Capacity Factor Table, %

BATTERY INFORMATION BEI 150 deg C 180 deg C MEMORY PLT BATTERY LIFE ESTIMATION
Battery Type BEI Capacity 5.5 Ah 4.5 Ah MEMORY TELEMETRY TOOLS
Power Rating 5.5 Ampere Hrs Ambient 70 70 If sample rate <= 7 secs tool power is on all the time
Capacity Factor 100 % 50 deg C 80 80 Otherwise powered up for 4 secs per sample / reading.
Available power 5500 mAH 100 deg C 70 80 Real time clock power consumption 500 uA.
Self Drain per day 1.0 % 150 deg C 80 90

TOOL: MPL QPS CCL PRT ILS FDR PDC CWH PGR CFB / CFS FDD SPARE SPARE Total
CURRENT: 50 8 3 14 8 25 15 5 25 9 26 0 0 Current,mA
TOOLS USED: 1 1 1 1 0 1 0 1 1 1 0 0 0 139

TOOL INSTRUCTIONS Total Power Used Cumulative RESULTS: mAH %


Sample interval, Hrs Sample Rate, Secs No of readings Current mAH mAH Total Available 5500 100.0
14 10 5040 139.5 786.2 786 Total Used 3642 66.2
2 1 7200 139.5 279.0 1065 Self Drain 128 2.3
12 10 4320 139.5 674.6 1740
2 1 7200 139.5 279.0 2019 Total Left 1730 31.4
24 10 8640 139.5 1344.2 3363
2 1 7200 139.5 279.0 3642
3642 Instructions:
3642
3642 Enter Battery Information. Estimate capacity factor allowing for a safety margin.
3642 Capacity Factor is estimation of % of theoretical total power that is recoverable.
3642 Self drain is related to downhole temperature. For Lithium batteries it is low (assumed 1%).
3642 Enter Tool Type, Tool Current (from Sondex QC results sheet) and Tools Used in the PLT string.
Enter Tool Instructions: Consecutive Intervals in hours and Sample Rate in seconds.
Total length of program in hours: 56 Power Used: 3642 Rev 1.0 Feb 99

Remarks:

This spreadsheet is to be used as a guide only. As battery life is dependent upon so many variables, Sondex cannot be held liable for consequences resulting from it's use.