Professional Documents
Culture Documents
Hi ROM Instruction Manual (29x 140611)
Hi ROM Instruction Manual (29x 140611)
Hi-ROM
FANUC PMC ROM Programmer
Instruction Manual
영일제어기술(YOUNG IL Automation)
- 1 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
Table of Contents
1. General
1.1 Opening . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.2 Concept . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.3 Applicable CNC and PMC list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2. Install Software
2.1 Install USB drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.2 Install Hi-ROM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3. Quick View
3.1 Start program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.2 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.3 EP-ROM Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.4 EP-ROM Buffer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.5 File Open . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.6 File Save . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.7 PMC Select . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.8 ROM Specification change . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.9 Upload/Download . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.10 Display ladder form in 3/6 series . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.11 SUB49 editor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.12 FAPT LADDER execution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.13 Add Symbol & Comment files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.14 Program information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.15 Auto Save . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4. Application
4.1 Modify the 0-A Series PMC
4.1.1 Read ROM data from FAPT LADDER . . . . . . . . . . . . . . . . . . . . . . 16
4.1.2 Write FAPT LADDDER data to ROM . . . . . . . . . . . . . . . . . . . . . . 19
4.1.3 download to PMC-L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4.1.4 ROM Location within the 0-A Series . . . . . . . . . . . . . . . . . . . . . . 23
4.2 Modify the 0-B,C Series PMC
4.2.1 Read ROM data from FAPT LADDER . . . . . . . . . . . . . . . . . . . . . . 24
4.2.2 Write FAPT LADDDER data to ROM . . . . . . . . . . . . . . . . . . . . . . 26
4.2.3 download to PMC-L of 0-B Series . . . . . . . . . . . . . . . . . . . . . . . 29
4.2.4 download to PMC-L of 0-C Series . . . . . . . . . . . . . . . . . . . . . . . 30
4.2.5 download to PMC-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
- 2 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
Has been prepared on the basis of the (program displayed at the bottom, on the left
screen) Hi-ROM Control Software Ver2.8x, In earlier versions, this manual, that there is a
difference with the contents of this document I will inform you.
- 3 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
1. General
1.1 Opening
This device is a EP-ROM TYPE PMC-only read/writer of FANUC, its features are as
follows.
1.2 Concept
- 4 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
Explanation of symbol
O : Possible
@ : Processing development
X : Impossible
- : No function
ROM->FLAD : Create FAPT-LADDER file from ROM file
FLAD->ROM : Create ROM file from FAPT-LADDER file
CNC->ROM : Up load from PMC using RS-232 cable and create ROM file
ROM->CNC : download to PMC using RS-232 cable from ROM file
- 5 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
2. Install software
When run the "Setup.exe" in the installation folder, the installation will be done
automatically.
During installation, please install without changing the default settings
After installation, please restart Windows.
- 6 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
3. Quick view
The software version is displayed in the lower-left program. If a state in which the
hardware device is connected, it is displayed in the version of the hardware, if the
connection is bad, the message "not connected" is displayed.
- 7 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
3.2 Configuration
1) PMC Baudrate
It is possible to set the transfer rate of up / downloading in the EP-ROM Buffer and
PMC
2) Language
Can use the three languages.
3) PMC-N
Can set the download mode of PMC-N of 15Series.
Title Mode : Can download the immediately(9600BPS) PMC. Pascal data will not be
downloaded.
RomCas Mode : It is slow download speed(4800BPS) compared to the Title Mode. You
can also download the data that contains the Pascal.
4) PMC-I
Among the data that you created in FAPT LADDER the case of PMC-I, allows you to
determine if you want to apply the I / O MODULE related data. For more information,
please refer to Section 4.6.5.
5) PMC-I
Among the data that you created in FAPT LADDER the case of PMC-I, allows you to
determine if you want to apply the I / O MODULE related data. For more information,
please refer to Section 4.6.5.
- 8 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
8) FLADDER Location
Can specify the location of the executable file for DOS FAPT LADDER. Click the expand
icon, if you move to the folder that contains the "FLADDER.EXE" file, you have selected
or any executable file in the folder, the path is stored.
Blank check : Make sure that the EP-ROM have been removed
successfully
Program : Will be recorded in the EP-ROM contents of the
EP-ROM Buffer
Verify : Compare the contents of EP-ROM with the contents
of the EP-ROM Buffer
Read : Read the EP-ROM Buffer the contents of the
EP-ROM.
Auto : Run in a row "Blank check"->"Program"->"Verify"
EP-ROM Buffer is a temporary storage location that serves as a relay EP-ROM and FAPT
LADDER file, the PMC between the FAPT LADDER file.
- 9 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
It generates a ROM file in EP-ROM Bufferf you have opened the file.
- 10 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
- 11 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
Can select the PMC. At the bottom of the window, you can see the ROM TYPE and
PMC TYPE that is currently selected.
FANUC-PMC
Can open the converted file when you save the file to select when you are working
with FANUC PMC file, or open the file and save it.
EP-ROM
It is used to read and write the ROM as ROM-Writer general, conversion of files will
not occur.
- 12 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
3.9 Upload/download
It is used when you want to send the data to the PMC by using the Serial Port of
Hi-ROM, it receives.
download : Can send to PMC data of EP-ROM Buffer.
Up load : Can forward to the EP-ROM Buffer the data of PMC.
- 13 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
- 14 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
Can add a comment of the symbols of the LADDER program there is no comment or
symbol.
Comments and symbols, allows you to use the file you previously created, you create
arbitrarily.
Can view the program information. If you click on the version information, you can view
the contents of the improvement of each version.
It will be automatically saved to the file after the read ROM, or upload the Hi-ROM.
The storage location is the folder Hi-ROM is installed c:\Programfiles\ Hi-ROM, type
the date that you have read, time, the PMC, the file name will take the file name for
each type of ROM.
- 15 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
4. Application
4.1 Modify the 0-A Series PMC
Note)It can not be used binary command(SUBB, ADDB, CODB, etc.) on O-A PMC-L.
1) Please select the PMC in the selection of PMC. In the case of PMC-L, please choose
011,012 (27C64) If you are a PMC-M to 011,012 (27C256). The following description
based on the PMC-M.
2) Please attach to the EP-ROM socket of Hi-ROM one of the PMC ROM. (Please note
insertion direction) The order does not matter that some ROM is listed above 011,012
- 16 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
Select the number of ROM that is mounted on the EP-ROM the current socket, when
you click Start, you can read the EP-ROM Buffer content of EP-ROM. The last address is
0x7FFF if is a PMC-M, 0x1FFF If is a PMC-L. Once loaded all, is inserted into the socket
of the ROM number of other, after changing the ROM number, and then start again.
This is a state in which the contents of the PMC ROM is loaded all the EP-ROM Buffer
now.
Make sure that it is the #EX on the type of file, specify the file name and path.Save
the file length of the file name, including the path or is 36 or more characters(The path
of FAPT LADDER path below, the length minus the FAPT LADDER path), the path or file
name of 8 characters or more is contained are possible. However, please note that does
not recognize FAPT LADDER.
5) Dialog box that asks you whether you want to save the source will be displayed.
- 17 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
The original file because it is required when writing ROM of LADDER After making the
changes is to save separately. The PMC was can be modified in FAPT LADDER existing,
PASCAL is included in the 15-Series and PMC does not require text but as ,0-A Series,
has been working with FANUC PG existing The PMC, data is generated based on the
source.
The original file, has been designated a "ROM" file types. Can be used even if the user
specified in the file format of your choice. And then save the file and then click Open.
The file name will be called in the file name that was used to save, having to type the
file name each time is eliminated. Click the F1 [EXEC], when you run the Decompile, file
of FAPT LADDER for is created in the location where you saved the file from Hi-ROM.
7) Edit the LADDER by calling FAPT LADDER by clicking on the icon FLADDER. At that
time, you may have to work by switching to full-screen mode ALT+ENTER key normal
screen will appear only in full-screen mode always.
- 18 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
1) Editing in FAPT LADDER When you are finished, save the file, click the F3 [compile]
from the main menu, and then run the compile.
2) Click after it was confirmed that the compile has completed successfully, click Open,
from Hi-ROM, specify the files that are compile, and then click the "Open".
3) Specify the file from which to select "Yes" dialog box looking for the original file
appears, you saved in "Save" before.
- 19 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
4) Contents of the ROM and the original contents of the LADDER which has been
modified together, normal data was generated in EP-ROM Buffer.
5) Please attach the ROM socket of Hi-ROM the EP-ROM erased. Please note insertion
direction.
6) Please run the "Blank check" of EP-ROM menu to make sure that the ROM has been
erased.
- 20 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
If the ROM is not being erased, an error message is displayed along with the address
of the location.
7) Confirmation of "Blank check" is complete with no errors, in order to write the ROM
"Write".
After selecting the ROM number one, clicking the "start", to perform the write. Writing
of one of the ROM is complete without errors, please give it with a ROM number in
the ROM of the EP-ROM socket. After you have installed the ROM of another number
again, after changing the ROM number, when you click "Start", to perform the write.
When burning is complete, please give it with a ROM number again.
8) Please check the behavior by mounting a ROM that write completion in EP-ROM
socket of CNC.
Run until "Write FAPT LADDDER data to ROM" to chapter 4, to create the EP-ROM
Buffer the data of EP-ROM. 0-A can be used to download only PMC-L.
1) Please attach an SRAM (6264) to PMC-ROM(011,012) socket of CNC. Please note
insertion direction.
- 21 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
3) It becomes the PMC Download standby state is set to ON, the power to the CNC.
If you run the download by clicking on the "Start", the contents of the EP-ROM Buffer
is downloaded to the PMC.
5) And OFF, data that has been downloaded it will erase the power supply, you will
need to perform the download again.
- 22 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
1) PMC-L
It is located in the top of the main board, it is as the next image.
2) PMC-M
It is mounted PMC-M card (A16B-1210-0810) on, it is as the next image.
- 23 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
2) Please attach to the EP-ROM socket of Hi-ROM one of the PMC ROM. (Please note
insertion direction) The order does not matter that some ROM is listed above 0F1,0F2
- 24 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
Select the number of ROM that is mounted on the EP-ROM the current socket, when
you click Start, you can read the EP-ROM Buffer content of EP-ROM. The last address is
0x7FFF. Once loaded all, is inserted into the socket of the ROM number of other, after
changing the ROM number, and then start again. This is a state in which the contents
of the PMC ROM is loaded all the EP-ROM Buffer now.
Make sure that it is the #EX on the type of file, specify the file name and path.Save
the file length of the file name, including the path or is 36 or more characters(The path
of FAPT LADDER path below, the length minus the FAPT LADDER path), the path or file
name of 8 characters or more is contained are possible. However, please note that does
not recognize FAPT LADDER.
- 25 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
The file name will be called in the file name that was used to save, having to type the
file name each time is eliminated. Click the F1 [EXEC], when you run the Decompile, file
of FAPT LADDER for is created in the location where you saved the file from Hi-ROM.
6) Edit the LADDER by calling FAPT LADDER by clicking on the icon FLADDER. At that
time, you may have to work by switching to full-screen mode ALT+ENTER key normal
screen will appear only in full-screen mode always.
1) Editing in FAPT LADDER When you are finished, save the file, click the F3 [compile]
from the main menu, and then run the compile.
- 26 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
2) Click after it was confirmed that the compile has completed successfully, click Open,
from Hi-ROM, specify the files that are compile, and then click the "Open".
- 27 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
4) Please attach the ROM socket of Hi-ROM the EP-ROM erased. Please note insertion
direction.
5) Please run the "Blank check" of EP-ROM menu to make sure that the ROM has been
erased.
If the ROM is not being erased, an error message is displayed along with the address
of the location.
6) Confirmation of "Blank check" is complete with no errors, in order to write the ROM
"Write".
After selecting the ROM number one, clicking the "start", to perform the write. Writing
of one of the ROM is complete without errors, please give it with a ROM number in
the ROM of the EP-ROM socket. After you have installed the ROM of another number
again, after changing the ROM number, when you click "Start", to perform the write.
When burning is complete, please give it with a ROM number again.
- 28 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
Run until "Write FAPT LADDDER data to ROM" to chapter 3, to create the EP-ROM
Buffer the data of EP-ROM.
1) Please attach an SRAM (62256) to PMC-ROM(0E1,0E2) socket of CNC. Please note
insertion direction.
3) It becomes the PMC Download standby state is set to ON, the power to the CNC.
- 29 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
If you run the download by clicking on the "Start", the contents of the EP-ROM Buffer
is downloaded to the PMC.
5) And OFF, data that has been downloaded it will erase the power supply, you will
need to perform the download again.
1) Run until "Write FAPT LADDDER data to ROM" to chapter 3, to create the EP-ROM
Buffer the data of EP-ROM.
2) Please make sure that PARAMETER #71.6(PMC RAM MODE) of CNC is 0 . For 1,
because it means that it was a RAM operating mode of the existing, if the source file
does not exist, it should be noted.
4) If you select "(1) LOAD FROM I / O" PMC LOAD SELECT screen appears, it becomes
standby PMC Download
- 30 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
If you run the download by clicking on the "Start", the contents of the EP-ROM Buffer
is downloaded to the PMC.
- 31 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
4) Run until "Write FAPT LADDDER data to ROM" to chapter 3, to create the EP-ROM
Buffer the data of EP-ROM.
5) It becomes the PMC Download standby state is set to ON, the power to the CNC.
7) And OFF, data that has been downloaded it will erase the power supply, you will
need to perform the download again.
- 32 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
In the case of PMC-L of RAM during operation, editing menu appears after you set to
0 (RAM operation) bit 6 of parameter # 71. In the case of PMC-M, Please note that the
power is turned off, the edited contents is deleted.
1) After turning OFF the power of CNC, to install the editing card(A02B-0098-C199,
A20B-2000-0150) into the card slot of editing.
- 33 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
7) Select the PMC from Hi-ROM, by running the upload, and click "Start".
- 34 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
ADDRESS becomes 007FFF, MODE will change to VERIFY, at this time, after you press
the [CANCEL] key, then press the [0E2](0F2) key.
MODE Is displayed in the PROGRAM again, ADDRESS is increased, the 0E2(0F2) data is
transferred to the Hi-ROM.
ADDRESS becomes 007FFF again, MODE will change to VERIFY, at this time, press the
[CANCEL] key, to complete the transfer.
8) Can either save it in a file on the Hi-ROM, to write directly in the ROM.
- 35 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
PMC-N is adapted to form CASSETTE. Then, the Hi-ROM, 4 types A, B, C, and D can be
used.
1) Please select the PMC in the selection of PMC. The following description based on
the CASSETTE-B.
2) Connect to the PMC-N conversion board CASSETTE, and then attached to the
EP-ROM socket of Hi-ROM.
- 36 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
When you click Start Make sure that the "cassette" is selected, you can read the
EP-ROM Buffer the contents of the EP-ROM. If you read in the EP-ROM without
cassette, Select the number of ROM that is mounted on the EP-ROM the current
socket, when you click Start, you can read the EP-ROM Buffer content of EP-ROM. The
last address is 0x1FFFF. Once loaded all, is inserted into the socket of the ROM number
of other, after changing the ROM number, and then start again. This is a state in which
the contents of the PMC ROM is loaded all the EP-ROM Buffer now.
Make sure that it is the #EX on the type of file, specify the file name and path.Save
the file length of the file name, including the path or is 36 or more characters(The path
of FAPT LADDER path below, the length minus the FAPT LADDER path), the path or file
name of 8 characters or more is contained are possible. However, please note that does
not recognize FAPT LADDER.
5) If PASCAL is included, a dialog box that asks you whether you want to save the
source will be displayed.
- 37 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
The original file because it is required when burning ROM of LADDER After making the
changes is to save separately. The PMC was can be modified in FAPT LADDER existing,
PASCAL is included in the 15-Series and PMC does not require text but as ,0-A Series,
has been working with FANUC PG existing The PMC, data is generated based on the
source.
The original file, has been designated a "ROM" file types. Can be used even if the user
specified in the file format of your choice. And then save the file and then click Open.
The file name will be called in the file name that was used to save, having to type the
file name each time is eliminated. Click the F1 [EXEC], when you run the Decompile, file
of FAPT LADDER for is created in the location where you saved the file from Hi-ROM.
7) Edit the LADDER by calling FAPT LADDER by clicking on the icon FLADDER. At that
time, you may have to work by switching to full-screen mode ALT+ENTER key normal
screen will appear only in full-screen mode always.
- 38 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
1) Editing in FAPT LADDER When you are finished, save the file, click the F3 [compile]
from the main menu, and then run the compile.
2) Click after it was confirmed that the compile has completed successfully, click Open,
from Hi-ROM, specify the files that are compile, and then click the "Open".
3) If PASCAL is included, Specify the file from which to select "Yes" dialog box looking
for the original file appears, you saved in "Save" before.
- 39 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
4) Contents of the ROM and the original contents of the LADDER which has been
modified together, normal data was generated in EP-ROM Buffer.
5) Set exchange PCB stuck cassette in ROM socket for write ROM.
6) Please run the "Blank check" of EP-ROM menu to make sure that the ROM has been
erased.
Make sure that the "cassette" is selected, and then click Start. Without CASSETTE, if you
want to use the ROM of the individual, select the "ROM", and then click Start
If the ROM is not being erased, an error message is displayed along with the address
of the location.
- 40 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
7) Confirmation of "Blank check" is complete with no errors, in order to write the ROM
"Write".
If you are using a cassette, select the "Cassette", and then click Start to run the writing.
If you are using a ROM of individual, after selecting the ROM number one, clicking the
"start", to perform the write. Writing of one of the ROM is complete without errors,
please give it with a ROM number in the ROM of the EP-ROM socket. After you have
installed the ROM of another number again, after changing the ROM number, when
you click "Start", to perform the write. When burning is complete, please give it with a
ROM number again.
8) Please check the behavior by mounting the write completion to CASSETTE cassette
connector of CNC
- 41 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
Run until "Write FAPT LADDDER data to ROM" to chapter 4, to create the EP-ROM
Buffer the data of EP-ROM.
PMC-N can be changed in two "Config", there is a method of download.
- 42 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
3) Check the "Title Mode" from "Config" in Hi-ROM, it is set to 9600 baud PMC.
If you run the download by clicking on the "Start", the contents of the EP-ROM Buffer
is downloaded to the PMC.
- 43 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
4) Check the "ROMCAS Mode" from "Config" in Hi-ROM, it is set to 4800 baud PMC.
If you run by clicking on the "Start", it will be in the state of waiting for download.
6) Contents of the EP-ROM Buffer of Hi-ROM will be sent to the PMC Press the
CNC/PMC->ETC->I/O->ROMCAS->READ, communication is started . Time of 10 seconds
or more that it takes a while to start the transfer, you must wait without canceling.
- 44 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
If you or was driving in the RAM board, you have changed the PMC from the CNC,
you will need to upload the data to write to the CASSETTE.
4) Check the "ROMCAS Mode" from "Config" in Hi-ROM, it is set to 4800 baud PMC.
If you run by clicking on the "Start", it will be in the state of waiting for up load.
7) When the transfer is complete, was mounted to the Hi-ROM cassette erased, and
then write in the ROM.
- 45 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
1) Please select the PMC in the selection of PMC. The PMC can be used for each CNC
for each, there are 3 types.
Make sure that you click the SYSTEM->PMC->PMCDGN, PMC some are used.
- 46 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
Select the PMC in PMC Select. The following description based on the RB3.
2) Please attach to the EP-ROM socket of Hi-ROM PMC ROM. (Please note insertion
direction)
When you click Start, you can read the EP-ROM Buffer content of EP-ROM. The last
address is 0x1FFFF.
- 47 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
Make sure that it is the #EX on the type of file, specify the file name and path.Save
the file length of the file name, including the path or is 36 or more characters(The path
of FAPT LADDER path below, the length minus the FAPT LADDER path), the path or file
name of 8 characters or more is contained are possible. However, please note that does
not recognize FAPT LADDER.
If the PMC-Rx PMC, it can not be called in the parameter file name must be entered
each time a file name. Click the F1 [EXEC], when you run the Decompile, file of FAPT
LADDER for is created in the location where you saved the file from Hi-ROM.
7) Edit the LADDER by calling FAPT LADDER by clicking on the icon FLADDER. At that
time, you may have to work by switching to full-screen mode ALT+ENTER key normal
screen will appear only in full-screen mode always.
- 48 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
2) Click after it was confirmed that the compile has completed successfully, click Open,
from Hi-ROM, specify the files that are compile, and then click the "Open".
- 49 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
4) Please attach the ROM socket of Hi-ROM the EP-ROM erased. Please note insertion
direction.
6) Please run the "Blank check" of EP-ROM menu to make sure that the ROM has been
erased.
If the ROM is not being erased, an error message is displayed along with the address
of the location.
- 50 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
7) Confirmation of "Blank check" is complete with no errors, in order to write the ROM
"Write".
8) Please check the behavior by mounting a ROM that write completion in EP-ROM
socket of CNC.
Communication port is set at screen by keying SYSTEM ->PMC -> (>) -> I/O ->
CHANNEL. When the communication port JD5A If this setting is 1, the case of 2, and a
communication port JD5B. Baud rate is set at screen by keying SYSTEM ->PMC -> (>)
-> I/O -> (>) SPEED.
- 51 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
3) In "Settings", set to be the same as the communication speed of the CNC PMC
communication speed.
Click the "Start", when you run the upload, the PMC data is sent to the EP-ROM Buffer
of Hi-ROM.
- 52 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
1) Please select the PMC in the selection of PMC. The PMC can be used for each CNC
for each, there are 2 types.
Make sure that you click the SYSTEM->PMC->PMCDGN, PMC some are used.
2) Select the PMC in PMC Select. The following description based on the PA1.
- 53 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
5) In "Settings", set to be the same as the communication speed of the CNC PMC
communication speed.
- 54 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
Click the "Start", when you run the upload, the PMC data is sent to the EP-ROM Buffer
of Hi-ROM.
Make sure that it is the #EX on the type of file, specify the file name and path.Save
the file length of the file name, including the path or is 36 or more characters(The path
of FAPT LADDER path below, the length minus the FAPT LADDER path), the path or file
name of 8 characters or more is contained are possible. However, please note that does
not recognize FAPT LADDER.
- 55 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
If the PMC-PAx PMC, it can not be called in the parameter file name must be entered
each time a file name. Click the F1 [EXEC], when you run the Decompile, file of FAPT
LADDER for is created in the location where you saved the file from Hi-ROM.
10) Edit the LADDER by calling FAPT LADDER by clicking on the icon FLADDER. At that
time, you may have to work by switching to full-screen mode ALT+ENTER key normal
screen will appear only in full-screen mode always.
1) Editing in FAPT LADDER When you are finished, save the file, click the F3 [compile]
from the main menu, and then run the compile.
- 56 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
2) Click after it was confirmed that the compile has completed successfully, click Open,
from Hi-ROM, specify the files that are compile, and then click the "Open".
- 57 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
6) In "Settings", set to be the same as the communication speed of the CNC PMC
communication speed.
If you run the download by clicking on the "Start", the contents of the EP-ROM Buffer
is downloaded to the PMC.
- 58 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
PMC-I is adapted to form CASSETTE. Then, the Hi-ROM, 4 types A and B can be used.
1) Please select the PMC in the selection of PMC. The following description based on
the CASSETTE-B.
2) Connect to the PMC-I conversion board CASSETTE, and then attached to the
EP-ROM socket of Hi-ROM.
- 59 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
It is necessary to use a substrate that is labeled "A/B" by all means to PMC-I converter
board, if there is any label, if there is no board, we will upgrade when you wear along
with the body.
When you click Start Make sure that the "cassette" is selected, you can read the
EP-ROM Buffer the contents of the EP-ROM. The last address is 0x1FFFF. This is a state
in which the contents of the PMC ROM is loaded all the EP-ROM Buffer now.
- 60 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
Make sure that it is the #EX on the type of file, specify the file name and path.Save
the file length of the file name, including the path or is 36 or more characters(The path
of FAPT LADDER path below, the length minus the FAPT LADDER path), the path or file
name of 8 characters or more is contained are possible. However, please note that does
not recognize FAPT LADDER.
For the FAPT LADDER, there is no menu PMC-I, it is converted to PMC-N during
storage, as a result, the window will be displayed.
5) Dialog box that asks you whether you want to save the source will be displayed.
The original file because it is required when burning ROM of LADDER After making the
changes is to save separately. The PMC was can be modified in FAPT LADDER existing,
PASCAL is included in the 15-Series and PMC does not require text but as ,0-A Series,
has been working with FANUC PG existing The PMC, data is generated based on the
source.
- 61 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
The original file, has been designated a "ROM" file types. Can be used even if the user
specified in the file format of your choice. And then save the file and then click Open.
6) Save is complete, "Decompiler" is run. The decision to run is set in "Config".
The file name will be called in the file name that was used to save, having to type the
file name each time is eliminated. Click the F1 [EXEC], when you run the Decompile, file
of FAPT LADDER for is created in the location where you saved the file from Hi-ROM.
7) Edit the LADDER by calling FAPT LADDER by clicking on the icon FLADDER. At that
time, you may have to work by switching to full-screen mode ALT+ENTER key normal
screen will appear only in full-screen mode always.
1) Editing in FAPT LADDER When you are finished, save the file, click the F3 [compile]
from the main menu, and then run the compile.
- 62 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
2) Click after it was confirmed that the compile has completed successfully, click Open,
from Hi-ROM, specify the files that are compile, and then click the "Open".
3) Specify the file from which to select "Yes" dialog box looking for the original file
appears, you saved in "Save" before.
- 63 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
5) Contents of the ROM and the original contents of the LADDER which has been
modified together, normal data was generated in EP-ROM Buffer.
5) Connect to PMC-I converter board the cassette that were erased for writing ROM,
and attached to the ROM socket of Hi-ROM.
6) Please run the "Blank check" of EP-ROM menu to make sure that the ROM has been
erased.
- 64 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
If the ROM is not being erased, an error message is displayed along with the address
of the location.
7) Confirmation of "Blank check" is complete with no errors, in order to write the ROM
"Write".
8) Please check the behavior by mounting the write completion to CASSETTE cassette
connector of CNC
- 65 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
If you run by clicking on the "Start", it will be in the state of waiting for download.
- 66 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
6) Contents of the EP-ROM Buffer of Hi-ROM will be sent to the PMC Press the
CNC/PMC->ETC->I/O->ROMCAS->READ, communication is started . Time of 10 seconds
or more that it takes a while to start the transfer, you must wait without canceling.
After changing the PMC from the CNC, you will need to upload the data to write to
the cassette.
If you run by clicking on the "Start", it will be in the state of waiting for upload.
6) When the transfer is complete, was mounted to the Hi-ROM cassette erased, and
then write in the ROM.
- 67 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
2) ADDRESS area
3) NET ERROR
The PMC-I, since it is a program written in FANUC PG, cause commands are not
allowed when using by converting the PMC-N are included. It must change the form
that can be recognized by FAPT LADDER by converting to mnemonic these commands.
Caution) ERROR NET, because in some cases NET two overlap, if the ERROR NET is
found, after it was confirmed by mnemonic always, you will need to change.
- 68 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
- 69 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
1) By running "Ladder 6", and then select the type of PC models in "PC Select". Model
of PC is changed, the data read of the existing one is initialized.
2) Select the ROM number in "ROM number", click the "Read", and load the ROM.
If that had been saved to a file in advance, and then select the file by clicking the
"File".
3) Run that the choice of data is complete, you want to convert. This brings up a
dialog to enter the file name to save comes out, file for Display is created in the file
specified here, file of mnemonics called file name + (Mnemonic) that you specify will
also be created.
(Example: When specifying Test.txt to the output file name Test(Mnenonic).txt )
*Auto address :This is a function for attaching the head (X,Y,F,G and R) address
automatically:
*Number of contact+coils a line : Select whether to output a plurality of elements on
one line. If there are elements in excess of this number, it will be
output in place of the next line.
- 70 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
- 71 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
- 72 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
2)Click the "Message 0" from Hi-ROM, and click the [Open] by clicking on the icon, and
then select the file of #LA saved.
File name and the current message index address is displayed at the bottom. If you
have more than one message block, go to the message you want to the left and right
arrow icon.
Create a message. Number of messages per block is 16 or fewer. The data must be
created in the form of message number, four-digit + message content. Even if you do
not put a space between the contents of the message and the message number, there
is blank space automatically when it is displayed on the CNC screen.
- 73 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
*Japanese notation
Recognition will be the Japanese, but it is displayed in three-digit number after the &
symbol notation is not in character.
If you change the number, contents will also be changed. Please refer to the
brochure of FANUC MTB The Japanese code of the number.
3) When you have finished editing, you can save it and then click the Save icon. When
saving, the original file is automatically saved in the backup file. (Example : TEST.#LA,
the backup file name source file name TEST(n).#LA n:1 ~ 65535)
- 74 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
4) When open the file in FAPT LADDER, data are sorted line size and the size of the
message is automatically determined.
- 75 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
Selection window LADDER file comes out, please select the #LA file.
Replace the comment file of the symbol that is stored in the pre-comment file of an
existing symbol.
This is as follows, comment file symbol per PMC can be used the user to arbitrarily
changed.
Decide on the basis of the PMC is currently set from Hi-ROM and should be applied
which files.
CAUTION) 15M or T, if the PASCAL data is included, please note that if you change the
symbol or comment, PMC is not working properly.
- 76 -
Hi-ROM Instruction Manual(29x-140611) YOUNG IL Automation
- 77 -