HEAT EXCHANGER SPECIFICATION SHEET Page 1

SI Units 940
Job No.
mm
Customer Reference No.
Address Proposal No.
Date Rev
Item No.
Size 940 x 7500 mm Type NEN Vertical Connected In 1 Parallel 1 Series
Surf/Unit (Gross/Eff) 370,51 / 364,24 m2 Shell/Unit 1 Surf/Shell (Gross/Eff) 370,51 / 364,24 m2
PERFORMANCE OF ONE UNIT
Fluid Allocation Shell Side Tube Side
Fluid Name Demi Water Alkaline Effluent
Fluid Quantity, Total kg/hr 398100 360000
Vapor (In/Out)
Liquid 398100 398100 360000 360000
Steam
Water 398100 398100 360000 360000
Noncondensables
Temperature (In/Out) C 25,00 55,00 85,00 52,00
Specific Gravity 0,9968 0,9853 0,9691 0,9866
Viscosity mN-s/m2 0,8899 0,5041 0,3335 0,5291
Molecular Weight, Vapor
Molecular Weight, Noncondensables
Specific Heat kJ/kg-C 4,2193 4,2265 4,2673 4,2248
Thermal Conductivity W/m-C 0,6079 0,6462 0,6704 0,6429
Latent Heat kJ/kg
Inlet Pressure kPa 800,00 500,00 7,5
Velocity m/s 0,72 1,24
Pressure Drop, Allow/Calc kPa 70 40 40 25
m
Fouling Resistance (min) m2-K/W 0,000070 0,000100
Heat Exchanged 14009 kW MTD (Corrected) 22,1 C
Transfer Rate, Service 1738,8 W/m2-K Clean 2567,6 W/m2-K Actual 1760,1 W/m2-K
CONSTRUCTION OF ONE SHELL
Shell Side Tube Side
Design/Test Pressure kPaG 1000; f.v. / 2500; f.v. /
Design Temperature C 110 110
No Passes per Shell 1 3
Material EN1.4306; or equiv. 254SMO
Connections In mm 1 @ DN300 1 @ DN300
Size & Out mm 1 @ DN300 1 @ DN300
Rating Intermediate @ @
Tube No. 629 OD 25 mm Thk(Avg) 1 mm Length 7,5 m Pitch 31,5 mm
Tube Type Plain Material Avesta 254SMO Tube pattern 30
Baffles-Cross Type Single-Seg. %Cut (Diam) 25,51 Spacing(c/c) 670,27 Inlet 670,27 mm
Code Requirements EN13445
Weight/Shell 7523,4 kg Filled with Water 12853 kg
Remarks:
Revised data as per data sheet revision 0E have been considered.
Presure drops for shell/tube side at maximum hydraulic flow are 65 and 40 kPa respectively.
The total height of the heat exchanger is approximately 9300 mm. Weights are approximate.
We reserve the right for minor adjustments on heat exchanger internal details, in case of order.
From the basic design drawing in the inquiry data sheet, we conclude that TEMA type N end channels are accepted.
Reprinted with Permission (v7,3.1)