Professional Documents
Culture Documents
up to 4 Storeys:
Lightweight Cladding.
Intended Use
of this Document
This document provides example key
assembly interface details showing the These example details are intended to provide architects,
use of ROCKWOOLTM products within builders, and contractors with general guidance on the
best practice approach to maintain:
a split-insulated wall assembly for
commercial buildings up to 4 stories. • Air barrier continuity,
The example details could be modified for other building • Water resistant barrier (moisture barrier) continuity,
types or applications. The intended use has been limited
• Thermal continuity and minimizing thermal bridges,
to 4 stories for the sole purpose of creating boundaries
around the detail development. The example details • Cladding attachment and detailing, and
are designed to be generally applicable across North
America; however, specific end use applications vary • Adequate drainage and ventilation of the wall cavity.
widely as to design, materials, and environments.
Therefore, what is appropriate in any specific end It is important to note these details show one method
use application is a determination that must be made of constructing a split-insulated, exterior air barrier wall
independently by the experienced Project Architect assembly; however, subtle changes at interface locations
and/or Engineer in their own professional judgment. could be made to achieve the same intent. Review the
ROCKWOOLTM fully disclaims any liability for any of building code requirements for your jurisdiction to ensure
the content contained herein whether such liability be that all wall assembly detailing is in general conformance,
premised on a theory of contract, tort, or otherwise. or contact ROCKWOOLTM Building Science Support for
support on your project.
ROCKWOOL
1
Fill cavity with 512" (140mm)
ROCKWOOL COMFORTBATT® ,
[312" (89mm) ROCKWOOL Plywood/OSB sheathing
COMFORTBATT® also available]
Polyethylene sheet**
2x6 framed wall
Lightweight horizontal
Acoustic caulking cladding (fiber-cement,
wood, vinyl siding)
Plywood/OSB subfloor installed over 3/4"
vertical strapping.
Strapping fastened
through insulation to
framing.
Polyethylene sealed
to wall (AB) Drainage mat c/w
Concrete slab integral geotextile
on grade
8"
fabric (optional)
Foundation
dampproofing/
waterproofing
slope
AB = Air Barrier
WRB = Water Resistive Barrier
* For thermal performance of ROCKWOOLTM products, please refer to ROCKWOOLTM technical data sheets
** Interior vapor control for cold climates shown. For further climate zone specific considerations for thermal, air and vapor control methodologies and requirements, please contact
ROCKWOOLTM Building Science.
Alternate insulation
location, Free-draining
ROCKWOOL backfill
COMFORTBATT®
to fill stud cavity**
Polyethylene sealed
to wall (AB) 212" (64mm) ROCKWOOL
COMFORTBOARDTM
80/110 insulation
Polyethylene sheet
below slab, all laps
and edges sealed
Foundation
(AB,WRB)**
dampproofing/
waterproofing (WRB)
Concrete slab
on grade
Capillary break
AB = Air Barrier
WRB = Water Resistive Barrier
* For thermal performance of ROCKWOOLTM products, please refer to ROCKWOOLTM technical data sheets
** Interior vapor control for cold climates shown. For further climate zone specific considerations for thermal, air and vapor control methodologies and requirements, please contact
ROCKWOOLTM Building Science.
Fill cavity with 512"
(140mm) ROCKWOOL
COMFORTBATT® ,
1 Plywood/OSB sheathing
[3 2" (89mm) ROCKWOOL
COMFORTBATT® also
available]
Lightweight horizontal
cladding (fiber-cement,
2x6 framed wall wood, vinyl siding) installed
over 3/4" vertical strapping.
Strapping fastened
Acoustic caulking through insulation to
framing.
Plywood/OSB subfloor
Insect screen
4" min.
* For thermal performance of ROCKWOOLTM products, please refer to ROCKWOOLTM technical data sheets
** Interior vapor control for cold climates shown. For further climate zone specific considerations for thermal, air and vapor control methodologies and requirements, please contact
ROCKWOOLTM Building Science.
Vapor control layer **
Vapor permeable
1 membrane (AB/WRB)**
Fill cavity with 5 2"
(140mm) ROCKWOOL
Self adhesive through-wall
COMFORTBATT® ,
1
flashing membrane w/
[3 2" (89mm) ROCKWOOL sealant at top edge (WRB)
COMFORTBATT® also
available]
Insect screen
2x6 framed wall
Acoustic caulking
Metal cross-cavity flashing
Plywood/OSB subfloor c/w end dams (optional)
312" ROCKWOOL
thermal barrier(as
drawn) or approved
barrier by local
building code
Acoustic caulking
Lightweight horizontal
Vapor control layer ** cladding (fiber-cement,
wood, vinyl siding) installed
over 3/4" vertical strapping.
Strapping fastened
through insulation to
Fill cavity with 512" framing.
(140mm) ROCKWOOL
COMFORTBATT® ,
1
[3 2" (89mm) ROCKWOOL 212" (64mm) ROCKWOOL
COMFORTBATT® also COMFORTBOARDTM
available] 80/110 insulation
Plywood/OSB sheathing
* For thermal performance of ROCKWOOLTM products, please refer to ROCKWOOLTM technical data sheets
** Interior vapor control for cold climates shown. For further climate zone specific considerations for thermal, air and vapor control methodologies and requirements, please contact
ROCKWOOLTM Building Science.
Vapor control layer **
Plywood/OSB
Fill cavity with 512" (140mm) sheathing
ROCKWOOL
COMFORTBATT® ,
[312" (89mm) ROCKWOOL
COMFORTBATT® also Lightweight horizontal
available] cladding (fiber-cement,
wood, vinyl siding)
2x6 framed wall installed over 3/4" vertical
strapping. Strapping
fastened through
Acoustic caulking insulation to framing.
Plywood/OSB subfloor
212" (64mm) ROCKWOOL
COMFORTBOARDTM
80/110 insulation
membrane (AB/WRB)**
COMFORTBATT®
Self adhesive through-wall
flashing membrane w/
sealant at top edge (WRB)
Intermittent blocking
attached to soffit
strapping
Preformed metal
flashing c/w drip
edge over
sheathing lip and
212" (64mm) ROCKWOOL extend to edge of
COMFORTBOARDTM soffit cladding
80/110 insulation
Lightweight soffit cladding Insect screen
installed over 3/4" strapping.
* For thermal performance of ROCKWOOLTM products, please refer to ROCKWOOLTM technical data sheets
** Interior vapor control for cold climates shown. For further climate zone specific considerations for thermal, air and vapor control methodologies and requirements, please contact
ROCKWOOLTM Building Science.
212" (64mm) ROCKWOOL
COMFORTBOARDTM 80/110
insulation
Vapor control layer **
Self adhesive through-wall
flashing membrane w/ sealant
at top edge (WRB)
Gypsum board Vapor permeable membrane
(AB/WRB)**
Tape (AB)
Fill cavity with 512"
8" min.
(140mm) ROCKWOOL
COMFORTBATT® , Trim board
[312" (89mm) Balcony membrane
ROCKWOOL
COMFORTBATT® also Sealant at perimeter edges of
available] membrane between
2" min.
cantilevered joists (AB)
2x6 framed wall
2% min. SLOPE
Acoustic caulking
Plywood/OSB subfloor
Tapered sleepers
* For thermal performance of ROCKWOOLTM products, please refer to ROCKWOOLTM technical data sheets
** Interior vapor control for cold climates shown. For further climate zone specific considerations for thermal, air and vapor control methodologies and requirements, please contact
ROCKWOOLTM Building Science.
slope
Self-adhered membrane to Pre-finished parapet
lap from roof membrane, up cap flashing c/w hook
over parapet (WRB) clips, both sides, for
attachment
min. 2"
COMFORTBATT®
2 1/2"
Roofing membrane
installed as per
manufacturers instructions
1/2"
(2-ply SBS illustrated slope
approach not shown) Insect screen
* For thermal performance of ROCKWOOLTM products, please refer to ROCKWOOLTM technical data sheets
** Interior vapor control for cold climates shown. For further climate zone specific considerations for thermal, air and vapor control methodologies and requirements, please contact
ROCKWOOLTM Building Science.
Insulation baffle
(site-built or
pre-formed)
Shingles
212" (64mm) ROCKWOOL
COMFORTBOARDTM
ve 1/2 .
ion
2 in
lat "
m
80/110 insulation
nti
Self-adhered eave protection
membrane (WRB)
5"
Metal eave
flashing and gutter
2"±
Vented lightweight
soffit
Plywood/OSB sheathing
* For thermal performance of ROCKWOOLTM products, please refer to ROCKWOOLTM technical data sheets
** Interior vapor control for cold climates shown. For further climate zone specific considerations for thermal, air and vapor control methodologies and requirements, please contact
ROCKWOOLTM Building Science.
2x3 on end
Self-adhesive vapor
permeable membrane
2 layers 212" (64mm) ROCKWOOL
(AB)** COMFORTBOARDTM 80/110
insulation, joints offset and staggered
Shingles
Self-adhered eave
protection membrane (WRB)
2 1 in.
ion
nti /2"
m
lat
ve
5"
2"±
Metal eave
flashing and gutter
Plywood/OSB sheathing
* For thermal performance of ROCKWOOLTM products, please refer to ROCKWOOLTM technical data sheets
** Interior vapor control for cold climates shown. For further climate zone specific considerations for thermal, air and vapor control methodologies and requirements, please contact
ROCKWOOLTM Building Science.
2" Closed cell spray
foam insulation** Vapor permeable
membrane (AB/WRB)
312" ROCKWOOL
thermal barrier(as Plywood/OSB sheathing
drawn) or approved
barrier by local
building code Lightweight horizontal
cladding (fiber-cement,
wood, vinyl siding) installed
Acoustic caulking over 3/4" vertical strapping.
Strapping fastened
through insulation to
framing.
Tape (AB)
Insect screen
Backer rod and sealant joint
from window frame to
membrane (compatible
with/adhering to prestrip
membrane) (AB)
Double glazed,
flange-mounted window
* For thermal performance of ROCKWOOLTM products, please refer to ROCKWOOLTM technical data sheets
** Interior vapor control for cold climates shown. For further climate zone specific considerations for thermal, air and vapor control methodologies and requirements, please contact
ROCKWOOLTM Building Science.
Sealant joint from window
Double glazed,
frame to membrane/angle
flange-mounted window
for air continuity
Sealant
Continuous metal
back dam angle
Metal cross-cavity
Blocking to suit flashing c/w end dams
gypsum board return
Insect screen
or interior trim
3"
Acoustic caulking
1
8" intermittent shims
Plywood/OSB sheathing
* For thermal performance of ROCKWOOLTM products, please refer to ROCKWOOLTM technical data sheets
** Interior vapor control for cold climates shown. For further climate zone specific considerations for thermal, air and vapor control methodologies and requirements, please contact
ROCKWOOLTM Building Science.
Vapor control layer ** Acoustic caulking
Blocking to suit gypsum
Fill cavity with 512" (140mm)
board return or interior trim
ROCKWOOL COMFORTBATT®
[312" (89mm) ROCKWOOL
COMFORTBATT® also available] Backer rod and sealant
joint from window frame
to membrane for air
Vapor permeable start strip to continuity
extend into rough opening
Foil-faced self-adhered
membrane
Double glazed,
flange-mounted window
Pre-finished sill
Plywood/OSB sheathing
flashing below
Vapor permeable membrane
jamb prestrip (AB/WRB)** Window trim surround
* For thermal performance of ROCKWOOLTM products, please refer to ROCKWOOLTM technical data sheets
** Interior vapor control for cold climates shown. For further climate zone specific considerations for thermal, air and vapor control methodologies and requirements, please contact
ROCKWOOLTM Building Science.
Vapor permeable
membrane (AB/WRB)
Vapor permeable
Vapor control layer ** membrane (AB/WRB)
Tape (AB)
Insect screen
* For thermal performance of ROCKWOOLTM products, please refer to ROCKWOOLTM technical data sheets
** Interior vapor control for cold climates shown. For further climate zone specific considerations for thermal, air and vapor control methodologies and requirements, please contact
ROCKWOOLTM Building Science.
Sealant joint from window Double glazed
frame to membrane/angle window c/w subclip
for air continuity
Sealant
Continuous metal
back dam angle
Metal cross-cavity
Blocking to suit flashing c/w end dams
gypsum board return
Insect screen
or interior trim
3"
Acoustic caulking
Vapor permeable
membrane (AB/WRB)**
Plywood/OSB sheathing
* For thermal performance of ROCKWOOLTM products, please refer to ROCKWOOLTM technical data sheets
** Interior vapor control for cold climates shown. For further climate zone specific considerations for thermal, air and vapor control methodologies and requirements, please contact
ROCKWOOLTM Building Science.
Vapor control layer ** Acoustic caulking
Foil-faced self-adhered
membrane
Double glazed
window c/w subclip
Pre-finished sill
Plywood/OSB sheathing
flashing below
Vapor permeable membrane
jamb prestrip (AB/WRB)** Window trim surround
212" (64mm) ROCKWOOL
COMFORTBOARDTM 80/110
insulation
Lightweight horizontal cladding
(fiber-cement, wood, vinyl siding)
installed over 3/4" vertical
strapping. Strapping fastened
through insulation to framing.
Vapor permeable membrane
taped to prestrip (AB/WRB)**
* For thermal performance of ROCKWOOLTM products, please refer to ROCKWOOLTM technical data sheets
** Interior vapor control for cold climates shown. For further climate zone specific considerations for thermal, air and vapor control methodologies and requirements, please contact
ROCKWOOLTM Building Science.