Professional Documents
Culture Documents
Description
This is the list of fixed timers with a brief explanation and their values. A timer expiry
message appears in its own window, on the test set display. The user has no access to
these values and can not change them. None of the fixed timers are active when operating
mode is Test Mode.
Description Value
Timer Name
4 SACCH
multiframes. That
T100 RADIO- Detects the presence of the radio link by detecting
is 1.92 seconds if
LINK-TIMEOUT SACCH frames every 480 ms.
the SACCH is
completely absent.
T200 Data link Used for re-transmission on the data link. The
155 ms for FACCH
timer value varies depending on the message type.
T301 Alerting Timer used to limit the amount of time a user has
20 seconds
(ringing) timer to answer a call.
T3111 Channel
deactivation after Time the network waits after disconnecting the
500 ms
disconnection signalling link before deactivating the channel.
timer