Temp Compensation Coefficient -3 Rated Voltage L 12 Volt (4s)
Boost Duration 120
Equalisation Duration 120
Voltage Cell Voltage Cell
Over Volt. Disconnect Volt (V) 14.44 3.61 Charging Limit Voltage (V) 14.10 3.53
Over Volt. Reconnect Volt. (V) 14.21 3.55 Dischargin Limit Volt.(V) 11.00 2.75
Equalisation Chargin Volt. (V) 13.99 3.50 Low Volt.Disconnect Volt(V) 11.00 2.75
Boost Chargin Volt. (V) 13.99 3.50 Low Volt. Reconnect Volt.(V) 12.42 3.10
Float Chargin Volt (V) 13.65 3.41 Under Vol.Warning Volt.(V) 12.42 3.10
Boost Recon.Charg.Volt. (V) 13.54 3.38 Under Volt.WarnReco.Volt(V) 13.01 3.25