRIPTIONS 4 - 5


2 2 2 2
CN-H B40B-PNDZS-1
3 3 3 3 HRN1 1 L1DT101_R
2 L1DT102_R
BU02P-TR-P-H 3 P_GND
PHNR-02-H PHNR-02-H 4 P_GND
+2 4 V 2 1 7 L1DD002_R_F1
L1CL101 1 2 8 L1CL101
9 L1DD002_R_F1
10 L1SL101
13 +5V
14 GND
15 L1DT103
SMR-04V-N SMP-04V-NC 16 GND

L1SL201
L1MT102-24V 1 1 18 L1MT102-24V
L1SL101

L1MT102 2 2 19 L1MT102
P_GND 3 3 20 L1MT102-T
L1MT203 L1MT102-T 44 21
22
L1MT103-24V
L1MT103
SMR-04V-N SMP-04V-NC 23 L1MT103-T
L1MT103-24V 1 1 31 L1DO101
L1MT103 2 2 36 L1DA101
P_GND 3 3 37 GND
L1MT103-T 4 4 38 L1DA102
39 GND
PS-187
+24V
L1DT102

SMP-08V-NC SMR-08V-N
2

2
L1DT202_R 1 1
2 2
179228-3 3 3

LCT MAIN PWB


+5V 1 4 4
L1DT203 2 5 5

L1DT202
L1DT103
GND 3 6 6

L1HT201
7 7
L1HT101

L1DT203
SMR-03V-N SMP-03V-NC 8 8
+24V 1 1
L1SL201 3 3
SMR-02V-N SMP-02V-NC SMP-06V-NC SMR-06V-N
L1DA202 1 1 1 1
GND 2 2 2 2

L1DA101

L1DA201
3 3
SMR-04V-N SMP-04V-NC 4 4
1 1 5 5

1
1
2 2 6 6
3 3
4 4
ELP-03V ELR-03V ELR-03V ELP-03V
1 1 1 1 HRL2
2 2 2 2
CN-R B40B-PNDZS-1
3 3 3 3 HRN2 1 L1DT201_R
2 L1DT202_R
BU02P-TR-P-H 3 P_GND
PHNR-02-H PHNR-02-H 4 P_GND

3
+2 4 V 2 1 7 L1DD002_R_F1

L1DA102

L1DA202
L1CL201 1 2 8 L1CL201
9 L1DD002_R_F1
10 L1SL201
13 +5V
C. Paper feed unit

14 GND
15 L1DT203
SMR-04V-N SMP-04V-NC 16 GND
L1MT202-24V 1 1 18 L1MT202-24V
L1MT202 2 2 19 L1MT202
P_GND 3 3 20 L1MT202-T
L1MT202-T 4 4 21 L1MT203-24V
22 L1MT203
SMR-04V-N SMP-04V-NC 23 L1MT203-T
L1MT203-24V 1 1 31 L1DO201
L1MT203 2 2 36 L1DA201
P_GND 3 3 37 GND
L1MT203-T 4 4 38 L1DA202
39 GND
40 GND
Signal name Name Function/Operation
L1CL101 1CS paper feed clutch Controls ON/OFF of the 1CS paper feed belt.
L1CL201 2CS paper feed clutch Controls ON/OFF of the 2CS paper feed belt.
L1DA101 1CS hot-air heater temperature sensor Detects the temperature in the hot-air heater.
L1DA102 1CS temperature sensor Detects the temperature in the 1CS paper feed duct.
L1DA201 2CS hot-air heater temperature sensor Detects the temperature in the hot-air heater.
L1DA202 2CS temperature sensor Detects the temperature in the 2CS paper feed duct.
L1DT102 1CS upper limit switch Prevents the tray from lifting extraordinarily to break the paper feed unit.
L1DT103 1CS paper sensor Detects 1CS paper.
L1DT202 2CS upper limit switch Prevents the tray from lifting extraordinarily to break the paper feed unit.
L1DT203 2CS paper sensor Detects 2CS paper.
L1HT101 1CS hot-air heater Makes paper feed air hot.
L1HT201 2CS hot-air heater Makes paper feed air hot.
L1MT001 Transport motor 1 Drives the paper feed and the transport section.
L1MT102 1CS suction fan Sucks the paper feed unit.
L1MT103 1CS exhaust fan Blows to the paper feed section.
L1MT202 2CS suction fan Blows to the paper feed unit.
L1MT203 2CS exhaust fan Blows to the paper feed section.
L1SL101 1CS suction valve solenoid Controls ON/OFF of suction air.
L1SL201 2CS suction valve solenoid Controls ON/OFF of suction air.

No. Name Function/Operation


1 Paper feed belt Sucks paper to the belt to transport it.
2 Suction valve Opens and closes the valve to apply a sucking power to the paper feed belt.
3 Relief valve Opens and closes the valve by a change in the wind pressure in the duct when in paper
feed operation.

MX-LC13 OPERATIONAL DESCRIPTIONS 4 - 6


XADR-40V XADRP-40V
1 1
2 2
3 3
4 4
5 5
6 6
CN-S B32B-PHDSS-B 7 7 SMP-03V-NC SMR-03V-N 179228-3
GND 2 8 8 1 1 1 +5V
+5V 3 9 9 2 2 2 L1DFB01
+5V 4 10 10 3 3 3 GND
L1DD005 5 11 11
L1DFB01 6 12 12 SMP-04V-NC SMR-04V-N 179228-3
+5V 7 13 13 1 1 1 +5V
L1DF101 8 14 14 2 2 2 L1DF101
GND 9 15 15 3 3 3 GND
+5V 10 16 16 4 4
L1DF201 11 17 17
GND 12 18 18 SMP-06V-NC SMR-06V-N 179228-3
+5V 13 19 19 1 1 1 +5V
L1DF001 14 20 20 2 2 2 L1DF001
GND 15 21 21 SMP-06V-NC SMR-06V-N 179228-3 3 3 3 GND
+5V 16 22 22 1 1 1 +5V 4 4
L1DF002 17 23 23 2 2 2 L1DF002 5 5 179228-3
GND 18 24 24 3 3 3 GND 6 6 1 +5V
D. Vertical transport unit

+5V 19 25 25 4 4 2 L1DD005
L1DF003 20 26 26 5 5 179228-3 3 GND
GND 21 27 27 6 6 1 +5V
+5V 22 28 28 2 L1DD003
L1DF004 23 29 29 3 GND
GND 24 30 30
+5V 25 31 31
L1DF005 26 32 32

L1DD003
GND 27 33 33
+5V 28 34 34

12
L1DF010 29 35 35
GND 30 36 36
37 37
38 38

L1DD005

11
39 39
40 40

L1DF005

13 14
6

10

17
9

16
L1DF004
L1DFB01

L1DF201

18
L1DF003
8

SMP-03V-NC SMR-03V-N 179228-3


1 1 1 +5V
2 2 2 L1DF003
4 3

7
5

3 3 3 GND
L1DF001

L1DF002

L1DF010
SMP-03V-NC SMR-03V-N 179228-3
L1DF101

1 1 1 +5V

15
2 2 2 L1DF010
2

3 3 3 GND
1

SMP-04V-NC SMR-04V-N 179228-3


1 1 1 +5V
2 2 2 L1DF201
3 3 3 GND
4 4

SMP-06V-NC SMR-06V-N 179228-3


1 1 1 +5V

MX-LC13 OPERATIONAL DESCRIPTIONS 4 - 7


L1DD004

LCT MAIN PWB


2 2 2 L1DF004
3 3 3 GND
4 4
5 5 179228-3
6 6 1 +5V
2 L1DF005
CN-T B18B-PHDSS-B 3 GND
GND 4
+5V 8
L1DD003 9
GND 10 179228-3
+5V 11 1 +5V
L1DD004 12 2 L1DD004
GND 13 3 GND PAP-07V-S
+24V 14 1 +24V
P_GND 15 2 P_GND
L1MT001-CLK 16 3 N.C.
L1MT001 17 4 L1MT001-CLK
L1MT001-T 18 5 L1MT001
6 N.C.
L1CL202

7 L1MT001-T

BU02P-TR-P-H
CN-R B40B-PNDZS-1 PHNR-02-H PHNR-02-H
L1DD002_R_F4 5 1 2 +24V
L1CL202 6 2 1 L1CL202
L1MT001

BU02P-TR-P-H
CN-H B40B-PNDZS-1 PHNR-02-H PHNR-02-H
L1DD002_R_F4 5 1 2 +24V
L1CL102

L1CL102 6 2 1 L1CL102
Signal name Name Function/Operation
L1CL102 1CS transport clutch Controls ON/OFF of the 1CS transport roller.
L1CL202 2CS transport clutch Controls ON/OFF of the 2CS transport roller.
L1DD003 Transport open/close sensor 1 Detects open/close of the transport paper guide.
L1DD004 Transport open/close sensor 2 Detects open/close of the transport paper guide.
L1DD005 Vertical transport open/close sensor Detects open/close of the vertical transport paper guide.
L1DF001 Vertical transport sensor 1 Detects transport of paper.
L1DF002 Vertical transport sensor 2 Detects transport of paper.
L1DF003 Vertical transport sensor 3 Detects transport of paper.
L1DF004 Vertical transport sensor 4 Detects transport of paper.
L1DF005 LCT paper exit sensor Detects transport of paper.
L1DF010 Horizontal transport sensor 5 Detects transport of paper.
L1DF101 1CS paper exit sensor Detects transport of paper.
L1DF201 2CS paper exit sensor Detects transport of paper.
L1DFB01 Manual feed paper entry sensor Detects transport of paper.
L1MT001 Transport motor 1 Drives the paper feed and the transport section.

No. Name Function/Operation


1 Transport roller 1 (Idle) Apply a pressure to paper and the transport roller, providing a transport power to the
transport roller.
2 Transport roller 1 (Drive) Transports paper from the paper feed tray to the transport roller 4.
3 Transport roller 3 (Drive) Transports paper from the manual paper feed tray to the transport roller 4.
4 Transport roller 3 (Idle) Apply a pressure to paper and the transport roller, providing a transport power to the
transport roller.
5 Transport roller 4 (Drive) Transports paper to the transport roller 5.
6 Transport roller 4 (Idle) Apply a pressure to paper and the transport roller, providing a transport power to the
transport roller.
7 Transport roller 5 (Drive) Transports paper to the transport roller 6.
8 Transport roller 5 (Idle) Apply a pressure to paper and the transport roller, providing a transport power to the
transport roller.
9 Transport roller 6 (Drive) Transports paper to the transport roller 7.
10 Transport roller 6 (Idle) Apply a pressure to paper and the transport roller, providing a transport power to the
transport roller.
11 Transport roller 8 (Idle) Apply a pressure to paper and the transport roller, providing a transport power to the
transport roller.
12 Transport roller 8 (Drive) Transports paper to the transport unit.
13 Transport roller 7 (Idle) Apply a pressure to paper and the transport roller, providing a transport power to the
transport roller.
14 Transport roller 7 (Drive) Transports paper to the transport roller 8.
15 Transport roller 9 (Idle) Apply a pressure to paper and the transport roller, providing a transport power to the
transport roller.
16 Transport roller 9 (Drive) Transports paper to the transport roller 7.
17 Transport roller 2 (Idle) Apply a pressure to paper and the transport roller, providing a transport power to the
transport roller.
18 Transport roller 2 (Drive) Transports paper from the paper feed tray to the transport roller 7.

MX-LC13 OPERATIONAL DESCRIPTIONS 4 - 8


[5] MAINTENANCE
1. Paper feed section
: Check (Clean, replace, or adjust according to necessity.) : Clean : Replace : Adjust : Lubricate
When Every
Unit No. Maintenance part Remarks
calling 300K
Paper feed tray 1 Belts ---
2 Sensors
Paper feed unit 3 Paper feed belt  Clean with a water dampened cloth.
4 Sensors
--- Transport paper guides  

3
1

2
2

3
1

2
2

MX-LC13 MAINTENANCE 5 - 1
2. Transport section
: Check (Clean, replace, or adjust according to necessity.) : Clean : Replace : Adjust : Lubricate
When Every
Unit No. Maintenance part Remarks
calling 300K
Vertical transport unit 1 Transport roller 1  Clean with a water dampened cloth.
2 Transport roller 2 
3 Transport roller 3 
4 Transport roller 4 
5 Transport roller 5 
6 Transport roller 6 
7 Transport roller 7 
8 Transport roller 8 
9 Transport roller 9 
10 Belts ---
11 Sensors
--- Transport paper guides  

11

3
1

10

10

4
11
5 10

11
8
7

11

11
2
11
9
6
10

MX-LC13 MAINTENANCE 5 - 2
3. Drive section
: Check (Clean, replace, or adjust according to necessity.) : Clean : Replace : Adjust : Lubricate
When Every
Unit No. Maintenance part Remarks
calling 300K
Upper paper feed drive unit 1 Belts ---
Main drive unit 2 Belts ---
Lower paper feed drive unit 3 Belts ---

MX-LC13 MAINTENANCE 5 - 3
[6] DISASSEMBLY AND ASSEMBLY
1. Each unit disassembly 2) Remove the screw, and remove the right cabinet.

A. Exterior section
No. Unit name
1 Rear cabinet
1
2 Right cabinet
3 Upper cabinet left
4 Left front cabinet 1
2
5 Left rear cabinet

1
3
1
1

1
4
2
1

(3) Upper cabinet left


5 1) Open the left door.

(1) Rear cabinet


1) Disconnect the power cord. Loosen the screws at the bottom
ends. Remove the screw, and remove the rear cabinet.

3
3
4

1
3

2) Remove the cap. Remove the screw, and remove the upper
cabinet left.

3 1
2
2

1
2
(2) Right cabinet
1) Remove the screw, and remove the right cabinet lower cover.

3
2
2

MX-LC13 DISASSEMBLY AND ASSEMBLY 6 - 1


2 : ‘14/Jul
(4) Left door B. Paper feed section
1) Remove the upper cabinet left. No. Unit name
2) Open the left door. 1 Paper feed tray
2 Paper feed unit
3 Paper feed belt 2
4 Paper feed duct unit

1
2

1
2

3) Remove the resin E-ring, and remove the shaft. Remove the
left door. (1) Paper feed tray
1) Remove the right cabinet.
2) While releasing lock of the paper feed tray bottom, pull out the
paper feed tray.

2
2

3
1
2
1

3) Remove the screws at the back side of the paper feed tray,
and remove the binding band and the earth wire.
(5) Left rear cabinet Disconnect the connector.
1) Remove the rear cabinet.
2) Remove the screw, and remove the left rear cabinet

3
1
2
1
1

2 1

MX-LC13 DISASSEMBLY AND ASSEMBLY 6 - 2


2 : ‘14/Jul
4) Remove the screws at the both sides of the paper feed tray, 3) Remove the screw, and remove the paper feed unit.
and remove the paper feed tray from the slide rail.

2
1

2 1

1
(3) Paper feed belt 2
1) Remove two screws from the suction duct front frame/top side
of the Unit.

(2) Paper feed unit



1) Remove the screws of the rear cabinet, and remove the cover.
Disconnect the connector from the paper feed unit. 

2 2) Turn the unit over and remove two screws from the blower
3
duct; rear side/bottom of the unit.

2 

2) While releasing lock of the paper feed tray bottom, pull out the
paper feed tray.
3) Disconnect 3 connectors and remove the band.

1
2

MX-LC13 DISASSEMBLY AND ASSEMBLY 6 - 3


2 : ‘14/Jul
2 5) Remove 3 screws 2 ground screws and ground plate from the NOTE: Replace all four belts at the same time. 2
mounting plate. NOTE: Replace them with new ones one at a time without
 damaging the belts.
NOTE: Insert the belt to the position A and slide it to the allow
B direction as the photo below.
NOTE: Never stretch it out too much to prevent the belt trans-

formation.
5VLGH 3DSHU)HHGXQLW
)VLGH
$

*When installing the unit, make sure not to drop and lose the %
grounding plate. Put it aside for later installation.
NOTE: Never insert the belts horizontally by force, in order not
6) Before moving the Follower roller shaft, make sure that you to transform the belts.
pull the solenoid arm out of the slot.

8QLW)6LGH

7) Lift and move the follower roller shaft to the center of the unit to
release the tension on the belt. And then remove the E-clips of 8QLW)6LGH
the both side of the follower shaft..
(4) Paper feed duct unit
 1) Remove the rear cabinet.
2) Disconnect the connector of the fan and clutch. Remove the
screw, and remove the binding band.


1
1
8) Remove the bearings of the both side and remove the follower
roller shaft out of the slot to allow the belt to slide out. 2

3

1
1


3) Remove the screw, and remove the paper feed duct unit.
1 1

9) Slide the belts out one by one.


1

1
1

1
2

MX-LC13 DISASSEMBLY AND ASSEMBLY 6 - 4


C. Transport section 8) Disconnect the connector of the switch and sensor. Remove
the screw, and remove the connection unit. Remove the snap
No. Unit name
band, and disconnect the connector of the connection unit.
1 Vertical transport unit

1
5

2
4

1 2

2
1

9) Remove the screw, and remove the handle.


(1) Vertical transport unit
1) Remove the rear cabinet.
2) Remove the left door.
2
3) Remove the left rear cabinet.
4) Remove the paper feed tray.
5) Remove the paper feed unit. 1
6) Remove the E-ring, and remove the knob. Remove the screws
and remove the inside cabinet left upper.

10) Disconnect the connector of the vertical transport unit.

1
2 3

4 11) Remove the screws fixing the vertical transport unit.


3

7) Remove the E-ring, and remove the knob. Remove the screws
and remove the inside cabinet left lower.

1
2 4
3

MX-LC13 DISASSEMBLY AND ASSEMBLY 6 - 5


12) Remove the vertical transport unit. 3) Disconnect the connector of the clutch. Remove the screws,
and remove the upper paper feed drive unit.
3 2

1
2
1

(2) Main drive unit


1) Remove the rear cabinet.
2) Remove the E-ring, the pulley, the parallel pin, and the belt.
D. Drive section
No. Unit name
1 Upper paper feed drive unit 3
2 Main drive unit
3 Lower paper feed drive unit 6
5
4
2
1

3) Disconnect the connector of the motor. Remove the screw, and


2 remove the main drive unit.
3 2 2

(1) Upper paper feed drive unit


1) Remove the rear cabinet.
2) Remove the E-ring, the pulley, and the belt. 1

2 2

3 (3) Lower paper feed drive unit


2 1) Remove the rear cabinet.
2) Remove the E-ring, the pulley, and the belt.
1

3
2
1

MX-LC13 DISASSEMBLY AND ASSEMBLY 6 - 6


3) Disconnect the connector of the clutch. Remove the screws, (2) DC power PWB
and remove the lower paper feed drive unit. 1) Disconnect the connector from the DC power PWB. Remove
the screw, and remove the DC power PWB.
3 2
1 2 1

1 2
2

1
3
2

1
2 2
1
1

E. PWB section
No. Unit name 1
1 Main PWB
2 DC power PWB 2 2
3 Heater relay PWB
4 AC PWB
(3) Heater relay PWB
1) Disconnect the connector from the heater relay PWB. Remove
the screw and the supporter, and remove the heater relay
PWB.

2 2
1 1

3 3
1
4 1 4
2
2
3
2
1 1

(1) Main PWB (4) AC PWB


1) Disconnect the connector from the main PWB. Remove the 1) Disconnect the connector from the AC PWB. Remove the
screw and the supporter, and remove the main PWB. screw, and remove the AC PWB.

2 1 2 1 2 3
2

1 2
4
1 2
1 1
1
3 3
2
2
1 1

2 1 2 1 2

MX-LC13 DISASSEMBLY AND ASSEMBLY 6 - 7


2. Maintenance b. Transport roller 7, Transport roller 8
1) Open the left door.
A. Paper feed section
(1) Paper feed unit
a. Paper feed belt
1) Clean the paper feed belt.

B. Transport section
2) Open the paper guide.
(1) Vertical transport unit Clean the transport roller 7 and the transport roller 8.
a. Transport roller 3, Transport roller 4, Transport roller 5,
Transport roller 6
1) Open the left door.

c. Transport roller 2
1) Open the left door.

2) Open the paper guide.


Clean the transport roller 3, the transport roller 4, the transport
roller 5 and the transport roller 6.

MX-LC13 DISASSEMBLY AND ASSEMBLY 6 - 8


2) Open the paper guide.
Clean the transport roller 2.

d. Transport roller 1, Transport roller 9


1) Clean the transport roller 1 and the transport roller 9.

MX-LC13 DISASSEMBLY AND ASSEMBLY 6 - 9


[7] ADJUSTMENT
The following service parts are needed to be adjust.
• Air pressure meter LCT: UKOG-0342FCZZ
• Tube for air pressure meter LCT: UKOG-0343FCZZ

1. Paper feed section adjustments Measuring method


1) With the LCT left front door open, turn ON the door SW.
Check to confirm that the pointer of the pressure display section of
2) Pull out the LCT cassette.
the air pressure meter is at “0” (Pa).
If not, turn the correction knob to set at “0” (Pa). 3) Put standard paper (60 - 80g paper) of A4/LT in landscape to
the LCT cassette, and close the cassette.
4) Check to confirm that the paper feed table reaches the paper
Suction pressure feed point, and enter the simulation shown below.
measuring side: Blue Upper stage check: Select “L1CHK101” of Sim4-3.
Lower stage check: Select “L1CHK201” of Sim4-3.
Overall

Blowing pressure
measuring side: Red

Suction side
The table below shows the specified ranges at the measuring
points of air pressure.
LCT cassette 1 LCT cassette 2
Suction duct*1 A 130 - 230 C 130 - 230
Blowing duct B 310 - 410 D 310 - 410
Simulation No. Sim4-3 Sim4-3
Unit (Pa)
*1 : The air pressure of the suction duct must be measures with
paper attached to the paper feed belt.

When the measured value of the air pressure is outside the speci-
fied range, check the following items.
• Does the blower fan rotate?
• Are the valves opened and closed smoothly?
• Is the connector to the rear frame connected securely?
• Is the solenoid installed to the proper position? (Does it operate
smoothly?)
• Are the duct body, the suction duct and the blowing duct not bro-
ken?
• Are the duct body, the suction duct, the blowing duct, the blower
fan, and the duct joint tightened by screws firmly?
• Is there no air leak in the sound-muffling duct, between the
blower fan, and in the duct joint?

MX-LC13 ADJUSTMENT 7 - 1
Blowing side Blowing side

6) When the air pressure is in the specified range, cancel the pro-
5) Insert a tube into the measuring point to measure. (For an gram with “EXECUTE.”
actual measuring, attach the toll to the machine.)
7) When the air pressure is outside the specified range, adjust in the
Check to confirm that the tube is securely inserted, and then
following procedures.
measure.
When the values of “B VACUUM FAN DUTY(PLAIN-M)” and “T
Suction side BLOWER FAN DUTY (PLAIN-M)” in Sim4-11 are changed, they
are reflected to the measured value of the above Sim4-3.
By increasing the vacuum fan duty and the blower fan duty values
in the simulation, the suction pressure is increased.
(The vacuum fan duty and the blower fan duty values must be
changed to the same value. Example: When B is 60, make T 60.)
Since the blowing pressure is also increased, be sure to check
the blowing pressure after adjustment of the suction pressure.
By decreasing the vacuum fan duty and the blower fan duty val-
ues in the simulation, the suction pressure is decreased.
(The vacuum fan duty and the blower fan duty values must be
changed to the same value. Example: When B is 40, make T 40.)
Since the blowing pressure is also decreased, be sure to check
the blowing pressure after adjustment of the suction pressure.
NOTE: Though the duty setting in Sim4-11 can be changed
according to the size and the paper type, it is not
reflected to the measured value of the above Sim4-3.
Note that carefully.

MX-LC13 ADJUSTMENT 7 - 2
TopPage
1 : ‘13/Dec

[8] ELECTRICAL SECTION


1. Block diagram
A. Overall

LCT main unit

Main unit Interface UN


LCT MAIN PWB 3.3V
Manual paper feed UN

Communication Communication
Communication circuit with main unit (main unit connection cable) circuit with 5V
circuit with LCT
main unit

5V CPU
24V
Communication
circuit with
second series

LDSW_R_F4
Interface unit transport clutch
䠄24V䠅
Clock

24V Spectrum
diffusion circuit Tray lift motor
control circuit

1CS UN Reverse rotation


detection SW Stepping motor
control circuit

Lower limit sensor


Upper limit sensor 5V
Lift motor RE sensor F7
Width sensor 1 24V
Width sensor 2
Width sensor 3
Paper top surface sensor
Length sensor
1 Paper rear edge sensor 24V
5V
Assist fan Horizontal transport sensor UN
motor 1

Solenoid/clutch
drive circuit

Assist fan
motor 2
LDSW_R_F4
䠄24V䠅
Assist fan motor
drive circuit
Lift motor
Vertical transport UN
Manual feed paper entry sensor
OUT1 Lift motor Vertical transport sensor 3
Tray SW PWB Vertical transport sensor 2
5V drive circuit
OUT2 Vertical transport sensor 1
SW 1CS paper exit sensor
LED 1CS descending side power Vertical transport open/close
+24V_F5 F5 sensor
Tray lock/ 24V 2CS descending side power
lock release SOL
Horizontal transport sensor 5
1CS lifting side power
Tray lock sensor 5V Vertical transport sensor 4
2CS paper exit sensor
2CS lifting side power
LCT paper exit sensor
LDSW_R_F4 Transport open/close sensor 2
Transport open/close sensor 1
䠄24V䠅 LCT machine connection detection
Sensor input
circuit F4
1CS transport clutch
2CS transport clutch

F1 LDSW_R_F1 1CS paper feed clutch


2CS UN 2CS paper feed clutch
Reverse rotation 䠄24V䠅
detection SW Open/close SW
detection circuit LCT front door open
detection SW
24V
Lower limit sensor 1CS insertion detection SW 1
Upper limit sensor 5V 24V PSW
Lift motor RE sensor
Width sensor 1
Width sensor 2
1CS paper feed UN
Width sensor 3 1CS upper limit
Paper top surface sensor protection SW
Length sensor
1 Paper rear edge sensor
1CS paper empty
5V
detection sensor
Assist fan
motor 1 1CS suction valve
solenoid
1CS blowing port
temperature sensor
Tray SW PWB AC100V
1CS heater unit (350W)
Assist fan I/F circuit From
motor 2 1CS heater temperature AC relay
24V
To A/D conversion sensor installation detection PWB
section of CPU
24V PSW 2CS insertion detection SW1
Lift motor
2CS paper feed UN 2CS upper limit
12V Buffer AMP protection SW
circuit
Tray SW PWB 5V
SW
LED 5V 2CS paper empty
+24V_F5 䠄24V䠅 Thermistor Open detection sensor
Tray lock/
detection circuit
lock release SOL 2CS suction valve solenoid

Tray lock sensor 5V


2CS blowing port
Abnormal heating temperature sensor
protection circuit 2CS heater unit (350W) AC100V
From
2CS heater temperature AC relay
sensor installation detection PWB
1CS insertion detection SW2
䠄24V䠅 LCT inside temperature/
24V 5V humidity sensor

2CS insertion detection SW2 F9 24V


1CS suction
L1PW001 5V fan motor
PR drive for +24V_F5
thermal heater F8 24V
1CS exhaust
䠄24V䠅 fan motor
L1DT116_R
To LCT AC 䠄24V䠅
relay PWB L1DT216_R Suction/paper exit F2 24V
HL_PR1 fan motor 2CS suction
Hot-air heater
HL_PR2 drive circuit fan motor
control circuit
L1HT101
F3 24V
L1HT201 2CS exhaust
5V fan motor

S_GND F6 24V
Power unit
Refer to the block diagram 㻞㻠䠲 cooling fan
of the primary side of motor
AC, the heater From DC power unit P_GND
relay and the 24V
12V
DC power section.
Transport motor Transport
S_GND control circuit motor
3.3V

MX-LC13 ELECTRICAL SECTION 8 - 1


High frequency reactor
* Only for Europe 200V
series
B. Power section

AC inlet DC power UN 24V power


CN4 LCT MAIN PWB
section CN101 24V
AC L CN2
AC L
AD input of CPU
CN102 P-GND
CN-A
AC N 5V
CN1 12V power
CN4
SGND
CN1 section 12V Power Hot-air Solenoid
24V Buffer circuit
CN103 cooling FAN heater clutch
PGND for thermistor
D-GND drive circuit control circuit drive circuit
CN3 12V
AC PWB CN6 AC N SGND
5V power 24V
5V 3.3V
section CN104
D-GND
CN-B CN-R CN-H
Thermal heater SW
AC L AC N FW 3.3V power
CN2 section CN105 3.3V
CN3 4䇭3䇭2䇭1

FW

CN 䌆 CN 䌈 CN 䌉 LCT heater, Relay PWB


CN E

Thermal heater 2CS 䋨10W䋩 R䌙3 24V


RY2
R䌙4 Power cooling
FAN
Thermal heater 1CS 䋨10W䋩

L1HT10䋱 L1HT201
CN 䌁

CN D 1 /HLPR2 L1D䌔216_R(24V)

Thermal heater bottom surface 1䋨10W䋩 2 L1DT216_R (24V)


3 /䌈䌌PR1
4 P-GND
RY1 5 L1DT116_R (24V)
L1D䌔116_R(24V)
Thermal heater bottom surface 2 䋨10W䋩 6 L1HT101
7 S-GND
8 L1HT201
9 S-GND
P_GND 24V 10 L1PW001

MX-LC13 ELECTRICAL SECTION 8 - 2


Thermal heater bottom surface 3 (10W䋩
L1D䌔116_R(24V)
11 24V_F5
24V_F5 L1D䌔216_R(24V) 24V
RY3 RY4
L1PW001
/HL_PR1 /HL_PR2
CN C
CN B
CN 䌇 CN J

Main unit P_GND


connector 2CS paper feed UN 350W Thermostat
24V
(ELP-15V) 2CS hot-air heater Thermistor for measuring temperature of 2CS hot-air heater

Communication line 1CS paper feed UN 350W


To LCT MAIN PWB Thermostat
with main unit P_GND 1CS hot-air heater Thermistor for measuring temperature of 1CS hot-air heater
24V
LCT second
series connector
(ELR-15V)

To LCT MAIN PWB 䇭Communication line


with second series
2. Actual wiring diagram

2CS PAPER FEED UN


PS-187
+24V
L1DT202 PS-187 SMP-08V-NC SMR-08V-N
L1DT202_R 1 1
2 2
179228-3 3 3
+5V 1 4 4
L1DT203 L1DT203 2 5 5
GND 3 6 6 CN-V B08B-PH-K-S
7 7 1 +5V
SMR-03V-N SMP-03V-NC 8 8 2 L1DA206
+24V 1 1 3 GND
L1SL201
L1SL201 3 3 4 L1DA205
5 GND
6 L1DT218
7 +5V
SMR-02V-N SMP-02V-NC SMP-06V-NC SMR-06V-N 8 N.C.
L1DA202 1 1 1 1
L1DA202
GND 2 2 2 2
3 3
SMR-04V-N SMP-04V-NC 4 4
2CS warm air heater 1 1 5 5
temperature sensor 1 2 2 6 6
3 3
4 4

L1HT201
ELP-03V ELR-03V ELR-03V ELP-03V
1 1 1 1 HRL2
2 2 2 2
3 3 3 3
CN-R B40B-PNDZS-1 L1DT201_R
HRN2 1 L1DT201_R
2 L1DT202_R
3 P_GND
4 P_GND L1DD002_R_F4
5 L1DD002_R_F4
6 L1CL202 L1DD002_R_F1
7 L1DD002_R_F1
8 L1CL201
9 L1DD002_R_F1
10 L1SL201
BU02P-TR-P-H
11 P_GND
PHNR-02-H PHNR-02-H
12 P_GND
+24V 2 1
L1CL202 13 +5V
L1CL202 1 2
14 GND
BU02P-TR-P-H 15 L1DT203
PHNR-02-H PHNR-02-H 16 GND
+2 4 V 2 1 17 GND
L1CL201
L1CL201 1 2 18 L1MT202-24V
19 L1MT202
20 L1MT202-T
SMR-04V-N SMP-04V-NC
21 L1MT203-24V
L1MT202-24V 1 1
22 L1MT203
L1MT202 2 2
L1MT202 23 L1MT203-T
P_GND 3 3
24 YOBI6
L1MT202-T 4 4
25 YOBI7
26 YOBI8
SMR-04V-N SMP-04V-NC 27 YOBI9
L1MT203-24V 1 1 28 +24V
L1MT203 2 2 29 L1MT205
L1MT203
P_GND 3 3 30 L1MT205-T
L1MT203-T 4 4 31 L1DO201
32 +5V
33 L1DA207+
34 GND
35 GND
36 L1DA201
37 GND
38 L1DA202
39 GND
40 GND

MULTI PAPER FEED UN

51067-0400 51114-0400(MOLEX) SMR-04V-N SMP-04V-NC CN-F B18B-PHDSS-B


1 1 1 1 1 GND
2 2 2 2 2 P_GND
3 3 3 3 3 +5V_D
4 4 4 4 4 +24V
5 GND
53358-1440(MOLEX) BU14P-TZ-S 6 L1DO004
52484-1410 51090-1400 CZHR-14V-S CZHR-14V-S 7 +5V
14 1 14 1 8 N.C.
13 2 13 2 9 N.C.
12 3 12 3 10 +5V
11 4 11 4 11 M1MTS
10 5 10 5 12 GND
9 6 9 6 13 L1MPFM B/
8 7 8 7 14 COM_B
7 8 7 8 15 L1MPFM B
6 9 6 9 16 L1MPFM A/
5 10 5 10 17 COM_A
4 11 4 11 18 L1MPFM A
3 12 3 12
2 13 2 13
1 14 1 14

3-292254-1(BLUE)(AMP) BU11P-TZ-S
3-179228-1(BLUE) 3-179228-1(BLUE) CZHR-11V-S CZHR-11V-S CN-E B24B-PHDSS-B
11 1 11 1 1 L1MSLIDE
10 2 10 2 2 L1MLED
9 3 9 3 3 L1MLSW
8 4 8 4 4 L1MPRM-D
7 5 7 5 5 L1MPRM-U
6 6 6 6 6 L1MPUS
5 7 5 7 7 L1MREVM-CLK
4 8 4 8 8 L1MREVM-MODE3
3 9 3 9 9 L1MPUM-CLK
2 10 2 10 10 L1MPUM-MODE3
1 11 1 11 11 L1MPUM-RSET
12 M1MLLS
13 L1MPES
1-292254-2(AMP) BU12P-TZ-S
14 L1MSIZ5
1-179228-2 1-179228-2 CZHR-12V-S CZHR-12V-S
15 L1MSIZ4
12 1 12 1
16 L1MSIZ3
11 2 11 2
17 L1MSIZ2
10 3 10 3
18 L1MSIZ1
9 4 9 4
19 L1MPVS2
8 5 8 5
20 L1MPVS1
7 6 7 6
21 L1MPFS
6 7 6 7
22 L1MLS
5 8 5 8
23 L1MULS
4 9 4 9
24 GND
3 10 3 10
2 11 2 11
1 12 1 12
LCT MAIN PWB

MX-LC13 ELECTRICAL SECTION 8 - 3


RELAY UN
ELP-15V ELR-15V ELP-15V ELR-15V
CN-C B09B-PASK-1 LCC_D 1 1 LCC_D 1 1 LCC_D
L1DO005 1 L1DO005 2 2 L1DO005 2 2 N.C.
DSR-LCT 2 TXD-LCT 3 3 TXD-LCT 3 3 TXD-LCT
RXD-LCT 3 RXD-LCT 4 4 RXD-LCT 4 4 RXD-LCT
L1DFTRC 4 DTR-LCT 5 5 DTR-LCT 5 5 DTR-LCT
RES-LCT 5 DSR-LCT 6 6 DSR-LCT 6 6 DSR-LCT
DTR-LCT 6 RES-LCT 7 7 RES-LCT 7 7 RES-LCT
TXD-LCT
L2DFTRC2
7
8
F.G.
N.C.
8
9
8
9
F.G.
N.C.
8
9
8
9
F.G.
+5V
MAIN UN
GND 9 GND 10 10 GND 10 10 GND
+24V_RY 11 11 +24V_RY 11 11 +24V
GND_RY 12 12 GND_RY 12 12 GND
L1DFTRC 13 13 L1DFTRC 13 13 L1DFTRC
L2DFTRC2 14 14 N.C. 14 14 N.C.
N.C. 15 15 N.C. 15 15 N.C.

L1DD002_R_F4 CN-U B30B-PHDSS-B XADR-32V XADRP-32V


L1DD002_R_F4 1 1 1
L1CLR01 2 2 2
GND 3 3 3
GND 4 4 4
L1DO004 5 5 5
+5V 6 6 6
L1DDR01 7 7 7
GND 8 8 8
+5VR 9 9 9
L1LDR01 10 10 10
+24V 11 11 11
P_GND 12 12 12
LTMTR01-CLK 13 13 13
LTMTR01 14 14 14
LTMTR01-T 15 15 15
+5V 16 16 16
L1DDR03 17 17 17
GND 18 18 18
+5V 19 19 19
L1DFR01 20 20 20
GND 21 21 21
+5V 22 22 22
L1DFR02 23 23 23
GND 24 24 24
+5V 25 25 25
L1DFR03 26 26 26
GND 27 27 27
+5V 28 28 28
L1DDR02 29 29 29
GND 30 30 30
31 31
32 32

DC POWER UN
CN-A B8P-VH
CN-101 B8P-VH-B
+5V 1
1 +24V
GND
+24V
2
3 CN-102 B7P-VH-B 200V Series only
P_GND 4 1 P_GND
+12V 5
CN-103 B5P-VH-B CN-4 B2P3-VH-B-E(BL) ELP-02V ELR-02V
GND 6
1 +12V LiveR out 1 1 1
+3.3V 7 Reactor
4 GND N.C. 2 2 2
GND 8
LiveR in 3
CN-104 B9P-VH-B
2 GND
5 +5V
CN-105 B4P-VH-B CN-1 B03P-VL-R(RD)
1 +3.3V AC-L(IN) 1
4 GND N.C. 2
AC-N(IN) 3
CN-B B14B-PHDSS-B CN-3 B04B-PASK-1
FW 1 4 FW
P_GND 2
L1MT002(+24V) 3 Dehumidifying heater switch
L1MT002-T 4 SMP-03V-NC SMR-03V-N PS-187
L1HT101 5 1 1 L1MT002(+24V)
+24V_F5 L1HT201 6 2 2 P GNDL1MT002 L1MT002 PS-187
+24V_F5 7 3 3 L1MT002-T
L1PW001 8
/HL_PR1 9
/HL_PR2
P_GND
10
11
CN-A
1
B11B-PASK-1
/HL PR2 RELAY PWB AC PWB
L1DT116_R GND 12 2 L1DT216_R CN-5
L1DT116_R 13 3 /HL PR1 CN-H B03P-VL CN-2 B03P-VL-K(BK) B03P-VL-E(BL)
L1DT216_R 14 4 P GND AC-L(IN) 1 1 AC-N(OUT) AC-L(OUT) 1
L1DT216_R 5 L1DT116_R N.C. 2 2 N.C. N.C. 2
6 L1HT101 AC-N(IN) 3 3 AC-L(OUT) AC-N(OUT) 3
7 GND
8 L1HT201
9 GND
CN-I B03P-VL-K(BK) CN-3 B03P-VL-R(RD)
10 L1PW001
AC-L(OUT) 1 1 AC-L(IN)
11 +24V_F5
N.C. 2 2 N.C.
AC-N(OUT) 3 3 AC-N(IN)
CN-B B3B-PH-K-S
1 +24V_RY
2 N.C.
3 GND_RY
CN-F B2P3-VH CN-6 B2P3-VH-RD CN-1 B03P-VL(WH)
CN-CB4B-PH-K-S AC-L_H(IN) 1 1 AC-N_H(OUT) AC-L(IN) 1
+24V_RY 1 +24V_RY N.C. 2 2 N.C. N.C. 2
GND_RY 2 N.C. AC-N_H(IN) 3 3 AC-L_H(OUT) AC-N(IN) 3
3 GND_RY
4 N.C.
CN-E B4P(5-3)-VH
CN-JB03P-VL-E(BL) KWL_1 1
HRL1 1 HRL1 KWL_2 2
L L
HRN1 2 N.C. N.C. 3
FG FG
3 HRL2 KWN_1 4
N N
KWN_2 5
HRL2 CN-G B03P-VL-R(RD)
HRN2 1 HRN2 CN-D B2P3-VH-R
2 N.C. KWL_3 1
3 HRN1 N.C. 2 ELP-02V ELR-02V
KWN_3 3 1 1
Dehumidifying heater 3
2 2

ELR-02V ELP-02V ELP-02V ELR-02V


LCT MAIN PWB 1CS dehumidifying heater
1
2
1
2
1
2
1
2
Dehumidifying heater 4

ELR-02V ELP-02V ELP-02V ELR-02V


1 1 1 1
2CS dehumidifying heater Dehumidifying heater 5
2 2 2 2

MX-LC13 ELECTRICAL SECTION 8 - 4


LCT humidity sensor PHR-4
+5V 1
L1DA001 L1DA002 2
L1DA002 GND 3
L1DA001 4

1CS PAPER FEED UN


PS-187
+24V
L1DT102 SMP-08V-NC SMR-08V-N
L1DT102_R 1 1
2 2 CN-G B16B-PHDSS-B
179228-3 3 3 1 +5V
+5V 1 4 4 2 L1DA002
L1DT103 L1DT103 2 5 5 3 GND
GND 3 6 6 4 L1DA001
7 7 5 +5V
SMR-03V-N SMP-03V-NC 8 8 6 L1DA106
+24V 1 1 7 GND
L1SL101
L1SL101 3 3 8 L1DA105
9 GND
10 L1DT118
11 +5V
SMR-02V-NSMP-02N-NC SMP-06V-NCSMR-06V-N 12 GND
L1DA102 1 1 1 1 13 GND
L1DA102
GND 2 2 2 2 14 GND
3 3 15 N.C.
SMR-04V-N SMP-04V-NC 4 4 16 N.C.
1CS warm air heater 1 1 5 5
temperature sensor 1 2 2 6 6
3 3
4 4

L1HT101
ELP-03V ELR-03V ELR-03V ELP-03V
1 1 1 1 HRL1
2 2 2 2
CN-H B40B-PNDZS-1 L1DT101_R
3 3 3 3 HRN1 1 L1DT101_R
2 L1DT102_R
3 P_GND
4 P_GND L1DD002_R_F4
5 L1DD002_R_F4
6 L1CL102 L1DD002_R_F1
7 L1DD002_R_F1
8 L1CL101
9 L1DD002_R_F1
10 L1SL101
BU02P-TR-P-H
11 P_GND
PHNR-02-H PHNR-02-H
12 P_GND
+24V 2 1
L1CL102 13 +5V
L1CL102 1 2
14 GND
BU02P-TR-P-H 15 L1DT103
PHNR-02-H PHNR-02-H 16 GND
+2 4 V 2 1 17 GND
L1CL101
L1CL101 1 2 18 L1MT102-24V
19 L1MT102
20 L1MT102-T
SMR-04V-N SMP-04V-NC
21 L1MT103-24V
L1MT102-24V 1 1
22 L1MT103
L1MT102 2 2
L1MT102 23 L1MT103-T
P_GND 3 3
24 +24V
L1MT102-T 44
25 L1MT003-CLK
26 L1MT003
SMR-04V-N SMP-04V-NC 27 L1MT003-T
L1MT103-24V 1 1 28 +24V
L1MT103 2 2 29 L1MT105
L1MT103
P_GND 3 3 30 L1MT105-T
L1MT103-T 4 4 31 L1DO101
32 +5V
33 L1DA107+
34 GND
35 GND
36 L1DA101
37 GND
38 L1DA102
39 GND
40 GND

2 connection LCT

ELP-15V ELR-15V
1 1 N.C. CN-N B12B-PASK-1
2 2 L1DO005 1 L1DO005(GND)
3 3 TXD-LCT2 2 DSR-LCT2
4 4 RXD-LCT2 3 RXD-LCT2
5 5 DTR-LCT2 4 L2DFTRC1
6 6 DSR-LCT2 5 RESET_2
7 7 RESET_2 6 DTR-LCT2
8 8 F.G. 7 TXD-LCT2
9 9 N.C. 8 L2DFTRC3
10 10 GND 9 GND
11 11 +24V_RY 10 GND
12 12 GND_RY 11 N.C.
13 13 L2DFTRC1 12 N.C.
14 14 L2DFTRC3
15 15 N.C.

CN-M B12B-PHDSS-B
1 RES
2 +3.3V
3 TXD1
SMR-02V-NSMP-02V-NC 4 RXD1
1 1 +24V_RY 5 SCK1
2 2 GND_RY 6 MD1
7 MD0
8 +3.3V
9 RES_LCT
10 GND
11 GND
12 N.C.

CN-L B4B-EH
1 +5V
2 GND
3 RXD6
4 TXD6

LCT MAIN PWB

MX-LC13 ELECTRICAL SECTION 8 - 5


+24V
CN-T B18B-PHDSS-B
+24V_F5 F50.75A GND 1 SMP-02V-NC SMR-02V-N SMP-02V-NC SMR-02V-N PS-187-2V
+24V 2 1 1 1 1 1 +24V
L1DD002
L1DD002_R 3 2 2 2 2 2 L1DD002
L1DD002_R F40.75A GND 4
GND 5 179228-3
L1DD002_R_F4 F10.75A +5V 6 1 +5V
L1DD001 7 2 L1DD001 L1DD001
L1DD002_R_F1 +5V 8 3 GND
L1DD003 9
GND 10
+5V 11
L1DD004 12
GND 13 PAP-07V-S
+24V 14 1 +24V
P_GND 15 2 P_GND
L1MT001-CLK 16 3 N.C.
L1MT001 17 4 L1MT001-CLK L1MT001
L1MT001-T 18 5 L1MT001
6 N.C.
7 L1MT001-T

VERTICAL PAPER TRANSPORT UN


XADR-40V XADRP-40V
1 1
2 2
3 3
4 4
5 5
CN-S B32B-PHDSS-B 6 6
+5V 1 7 7 SMP-03V-NC SMR-03V-N 179228-3
GND 2 8 8 1 1 1 +5V
+5V 3 9 9 2 2 2 L1DFB01 L1DFB01
+5V 4 10 10 3 3 3 GND
L1DD005 5 11 11
L1DFB01 6 12 12 SMP-04V-NC SMR-04V-N 179228-3
+5V 7 13 13 1 1 1 +5V
L1DF101 8 14 14 2 2 2 L1DF101 L1DF101
GND 9 15 15 3 3 3 GND
+5V 10 16 16 4 4
L1DF201 11 17 17
GND 12 18 18 SMP-06V-NC SMR-06V-N 179228-3
+5V 13 19 19 1 1 1 +5V
L1DF001 14 20 20 2 2 2 L1DF001 L1DF001
GND 15 21 21 3 3 3 GND
+5V 16 22 22 4 4
L1DF002 17 23 23 5 5 179228-3
GND 18 24 24 6 6 1 +5V
+5V 19 25 25 2 L1DD005 L1DD005
L1DF003 20 26 26 3 GND
GND 21 27 27
+5V 22 28 28 SMP-06V-NC SMR-06V-N 179228-3
L1DF004 23 29 29 1 1 1 +5V
GND 24 30 30 2 2 2 L1DF002 L1DF002
+5V 25 31 31 3 3 3 GND
L1DF005 26 32 32 4 4
GND 27 33 33 5 5 179228-3
+5V 28 34 34 6 6 1 +5V
L1DF010 29 35 35 2 L1DD003 L1DD003
GND 30 36 36 3 GND
+5VR 31 37 37
L1LD002 32 38 38 SMP-03V-NC SMR-03V-N 179228-3
39 39 1 1 1 +5V
40 40 2 2 2 L1DF003 L1DF003
3 3 3 GND

SMP-03V-NC SMR-03V-N 179228-3


1 1 1 +5V
2 2 2 L1DF010 L1DF010
3 3 3 GND

SMP-04V-NC SMR-04V-N 179228-3


1 1 1 +5V
2 2 2 L1DF201 L1DF201
3 3 3 GND
4 4
SMP-06V-NC SMR-06V-N 179228-3
1 1 1 +5V
2 2 2 L1DF004 L1DF004
3 3 3 GND
4 4
5 5 179228-3
6 6 1 +5V
2 L1DF005 L1DF005
3 GND

179228-3
1 +5V
2 L1DD004 L1DD004
3 GND

HORIZONTAL PAPER TRANSPORT UN

CN-D B20B-PHDSS-B 14P-RIZ-K2GG-RL 14R-RIZ-K4GG-FL


+5V 1 1 14
L1DF006 2 2 13
GND 3 3 12
L1DF007 4 4 11
L1DF008 5 5 10
+5V 6 6 9
L1DF009 7 7 8
+5V 8 8 7
L1DO003 9 9 6
GND 10 10 5
L1DD006 11 11 4
GND 12 12 3
GND 13 13 2
L1DD002_R_F4 L1DD002_R_F4 14 14 1
L1CL001 15
GND 16
YOBI1 17
YOBI2 18
GND 19
GND 20

LCT MAIN PWB

MX-LC13 ELECTRICAL SECTION 8 - 6


TopPage
1 : ‘13/Dec

1CS UN

HRS HRS
DF11-6DS-2C DF11-6DS-2C
+DF11-6DP-SP1(05) +DF11-6DP-SP1(05)

+5V GND
6 5 4 3 2 1 6 5 4 3 2 1
ELR-03V ELP-03V
L1MT101-D 1 1
L1MT101
L1MT101-U 3 3

PS-187-3V
+24V 1
L1DT108
L1DT108 3

PHR-3
+5VR 1
L1DT107 GND 2
L1DT107 3

SMR-03V-N SMP-03V-NC
+5V 1 1
L1DT104 GND 2 2
L1DT104 3 3

SMP-03V-NC SMR-03V-N
+24V 1 1
L1MT104_1 L1MT104_1 2 2
P_GND 3 3

179228-3
+5V 1
L1DT112 L1DT112 2
GND 3

179228-3
+5V 1
L 1 DT1 1 3 L1DT113 2
GND 3

179228-3
+5V 1
L1DT114 L1DT114 2
GND 3

HRS HRS
DF11-6DS-2C DF11-6DS-2C
+DF11-6DP-SP1(05) +DF11-6DP-SP1(05)

+5V GND
6 5 4 3 2 1 6 5 4 3 2 1

BU10P-TR-P-H
PHR-4 SMR-04V-N SMP-04V-NC PHNR-10-H PHNR-10-H
+5VR 1 1 1 1 10
L 1 L D1 0 1 L1LD101 2 2 2 2 9
L1DT109 L1DT109 3 3 3 3 8
GND 4 4 4 4 7
5 6
179228-3 6 5
+5V 1 7 4
L1DT110 L1DT110 2 8 3
GND 3 9 2
BU16P-TR-P-H 10 1
179228-3 PHNR-16-H PHNR-16-H
+5V 1 1 16
L 1 DT1 0 5 L1DT105 2 2 15 BU12P-TR-P-H
GND 3 3 14 PHNR-12-H PHNR-12-H
4 13 1 12
SMR-03V-N SMP-03V-NC 5 12 2 11
+24V 1 1 6 11 3 10
L1SL102 L1SL102-U 2 2 7 10 4 9
L1SL102-L 3 3 8 9 5 8
9 8 6 7
SMP-03V-NC SMR-03V-N 10 7 7 6
+24V 1 1 11 6 8 5
L1MT104_2 L1MT104_2 2 2 12 5 9 4
P_GND 3 3 13 4 10 3
14 3 11 2
179228-3 SMR-03V-N SMP-03V-NC SMP-06V-NC SMR-06V-N 15 2 12 1
+5V 1 1 1 1 1 16 1
L1DT106 L1DT106 2 2 2 2 2
GND 3 3 3 3 3
4 4
179228-3 5 5
+5V 1 6 6
L1DT111 L1DT111 2
GND 3

179228-3
+5V 1
1 L1DT115 L1DT115
GND
2
3
4
3
2
1

4
3
2
1
4
3
2
1

1 GND +5V +5V


+DF11-4DP-SP1(05)

+DF11-4DP-SP1(05)
DF11-4DS-2C

DF11-4DS-2C
HRS

+DF11-4DP-SP1(05)
HRS

DF11-4DS-2C
HRS

MX-LC13 ELECTRICAL SECTION 8 - 7


TopPage
1 : ‘13/Dec

1CS UN

SMP-18V-NC SMR-18V-N CN-I B28B-PHDSS-B +24V


1 1 1 GND PS2RXEF135
2 2 2 GND
3 3 3 +24V_PS2
4 4 4 L1DT108_R
5 5 5 L1MT101-D
6 6 6 L1DD002_R L1DD002_R
7 7 7 L1DT116_R L1DT116_R
8 8 8 GND
9 9 9 GND
10 10 10 +24V_PS2
11 11 11 L1DT101_R L1DT101_R
12 12 12 GND
13 13 13 GND
14 14 14 L1MT101-U
15 15 15 +5VR
16 16 16 GND
17 17 17 L1DT107
18 18 18 +5V
19 GND
20 L1DT104
21 +24V
22 L1MT104_1
23 P_GND
24 +5V
25 L1DT110
26 GND
27 +5V
28 L1DA104

CN-J B22B-PHDSS-B
1 GND
2 L1DA103
3 +5VR
4 L1LD101
5 L1DT109
6 GND
7 +5V
8 L1DT105
9 GND
10 +24V_F5 +24V_F5
11 L1SL102-U
12 L1SL102-L
13 +24V
14 L1MT104_2
15 P_GND
16 GND
17 L1DT106
18 +5V
19 +5V
20 N.C.
21 GND
22 N.C.
SMP-10V-NC SMR-10V-N
1 1
2 2
3 3
4 4 CN-K B36B-PNDZS-1
5 5 1 GND
6 6 2 N.C.
7 7 3 GND
8 8 4 L1DT119
9 9 5 GND
10 10 6 L1DT121
7 +5V
8 +5V
9 +5V
10 GND
11 L1DT112
12 GND
13 L1DT113
14 GND
SMP-07V-NC SMR-07V-N 15 L1DT114
1 1 16 GND
2
3
2
3
17
18
L1DT115
GND
1
4 4 19 L1DT117
5
6
5
6
20
21
+5V
+5V
1
7 7 22 +5V
23 +5V
24 +5V
25 GND
26 L1DT111
27 GND
28 L1DT120
29 +5V
30 L1DT122
31 +5V
32 L1DT123
33 +5V
34 +5V
35 GND
36 GND

LCT MAIN PWB

MX-LC13 ELECTRICAL SECTION 8 - 8


TopPage
1 : ‘13/Dec

2CS UN
HRS HRS
DF11-6DS-2C DF11-6DS-2C
+DF11-6DP-SP1(05) +DF11-6DP-SP1(05)

+5V GND
6 5 4 3 2 1 6 5 4 3 2 1
ELR-03V ELP-03V
L1MT201-D 1 1
L1MT201
L1MT201-U 3 3

PS-187-3V
+24V 1
L1DT208
L1DT208 3

PHR-3
+5VR 1
L1DT207 GND 2
L1DT207 3

SMR-03V-N SMP-03V-NC
+5V 1 1
L1DT204 GND 2 2
L1DT204 3 3

SMP-03V-NC SMR-03V-N
+24V 1 1
L1MT204_1 L1MT204_1 2 2
P_GND 3 3

179228-3
+5V 1
L1DT212 L1DT212 2
GND 3

179228-3
+5V 1
L 1 DT2 1 3 L1DT213 2
GND 3

179228-3
+5V 1
L1DT214 L1DT214 2
GND 3

HRS HRS
DF11-6DS-2C DF11-6DS-2C
+DF11-6DP-SP1(05) +DF11-6DP-SP1(05)

+5V GND
6 5 4 3 2 1 6 5 4 3 2 1

BU10P-TR-P-H
PHR-4 SMR-04V-N SMP-04V-NC PHNR-10-H PHNR-10-H
+5VR 1 1 1 1 10
L TL D2 0 1 LTLD201 2 2 2 2 9
L1DT209 L1DT209 3 3 3 3 8
GND 4 4 4 4 7
5 6
179228-3 6 5
+5V 1 7 4
L1DT210 L1DT210 2 8 3
GND3 9 2
BU16P-TR-P-H 10 1
179228-3 PHNR-16-H PHNR-16-H
+5V 1 1 16
L 1 DT2 0 5 L1DT205 2 2 15 BU12P-TR-P-H
GND 3 3 14 PHNR-12-H PHNR-12-H
4 13 1 12
SMR-03V-N SMP-03V-NC 5 12 2 11
+24V 1 1 6 11 3 10
L1SL202 L1SL202-U 2 2 7 10 4 9
L1SL202-L 3 3 8 9 5 8
9 8 6 7
SMP-03V-NC SMR-03V-N 10 7 7 6
+24V 1 1 11 6 8 5
L1MT204_2 L1MT204_2 2 2 12 5 9 4
P_GND 3 3 13 4 10 3
14 3 11 2
179228-3 SMR-03V-N SMP-03V-NC SMP-06V-NC SMR-06V-N 15 2 12 1
+5V 1 1 1 1 1 16 1
L1DT206 L1DT206 2 2 2 2 2
GND 3 3 3 3 3
4 4
179228-3 5 5
+5V 1 6 6
L1DT211 L1DT211 2
GND 3

179228-3
+5V 1
1 L1DT215 L1DT215
GND
2
3

1
4
3
2
1

4
3
2
1
4
3
2
1

GND +5V +5V


+DF11-4DP-SP1(05)

+DF11-4DP-SP1(05)
DF11-4DS-2C

DF11-4DS-2C
HRS

+DF11-4DP-SP1(05)
HRS

DF11-4DS-2C
HRS

MX-LC13 ELECTRICAL SECTION 8 - 9


TopPage
1 : ‘13/Dec

2CS UN

SMP-18V-NC SMR-18V-N CN-Q B28B-PHDSS-B +24V


1 1 1 GND PS1RXEF135
2 2 2 GND
3 3 3 +24V_PS1
4 4 4 L1DT208_R
5 5 5 L1MT201-D
6 6 6 L1DD002_R L1DD002_R
7 7 7 L1DT216_R L1DT216_R
8 8 8 GND
9 9 9 GND
10 10 10 +24V_PS1
11 11 11 L1DT201_R L1DT201_R
12 12 12 GND
13 13 13 GND
14 14 14 L1MT201-U
15 15 15 +5VR
16 16 16 GND
17 17 17 L1DT207
18 18 18 +5V
19 GND
20 L1DT204
21 +24V
22 L1MT204_1
23 P_GND
24 +5V
25 L1DT210
26 GND
27 +5V
28 L1DA204

CN-P B22B-PHDSS-B
1 GND
2 L1DA203
3 +5VR
4 LTLD201
5 L1DT209
6 GND
7 +5V
8 L1DT205
9 GND
10 +24V_F5 +24V_F5
11 L1SL202-U
12 L1SL202-L
13 +24V
14 L1MT204_2
15 P_GND
16 GND
17 L1DT206
18 +5V
19 +5V
20 N.C.
21 GND
22 N.C.
SMP-10V-NC SMR-10V-N
1 1
2 2
3 3
4 4 CN-O B36B-PNDZS-1
5 5 1 GND
6 6 2 N.C.
7 7 3 GND
8 8 4 L1DT219
9 9 5 GND
10 10 6 L1DT221
7 +5V
8 +5V
9 +5V
10 GND
11 L1DT212
12 GND
13 L1DT213
14 GND
SMP-07V-NC SMR-07V-N 15 L1DT214
1 1 16 GND
2
3
2
3
17
18
L1DT215
GND
1
4 4 19 L1DT217
5
6
5
6
20
21
+5V
+5V
1
7 7 22 +5V
23 +5V
24 +5V
25 GND
26 L1DT211
27 GND
28 L1DT220
29 +5V
30 L1DT222
31 +5V
32 L1DT223
33 +5V
34 +5V
35 GND
36 GND

LCT MAIN PWB

MX-LC13 ELECTRICAL SECTION 8 - 10


LEAD-FREE SOLDER
The PWB’s of this model employs lead-free solder. The “LF” marks indicated on the PWB’s and the Service Manual mean “Lead-Free” solder.
The alphabet following the LF mark shows the kind of lead-free solder.

Example:

<Solder composition code of lead-free solder>

Solder composition Solder composition Solder composition code


code (Refer to the Sn-Ag-Cu a
Lead-Free table at the right.)
Sn-Ag-Bi
b
Sn-Ag-Bi-Cu
Sn-Zn-Bi z
5mm
a Sn-In-Ag-Bi
Sn-Cu-Ni
Sn-Ag-Sb
i
n
s
Bi-Sn-Ag-P p
Bi-Sn-Ag

(1) NOTE FOR THE USE OF LEAD-FREE SOLDER THREAD


When repairing a lead-free solder PWB, use lead-free solder thread.
Never use conventional lead solder thread, which may cause a breakdown or an accident.
Since the melting-point of lead-free solder thread is about 40°C higher than that of conventional lead solder thread, the use of the
exclusive-use soldering iron is recommended.

(2) NOTE FOR SOLDERING WORK


Since the melting-point of lead-freeCOPYRIGHT © XXXX
solder is about 220°C, which BYSHARP
is about CORPORATION
40°C higher than that of conventional lead solder, and its soldering
capacity is inferior to conventional one, it is apt to keep the soldering iron in contact with the PWB for longer time. This may cause land
separation or may exceed the heat-resistive temperature ALLofRIGHTS
components. RESERVED.
Use enough care to separate the soldering iron from the PWB when
completion of soldering is confirmed.
Since lead-free solder includes a greater quantity of tin, the iron tip may corrode easily. Turn ON/OFF the soldering iron power frequently.
If different-kind solder remains on the soldering iron tip, it is melted together with lead-free solder. To avoid this, clean the soldering iron
tip after completion of soldering work. No part of this publication may be reproduced,
stored in a retrieval system, or transmitted in
If the soldering iron tip is discolored black during soldering work, clean and file the tip with steel wool or a fine filer.
any form or by any means, electronic, mechanical,
photocopying, recording, or otherwise, without
prior written permission of the publisher.
CAUTION FOR BATTERY REPLACEMENT
(Danish) ADVARSEL !
Lithiumbatteri – Eksplosionsfare ved fejlagtig håndtering.
Udskiftning må kun ske med batteri
af samme fabrikat og type.
Levér det brugte batteri tilbage til leverandoren.
(English) Caution !
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type
recommended by the manufacturer.
Dispose of used batteries according to manufacturer’s instructions.
(Finnish) VAROITUS
Paristo voi räjähtää, jos se on virheellisesti asennettu.
Vaihda paristo ainoastaan laitevalmistajan suosittelemaan
tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden
mukaisesti.
(French) ATTENTION
Il y a danger d’explosion s’ il y a remplacement incorrect
de la batterie. Remplacer uniquement avec une batterie du
même type ou d’un type équivalent recommandé par
le constructeur.
Mettre au rebut les batteries usagées conformément aux
instructions du fabricant.
(Swedish) VARNING
Explosionsfara vid felaktigt batteribyte.
Använd samma batterityp eller en ekvivalent
typ som rekommenderas av apparattillverkaren.
Kassera använt batteri enligt fabrikantens
instruktion.
(German) Achtung
Explosionsgefahr bei Verwendung inkorrekter Batterien.
Als Ersatzbatterien dürfen nur Batterien vom gleichen Typ oder
vom Hersteller empfohlene Batterien verwendet werden.
Entsorgung der gebrauchten Batterien nur nach den vom
Hersteller angegebenen Anweisungen.

CAUTION FOR BATTERY DISPOSAL


(For USA, CANADA)
“BATTERY DISPOSAL”
THIS PRODUCT CONTAINS A LITHIUM PRIMARY
(MANGANESS DIOXIDE) MEMORY BACK-UP BATTERY
THAT MUST BE DISPOSED OF PROPERLY. REMOVE THE
BATTERY FROM THE PRODUCT AND CONTACT YOUR
LOCAL ENVIRONMENTAL AGENCIES FOR INFORMATION
ON RECYCLING AND DISPOSAL OPTIONS.

“TRAITEMENT DES PILES USAGÉES”


CE PRODUIT CONTIENT UNE PILE DE SAUVEGARDE DE
MÉMOIRE LITHIUM PRIMAIRE (DIOXYDE DE MANGANÈSE)
QUI DOIT ÊTRE TRAITÉE CORRECTEMENT. ENLEVEZ LA
PILE DU PRODUIT ET PRENEZ CONTACT AVEC VOTRE
AGENCE ENVIRONNEMENTALE LOCALE POUR DES
INFORMATIONS SUR LES MÉTHODES DE RECYCLAGE ET
DE TRAITEMENT.
COPYRIGHT © 2014 BY SHARP CORPORATION
All rights reserved.
Produced in Japan for electronic Distribution
No part of this publication may be reproduced,
stored in a retrieval system, or transmitted,
in any form or by any means,
electronic; mechanical; photocopying; recording or otherwise
without prior written permission of the publisher.

Trademark acknowledgements
• Microsoft®, Windows®, Windows® 98, Windows® Me, Windows NT® 4.0,
Windows® 2000, Windows® XP, Windows® Vista, Windows® 7,
Windows® Server 2003, Windows® Server 2008 and Internet Explorer®
are registered trademarks or trademarks of Microsoft Corporation in the U.S.A.
and other countries.
• PostScript is a registered trademark of Adobe Systems Incorporated.
• Macintosh, Mac OS, AppleTalk, EtherTalk, Laser Writer, and Safari are registered
trademarks or trademarks of Apple Inc.
• IBM, PC/AT, and Power PC are trademarks of International Business Machines
Corporation.
• Acrobat® Reader Copyright® Adobe Systems Incorporated. All rights reserved.
Adobe, the Adobe logo, Acrobat, and the Acrobat logo are trademarks of Adobe
Systems Incorporated.
• PCL is a registered trademark of the Hewlett-Packard Company.
• Sharpdesk is a trademark of Sharp Corporation.
• All other trademarks and copyrights are the property of their respective owners.

SHARP CORPORATION
Business Solutions CS Promotion Center II

First Edition: April 2012


Latest Edition: July 2014

You might also like