Switch (Normally Open): A switch that will close at a specified point (temp, press, etc.). The
circle indicates that the component has screw terminals and a wire can be disconnected from it.
Switch (Normally Closed): A switch that will open at a specified point (temp, press, etc.).
No circle indicates that the wire cannot be disconnected from the component.
Ground (Wired): This indicates that the component is connected to a grounded wire. The
grounded wire is fastened to the machine.
Ground (Case): This indicates that the component does not have a wire connected to ground.
It is grounded by being fastened to the machine.
Electrical System Relay (Magnetic Switch): A relay is an electrical component that is activated by electricity.
It has a coil that makes an electromagnet when current flows through it. The
electromagnet can open or close the switch part of the relay.
C551-UP M5K1-UP N1A1-UP N4A1-UP
A6D1-UP M5T1-UP JAD1-UP SSA1-UP Solenoid: A solenoid is an electrical component that is activated by electricity. It has a
RYF1-UP GTA1-UP M1G1-UP M3G1-UP coil that makes an electromagnet when current flows through it. The electromagnet
A6J1-UP WLA1-UP J5J1-UP J6J1-UP can open or close a valve or move a piece of metal that can do work.
TAL1-UP LCC1-UP K5K1-UP K6K1-UP
CYR1-UP A7D1-UP MXL1-UP MAL1-UP Magnetic Latch Solenoid: A magnetic latch solenoid is an electrical component that is
activated by electricity and held latched by a permanent magnet. It has two coils (latch and unlatch)
FMW1-UP NPE1-UP JLX1-UP L5S1-UP that make electromagnet when current flows through them. It also has an internal switch that places
BJ61-UP A7G1-UP MHG1-UP PCW1-UP the latch coil circuit open at the time the coil latches.
BS61-UP A7J1-UP A8J1-UP R4A1-UP
T6A1-UP WXZ1-UP JMS1-UP FER1-UP Harness and Wire Symbols
FLL1-UP PBG1-UP PF81-UP J5M1-UP Wire, Cable, or Harness Harness Identification Letter(s):
TFS1-UP PEM1-UP W7K1-UP Assembly Identification: Includes (A, B, C, ..., AA, AB, AC, ...)
NGX1-UP Z4W1-UP NEP1-UP Harness Identification Letters and
Harness Connector Serialization Code:
Harness Connector Serialization
GTZ1-UP Codes (see sample).
The "C" stands for "Connector" and the
number indicates which connector in the
AG-C4 L-C12 harness (C1, C2, C3, ...).
L-C12
111-7898 3E-5179 3E-5179
Part Number: for Connector Plug 1
Part Number: for Connector Receptacle
2
5A
Plug Receptacle Component
Pin or Socket Number Fuse (5 Amps) 9X-1123 Part Number
© 2020 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, LET’S DO THE WORK, their respective logos, “Caterpillar Yellow,” the “Power Edge”
and Cat “Modern Hex” trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without
permission.
1552264 1552264
USB D- 31 F529-A162 3447617 4
USB D+ 32 F528-A163 3447617 A105-A125 OR-18-GXL 1 1 A105-K1 OR-18-GXL 1 M906-X132 BU-18-GXL ROD END PRESS (PWM 1)
33 F712-A45 GN-18-GXL A105-A126 OR-18-GXL 2 2 A105-K2 OR-18-GXL 2 SNSR IN
BROADR-REACH 1+ 34 F712-A258 GN-18-GXL A105-A127 OR-18-GXL 3 3 A105-K3 OR-18-GXL 3 M906-X310 BU-18-GXL
BROADR-REACH 1- 35 F712-A252 GN-18-GXL A105-A128 OR-18-GXL 4 SNSR 8V +/- 4 A105-K4 OR-18-GXL 4 J-C1 J-C2 ROD END PRESS
10/100 BASE-T(TXD) +5 36 X998-A117 BR-18-GXL 5 CONNECT TO COMPLETER HARNESS (K) 5 X998-K5 BR-18-GXL 5 3E3376 2304013 PWM 4
10/100 BASE-T(TXD) -5 37 F712-A253 GN-18-GXL X998-A118 BR-18-GXL 6 6 X998-K6 BR-18-GXL 6 1 A105-J192 OR-18-GXL 1 +8V
10/100 BASE-T(RXD) +5 38 F712-A35 GN-18-TXL X998-A119 BR-18-GXL 7 7 X998-K7 BR-18-GXL 7 390-X214 YL-18-GXL
2 200-J184 BK-18-GXL 2 GND
10/100 BASE-T(RXD) -5 39 F712-A260 GN-18-GXL X998-A120 BR-18-GXL 8 8 X998-K8 BR-18-GXL 8 3 M909-J188 BU-18-GXL 3 SIG
40 390-X72 YL-18-GXL KEY SWITCH IN
4
USB SHLD 41 C260-A164 SH 3447617 F712-A260 GN-18-GXL
USB VBUS 42 F527-A166 RD 3447617 F712-A172 GN-18-GXL 390-X215 YL-18-GXL
USB GND 43 C255-A165 BK 3447617 F712-A308 GN-18-GXL
USB GND 44
SW TO GND 3
22
23
HARNESS ASSEMBLIES SPLICE
BR BROWN
GN GREEN
U922-A207 BK-20-TXL
SW TO GND 2
SW TO GND 1
24
25
26
U921-A206 BK-20-TXL IDENT PART NO CHG DESCRIPTION 200-X212 BK-18-GXL
BLADE, SPADE, RING OR SCREW
TERMINAL BU BLUE
27
28 A 540-3761 03 CORE CPM 200-X145 BK-18-GXL GROUND IN
300 mA SINK 3 29 E271-A202 BU-18-TXL
200-X213 BK-18-GXL
300 mA SINK 2
300 mA SINK 1
30
31
E272-A216 RD-18-TXL
E273-A217 RD-18-TXL X 572-0935 00 CORE COMPLETER
32
STORE SWITCH
SW TO GND 4
33
34 U924-A144 BK-20-TXL R 572-0936 00 14-9 SERVICE ADAPTER X-C11
3E3370
263-1493
SW TO GND WAKE-UP 35
WH
+ BTRY
- BTRY
36
37
101-A73 RD-18-TXL
200-A105 BK-18-TXL K 572-0937 00 POWER COMPLETER U924-X144 BK-18-GXL
200-X75 BK-18-GXL
A
B
C
BR
BK
38
10/100 BASE-T(TXD) +4 39 1654-A190 WH/OR 4672859
C 549-7831 02 DISPLAY THIS SCHEMATIC IS FOR THE MWL CPM KIT ELECTRICAL SYSTEM
10/100 BASE-T(TXD) -4 40 1655-A189 OR 4672859
10/100 BASE-T(RXD) +4 41 1656-A188 WH/GN 4672859 MEDIA NUMBER: M0091383-01
10/100 BASE-T(RXD) -4 42 1657-A187 GN 4672859
R-TERM/STB
43
44
SCHEMATIC PART NUMBER: 573-1863, CHANGE: 00, VERSION: -
Components are shown installed on a fully operable machine with the key and engine off, transmission shifter
in neutral and with parking brake set.
Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.
Refer to the Parts Manual using a specific serial number prefix in SIS before ordering parts from this schematic.