Malfunctions, MID 128 Group 30: Electrical system

Checking the charge air


pressure sensor*
* Combined sensor, charge pressure and charge temperature.

Special tools: 9812519, 999 8534

1
NOTE! Turn the starter key to the stop position.

2
Remove the connector from the sensor. Connect
adapter cable 999 8534 between sensor and engine
control unit.

3
Turn the starter key to drive position.

4
Use multimeter 9812519 to do voltage measurement
against the engine control unit.

Measurement points Nominal value


2–4 U ≈ 1.2V*
* Note. At normal atmospheric pressure.
Output voltage, V

Component specification
Working range . 40–400 kPa (0.4–4.0 bar / 5.8-58 Psi)
Supply voltage .................................. 5.00 ±0.25 V DC

Nominal output voltage at 25 °C (77 °F) and supply


voltage 5.00 V DC:
0,5 V DC at .......................... 40 kPa (0.4 bar / 5.8 Psi)
4,5 V DC at ............................ 400 kPa (4 bar / 58 Psi)
Charge air pressure (absolute pressure), kPa

60