Length of pile Wave
Toe Speed** Shaft Cross-Section and Soil Changes (from
S. No. Pile No. from test level Pile Class
response test level)
(m) (m/sec)

27 March 2019
1.0
Final
18-13-133224/PIT-2
1. P-12 Evident 26.53 4000 Fairly uniform shaft. No sharp defined reflections. A

2. P-13 Evident 26.53 4000 Fairly uniform shaft. No sharp defined reflections. A

3. P-14 Evident 26.53 4000 Fairly uniform shaft. No sharp defined reflections. A
:

Fairly uniform shaft. No sharp defined reflections.


4. P-15 - 26.53 4000 A
However, no clear evident toe signal

5. P-16 Evident 26.53 4000 Fairly uniform shaft. No sharp defined reflections. A

6. P-17 Evident 26.53 4000 Fairly uniform shaft. No sharp defined reflections. A

Fairly uniform shaft. No sharp defined reflections.


7. P-18 - 27.53 4000 A
However, no clear evident toe signal

Notes: * Wave speed presented here are back calculated to match the pile toe as evident from the test result with pile length provided by the contractor. If the wave
speed is within the acceptable range (3800 m/s to 4200 m/s), the pile length is considered acceptable.

PILE INTEGRITY TEST RESULTS


PLATE 4a

JEC City Commercial Port Project (Offshore)


North Terminal rear crane beam pile
Jizan
Date:
Rev. No.:
Status:
Report No.:
Length of pile Wave
Toe Speed** Shaft Cross-Section and Soil Changes (from
S. No. Pile No. from test level Pile Class
response test level)
(m) (m/sec)

27 March 2019
1.0
Final
18-13-133224/PIT-2
8. P-19 Evident 27.53 4000 Fairly uniform shaft. No sharp defined reflections. A

Fairly uniform shaft. No sharp defined reflections.


9. P-20 - 26.53 4000 A
However, no clear evident toe signal

Fairly uniform shaft. No sharp defined reflections.


10. P-21 - 26.53 4000 A
However, no clear evident toe signal
:

Fairly uniform shaft. No sharp defined reflections.


11. P-22 - 26.53 4000 A
However, no clear evident toe signal

Fairly uniform shaft. No sharp defined reflections.


12. P-23 - 26.53 4000 A
However, no clear evident toe signal

13. P-24 Evident 26.53 4000 Fairly uniform shaft. No sharp defined reflections. A

Fairly uniform shaft. No sharp defined reflections.


14. P-25 - 26.53 4000 A
However, no clear evident toe signal

Notes: * Wave speed presented here are back calculated to match the pile toe as evident from the test result with pile length provided by the contractor. If the wave
speed is within the acceptable range (3800 m/s to 4200 m/s), the pile length is considered acceptable.

PILE INTEGRITY TEST RESULTS


PLATE 4b

JEC City Commercial Port Project (Offshore)


North Terminal rear crane beam pile
Jizan
Date:
Rev. No.:
Status:
Report No.:
Length of pile Wave
Toe Speed** Shaft Cross-Section and Soil Changes (from
S. No. Pile No. from test level Pile Class
response test level)
(m) (m/sec)

27 March 2019
1.0
Final
18-13-133224/PIT-2
Fairly uniform shaft. No sharp defined reflections.
15. P-26 - 26.53 4000 A
However, no clear evident toe signal

16. P-27 Evident 26.53 4000 Fairly uniform shaft. No sharp defined reflections. A

17. P-28 Evident 26.53 4000 Fairly uniform shaft. No sharp defined reflections. A
:

18. P-29 Evident 26.53 4000 Fairly uniform shaft. No sharp defined reflections. A

19. P-30 Evident 26.53 4000 Fairly uniform shaft. No sharp defined reflections. A

Notes: * Wave speed presented here are back calculated to match the pile toe as evident from the test result with pile length provided by the contractor. If the wave
speed is within the acceptable range (3800 m/s to 4200 m/s), the pile length is considered acceptable.

PILE INTEGRITY TEST RESULTS


PLATE 4c

JEC City Commercial Port Project (Offshore)


North Terminal rear crane beam pile
Jizan